Nidek CEM-530 Specular Microscope For Sale

$3,250.00

Combination of auto and manual analyses

All three manual analysis methods can be performed on the same image and also on auto-analyzed images. The versatility of combining automated and manual analyses allows analysis of the range of pathology in a comprehensive practice.

The CEM-530 with new advanced software and enhanced image capture system allows rapid image acquisition.

 

Other people want this. 15 people have this in their carts right now.

Description

Nidek CEM-530 Specular Microscope

The analysis results with graphic and color-coded cell images helps the clinician to rapidly and effectively evaluate the endothelial cell layer.

In addition to conventional central and peripheral specular microscopy, the CEM-530 includes a unique function to capture paracentral images.

  • Paracentral specular microscopy
  • Faster measurements and two-second auto analysis
  • Comprehensive analysis
  • Advanced manual analysis functions
  • Easy operation
  • Additional features with CEM Viewer for NAVIS-EX

Combination of auto and manual analyses

All three manual analysis methods can be performed on the same image and also on auto-analyzed images. The versatility of combining automated and manual analyses allows analysis of the range of pathology in a comprehensive practice.

Features

  • Multi area specular microscopy
  • Enhanced usability and quick analysis
  • Advanced manual analysis functions
  • Combination of auto and manual analyses
  • Additional features with CEM Viewer for NAVIS-EX

Multi area specular microscopy

In addition to conventional central and peripheral specular microscopy, the CEM-530 includes a NIDEK original function that captures paracentral images. The combination of central, paracentral, and peripheral imaging provides a broader, overall view that can be used for detailed morphological and quantitative evaluation of the endothelial layer and individual cells.



Enhanced usability and quick analysis


The 3D auto tracking and auto shot functions result in a user friendly and patient friendly experience.
Data analysis within 2 seconds allows efficient patient flow.


Detail analysis


Advanced manual analysis functions


Center point


Select the approximate center of a cell. The cells are detected based on the surrounding points. This method is effective for areas where groups of cells are clumped together.





Corner point


Trace the outlines of the cells to be analyzed by selecting the corners of each cell. This method is suitable for detailed identification of the size and dimension of isolated cells.





Pattern select


Select a hexagonal reference pattern that is similar to the cell size and drag it onto the cell to be analyzed. This method is effective for rough identification of the size and dimension of the cells.



 

Combination of auto and manual analyses

 

All three manual analysis methods can be performed on the same image and on auto-analyzed images. The versatility of combining automated and manual analysis on the same image allows for better clinical interpretation of the diverse range of pathology in a comprehensive practice.



Additional features with CEM Viewer for NAVIS-EX* (optional)


CEM Viewer is software used for viewing and working with CEM-530 data via NAVIS-EX. This function enhances the capability of the CEM-530 with additional features and increases the efficiency of any clinic.
*NAVIS-EX is optional software and is required for use of the CEM Viewer.


Data management and endothelial cell count


Unlimited NAVIS-EX database is available for review on the CEM Viewer. The basic functions of the CEM-530 such as endothelial cell count are available on the CEM Viewer.





Progression follow-up and comparison


Multiple examination data sets are displayed in chronological order for follow-up. Additionally, two data sets are displayed for comparison. Endothelial changes can be monitored over time with this function.






Paracentral display with peripheral

The images and analyses of the paracentral and peripheral areas are displayed providing a comprehensive image of endothelial cells.


Reviews

There are no reviews yet.

Be the first to review “Nidek CEM-530 Specular Microscope For Sale”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsNidek CEM-530 Specular Microscope For Sale removeRighton Retinomax 5 Auto Refractor For Sale removeTomey RC-5000 Auto Refractor Keratometer For Sale removeZeiss Cirrus HD-OCT 4000 OCT Spectral Domain OCT HD removeNew ZEISS CIRRUS 6000 – 100 kHz OCT Imaging System removeCarl Zeiss Cirrus HD-OCT 4000 remove
NameNidek CEM-530 Specular Microscope For Sale removeRighton Retinomax 5 Auto Refractor For Sale removeTomey RC-5000 Auto Refractor Keratometer For Sale removeZeiss Cirrus HD-OCT 4000 OCT Spectral Domain OCT HD removeNew ZEISS CIRRUS 6000 – 100 kHz OCT Imaging System removeCarl Zeiss Cirrus HD-OCT 4000 remove
Image
SKU
Rating
Price $3,250.00 $4,850.00 $4,800.00 $4,500.00 $7,200.00 $3,980.00
Stock
Availability
Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Description

Combination of auto and manual analyses

All three manual analysis methods can be performed on the same image and also on auto-analyzed images. The versatility of combining automated and manual analyses allows analysis of the range of pathology in a comprehensive practice.
The CEM-530 with new advanced software and enhanced image capture system allows rapid image acquisition. 

RIGHTON RETINOMAX-5 AUTO REFRACTOMETER / KERATOMETER

  Automatic AxisCompensation and extended measurement range Not only does the device let examiner know the cylinder axis angle, but it can also be automatically adjusted if it is not level.
The Tomey RC-5000 has highly accurate measurement combined with short examination time and ease of use, makes working with the Tomey RC-5000 Autorefractor Keratometer both professional and quick. The advanced touch-screen display allows you to perform both refraction and keratometry automatically with one simple movement, capture one eye on the display and the Tomey RC-5000 will do both eyes automatically. With the new features, the Tomey RC-5000 Autorefractor Keratometer will surely make your office more efficient.The Cirrus HD-OCT is a non-contact, high resolution tomographic and biomicroscopic imaging device. It is indicated for in-vivo viewing, axial cross-sectional, and three-dimensional imaging and measurement of anterior and posterior ocular structures, including cornea, retina, retinal nerve fiber layer, ganglion cell plus inner plexiform layer, macula, and optic nerve head. The Cirrus normative databases are quantitative tools for the comparison of retinal nerve fiber layer thickness, macular thickness, ganglion cell plus inner plexiform layer thickness, and optic nerve head measurements to a database of normal subjects. The Cirrus HD-OCT is intended for use as a diagnostic device to aid in the detection and management of ocular diseases including, but not limited to, macular holes, cystoid macular edema, diabetic retinopathy, age-related macular degeneration, and glaucoma.
Performance OCT. 100,000 scans per second to power your practice.
CIRRUS  6000 is the next-generation OCT from ZEISS, delivering high-speed image capture with HD imaging detail and a wider field of view so you can make more informed decisions and spend more time with the patients who need it.Learn how you can maximize patient throughput and practice efficiency with ZEISS CIRRUS 6000.
CIRRUS 4000 delivers high-speed image capture with HD imaging detail and a wider field of view so you can make more informed decisions and spend more time with the patients who need it.
Content

Nidek CEM-530 Specular Microscope

The analysis results with graphic and color-coded cell images helps the clinician to rapidly and effectively evaluate the endothelial cell layer.In addition to conventional central and peripheral specular microscopy, the CEM-530 includes a unique function to capture paracentral images.
  • Paracentral specular microscopy
  • Faster measurements and two-second auto analysis
  • Comprehensive analysis
  • Advanced manual analysis functions
  • Easy operation
  • Additional features with CEM Viewer for NAVIS-EX
Combination of auto and manual analyses
All three manual analysis methods can be performed on the same image and also on auto-analyzed images. The versatility of combining automated and manual analyses allows analysis of the range of pathology in a comprehensive practice.Features
  • Multi area specular microscopy
  • Enhanced usability and quick analysis
  • Advanced manual analysis functions
  • Combination of auto and manual analyses
  • Additional features with CEM Viewer for NAVIS-EX
Multi area specular microscopy
In addition to conventional central and peripheral specular microscopy, the CEM-530 includes a NIDEK original function that captures paracentral images. The combination of central, paracentral, and peripheral imaging provides a broader, overall view that can be used for detailed morphological and quantitative evaluation of the endothelial layer and individual cells.


Enhanced usability and quick analysis

The 3D auto tracking and auto shot functions result in a user friendly and patient friendly experience. Data analysis within 2 seconds allows efficient patient flow.

Detail analysis


Advanced manual analysis functions
Center point

Select the approximate center of a cell. The cells are detected based on the surrounding points. This method is effective for areas where groups of cells are clumped together.




Corner point

Trace the outlines of the cells to be analyzed by selecting the corners of each cell. This method is suitable for detailed identification of the size and dimension of isolated cells.




Pattern select

Select a hexagonal reference pattern that is similar to the cell size and drag it onto the cell to be analyzed. This method is effective for rough identification of the size and dimension of the cells.


 Combination of auto and manual analyses 
All three manual analysis methods can be performed on the same image and on auto-analyzed images. The versatility of combining automated and manual analysis on the same image allows for better clinical interpretation of the diverse range of pathology in a comprehensive practice.


Additional features with CEM Viewer for NAVIS-EX* (optional)
CEM Viewer is software used for viewing and working with CEM-530 data via NAVIS-EX. This function enhances the capability of the CEM-530 with additional features and increases the efficiency of any clinic. *NAVIS-EX is optional software and is required for use of the CEM Viewer.
Data management and endothelial cell count

Unlimited NAVIS-EX database is available for review on the CEM Viewer. The basic functions of the CEM-530 such as endothelial cell count are available on the CEM Viewer.




Progression follow-up and comparison

Multiple examination data sets are displayed in chronological order for follow-up. Additionally, two data sets are displayed for comparison. Endothelial changes can be monitored over time with this function.





Paracentral display with peripheral
The images and analyses of the paracentral and peripheral areas are displayed providing a comprehensive image of endothelial cells.

Righton Retinomax 5 Auto Refractor

The Retinomax Series, the world’s leading handheld autorefractor and autorefractor/keratometer, delivers wide measurement range on par with table type refr, now boasts greater mobility, stability and accuracy. The Retinomax series is widely used as a global standard device for pediatric, screening, medical care in remote areas, disaster area and wide range of ophthalmic scene.FEATURES
  • View Finder – With view finder observation, no limit of operator age. Diopter adjustable range is +/-8D the same as Retinomax3. View finder arm angle is changeable of 0-135 degrees, making measurement easy regardless of patient’s position or posture. Adjustable diopter +/- 8D.
  • Wider Eye Piece – Eye piece relief is 48mm from 32.2mm so that enable to look inside image while even looking at outside. No need to stick eye to the eyepiece all the time.
  • Improved battery life – At 180 minutes, the battery capacity is now twice that of conventional models
  • Automatic Axis Compensation and Extended Measurement Range – Not only does the device let examiner know the cylinder axis angle, but it can also be automatically adjusted if it is not level
  • New Child Mode – While the measurement is being taken, a melody plays continually to keep children’s attention. A constantly changing color display, both on the outside and inside target the device, also keeps children involved during the process.
  • Light weight and easy-to-hold grip
View Finder Righton Retinomax 5 Auto RefractorWith view finder observation, no limit of operator age. Diopter adjustable rangeis +/-8D the same as Retinomax3. View finder arm angle is changeable of 0-135degrees, making measurement easy regardless of patient’s position or posture.Adjustable diopter +/- 8D.Improved battery lifeAt 180 minutes, the battery capacity is now twice that of conventional modelsWider Eye PieceEye piece relief is 48mm from 32.2mm so that enable to look inside image while even looking at outside. No need to stick eye to the eyepiece all the time.Focus AssistLets you know the exact focusing point with the following color-coding system.New Child ModeWhile the measurement is being taken, a melody plays continually to keep children’s attention. A constantly changing color display, both on the outside and inside of the device, also keeps children involved during the process.Automatic AxisCompensation and extended measurement range Not only does the device let examiner know the cylinder axis angle, but it can also be automatically adjusted if it is not level. 

Tomey RC-5000 Auto Refractor Keratometer

Tomey RC-5000 RefractometryNormal Mode:-Fogging is applied automatically for each measurement for more Accurate ResultsQuick Mode:-Fogging is applied as needed for consecutive measurements.IOL/CAT Mode:-This mode is used to measure cataract or pseudophakic eyes.Keratometry:-Short consecutive measurements and time provide reliable data. -Measurements at 6.00mm (R=8.0mm) as well as at 3.00mm give you enough information for contact lens fitting. -base curves of contact lenses are stored, categorized and suggested manufacturers are automatically printed.Diameter Measurements of Cornea and Pupil:-Measurement can be done easily by moving the two cursors on the display to the boundary of cornea or pupil. This is useful for deciding the diameter of a contact lens and for other contact lens fitting practice.Power Joystick:-Move the joystick ring up/down and the instrument head moves up/down quickly. -Move the joystick hand rest to the right/left or backward/forward and the instrument head moves to the right/left or backward/forward quickly. -Rotate the joystick ring and the instrument head moves up/down slowly. -Tilt the joystick and the instrument head moves in each direction slowly.Power Chinrest:-The chin rest can be moved by pushing the buttons on the front panel. No need to reach out to the chin rest for manual adjustments.Autorefractor Keratometer Features:Refractometory : Tomey RC-5000 Auto Refractor Keratometer-Sphere 25.00 to +22.00D (VD =12.00mm) Cylinder -10.00 to +10.00D (VD = 12.00mm) -Axis 0 to 180 Degree -Minimum Pupil Dia. 2.2mm -Measurements Time 0.2 Sec.Keratometry :-Range 5.00mm to 11.00mm -Corneal Refraction 30.68D to 67.50D (n = 1.3375) -Corneal Astigmatism 0D to 10D (n = 1.3375) -Axis 0 to 180 Degree -Measured Area 3.0mm / 6.0 mm -Measured Time 0.1 Sec PD -Measurement Yes (50 to 86mm) -Diameter Measuremnt of Cornea & Pupil 1.0 to 14.0mm -Chinrest : Power Chin Rest -Printer : High Speed Thermal Line Printer -OutputPort RS-232C -Power Requirements: AC 100V to 240V -50/60Hz 130VA

Zeiss Cirrus HD-OCT 4000 OCT Spectral Domain OCT HD

Accessories
  •     The ZEISS Certified Factory Direct Cirrus 4000 HD-OCT also includes the full Accessory Kit
  •     External Fixation Light
  •     Test Eye
  •     Mini Keyboard
  •     Optical Mouse
  •     Dust Cover
  •     Metric 5A/250v Fuse
  •     14 Ft. CAT 5e Network Cable
  •     USB Cable
  •     IEC 320 to NEMA 12 inch Power Cable
  •     IEC 320 39in. Power Cable
  •     Install Disc including Roxio Basic
  •     Symbol Sheet
  •     OCT Primer Guide
  •     Quick Start Guide
HD-OCT Imaging
  • Methodology: Spectral Domain OCT
  • Optical Source: superluminescent diode (SLD), 840 nm
  • Optical Power: < 725 μW at the cornea
  • Scan Speed: 27,000 A-scans per second
  • A-Scan depth: 2.0 mm (in tissue), 1024 points
  • Axial resolution: 5 μm (in tissue)
  • Transverse resolution: 15 μm (in tissue)
Fundus Imaging
  • Methodology: Line scanning ophthalmoscope
  • Live Fundus Image: During alignment and during OCT scan
  • Optical Source: Superluminescent diode (SLD), 750 nm
  • Optical Power: < 1.5 mW at the cornea
  • Field of View: 36 degrees W x 30 degrees H
  • Frame rate: >20 Hz
  • Transverse resolution: 25 μm (in tissue)
Iris Imaging
  • Methodology: CCD Camera
  • Resolution: 1280 x 1024
  • Live iris image: During alignment
Electrical, Physical and Environmental
  • Weight: 38kg (83 lbs)
  • Dimensions: 65L x 44W x 53H (cm)
  • Fixation: Internal, external
  • Internal fixation focus adjustment: -20D to +20D (diopters)
  • Input devices: Keyboard, mouse
  • Electrical rating (115V) Single Phase, 100/120V~ systems:50-60Hz, 5A
  • Fuse rating (115V) T 5A 250V
  • Electrical rating (230V) Single Phase, 220/240V~ systems:50-60 Hz, 2.5A
  • Fuse rating (230V) Fuse rating: T 5A 250V
  • Convenience Receptacle output ratings 115V~, 0.5 A Max, 50-60 Hz
  • Temperature (transport and storage) -40º to +70º C
  • Relative humidity (transport and storage) 10% to 100%, including condensation
  • Atmospheric pressure (transport and storage): 500 hPa to 1060 hPa
  • Temperature (operation) +10º to +35º C
  • Relative humidity (operation) 30% to 75%, excluding condensation
  • Atmospheric Pressure (operation) 700 hPa to 1060 hPa
Computer Zeiss Cirrus HD-OCT 4000 OCT Spectral Domain OCT HD
  • • High performance multi-core processor
  • • Internal storage: > 80,000 scans
  • • CD-RW, DVD-ROM drive
  • • Integrated 15″ color flat panel display.
The Cirrus HD-OCT is a non-contact, high resolution tomographic and biomicroscopic imaging device. It is indicated for in-vivo viewing, axial cross-sectional, and three-dimensional imaging and measurement of anterior and posterior ocular structures, including cornea, retina, retinal nerve fiber layer, ganglion cell plus inner plexiform layer, macula, and optic nerve head. The Cirrus normative databases are quantitative tools for the comparison of retinal nerve fiber layer thickness, macular thickness, ganglion cell plus inner plexiform layer thickness, and optic nerve head measurements to a database of normal subjects. The Cirrus HD-OCT is intended for use as a diagnostic device to aid in the detection and management of ocular diseases including, but not limited to, macular holes, cystoid macular edema, diabetic retinopathy, age-related macular degeneration, and glaucoma.
New ZEISS CIRRUS 6000 – 100 kHz OCT Imaging System
Faster, wider with a new level of detail
At 100,000 scans per second, ZEISS CIRRUS 6000 enables clinicians to image a larger field of view up to 12mm in a single scan. It also captures high-defintion (HD) OCT and OCT Angiography (OCTA) scans, revealing the finer microvascular details of the retina and providing more insight into your patient’s condition.
Making the revolutionary, routine.ZEISS AngioPlex OCT Angiography New ZEISS CIRRUS 6000 – 100 kHz OCT Imaging System
AngioPlexOCT Angiography from ZEISS ushers in a new era of eye care with non-invasive imaging of retinal microvasculature—taking glaucoma and retinal disease management and treatment planning to the next level. By offering the industry’s most comprehensive tools for assessing and analyzing a range of pathologies, ZEISS provides a complete OCT Angiography (OCTA) solution.
CIRRUS 6000 is the latest addition to an already robust portfolio of OCT devices that are designed to meet the needs of all types and levels of practices and/or clinicians. It offers customers high-speed and high-throughput to help manage their large patient volume faster, all while improving imaging and image quality.
“This system was designed with the patient in mind, enabling doctors to continue accessing their patient data from CIRRUS devices that are crucial to effective long-term patient care,” said Jim Mazzo, Global President of Ophthalmic Devices at Carl Zeiss Meditec. “We are committed to our customers and believe this will become an essential asset to their practice.”The 100kHz speed of the CIRRUS 6000 allows clinicians to scan patients faster, with increased efficiency and improved imaging detail. Additional features include:
  • Wider and deeper OCT/OCTA scans with 12x12mm OCTA and B-scan depth up to 2.9mm
  • HD AngioPlex scan is a new scan type that provides more detail
  • New workflow protocols to aid in increasing efficiency
  • Patient-friendly “Wellness report” to help educate the patient
According to retina and vitreoretinal physician and surgeon Gregg T. Kokame, MD, of Retina Consultants of Hawaii, the new ZEISS CIRRUS 6000 is extremely fast and impressive. “With the new scan acquisition time of 100,000 per second I can scan and assess my patients much quicker, giving me the details I need with every image,” says Kokame.“ZEISS is dedicated to advancing eye care through development of new and innovative solutions, like the CIRRUS 6000,” said Dr. Ludwin Monz, President and CEO of Carl Zeiss Meditec AG. “With our comprehensive diagnostics portfolio, we will continue to create better vision standards to benefit patients today and in the future.”

Carl Zeiss Cirrus HD-OCT 4000

The Cirrus HD-OCT is a non-contact, high resolution tomographic and biomicroscopic imaging device. It is indicated for in-vivo viewing, axial cross-sectional, and three-dimensional imaging and measurement of anterior and posterior ocular structures, including cornea, retina, retinal nerve fiber layer, ganglion cell plus inner plexiform layer, macula, and optic nerve head. The Cirrus normative databases are quantitative tools for the comparison of retinal nerve fiber layer thickness, macular thickness, ganglion cell plus inner plexiform layer thickness, and optic nerve head measurements to a database of normal subjects. The Cirrus HD-OCT is intended for use as a diagnostic device to aid in the detection and management of ocular diseases including, but not limited to, macular holes, cystoid macular edema, diabetic retinopathy, age-related macular degeneration, and glaucoma.The ZEISS Certified Factory Direct Cirrus 4000 HD-OCT also includes the full Accessory Kit External Fixation Light Test Eye Mini Keyboard Optical Mouse Dust Cover Metric 5A/250v Fuse 14 Ft. CAT 5e Network Cable USB Cable IEC 320 to NEMA 12 inch Power Cable IEC 320 39in. Power Cable Install Disc including Roxio Basic Symbol Sheet OCT Primer Guide Quick Start GuideHD-OCT ImagingMethodology: Spectral Domain OCT Optical Source: superluminescent diode (SLD), 840 nm Optical Power: < 725 μW at the cornea Scan Speed: 27,000 A-scans per second A-Scan depth: 2.0 mm (in tissue), 1024 points Axial resolution: 5 μm (in tissue) Transverse resolution: 15 μm (in tissue)Zeiss Cirrus HD-OCT 4000 OCT Spectral Domain OCT HD Fundus ImagingMethodology: Line scanning ophthalmoscope Live Fundus Image: During alignment and during OCT scan Optical Source: Superluminescent diode (SLD), 750 nm Optical Power: < 1.5 mW at the cornea Field of View: 36 degrees W x 30 degrees H Frame rate: >20 Hz Transverse resolution: 25 μm (in tissue)Carl Zeiss Cirrus HD-OCT 4000 Iris ImagingMethodology: CCD Camera Resolution: 1280 x 1024 Live iris image: During alignmentElectrical, Physical and EnvironmentalWeight: 38kg (83 lbs) Dimensions: 65L x 44W x 53H (cm) Fixation: Internal, external Internal fixation focus adjustment: -20D to +20D (diopters) Input devices: Keyboard, mouse Electrical rating (115V) Single Phase, 100/120V~ systems:50-60Hz, 5A Fuse rating (115V) T 5A 250V Electrical rating (230V) Single Phase, 220/240V~ systems:50-60 Hz, 2.5A Fuse rating (230V) Fuse rating: T 5A 250V Convenience Receptacle output ratings 115V~, 0.5 A Max, 50-60 Hz Temperature (transport and storage) -40º to +70º C Relative humidity (transport and storage) 10% to 100%, including condensation Atmospheric pressure (transport and storage): 500 hPa to 1060 hPa Temperature (operation) +10º to +35º C Relative humidity (operation) 30% to 75%, excluding condensation Atmospheric Pressure (operation) 700 hPa to 1060 hPa
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
You're viewing: Nidek CEM-530 Specular Microscope For Sale $3,250.00
Add to cart
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
  • Attributes
  • Custom attributes
  • Custom fields
Click outside to hide the comparison bar
Compare
Shopping cart close