15-inch touch screen that can be angled from 0 to 45 degrees
Excellent visibility for the surgeon during the procedure
Control panel with touch screen allowing the infiltrated and aspirated zones to be visualized
Control of the volume infiltrated and aspirated millimeter per millimeter in the zone selected on the touch screen
The n.i.l technique ensures an homogeneous infiltration with a constant pressure, whatever the fat density
Infiltration and aspiration data recording on USB flash memory
Compatible with the lipofilling material n.l.f System 1 & 2
In compliance with the European standards – CE marking
{tab Advantages}
Preservation of non-fatty tissues
Very easy to change zones thanks to the mapping of the different zones on the touch screen
Shorter post-procedure recovery
Less traumatising (fewer hematomas and major reduction of ecchymosis and oedemas)
Less painful for the patient
Infrasonic frequency (25 Hz) comfortable for the patient
{tab Accessories} Euromi Eva SP7 Lipomatic Liposuction Unit
Evamatic/evamatic
Control panel with touchscreen
Quantitative infiltration system
High-speed aspirator
Complete set of cannulas
Accessories
The Eva sp 7 allows a quantitative nutational infrasonic infiltration and also a nutational infrasonic liposculpture.
Manufactured for a safe liposculpture respecting the non-fatty tissues, the system is entirely digitalized
It complies with European standards (CE marking) and is compatible with N.L.F. System, our kit for lipofilling.
This product is a medical device intended for use by qualified healthcare professionals.
If you are a healthcare professional and would like more information about this product, please complete the form opposite.
If you are an individual, for more information, please refer to your healthcare professional.
Special features of Eva sp 7:
The screen provides excellent visibility for the surgeon during the procedure: infiltrated and aspirated areas.
In addition, changing zones is very easy thanks to the mapping of the different zones on the touch screen. This screen allows you to control the volume infiltrated ml / ml in the zone selected on it.
Infiltration and aspiration data can be saved on a USB drive.
Reviews (0)
Reviews
There are no reviews yet.
Be the first to review “Euromi Eva SP7 Lipomatic Liposuction Unit For Sale” Cancel reply
This system allows not only a quantitative nutational infrasonic infiltration, but also a nutational infrasonic liposculpture.Manufactured for a safe liposculpture respecting the non-fatty tissues.
Energist NeoGen PSR offers a range of treatment options, and delivers the unparalleled results your patients expect: The unique energy delivered by NeoGen is non fractionated and not dependant on a chromophore for its uptake. This provides uniform energy absorption, ensuring consistent treatment of the skin, and at high energies supporting significant tightening.
Candela GentleMAX ProEstablished in 1970, Candela is a leading US-based global medical aesthetic device company with headquarters in Wayland, Massachusetts. The company’s technologies enable physicians to provide advanced energy-based solutions for a broad range of medical-aesthetic applications including benign vascular and pigmented lesions, scars, hair removal, facial resurfacing, wrinkle reduction, women’s health treatments, tattoo removal, acne, leg veins, cellulite, and body shaping.
The Extra – 818 is the outcome of more than a decade of treatments and thousands of devices operated worldwide. It contains It contains unique features:
* Contemporary touch screen control
* Built-in Patch Test procedure for examining the optimal energy level
* A stunning number of 450,000 flashes in both lamps.
* The Large Handpiece has a Push Button in addition to the Foot Switch making
work easier and faster for the therapist.
InMode has launched, Evolve, a noninvasive hands-free workstation designed to remodel skin, treat adipose tissue and tone muscles. The Evolve delivers bipolar radiofrequency and electromagnetic pulses to treat skin and subdermal fat and improve muscle tone. Providers can use the workstation to perform Tite, Trim and/or Tone treatments, each of which can be customized to the patient’s needs.
Content
Euromi Eva SP7 Lipomatic Liposuction Unit{tab System composition}
15-inch touch screen that can be angled from 0 to 45 degrees
Excellent visibility for the surgeon during the procedure
Control panel with touch screen allowing the infiltrated and aspirated zones to be visualized
Control of the volume infiltrated and aspirated millimeter per millimeter in the zone selected on the touch screen
The n.i.l technique ensures an homogeneous infiltration with a constant pressure, whatever the fat density
Infiltration and aspiration data recording on USB flash memory
Compatible with the lipofilling material n.l.f System 1 & 2
In compliance with the European standards – CE marking
{tab Advantages}
Preservation of non-fatty tissues
Very easy to change zones thanks to the mapping of the different zones on the touch screen
Shorter post-procedure recovery
Less traumatising (fewer hematomas and major reduction of ecchymosis and oedemas)
Less painful for the patient
Infrasonic frequency (25 Hz) comfortable for the patient
{tab Accessories} Euromi Eva SP7 Lipomatic Liposuction Unit
Evamatic/evamatic
Control panel with touchscreen
Quantitative infiltration system
High-speed aspirator
Complete set of cannulas
Accessories
The Eva sp 7 allows a quantitative nutational infrasonic infiltration and also a nutational infrasonic liposculpture.Manufactured for a safe liposculpture respecting the non-fatty tissues, the system is entirely digitalizedIt complies with European standards (CE marking) and is compatible with N.L.F. System, our kit for lipofilling.This product is a medical device intended for use by qualified healthcare professionals.If you are a healthcare professional and would like more information about this product, please complete the form opposite.If you are an individual, for more information, please refer to your healthcare professional.Special features of Eva sp 7:
The screen provides excellent visibility for the surgeon during the procedure: infiltrated and aspirated areas.
In addition, changing zones is very easy thanks to the mapping of the different zones on the touch screen. This screen allows you to control the volume infiltrated ml / ml in the zone selected on it.
Infiltration and aspiration data can be saved on a USB drive.
Energist NeoGen PSR LaserNeoGen PSR SystemNeoGen nitrogen plasma technology delivers controlled heating to the skin architecture stimulating a significant physiological response, without creating an open wound. Unlike ablative technologies there is no epidermal vaporisation or charring caused at time of treatment.
Unique TechnologyNeoGen converts nitrogen gas into plasma energy, the fourth state of matter. The plasma emerges from the handpiece in controlled pulses and rapid heating of tissue occurs as it gives up its unique thermal energy to tissue.
No Open WoundsThe treated photodamaged layers undergo a controlled thermal modification, while remaining intact, creating a natural dressing to provide protection and speed healing. at high energies the epidermis sheds, but only after a new, healthier skin architecture is formed beneath.
Treats the Whole Skin ArchitectureTreating the entire skin structure ensures optimal results as the entire surface is regenerated with associated neocollagenesis and neoelastogenesis. No islands of untreated skin remain. Clinical studies show significant tightening – Mean 22% improvement in upper eyelid tightening (JOCD 7, 169-179, 2008).
Eyelids and Periorbital TreatmentEnergist NeoGen PSR is the ideal option for the treatment of the upper and lower eyelids, as well as the wider periorbital region. Other technologies cannot be used in this area or deliver inconsistent results.
Long Lasting ResultsClinical studies show neocollagenesis and reduction in elastosis continuing for more than one year post treatment.The Proven Power of Plasma for Skin Regeneration Energist NeoGen PSR Laser• Unique technology – controlled pulses of nitrogen plasma energy
• Treats the whole skin architecture – no islands of untreated skin remain
• Deep Tissue Remodelling – epidermis acts as natural dressing post treatment
• Versatile – high or low energy treatment choices to fit your patients’ needs and lifestyle
• Precise – treat eyelids effectively with significant results
• Long-lasting effects – intense fibroblast activity supports continued regeneration.
• Consistent – non-fractionated and non-chromophore dependence assures uniform energy absorption
• Proven Plasma Skin Regeneration is supported by numerous IRB-controlled studies
TechnologyPlasma skin regeneration was introduced with a level of scientific and clinical testing never before seen in the industry:
• 3+ years of pre-clinical and clinical testing
• 16 separate studies
• more than 450 clinical study treatments –No scarring or Hypopigmentation noted in studies
• one year clinical histology
This level of testing is very rare in the industryEnergist NeoGen PSR uses a highly energized gaseous state known as plasma to produce a unique thermal profile to penetrate the superficial and deeper levels of the dermis to replace damaged collagen and encourage new collagen growth for new skin. Plasma is produced inside the handpiece through the combination of inert nitrogen gas and ultra-high frequency RF.The Energist NeoGen PSR is emitted in millisecond pulses; the longer the pulse, the more energy is delivered. Nitrogen molecules impact the skin’s surface and immediately transfer energy upon contact. When the nitrogen plasma impacts the skin surface, energy is immediately transferred to the tissue. Oxygen is purged from the skin surface by the plasma, preventing carbonisation. The energy delivered to tissue ranges from 1 – 4 Joules and is user-adjustable. The repetition rate of the plasma pulses can also be controlled, and ranges from 1 – 2.5 Hertz.Specifications Energist NeoGen PSR
Power:
100 – 120 / 230 Vrms – 50/60 Hz – 650 Va
Energy Output:
Pulsed nitrogen plasma – 1-4 Joules.
Repetition Rate:
1.0 – 2.5Hz
Dimensions:
470 x 430 x 1060mm
Gas Requirement:
Medical Grade Nitrogen
System Weight:
18kg/40lb
Trolley Weight:
25kg/55lb (excludes gas tank)
Ambient Environment:
0 to 40 celsius
Relative Humidity:
30 to 75%
atmospheric pressure:
700 to 1600 hpa
Active Optical Systems Optima 518 IPL LaserHandpiece (Standard):Multipurpose Wavelength Mark-II
Handpiece (Optional):Facial Treatments
Pulse Interval/Repetition Rate:0.5 – 2 Seconds
Maximum Output Treatment Pattern:22 Joule /cm 2
Output Power:11-31 Joule / cm 2 , up to 4000 W
Cooling System:Improved Air Cooling
Control:Advanced Software Interface
Lamp’s Life Span:200,000 Flashes (minimum)
Treatment Area/Spot Size:15 x 50 mm, (7.5 cm 2)
Wavelength:420 – 1,100 nm
Weight:88.18 lbs (40Kg) (including stand)
Dimensions:17.32 inches x 17.72 inches x 39.37 inches (44cm x 45cm x 100cm)
Mains:220-230 VAC, 50/60 Hz; 100-120 VAC, 50/60 Hz
Max Mains Power:600 VA
Treatments Variety:
Skin Rejuvenation
Pigmentation Treatment
Acne Treatment
Hair Removal
Hair Removal – Deep Follicles
Hair Removal – Sensitive Skin
Vascular (Facial) Treatment
Tattoo Removal
ACTIVE OPTICAL SYSTEMS OPTIMA 518 IPL LASERr uses 12 preset programs. The programs are set in a consecutive, energy intensity increasing order, as specified by the tables of settings, covering all types of hair and skin combinations to be treated.
12 Programs
1 – Very Dark Skin, Fitzpatrick Skin Type IV
2 – Dark Skin, Fitzpatrick Skin Type IV
3 – Dark Skin, Fitzpatrick Skin Type III
4 – Dark Skin, Fitzpatrick Skin Type III
5 – Medium Skin, Fitzpatrick Skin Type II
6 – Medium Skin, Fitzpatrick Skin Type II
7 – Light Skin, Fitzpatrick Skin Type II
8 – Light Skin, Fitzpatrick Skin Type I
9 – Very Light Skin, Fitzpatrick Skin Type I
10 – Very Light Skin, Fitzpatrick Skin Type I
11 – Very Light Skin, Fitzpatrick Skin Type I
12 – High Power, Fitzpatrick Skin Type IActive Optical Systems Optima 518 IPL LaserOptima-518-Classic
The Optima – 518 Classic was designed to answer the needs of sophisticated practitioners who want to provide state of the art treatment to their patients on one hand, based on proven and tested treatment protocols and on the other hand to have the ability to reach new and improved protocols by conducting innovative clinical investigations.The Optima – 518 Classic, based on active’s GEM-PL technology, sets the pulse pattern according to the selected treatment type, skin color, skin photosensitivity and treatment depth. The treatment protocols and different pulse patterns take into account the tissue’s TRT (Thermal Relaxation Time) and the combined knowledge accumulated from thousands of treatments done during the years and clinical investigations done to confirm the findings.ACTIVE OPTICAL SYSTEMS OPTIMA 518 IPL LASERNew Handpiece Design The Optima – 518 Classic is the first model to use the new Mark II which enables a multipurpose handpiece:
* Faster treatments – up to 0.5 Seconds Between pulses.
* Real-time handpiece temperature control.
* Contemporary and stylish design.
* Light weight design – 25% less weight to improve the therapists’ comfort.Research program for clinical investigations, the self setting program allows researchers to set the treatment’s parameters according to their needs. Allowing advanced research with the device. The energy levels in the self setting program can reach 31J cm 2 with high intensity of 4000 W.ACTIVE OPTICAL SYSTEMS OPTIMA 518 IPL LASER Approvals
* CE MDD Intl. Medical Standard
* FDA U.S. Safety Standard
* ISO-13485 Med. Production STD
* IEC 60-601-1 Medical Safety STD
* CFS Gov. Health Approval
* CSA Can. & U.S. Safety App
* TGA Australian health STD.
2017 Candela GentleMAX Pro Device DetailsThe Candela GentleMax Pro yields high energy, subjecting patients to fewer laser pulses providing faster treatment times with the 24mm spot size, the largest spot found on any hair removal laser. Candela’spatented Dynamic Cooling Devise (DCD) technology protects the upper layers of skin with cooling bursts of cryogen. DCD cooling offers optimal treatment with minimal side effects.
Standard Handpiece DCD 12-18mm , Large Spot Size Handpiece DCD 22-24mm
Shot Counts
None
Wavelengths
755nm
1064nm
Consumables used by device
Windows, Distance Gauges
Consumables with purchase
3 x Operator goggles, 1 x patient goggles, distance gauges, windows
Annual Service Price
Servicing available through Candela
Service Contract Price
$11,000 per annum
Additional Information
Any additional information can be sent on request
Treatments:2017 Candela GentleMAX Pro Device Details
Hair Removal
Beard Bumps
Facial Lesions
Fine Lines and Wrinkles
Leg Veins
Skin Tightening
Vascular Lesions
Warts
Skin Rejuvenation
Hemangiomas
Birthmarks
Freckles
Melasma
Mevus of Ota
Pigmented Lesions
Sun / Age Spots
The Candela GentleMax Pro yields high energy, subjecting patients to fewer laser pulses providing faster treatment times with the 24 mm spot size, the largest spot found on any hair removal laser.Fast – With 24 mm spot size and repetition rates up to 2 Hz, the The Candela GentleMax Pro yields high energy, subjecting patients to fewer laser pulses providing faster treatment times with the 24 mm spot size, the largest spot found on any hair removal laser. It has two wavelengths, the 755 Alexandrite and the 1064 ND:yag, allowing you to offer many treatment options.Candela’s patented Dynamic Cooling Devise (DCD) technology protects the upper layers of skin with cooling bursts of cryogen. DCD cooling offers optimal treatment with minimal side effects. offers fast treatment times with it’s spot size.Powerful – 26,333 watts peak power, capable of delivering fluences up to 100 J/cm² for vascular applications, and hair removal energy in pulse duration as short as 3 ms for unparalleled treatment efficacies.Treats all skin types – Deep penetration with minimal scattering of laser energy makes the GentleMax Pro ideal for all skin types, particularly dark and tanned skin.Versatile – Non-ablative treatment, including fine lines and wrinkles, and for pseudofolliculitis barbae (PFB), or beard bumps, leg and facial veins.Patented Epidermal Cooling – Candela’s Dynamic Cooling Device represents an adjustable epidermal protection technology to maximize patient safety and comfort.Date of Manufacture – 2017Accessories Included with Purchase – Specialty 1.5, 3mm, 3x10mm Handpiece, 6, 8, 10, 12, 15, 18mm Handpiece, Full Set of Distance Gauges, Distance Gauge Case,Patient Eyewear, Treatment Goggles, Foot Pedal, Fiber Pole, System Key, System Interlock Key, Treatment Guidelines, and User Manual.
Active Optical Extra 818 IPL Skin Rejuvenation & Hair RemovalHandpieces:Integrated dual handpieces
Chilled Tip:Up to 4c
Pulse Interval:0.5-2 Seconds
Output Power:11-31 joulse/cm2, upto 4,000W
Cooling System:Revolutionary dual cooling
Control:Intuitive touch screen control
Lamp’s Life Span:250,000 Flashes (Universal) 200,000 Flashes (Facial)
Treatment Area:4.5 cm2 (15*50mm) Universal, 4.5 cm2 (15*30mm) Facial
Wavelength:420-100 nm
Weight:42Kg (including Stand)
Dimensions:44cm x 45cm x 100cmExtra-818 Active Optical Extra 818 IPL Skin Rejuvenation & Hair Removal
The Extra – 818 is the outcome of more than a decade of treatments and thousands of devices operated worldwide. It contains It contains unique features:
* Contemporary touch screen control
* Built-in Patch Test procedure for examining the optimal energy level
* A stunning number of 450,000 flashes in both lamps.
* The Large Handpiece has a Push Button in addition to the Foot Switch making
work easier and faster for the therapist.The Extra – 818, based on Active’s GEM-PL technology, sets sets a specific Pulse Pattern according to the selected treatment type, skin color, skin photosensitivity and treatment depth.
The treatment protocols and different pulse patterns take into account the tissue’s TRT (Thermal Relaxation Time) and the combined knowledge accumulated from thousands of treatments done during the years and clinical investigations done to confirm the findings.The combination of tested treatment protocols with high end engineering makes the Extra – 818 the perfect device for leading clinics.Revolutionary Cooling System
The Extra – 818 has a dual cooling system, controlled and monitored in order to ensure long lifetime to the lamp and a comfortable treatment to the patient.Competitive cooling systems “freeze” the skin so that during the treatment the skin temperature will rise to a bearable level. However, this “freezing” temperature might limit the results because the follicles will not reach the coagulation temperature. To ensure optimal results Active installed a special Processor that prevents overcooling the skin and maintains a uniform low temperature of the “glass” throughout the treatment. This revolutionary system enables the Extra – 818 to provide best results with optimal patient comfort.Research Program
For clinical investigations, the self setting program allows researchers to set the treatment’s parameters according to their needs. Allowing advanced research with the device.
The energy levels in the self setting program can reach 31Jcm2 with high intensity of 4,000W.
Inmode Evolve Body Contouring System
InMode’s EVOLVE another FDA-cleared treatment is the ideal non-invasive solution to remodel even larger body areas, and at the same time improve the appearance of your skin without surgical intervention or downtime. It’s evident that body contouring procedures are in high demand in this era as it is many people’s goal to stay fit and in shape. Body contouring in New York City is one of the most popular aesthetic treatments in the market, where in majority of cases, patients look for non-invasive procedures to improve their body shape without surgery or downtime. Evolve maximizes patient results and provides the highest quality of aesthetic treatments available.Evolve helps to modify multiple areas of the body concurrently. The areas that can be treated include the abdomen, arms, flanks, hips, thighs, knees and buttocks. This all-in-one platform delivers multiple proprietary technologies on one system and provides a variety of aesthetic treatments tailored to each body type.The next generation of non-invasive, hands-free technology, Evolve is designed to remodel skin, target adipose tissue and tone muscles. Each purpose is met with treatment that is meant for it, such as:
EVOLVE TITE: A body and skin remodeling treatment that leverages clinically proven radiofrequency technology to provide the best aesthetic outcomes. This device was developed based on the clinical success of the proprietary A.C.E. (Acquire, Control and Extend) technology. For EVOLVE TITE, bodySCULPT surgeons recommend weekly sessions of 30-60 minutes over a six to eight-week period.
EVOLVE TRIM: A quick and easy non-surgical alternative to liposuction, EVOLVE TRIM is designed specifically to reduce the unsightly appearance of cellulite. This procedure is ideal to reshape your body along with improving the appearance of the skin, reducing dimpled skin, and improving elasticity. It leverages a combination of radiofrequency energy, deep tissue heating, and vacuum design to provide maximized results. Based on your personal objectives, reliable plastic surgeons will recommend optimal number of sessions.
EVOLVE TONE: It’s ideal for those considering a non-invasive treatment to tone the muscles and address areas that require definition. EVOLVE TONE emits electromagnetic energy to stimulate involuntary muscle contractions. It’s a lunch time procedure and surgeons recommend 4 sessions of 30 minutes each to be performed over a two-week period.
Q&A for Evolve Inmode Evolve Body Contouring SystemThere is absolutely no recovery period or downtime associated with EVOKE or Evolve TITE, TONE or TRIM. Patients can return to normal activities immediately after these quick and painless treatments. Redness and warmth in the treated areas are common, which will subside after a few hours. Get the procedure done by a plastic surgeon with expertise in these treatments in an AAAASF-accredited plastic surgery practice to obtain optimal results.
Reviews