| Description | The Dual Wavelength Solution that Delivers Suitable Parameters with an Incredible Fast Treatment SpeedLutronic CLARITY is a dual wavelength platform combining long pulsed 755 nm Alexandrite and 1064 nm Nd:YAG. CLARITY’s advanced features enable treatment versatility and greater speed. | Includes:
Blue LED Lamp
Revive (Red) Lamp
3 Patient Eyewear
Operators Manual
Power Cord | This technology sends a focused stream of cool air to the treatment area for added patient conformation during treatment,. Used In conjunction with Frax 1550 and Nd:YAg treatments.The Nordlys laser is equivalent to 6 stand alone devices in one. It allows you to grow with your business by adding applications as you go. With the Nordlys laser you have a great potential for return on investment with low running costs and fast treatment times. | Key Features:- Light weight, ergonomic and balanced handpiece to reduce operator fatigue
- Large spot size (14 x 10 mm) ensures fast treatment times
- Pain Free, Super Hair Removal enhances client comfort by delivering low energy at 10 Pulses per Second (10 Hertz).
- Integrated contact cooling increases patient comfort
- No consumable cost makes it an affordable treatment
| Includes:
Footswitch
Operators Manual
AntiFreeze Coolant
Patient & Operator Eyewear | SPECIFICATIONS- Wavelength: 1064nm, 810nm, 755nm
- Screen: 10.4 Inch Full Colour LCD
- Max Output: 129 J/CM2
- Pulse Width:1 – 200 ms
- Spot Size: 12 x 12 mm
- Frequency: 1 – 10 Htz
- Input Power: 3000 w
- Output Power: 1200 w treatment head
- 100 Million Shots
- USA Laser Stack Head
- Waterproof Sapphire Crystal Handpiece
- Alma Laser Connector
- Dual Internal Filter System
|
| Content | Lutronic Clarity Long Pulsed Alexandrite & Nd:YAG LaserRESULTS YOU CAN SEEThe ability to choose from 755 nm or 1064 nm wavelength provides your clinic a highly versatile system. The CLARITY uses proven technology with advanced features to provide visible results in a single treatment.ALEX Toning
InnerLift Technique
Genesis Technique
Dual Fractional Technique
COCO TechniqueSale – Lutronic Clarity Long Pulsed Alexandrite & Nd:YAG Laser MULTIPLE TREATMENT OPTIONSAPPLICATIONS Lutronic Clarity Long Pulsed Alexandrite & Nd:YAG LaserHair removal
Skin tightening & firming
Skin rejuvenation
Large pores
Blackheads
Pigmented lesions
Epidermal pigments
Vascular lesions
Facial telangiectasia
Flushing
Rosacea
Leg veins
Warts
Onychomycosis
And more…Lutronic Clarity Long Pulsed Alexandrite & Nd:YAG Laser with Dual Fractional Feature
The Dual Wavelength Solution that Delivers Suitable Parameters with an Incredible Fast Treatment SpeedLutronic CLARITY is a dual wavelength platform combining long pulsed 755 nm Alexandrite and 1064 nm Nd:YAG. CLARITY’s advanced features enable treatment versatility and greater speed.
SPEEDSale – Lutronic Clarity Long Pulsed Alexandrite & Nd:YAG LaserA high repetition rate and large treatment spot empower CLARITY users to permanently reduce unwanted hair with unprecedented speed, allowing clinics to perform more treatments and maximise their return on investment.
EFFICACYCLARITY’s highly efficacious treatment options are rooted in the delivery of high peak power laser energy, in short pulse widths. The Flat Top beam profile provides consistent treatment for more predictable outcomes.
VERSATILITYCLARITY’s dual wavelengths permits the treatment of all skin types and its advanced features provide multi-treatment opportunities enabling clinics to treat a larger range of applications; physicians may permanently reduce unwanted hair, improve the appearance of pigmented and vascular lesions, and rejuvenate the skin with multiple treatment options.“The worldwide 1st dual fractional feature by one handpiece supports a more reliable and gentle procedure.”
CONVENIENCESingle fiber delivery with 9 spot size choices ranging up to 20 mm with both wavelengths for ease of use, increased treatment speeds and reduced costs across multiple applications
Choice of epidermal protection and comfort with built-in Intelligent Cooling Device™(ICD) or air coolingHYBRID COOLINGHybrid Cooling (Optional), available on ICD model, provides optional dual cooling for added patient comfort. | OMNILUX PHOTODYNAMIC THERAPY LIGHT SOURCEOmniLux Photodynamic Therapy Light Source, which entails the use of a photosensitizing topical medication in conjunction with exposure to red or blue light as a treatment for acne, can be quite an effective treatment.
This procedure is a good alternative to many acne treatments to include isotretinoin. Accutane and oral antibiotics. Some researchers have shown it to have similar effectiveness to these more traditional treatments. This type of treatment generally requires multiple sessions to achieve such results.The advantages of Omnilux therapy- Stimulates the bodies own cellular mechanisms by photomodulation
- Not a laser or an IPL so no heat, no side effects or downtime
- Non-invasive, non-ablative safe therapy
- No damage to sub-dermal tissue
- Relaxing and calming experience
- Allows treatment of large areas such as the face and chest
- Simple to operate
- Economically viable
Includes:
Blue LED Lamp
Revive (Red) Lamp
3 Patient Eyewear
Operators Manual
Power CordThe Importance of Your Light Source for Photodynamic TherapyPhotodynamic therapy (PDT) has been used for a variety of dermatologic conditions for many years. In the United States, PDT is considered an effective first-line therapy for treatment of skin with actinic keratoses (AK). PDT is a common therapeutic option in dermatology practices. The most commonly used photosensitizer is aminolevulinic acid (ALA). Sold under several different brand names worldwide and a variety of formulations, ALA, and variations/derivatives, is considered today’s safest and most effective PDT photosensitizing drug. Mechanism of ActionConventional PDT for the treatment of AKs, and in Europe basal cell carcinoma (BCC) and nonmelanoma skin cancer, involves the photoactivation of protoporphyrin IX (PpIX). This occurs after prodrug ALA application and uptake, PpIX selectively accumulates in the atypical, dysplastic, or malignant cells. Upon illumination, photoactivation and photobleaching of PpIX occurs, generating oxidative stress and free radical reactive oxygen species (ROS). This initiates inflammation and ensuing cytotoxicity, resulting in preferential apoptosis and necrosis of abnormal cells.To generate a therapeutic effect, the spectral output of the light source should correspond to the excitation peaks of the photosensitizer. PpIX has 2 important therapeutic peaks, 404 to 420 nm in the violet-blue spectrum, and 633 nm in the red wavelength region. The depth of light penetration into the skin increases with longer wavelengths. Although blue light allows sufficient tissue penetration for the treatment of superficial AKs, red light penetrates much deeper into skin (up to 8-mm deep) and is more effective for the treatment of thicker lesions such as BCCs when combined with ALA.
BLUE LAMP SPECS
Power:40 mW/cm2
Wavelength:415 nm
Treatment Time:20 Minutes
Lamp Type:LED
Weight: 12 Kg
REVIVE (RED) LAMP SPECS
Power:40 mW/cm2
Wavelength:633 nm
Treatment Time:20 Minutes
Lamp Type:LED
Weight:12 KgOmniLux Photodynamic Therapy Light SourcePLUS (YELLOW) INFARED LAMP SPECS
Power:30 mW/cm2
Wavelength:830 nm
Treatment Time:20 Minutes
Lamp Type:LED
Weight:12 KgLED (Light Emitted Diodes) Photodynamic Therapy Light Source
Omnilux BLUE Lamp
Omnilux blue has been specifically developed to target the naturally occurring photosensitiser, Coproporphyrin III, found in P.acnes bacteria. Omnilux blue is the most potent blue light source in activating the target photosensitiser, producing singlet oxygen that leads to rapid eradication of the P.acnes bacteria. The output of Omnilux blue is also optimised to activate the photosenstiser 5-aminolaevulinic acid and is therefore ideally suited for the treatment of Actinic keratosis. Omnilux blue delivers 40mW/cm2 48J/ cm2.The clinician can control the area of illumination and can shape the light to the contour of the treatment area. Only this way can the entire treatment area receive the required dose of light for effective therapy.Omnilux REVIVE (RED) Lamp
Omnilux revive at 633nm is proven to stimulate cellular mechanisms responsible for tissue repair and regeneration. OmniluxTM systems ensure that the right light dose is always delivered to the tissue, the right wavelength is always used to successfully activate the target cells or light reactive substrates and the right intensity is always used to prevent inefficient tissue response. The adjustable LED panels mean that the whole treatment area can be bathed in pure red light to maximize treatment outcome.Omnilux PLUS (YELLOW) INFARED Lamp
Omnilux plus utilises the core technology developed by Photo Therapeutics Ltd and can be delivered from a standard medical base unit using the interchangeable treatment head.Omnilux plus is based on a matrix of Infra Red LEDs, which provide narrowband 830nm light. The individual LED cone angle and the spacing of the LEDs ensure uniformity of the beam for full coverage of the treatment area. For safety reasons, single LEDs of visible yellow light are located in the four corners of each array in order to determine if the head is lit.Omnilux plus is used for the purpose of skin rejuvenation in combination with Omnilux revive and also for wound healing. Work is also being carried out on its use for the temporary relief of minor muscle and joint pain, arthritis, muscle spasm, relieving stiffness, promoting the relaxation of muscle tissue and to temporarily increase local blood circulation where applied.The clinician can control the area of illumination and can shape the light to the contour of the treatment area. Only this way can the entire treatment area receive the required dose of light for effective therapy. | Candela Ellipse Nordlys Laser Hair Removal
Ellipse IPLA fantastic IPL technology defined by patented dual filters as well as sub-millisecond pulses. All this adds up to exceptional photorejuvenation and vascular treatments as well as great results for hair removalFrax 1550This is no ablative fractional technology for the treatment of all types of scarring including acne and surgical. It is used for skin resurfacing treatments such as stretch marksNd:YAg 1064nmThe optimal laser wavelengths for the treatment of vascular lesions and dark skin hair removal.SoftCoolThis technology sends a focused stream of cool air to the treatment area for added patient conformation during treatment,. Used In conjunction with Frax 1550 and Nd:YAg treatments. Candela Nordlys LaserLightweight, easy to manoeuvre, arm
flexible cables to aid movement and ergonomics
Tray for keeping all accessories close to hand
Quiet operation mode
Remote service assistance
In-built patient database Candela Ellipse Nordlys Laser Hair RemovalCandela Nordlys LaserThe Nordlys laser was known originally as the ellipse Nordlys but now is been sold via Candela. It utilises 3 different foundations to be able to offer a wide range of treatment applications.The technologies found in the Candela/Ellipse Nordlys areEllipse IPL
Frax 1550 find our more about Frax
Nd:YAg 1054nmThe Nordlys laser is equivalent to 6 stand alone devices in one. It allows you to grow with your business by adding applications as you go. With the Nordlys laser you have a great potential for return on investment with low running costs and fast treatment times. This technology sends a focused stream of cool air to the treatment area for added patient conformation during treatment,. Used In conjunction with Frax 1550 and Nd:YAg treatments.The Nordlys laser is equivalent to 6 stand alone devices in one. It allows you to grow with your business by adding applications as you go. With the Nordlys laser you have a great potential for return on investment with low running costs and fast treatment times. | Ellman Cheveux 810nm Diode Laser Hair RemovalLaser Type:Pulsed AlGaAs Diode
Wavelength:810 nm
Spot Size:10 x 14 mmSuper Hair Removal
Wavelength:810 nm
Fluence:Up to 12 J/cm2
Pulse Width:30 ms
Repetition Rate: 10 Pulses per SecondStandard Hair Removal
Wavelength:810 nm
Fluence:Up to 100 J/cm2
Pulse Width:Upto 400 ms
Repetition Rate:Up to 3 Pulses per SecondCooling System:Self-Contained, Closed Loop
Electrical:100-120 VAC 12 amps; 220-240 VAC 6 amps; 50/60 Hz
Dimensions:14 in x 17 in x 38 inVersatility to Expand Your PracticeEllman Cheveux 810nm Diode Laser with its smooth flow 10 Pulses per second technology makes laser hair reduction more convenient and affordable.Proven efficacy in hair reduction for all skin types(I-VI) including tanned skin has earned the wavelength the gold standard designation. The Ellman Cheveux 810nmcombines both the latest technologies used in hair removal- super hair removal and pain free hair removal (10 pulses per second) and standard hair removal (3 Pulses per Second).Because of the combination of both the technologies in one console, Ellman Cheveux 810nm makes hair removal easier than ever. The Ellman Cheveux 810nm control panel lets the practitioner choose from both modes, enabling fine tuning of fluence and repetition rate. With one of the lightest handpiece available in the market, laser hair reduction is also easy for the operator.Key Features:Ellman Cheveux 810nm Diode Laser Hair Removal- Light weight, ergonomic and balanced handpiece to reduce operator fatigue
- Large spot size (14 x 10 mm) ensures fast treatment times
- Pain Free, Super Hair Removal enhances client comfort by delivering low energy at 10 Pulses per Second (10 Hertz).
- Integrated contact cooling increases patient comfort
- No consumable cost makes it an affordable treatment
Ellman DOES NOT require a RECERTIFICATION FEE for new owners of used equipment. Consumables and service can be obtained through Ellman WITHOUT an initial fee to a new owner. Warranty services are also available to a new owner. | ACTIVE OPTICAL EXTRA 818 IPL HAIR REMOVAL MACHINEIncludes:
Footswitch
Operators Manual
AntiFreeze Coolant
Patient & Operator EyewearHandpieces:Hair Removal Handpiece and Facial Handpiece
Chilled Tip:Up to 4c
Pulse Interval:0.5~2 Seconds
Output Power:11-31 joule/cm2, upto 4,000W
Cooling System:Revolutionary dual cooling
Control:Intuitive touch screen control
Lamp’s Life Span:250,000 Flashes (Universal), 200,000 Flashes (Facial)
Treatment Area:7.5 cm2 (15*50mm) Universal, 4.5 cm2 (15*30mm) Facial
Wavelength:420-1100 nm
Weight:42Kg (including Stand, if device is not a table top)
Dimensions:44cm x 45cm x 100cm
Extra-818
Skin Rejuvenation
Pigmentation Treatment
Acne Treatment
Hair Removal
Vascular (Facial) TreatmentThe combination of tested treatment protocols with high end engineering makes the Extra – 818 the perfect device for leading clinics.Revolutionary Cooling System
The Extra – 818 has a dual cooling system, controlled and monitored in order to ensure long lifetime to the lamp and a comfortable treatment to the patient.Competitive cooling systems “freeze” the skin so that during the treatment the skin temperature will rise to a bearable level. However, this “freezing” temperature might limit the results because the follicles will not reach the coagulation temperature. To ensure optimal results Active installed a special Processor that prevents overcooling the skin and maintains a uniform low temperature of the “glass” throughout the treatment. This revolutionary system enables the Extra – 818 to provide best results with optimal patient comfort.Research Program ACTIVE OPTICAL EXTRA 818 IPL HAIR REMOVAL MACHINE
For clinical investigations, the self setting program allows researchers to set the treatment’s parameters according to their needs. Allowing advanced research with the device.
The energy levels in the self setting program can reach 31Jcm2 with high intensity of 4,000W.The Active Optical Extra 818 IPL Hair Removal and Skin Rejuvenation is the outcome of more than a decade of treatments and thousands of devices operated worldwide. It contains It contains unique features:
* Contemporary touch screen control
* Built-in Patch Test procedure for examining the optimal energy level
* A stunning number of 450,000 flashes in both lamps.The Extra – 818, based on Active’s GEM-PL technology, sets sets a specific Pulse Pattern according to the selected treatment type, skin color, skin photosensitivity and treatment depth.
The treatment protocols and different pulse patterns take into account the tissue’s TRT (Thermal Relaxation Time) and the combined knowledge accumulated from thousands of treatments done during the years and clinical investigations done to confirm the findings. | 2021 DERMAL SOLUTIONS TRIWAVE ICE LASER
TRIWAVE LASER HAIR REMOVAL MACHINETriwave is a new diode laser that delivers three wavelengths in one to treat all skin types and hair colours. The three wavelengths combine and are delivered through a 1200 watt powerful cold treatment handpiece for pain free hair removal. 1064nm, 808nm & 755nm are combined together for the best form of hair removal. Other lasers can only deliver one wavelength but Triwave Lasers have superior technology to produce the most efficient results in hair removal. Triwave is more effective as it carefully selects the correct amount of each wavelength depending on sex, hair thickness, colour and skin type. The operator moves the handpiece up and down the skin with gel with a circular motion to the target area. Hair follicles will be destroyed instantly to eradicate unwanted hair painlessly and permanently.SPECIFICATIONS 2021 DERMAL SOLUTIONS TRIWAVE ICE LASER- Wavelength: 1064nm, 810nm, 755nm
- Screen: 10.4 Inch Full Colour LCD
- Max Output: 129 J/CM2
- Pulse Width:1 – 200 ms
- Spot Size: 12 x 12 mm
- Frequency: 1 – 10 Htz
- Input Power: 3000 w
- Output Power: 1200 w treatment head
- 100 Million Shots
- USA Laser Stack Head
- Waterproof Sapphire Crystal Handpiece
- Alma Laser Connector
- Dual Internal Filter System
SHR / SSR LASER TECHNOLOGY MACHINEThe new system combines laser technology and the benefits of pulsating light to remove hair at a faster more effective rate. Difficult hairs can be treated through In Motion technology for operator speed, patient comfort and better protection of the skin.Why? It provides a gradual thermal rise to the target therapeutic temperature without risk of injury. It eliminates the common problem of missed or skipped areas with comprehensive coverage to legs, arms and backs.Normal IPL with Multipulse modes focuses energy on one pulse, so it is easy to burn the client, however, SHR emits a single pulse mode for safer treatments. The SHR filtered violet light and infrared light will absorb water targeting the skin with no side effects.SHR accelerates operation speed and shortens the time for treatments with 1 – 10 HZ.Moving the head along the skin with a faster repetition rate of shots fired per millisecond requires less time per treatment. This is a combination of laser technology mixed with IPL so no down time, no burns, better results, faster treatments and no pain for client comfort.The SHR / SSR machine comes in different combinations to suit client needs.SHR / SSR ( no filters required – rolling heads for speed )
SHR / IPL (filters need to be used on the IPL handpiece – SHR rolling head )
SHR/ SSR / RF ( skin tightening head )
SHR / IPL / RF (skin tightening head )SHR / SSR – LASER TECHNOLOGY – COLD TREATMENT HEAD TGA Listed / FDA / ISO and European Medical CE certified. Pain Free – Cold handpiece technology allows for pain free hair reduction treatments. The speed of the equipment is faster and more effective Powerful technology – Faster Shots – Less Heat More Capacitors – No waiting time during treatments American Xenon lamps offer superior treatment Continuous pulse width and length for superior performance – SHR Rolling Head Professional On Site Training – Qualified Trainers – Government Accredited Courses Free Marketing Material – Starter Pack included Finance available – Flexirent Options On-going service, support and further training
Our medically engineered equipment offers your clients the latest state of the art machines that are affordable yet capable of the most high end professional treatments. SHR rolling hair removal systems treat most skin types and hair colours including red and blond hair. They will also treat skin types 1 – 5 with great results to keep your client’s skin looking younger and more vibrant. The anti – ageing protocol will help with collagen renewal, fibroblast production, pigmentation and vascular lesions. Delivered by one of the most powerful equipment available.
|
Reviews
There are no reviews yet.