PERKASA MEDICAL

Free shipping worldwide. Orders over $200
Availability: In Stock

Huvitz HRK-8000A Auto Refractor Keratometer For Sale

$3,500.00

The image can then be displayed on a monitor, helping you to educate your patients The HRK can provide peripheral keratometry measurement data which is very useful when fitting contact lenses. The eye can be displayed in full colour mode on a tilting touch screen which enables you to see the patient’s contact lens fitting status, previously only possible using a slit lamp. As the HRK has the world’s first contact lens fitting function in an auto keratometer, you can now see the flourescein liquid with blue illumination along with automatic calculation and recommendation for contact lens fitting.

Other people want this. 15 people have this in their carts right now.

Description

Huvitz HRK-8000A Auto Refractor Keratometer

Huvitz Auto Ref – Keratometer HRK-8000A

  • Touch and tilting 7″ LCD Screen that allows for free and smooth tilting for viewing at any angle.
  • Optimized Optical System
  • Micro Lens Array
  • Aberration Measurement which also can be displayed in a graphical Zernike Refraction Map
  • PSF & Image Simulation
  • Colour View Mode
  • Peripheral Keratometry Measurement
  • Ultra High Precision KER Data
  • Contact Lens Fitting Assistance Guide
  • Contact Lens Prescription Guide
  • Auto Tracking
  • Animated Guide
  • Faster Measurement Speed
  • Quiet and speedy auto cutting printer
  • More data on aberration measurement

With its extreme precision and accuracy, the HRK8000A uses the most advanced wavefront technology to measure the light reflected from the retina and helps you to diagnose any refractive error. With a micro lens array developed by Huvitz, the HRK creates a number of focal points, the pattern of which can give a valuable insight into the patients ocular system. The HRK not only displays the conventional data such as spherical, cylinder and axis, the high order aberration data is displayed in a graphical Zernike refractive map, giving you a deeper understanding of your patient’s eyes.

Optimized Optical System Huvitz HRK-8000A Auto Refractor Keratometer
A wavefront is a physical representation of the optical quality of a light beam. Using various methods, aberrometers map how light rays travel through the eye. The HR-8000A is engineered according to the Hartmann-Shack wavefront measurement technique, which is widely preferred for its speed and repeatability.

Touch & Tilting Color Display Screen 
A bright, high contrast 7″ VGA color TFT LCD screen provides high resolution video images. A smooth, free tilting function also offers you a comfortable and clear view at any angle.

The image can then be displayed on a monitor, helping you to educate your patients The HRK can provide peripheral keratometry measurement data which is very useful when fitting contact lenses. The eye can be displayed in full colour mode on a tilting touch screen which enables you to see the patient’s contact lens fitting status, previously only possible using a slit lamp. As the HRK has the world’s first contact lens fitting function in an auto keratometer, you can now see the flourescein liquid with blue illumination along with automatic calculation and recommendation for contact lens fitting.

Reviews

There are no reviews yet.

Be the first to review “Huvitz HRK-8000A Auto Refractor Keratometer For Sale”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsHuvitz HRK-8000A Auto Refractor Keratometer For Sale removeErchonia Zerona Z6 SHR For Sale removeNidek RS-330 Retina Scan Duo 2 with FAF removeRighton Retinomax 5 Auto Refractor For Sale removeCarl Zeiss Cirrus HD-OCT 5000 Smart Advanced Topography HD removeNidek OPD-Scan II ARK 10000 Autorefractor Keratometer remove
NameHuvitz HRK-8000A Auto Refractor Keratometer For Sale removeErchonia Zerona Z6 SHR For Sale removeNidek RS-330 Retina Scan Duo 2 with FAF removeRighton Retinomax 5 Auto Refractor For Sale removeCarl Zeiss Cirrus HD-OCT 5000 Smart Advanced Topography HD removeNidek OPD-Scan II ARK 10000 Autorefractor Keratometer remove
Image
SKU
Rating
Price $3,500.00 $5,300.00 $3,150.00 $4,850.00 $6,950.00 $5,150.00
Stock
Availability
Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

DescriptionThe image can then be displayed on a monitor, helping you to educate your patients The HRK can provide peripheral keratometry measurement data which is very useful when fitting contact lenses. The eye can be displayed in full colour mode on a tilting touch screen which enables you to see the patient’s contact lens fitting status, previously only possible using a slit lamp. As the HRK has the world’s first contact lens fitting function in an auto keratometer, you can now see the flourescein liquid with blue illumination along with automatic calculation and recommendation for contact lens fitting.Erchonia Zerona Z6 SHRZerona-Z6 works by utilizing the Erchonia’s patented low level laser technology to emulsify adipose tissue which then releases into the interstitial space. Our bodies remove the fat from the area and transport the fat from through the lymphatic system creating a slimming effect. The Zerona-Z6 was proven through a double-blind, randomized, multi-site, and placebo controlled study in which clients averaged a loss of 3.52* inches compared to the placebo group that lost only a half an inch.
The Nidek RS-330 OCT is a combination of a High-Definition OCT and fundus camera. Optional delivery with FAF (Auto-fluorescence function)

RIGHTON RETINOMAX-5 AUTO REFRACTOMETER / KERATOMETER

  Automatic AxisCompensation and extended measurement range Not only does the device let examiner know the cylinder axis angle, but it can also be automatically adjusted if it is not level.
CIRRUS HD-OCT 5000 is configured with the highest resolution visualization capabilities and sophisticated clinical applications such as Advanced RPE analysis to track retinal pigment epithelial integrity and Ganglion Cell Analysis to assess glaucomatous loss in the macula that may not be evident in the peripapillary region. The new FastTrac  retinal tracking reduces eye motion artifacts without sacrificing patient throughput with a proprietary scan acquisition strategy, high speed 20 Hz LSO camera, and single-pass alignment scanning. This feature enables the highest resolution B-Scans to be captured in identical locations from visit to visit providing precise assessment of change in targeted pathologies.The NIDEK OPD-Scan II provides information on corneal topography, wavefront, autorefraction, keratometry and pupillometry in one unit, utilizing state-of-the-art imaging and analysis technology developed specifically to measure normal to highly aberrated eyes.  The system offers a variety of data maps to provide information on the total refractive error, wavefront, corneal shape, internal aberrations and visual quality of the eye, allowing highly accurate and reliable information for optic diagnostics.
ContentHuvitz HRK-8000A Auto Refractor KeratometerHuvitz Auto Ref – Keratometer HRK-8000A
  • Touch and tilting 7″ LCD Screen that allows for free and smooth tilting for viewing at any angle.
  • Optimized Optical System
  • Micro Lens Array
  • Aberration Measurement which also can be displayed in a graphical Zernike Refraction Map
  • PSF & Image Simulation
  • Colour View Mode
  • Peripheral Keratometry Measurement
  • Ultra High Precision KER Data
  • Contact Lens Fitting Assistance Guide
  • Contact Lens Prescription Guide
  • Auto Tracking
  • Animated Guide
  • Faster Measurement Speed
  • Quiet and speedy auto cutting printer
  • More data on aberration measurement
With its extreme precision and accuracy, the HRK8000A uses the most advanced wavefront technology to measure the light reflected from the retina and helps you to diagnose any refractive error. With a micro lens array developed by Huvitz, the HRK creates a number of focal points, the pattern of which can give a valuable insight into the patients ocular system. The HRK not only displays the conventional data such as spherical, cylinder and axis, the high order aberration data is displayed in a graphical Zernike refractive map, giving you a deeper understanding of your patient’s eyes.Optimized Optical System Huvitz HRK-8000A Auto Refractor Keratometer A wavefront is a physical representation of the optical quality of a light beam. Using various methods, aberrometers map how light rays travel through the eye. The HR-8000A is engineered according to the Hartmann-Shack wavefront measurement technique, which is widely preferred for its speed and repeatability.Touch & Tilting Color Display Screen  A bright, high contrast 7″ VGA color TFT LCD screen provides high resolution video images. A smooth, free tilting function also offers you a comfortable and clear view at any angle.The image can then be displayed on a monitor, helping you to educate your patients The HRK can provide peripheral keratometry measurement data which is very useful when fitting contact lenses. The eye can be displayed in full colour mode on a tilting touch screen which enables you to see the patient’s contact lens fitting status, previously only possible using a slit lamp. As the HRK has the world’s first contact lens fitting function in an auto keratometer, you can now see the flourescein liquid with blue illumination along with automatic calculation and recommendation for contact lens fitting.

Erchonia Zerona Z6 SHR

The Erchonia Zerona Z6 SHR Laser is specially designed for use during non-invasive body contouring (ZERONA). The Zerona Z6 Laser is applied externally and has proven through four double-blind clinical trials to emulsify adipose tissue.Zerona-Z6 is a new body-sculpting procedure designed to target fat and contour the body without invasive surgery. Zerona-Z6 unlike other procedures, allows the client to continue their daily activities without interruptions from surgery, pain, wounds or garments.Zerona-Z6 works by utilizing the Erchonia’s patented low level laser technology to emulsify adipose tissue which then releases into the interstitial space. Our bodies remove the fat from the area and transport the fat from through the lymphatic system creating a slimming effect. The Zerona-Z6 was proven through a double-blind, randomized, multi-site, and placebo controlled study in which clients averaged a loss of 3.52* inches compared to the placebo group that lost only a half an inch.SPECIFICATIONSConfiguration: 6 Line Generated Class 2 Laser Diode Modules Wavelength: 635nm Modulation: Constant Wave (CW) Display: Full-Color TFT Touch Screen Control Center Adjustments: 1) 44” (111.76 cm) Vertical Arm Height Adjustment. 2) Four Independent Adjustable Arms for Desired Laser Concentration Power Source: 100-240VAC 50-60Hz Chassis: 1) Metal Frame Powder Coated for Ease of Cleaning 2) 4 Anti-Static Casters (2 Locking) Housing: Black Carbon Fiber Finish Thermoformed from Non-Allergen Material Weight: 70lbs. (31.76 kg) Accessories: 2-Keys, Laser Safety Glasses Compliant to Quality / ISO 13485 – Medical Device / IEC60825-1 Laser Safety, IEC 60601-1 Safety, IEC 60601-1-2 EMC, CB Mark, CB Cert FDA Laser Class 2 / FDA Device Class ll EU Device Class IIa, Laser Class IIZERONA-Z6 ADVANTAGE – No pain, no downtime and no risk – Proven effective – Superior treatment area coverage2018 Erchonia Zerona Z6 SHR, Includes: (2) Keys, Operator Eyewear, Operator Manual, Background and Protocol Guide, Marketing Materials, Female/Male Measurement Forms.Zerona-Z6 works by utilizing the Erchonia’s patented low level laser technology to emulsify adipose tissue which then releases into the interstitial space. Our bodies remove the fat from the area and transport the fat from through the lymphatic system creating a slimming effect. The Zerona-Z6 was proven through a double-blind, randomized, multi-site, and placebo controlled study in which clients averaged a loss of 3.52* inches compared to the placebo group that lost only a half an inch.

Nidek RS-330 Retina Scan Duo 2 with FAF

The Retina Scan Duo 2 is a combined OCT and fundus camera system that incorporates new features enhancing screening and clinical efficiency in addition to user-friendly features that were incorporated from the previous model.FEATURES : Nidek RS-330 Retina Scan Duo 2 with FAF
  • Fundus image acquisition with macula and disc capture in one image on OCT
  • Combined diagnosis of macular and disc pathologies
  • Wide area scan (12 x 9 mm) Wide area normative database (macula: 9 x 9 mm, disc: 6 x 6 mm): A 12 x 9 mm wide area image can be acquired. The retina map captures both the macula and disc in a single shot. The normative database provides a wide area color-coded map comparing the patient’s macular thickness to a population of normal eyes.
  • Denoising technique with deep learning: A new image enhancement technique using deep learning automatically displays a denoised image once B-scan acquisition is complete. With deep learning of a large data set of images averaged from 120 images, this denoising technique provides high definition images comparable to a multiple-image-averaging technique. The denoising function generates high definition images from a single frame while decreasing image acquisition time and increasing patient comfort.
  • Quick acquisition of high definition B-scan images from a single-frame image
  • Fundus autofluorescence (FAF): The FAF function is an advanced screening feature that allows non-invasive evaluation of the RPE without contrast dye. *Available for the FAF model
Nidek RS-330 Retina Scan Duo 2– Easy operation with 3-D auto tracking, auto shot, and user friendly interface – High definition images – Wide area scan (12 x 9 mm) / Wide area normative database (9 x 9 mm) – Multiple OCT scan patterns – Value added features – Various reports
Nidek High speed image capture OCT images are captured at scan speeds of 70,000 A-scans/s which is 32% faster than acquisition with the Retina Scan Duo™ using Regular OCT sensitivity*Wide area scan (12 x 9 mm) Wide area normative database (macula: 9 x 9 mm, disc: 6 x 6 mm) A 12 x 9 mm wide area image can be acquired. The retina map captures both the macula and disc in a single shot. The normative database provides a wide area color-coded map comparing the patient’s macular thickness to a population of normal eyes.Denoising using deep learning A new image enhancement technique using deep learning automatically displays a denoised image once B-scan acquisition is complete. With deep learning of a large data set of images averaged from 120 images, this denoising technique provides high definition images comparable to a multiple-image-averaging technique. The denoising function generates high definition images from a single frame while decreasing image acquisition time and increasing patient comfort

Righton Retinomax 5 Auto Refractor

The Retinomax Series, the world’s leading handheld autorefractor and autorefractor/keratometer, delivers wide measurement range on par with table type refr, now boasts greater mobility, stability and accuracy. The Retinomax series is widely used as a global standard device for pediatric, screening, medical care in remote areas, disaster area and wide range of ophthalmic scene.FEATURES
  • View Finder – With view finder observation, no limit of operator age. Diopter adjustable range is +/-8D the same as Retinomax3. View finder arm angle is changeable of 0-135 degrees, making measurement easy regardless of patient’s position or posture. Adjustable diopter +/- 8D.
  • Wider Eye Piece – Eye piece relief is 48mm from 32.2mm so that enable to look inside image while even looking at outside. No need to stick eye to the eyepiece all the time.
  • Improved battery life – At 180 minutes, the battery capacity is now twice that of conventional models
  • Automatic Axis Compensation and Extended Measurement Range – Not only does the device let examiner know the cylinder axis angle, but it can also be automatically adjusted if it is not level
  • New Child Mode – While the measurement is being taken, a melody plays continually to keep children’s attention. A constantly changing color display, both on the outside and inside target the device, also keeps children involved during the process.
  • Light weight and easy-to-hold grip
View Finder Righton Retinomax 5 Auto RefractorWith view finder observation, no limit of operator age. Diopter adjustable rangeis +/-8D the same as Retinomax3. View finder arm angle is changeable of 0-135degrees, making measurement easy regardless of patient’s position or posture.Adjustable diopter +/- 8D.Improved battery lifeAt 180 minutes, the battery capacity is now twice that of conventional modelsWider Eye PieceEye piece relief is 48mm from 32.2mm so that enable to look inside image while even looking at outside. No need to stick eye to the eyepiece all the time.Focus AssistLets you know the exact focusing point with the following color-coding system.New Child ModeWhile the measurement is being taken, a melody plays continually to keep children’s attention. A constantly changing color display, both on the outside and inside of the device, also keeps children involved during the process.Automatic AxisCompensation and extended measurement range Not only does the device let examiner know the cylinder axis angle, but it can also be automatically adjusted if it is not level. 
Carl Zeiss Cirrus HD-OCT 5000 Smart Advanced Topography HD

Advancing Smart OCT

for Anterior Segment, Glaucoma and Retina
  • Anterior Segment Premier Module
  • PanoMap Wide-Field Display
  • Smart HD Scans
  • En face report
Measurement centering with Foveafinder

Visualization at the speed of CIRRUS

Analyzing a single pathology from multiple views provides comprehensive insight and analysis of the clinical situation. How this helps you:
  • Spot small areas of pathology. Tightly spaced B-scans, (either 30 or 47 μm apart), in the cube ensure that small areas of pathology are imaged. For reference, a human hair is about 40-120 μm in diameter.
  • Visualize the fovea. Scans that are spaced further apart than in the CIRRUS cube may miss the central fovea.
  • Fuel for analysis. Millions of data points from the cube are fed into the Zeiss proprietary algorithms for accurate segmentation, reproducible measurements and registration for change analysis.
  • Take the pressure off the operator. As long as the scan is placed in the vicinity of the fovea or optic nerve, the software automatically centers the measurements after the capture.
  • See the tissue from different perspectives. View the cube data from all angles, with 3D rendering, OCT fundus images and Advanced Visualization™.
  • Future ready. Previously captured CIRRUS cubes can be analyzed using new analyses.
 
Measurement centering with Foveafinder

Tracking at the speed of CIRRUS

FastTrac™ reduces eye motion artifacts without sacrificing patient throughput with a proprietary scan acquisition strategy, high speed 20 Hz LSO camera, and single-pass alignment scanning With FastTrac, scan at the highest resolution at the same location at each visit.
Watch video
Measurement centering with Foveafinder

Assessment at the speed of CIRRUS

Measurement centering with FoveaFinder and AutoCenter
On the macula, the unique FoveaFinder technology ensures the ETDRS and ganglion cell plus inner plexiform layer measurement frameworks are centered on the fovea.AutoCenter™ function automatically centers the 3.4 mm diameter peripapillary RNFL calculation circle around the disc for precise placement and repeatable registration. The placement of the circle is not operator dependent. Accuracy, registration and reproducibility are assured.
Measurement centering with Foveafinder

Manage at the speed of CIRRUS Carl Zeiss Cirrus HD-OCT 5000 Smart Advanced Topography HD

Guided Progression Analysis (GPA™) for Assessing RNFL and Optic Disc Change
GPA™ compares RNFL thickness and optic disc measurements over time and determines if statistically significant change has occurred.Focal Progression Analysis – Up to 6 progression maps are compared to two baselines. Areas of statistically significant change are color-coded yellow when first noted and then red when the change is sustained over consecutive visits. Trend Analysis with Rate of Change – RNFL thickness values are plotted over time. Trends are calculated and confidence intervals are shaded when rate of change is statistically significant.
 
Nidek OPD-Scan II ARK 10000 Autorefractor KeratometerThe OPD SCAN II is the only instrument that easily combines Wavefront, Topography and Refraction all into one unit that sits on a table top! This allows the isolation of any optical problem to cornea or crystalline lens making it easy to decide if lensectomy or corneal surgery is the procedure of choice. It is also very mobile if need be!
The NIDEK OPD-Scan II provides information on corneal topography, wavefront, autorefraction, keratometry and pupillometry in one unit, utilizing state-of-the-art imaging and analysis technology developed specifically to measure normal to highly aberrated eyes. The system offers a variety of data maps to provide information on the total refractive error, wavefront, corneal shape, internal aberrations and visual quality of the eye, allowing highly accurate and reliable information for optic diagnostics.Our units are carefully refurbished, inspected and serviced by our trained technician prior to shipment.  We also offer service on almost all Nidek equipment!ARK-10000 measures the refractive condition and analyzes corneal shape of the patient’s eye.  The refractive condition is measured by weak infrared rays, and corneal shape is analyzedbased on projected placido rings onto the cornea.FinancingWe offer easy and flexible financing options on new and used ophthalmic equipment, including, Bausch & Lomb, Visx, Zeiss Humphrey, Topcon, Canon, Alcon and more! Maximize your budget and improve your bottom line with Laser Locators easy equipment financing plan. We have partnered with Stearns Bank to provide financing to our customers.Features Nidek OPD-Scan II ARK 10000 Autorefractor Keratometer – OPD Map shows point by point aberration of patient’s eye in diopters – Measurement Selection for Improved Reliability – Fast Processing Speed – Improved Accessibility to a Patient eye – Wide Measurement Range (Sphere -20.0 to +22.0D and Cylinder 0.0 to ±12.0D) – Easy Data Maintenance with a Detachable HDD – Network Capabilities – Corneal NavigatorCorneal Navigator
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
You're viewing: Huvitz HRK-8000A Auto Refractor Keratometer For Sale $3,500.00
Add to cart
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
  • Attributes
  • Custom attributes
  • Custom fields
Click outside to hide the comparison bar
Compare
Shopping cart close