| Description | Configuration:5 3b Line Generated Laser Diode Modules
Wavelength:635nm
Modulation:Constant Wave (CW) 1,000 Hz
Programming:5 time saving presets
Display:8″ Full color TFT Touch Screen Control Center
Power Source:100-240VAC 50-60Hz
Chassis:Power Coated metal frame for ease of cleaning
Housing:Thermoformed of Non-allergen material/plastic
Accessories:2 Keys, Laser Safety Glasses
Dimensions:49 x 32 x 57H”
Weight:266 lbs. | Advanced ergonomic handpiece with multi-spot, quick-zoom cartridges, and large touch screen GUI. | Let’s Face It! We want to look our best at any age—not over-filled and over-stretched, just natural. We want to age gracefully, beautifully and elegantly. Inevitably, fine lines and wrinkles set in, and now there is a simple, minimally-invasive treatment that will address those concerns and have you out to dinner that same night. | Includes:
Footswitch
Operators Manual
AntiFreeze Coolant
Patient & Operator Eyewear | - Muscoskeletal Disorders
- Degenerative arthritis
- Rheumatoid arthritis
- Cervical pain
- Sport injuries
- Frozen shoulder
- Muscle relaxation
- Pain management
| 2017 Lumenis Lightsheer Desire with 3 Handpieces – HS, XC and ET – Includes 805 and 1060 nm wavelengths – Like-New Condition; Serial Number: 3796, Date of Manufacture 2/15/2017, Excellent Cosmetic and Operating Condition – Like New with low pulses! RECENTLY INSPECTED April 2021, Included Handpieces & Pulse Counts: HS 22×35 mm Spot Size Diode Handpiece = 132 Pulses; XC 12×12 mm Spot Size Diode Handpiece = 3,362 Pulses; ET 9×9 mm Spot Size 1060 Handpiece = 6,590 Pulses; Also Includes: Operator Manual, 2 Pair Operator Eyewear, 1 Pair Patient Eye Shields, (1) Key, and 120 Day Warranty |
| Content | ERCHONIA ZERONA Z5 LASER
The Erchonia Zerona Cosmetic Laser model is designed for use during non-invasive body contouring. It is a body sculpting machine designed to remove fat and contour the body without the invasive surgery that many patients prefer not to go under.Zerona is the only clinically-proven non-invasive body contouring treatment, providing 6 quick & painless treatments. These treatments specifically target stubborn fat areas and painlessly emulsify the fat under your skin using the Lymphatic system.ZERONA is the first non-invasive body slimming procedure to effectively remove excess fat!
Unlike other lipo and body slimming procedures, ZERONA allows patients to continue daily activities without interruptions from surgery, pain, wounds, bruises, or garments. The ZERONA protocol utilizes the Erchonia Laser Scanner, which is the safest and most researched low level laser in the world. ZERONA is also FDA approved for laser assisted liposuction. Find out how it worksVoluminous adipose tissue can appear when fatty material is present, and this, in turn, can bring about enlarged subcutaneous fat regions. Because subcutaneous fat is close to the skin’s surface, laser emulsification can have a dramatic effect on them. The collapse of adipose arrangements has been noted after laser therapy, reducing their volume and providing effective body slimming results. When the fat cells have reduced the body naturally excretes the fat over time giving the patient proven results after around six treatments over two weeks. This occurs during the bodys normal detoxification process.Configuration:5 3b Line Generated Laser Diode Modules
Wavelength:635nm
Modulation:Constant Wave (CW) 1,000 Hz
Programming:5 time saving presets
Display:8″ Full color TFT Touch Screen Control Center
Power Source:100-240VAC 50-60Hz
Chassis:Power Coated metal frame for ease of cleaning
Housing:Thermoformed of Non-allergen material/plastic
Accessories:2 Keys, Laser Safety Glasses
Dimensions:49 x 32 x 57H”
Weight:266 lbs.ERCHONIA ZERONA Z5Let’s take a closer lookERCHONIA ZERONA Z5 LASERFour separate histological studies were performed to assess the efficacy of laser in the emulsification (liquefaction) of fat. Scanning electron microscopy (SEM) and transmission electron microscopy (TEM) were utilized to analyze adipose tissue. SEM and TEM images revealed the collapse of adipose arrangements subsequent to laser therapy. The voluminous state of an adipocyte cell is reduced due to the emulsification process. The fatty material is evacuated from the cell and moves into extracellular space. The voluminous nature of adipocytes due to the accumulation of fatty material is what gives rise to an enlarged subcutaneous fat region. ZERONA induces the formation of a transitory pore in the membrane of the fat cell. The pore enables the fatty material to seep out across the aperture and into extracellular space. The following images show the result of laser energy on a single fat cell and a group of fat cells.As you can see the ZERONA treatment liquifies the fat and the cell dumps it into the intercellular space. There are two types of fat cells – Subcutaneous and Visceral.Subcutaneous fat is located directly above the skeletal muscle and below the skin. Its superficial placement is what ensures proper depth penetration of the laser energy. Patients containing a high volume of visceral fat (fat below the skeletal muscle) are not ideal candidates for this procedure. However, they may still contain subcutaneous fat; therefore, you can treat the individual by just ensuring they adopt a healthy diet to address the visceral fat. | Lutronic Clarity II
Lutronic’s Clarity II is a high-powered, dual-wavelength platform that effectively delivers a wider range of parameters to help safely and efficiently treat the broadest indications with ease. The innovative design includes: a single fiber for all spot sizes(2-25mm), intuitive interface, and no need for calibration after any parameter change. Clarity II can save time and help facilitate faster, more effective treatments.
Higher power 755/1064nm platform for effective treatments up to 45%* faster.
Brilliantly removes hair, pigment, and vascular lesions in all skin types.
IntelliTrak technology and Temperature Sensing enable increased provider confidence and treatment efficacy.Clarity II
Key Feature
1. Powerful and faster
Provide up to 25mm spot size at a useable >2 Hz
High power performance
Up to 45% faster
2. Intelligent and convenientIntelliTraking system to prevent skip area and consistent treatment
Real time skin temperature monitoring system
3. Designed for versatilityIntelligent memory function to keep track of past treatment history in detail
Zoom cartridge system for treatment areaLutronic Clarity IIHow It Works
The CLARITY II Laser System contains two separate laser resonators, Alexandrite and an Nd:YAG, which generate pulse laser energy at the nominal wavelength of 755nm and 1064nm respectively. The output of each laser generator and the 515nm aiming beam are optically combined on the laser rail so that their beam paths are identical as they exit the laser system. This allows the use of a single delivery system for either the 755nm or 1064nm wavelength.Clarity II
with IntelliTrak technologyHigher-powered 755/1064nm platform laser
Up to 2X faster Laser Hair Removal Txs*
Exclusive shorter pulsewidths available including 1ms setting
for finer facial hairs
Breakthrough intelligent capabilities
IntelliTrak technology for faster more consistent Tx coverage
Temperature Sensing for real-time skin temp feedback
during Tx
Auto-calibration in seconds saves time and
improves productivity
Advanced, easy-to-use platform
Single fiber for all 2-24mm spot cartridges
Numerous skin rejuvenation capabilities including vascular,
pigment, and toning Txs
*At settings of: 755nm, 5ms, 12J/cm2: Clarity II at 22mm, 3Hz, IntelliTrak at 18% overlap vs.
older system at 18mm, 2Hz, and est. ~18% manual overlap. Geometric treatment coverage speed is
11.4cm/second with Clarity II vs. 5.1cm/second with older system. | 2018 Vivace RF Microneedling Radio Frequency Acne ScarsTHE VIVACE EXPERIENCE
The most exciting new technology for aesthetic treatments is the combination of two methods previously used individually for skin rejuvenation, Microneedling and RF Energy. FDA-cleared for your safety, the newest generation, best-in-class Vivace RF Microneedling device, is designed for an incomparable, comfortable experience. Only Vivace boasts a precision robotic motor that brings discomfort to a virtual zero compared to any other device. The results are immediate and improve over time as well, giving you the best of both worlds. Our carefully developed recovery system ensures no one knows you just had a treatment. If you are looking for optimal results, there is no comparison to The Vivace Experience.What is Vivace Fractional RF Microneedling?
The Vivace RF Laser Radio Frequency is the newest generation of microneedling with radio frequency and is effective for fine lines and wrinkles, skin tightening, acne, acne scars, and skin tone, texture and pore size, both on and off the face. It is the most revolutionary contouring and skin tightening system for face, neck, hands and body available, producing immediate, pain-free results.Safe for all skin types, Vivace can offer similar results as ablative and fractional laser procedures, but with significantly less discomfort, downtime, and risk of complications. This revolutionary new treatment also addresses the limitations of older ‘traditional’ RF treatments and heats deeper tissues to a much higher level, which leads to greater collagen production, elastin remodeling and wound contraction previously unattainable with older technology. This is why the Vivace is a game changer in skin rejuvenation and tightening. CLICK HERE to learn moreSlate combines the best device with the newest breakthroughs in numbing, treatment serums and recovery care to create an optimal experience for you that might just keep you from needing other more invasive procedures down the road. The Vivace Experience provides the most dramatic results with less pain and less downtime. The results are both immediate and improve over time with multiple treatments. With results you can see, you’ll look and feel your best at any age.Slate Medspa is the premier Fractional RF Microneedling provider in NJ. We use the most advanced technology to provide a results-oriented skin rejuvenation program. New to Slate Medspa? Call us today at 201-477-5781 to schedule a free consultation and save 20% off your first treatment.How does Vivace Fractional RF Microneedling work?
The Vivace utilizes radio frequency and microneedling to heat the targeted area underneath the epidermis. The Vivace dramatically improves the treatment outcomes compared to other radio frequency microneedling systems.By using insulated needles, Vivace bypasses the epidermis and delivers powerful RF thermal energy to create tens of thousands of fractional coagulation zones in the dermis, facilitating a natural wound healing process. This promotes production of new collagen, remodeling of elastin and wound contraction, enhancing skin laxity. Because the thermal energy is delivered beneath the top layer of skin,Benefits of VIVACE:2018 Vivace RF Microneedling Radio Frequency Acne Scars
Minimizes/Eliminates Fine Lines and Wrinkles
Minimizes/Eliminates Acne Scars & Stretch Marks
Skin Tightening & Texture – Stimulates collagen and elastin production
Treat Sun Damage/Age Spots/Hyperpigmentation
8 Reasons why Slate LOVES Vivace™ RF Microneedling
You’ll see results quickly
Vivace works faster than any other microneedling or laser option. First, the RF Energy creates micro injuries deep in the skin in the form of a matrix. Healthy cells around the newly created matrix promote rapid healing, accelerating collagen production and skin tightening. Secondly, the invisible microchannels in the skin created by the superfine gold-tipped needles remain open for four to six hours allowing maximum absorption the key nutrients and serums applied during the treatment. This would include growth factors, HAs and other cosmeceuticals delivered to the skin in a way that no other treatment can, helping to rapidly rebuild new collagen and elastin.The average patient gets optimal results in just three treatments
Most patients experience noticeably softer, smoother and radiant skin, with improvements in tone, texture and laxity after just one treatment. We can typically achieve optimal results after only three sessions!The treatment is virtually painless
The Vivace Microneedle RF was designed for an incomparable, comfortable patient experience. The unique robotic motor is so precise, it brings the discomfort level to a virtual zero as compared to any other device. The Vivace’s ultra thin needles make it virtually pain-free. A numbing cream is applied before treatment for you to stay comfortable. Our patients here at Slate Medspa consistently report a pain level of “1” on a scale of 1 to 10.There’s no downtime
Vivace’s ultra-thin needles and robotic-assisted mechanism result in an exceptionally precise, even treatment with little-to-no bleeding. In addition, built-in LED Light therapy minimizes post-treatment redness. While we ask patients to wait until the next day before applying makeup, most feel comfortable going out without any makeup.It’s safe for almost any skin type
Patients with darker skin tones can have a more challenging time finding suitable skin resurfacing treatments, as lasers and peels that remove skin layers can risk permanent pigmentation changes. Vivace has 31 Adjustable depths, providing flexibility in treating entire depth or just down deep, bypassing damage to the top layer of skin. This means we can treat a broader array of skin types and tones with absolute precision. In addition, a variable pulse duration means the length of time the needle is engaged with tissue can be precisely controlled based on your skin profile. | ACTIVE OPTICAL EXTRA 818 IPL HAIR REMOVAL MACHINEIncludes:
Footswitch
Operators Manual
AntiFreeze Coolant
Patient & Operator EyewearHandpieces:Hair Removal Handpiece and Facial Handpiece
Chilled Tip:Up to 4c
Pulse Interval:0.5~2 Seconds
Output Power:11-31 joule/cm2, upto 4,000W
Cooling System:Revolutionary dual cooling
Control:Intuitive touch screen control
Lamp’s Life Span:250,000 Flashes (Universal), 200,000 Flashes (Facial)
Treatment Area:7.5 cm2 (15*50mm) Universal, 4.5 cm2 (15*30mm) Facial
Wavelength:420-1100 nm
Weight:42Kg (including Stand, if device is not a table top)
Dimensions:44cm x 45cm x 100cm
Extra-818
Skin Rejuvenation
Pigmentation Treatment
Acne Treatment
Hair Removal
Vascular (Facial) TreatmentThe combination of tested treatment protocols with high end engineering makes the Extra – 818 the perfect device for leading clinics.Revolutionary Cooling System
The Extra – 818 has a dual cooling system, controlled and monitored in order to ensure long lifetime to the lamp and a comfortable treatment to the patient.Competitive cooling systems “freeze” the skin so that during the treatment the skin temperature will rise to a bearable level. However, this “freezing” temperature might limit the results because the follicles will not reach the coagulation temperature. To ensure optimal results Active installed a special Processor that prevents overcooling the skin and maintains a uniform low temperature of the “glass” throughout the treatment. This revolutionary system enables the Extra – 818 to provide best results with optimal patient comfort.Research Program ACTIVE OPTICAL EXTRA 818 IPL HAIR REMOVAL MACHINE
For clinical investigations, the self setting program allows researchers to set the treatment’s parameters according to their needs. Allowing advanced research with the device.
The energy levels in the self setting program can reach 31Jcm2 with high intensity of 4,000W.The Active Optical Extra 818 IPL Hair Removal and Skin Rejuvenation is the outcome of more than a decade of treatments and thousands of devices operated worldwide. It contains It contains unique features:
* Contemporary touch screen control
* Built-in Patch Test procedure for examining the optimal energy level
* A stunning number of 450,000 flashes in both lamps.The Extra – 818, based on Active’s GEM-PL technology, sets sets a specific Pulse Pattern according to the selected treatment type, skin color, skin photosensitivity and treatment depth.
The treatment protocols and different pulse patterns take into account the tissue’s TRT (Thermal Relaxation Time) and the combined knowledge accumulated from thousands of treatments done during the years and clinical investigations done to confirm the findings. | 2020 CRYOMED HYPERMAX TALENTPRO
Electro-Magnetic Stimulation Technology
hyperMAX utilises Electro-Magnetic Stimulation technology to induce supramaximal contractions for
the growth and development of muscles. The magnetic field changes quickly inducing electrical currents in the tissue where neuronal membranes are depolarised and motor units in the target muscles are controlled to cause concentric contractions.How does it work?
Electro-Magnetic Stimulation helps to rebuild and repair muscle tissue, resulting in stronger and firmer muscles.
The strong Electro-Magnetic stimulation, of up to 3 Tesla, works deep to the hypodermis, influencing
muscle fibres and cell membranes to optimise cellular metabolism, supplying more oxygen for better blood circulation.Dualsculpt with Applicators
hyperMAX utilises Electro-Magnetic Stimulation technology to induce supramaximal contractions for the growth and development of muscles. The magnetic field changes quickly inducing electrical currents in the tissue where neuronal membranes are depolarised
and motor units in the target muscles are controlled to cause concentric contractions.2020 Cryomed HyperMAX TalentproIndications:- Muscoskeletal Disorders
- Degenerative arthritis
- Rheumatoid arthritis
- Cervical pain
- Sport injuries
- Frozen shoulder
- Muscle relaxation
- Pain management
Spinal Disorders- Acute/chronic lumbago
- Sciatica
- Spinal bifida
- Spondylitis chronic back pain
- Spinal disc disease
- Intramuscular stimulation
- Trigger Point Injection
Electro-Magnetic Stimulation TechnologyhyperMAX utilises Electro-Magnetic Stimulation technology to induce supramaximal contractions for
the growth and development of muscles. The magnetic field changes quickly inducing electrical currents in the tissue where neuronal membranes are depolarised and motor units in the target muscles are controlled to cause concentric contractions.How does it work?Electro-Magnetic Stimulation helps to rebuild and repair muscle tissue, resulting in stronger and firmer muscles.
The strong Electro-Magnetic stimulation, of up to 3 Tesla, works deep to the hypodermis, influencing
muscle fibres and cell membranes to optimise cellular metabolism, supplying more oxygen for better blood circulation. | Lumenis Lightsheer Desire (Include Handpiece)
comes fully loaded with 3 handpieces – ET (9X9), XC (12X12) & HS (22X35)the LightSheer DESIRE uses an 805nm diode wavelength. This wavelength is the industry’s Gold-Standard and has been clinically proven to safely and effectively treat all skin types Available Treatments: - Hair removal, permanent hair reduction, and the treatment for Pseudofolliculitis Barbae(PFB).
- Treatment of vascular lesions, including angiomas, hemangiomas, telangiectasia, leg veins and other benign vascular lesions.
- Treatment of benign pigmented lesions.
Unique features: - The “Gold standard” 805nm diode laser.
- 3 handpieces with various spot sizes.
- 2 advanced technologies.
The ET has a Sapphire ChillTip spot size of 9x9mm designed to treat small areas that require maximum precision and high fluence.The XC has a Sapphire ChillTip spot size of 12x12mm, providing optimal solution for large and small areas requiring higher fluence levels.The HS has a HIT 22x35mm spot size enabling use of low-fluence and a unique mechanism of pain reduction, providing safe, fast and comfortable treatment. | Product Specifications |
|---|
| ET | | | Laser Type | AIGaAs Diode Arrays | | Wavelength | 805 nm (nominal) | | Spot Size | 9 mm X 9 mm | | Repetition Rate | Up to 3 Hz | | Pulse repetition | 1 Pulse | | Fluence | 10-100 J/cm2 | | Pulse Width | 5-400 ms | | Peak Power | 1600 W | | Comfort Management | Chilltip contact cooling (5O C) | | Preset Parameters | Yse |
| XC | | | Laser Type | AIGaAs Diode Arrays | | Wavelength | 805 nm (nominal) | | Spot Size | 12 mm X 12 mm | | Repetition Rate | Up to 3 Hz | | Pulse repetition | 1 Pulse | | Fluence | 10-40 J/cm2 | | Pulse Width | 5-400 ms | | Peak Power | 2400 W | | Comfort Management | Chilltip contact cooling (5O C) | | Preset Parameters | Yse |
| HS | | | Laser Type | AIGaAs Diode Arrays | | Wavelength | 805 nm (nominal) | | Spot Size | 22 mm X 35 mm | | Repetition Rate | Up to 3 Hz | | Pulse repetition | 1 – 3 pulses | | Fluence | 4.5-12 J/cm2 | | Pulse Width | 30-400 ms | | Peak Power | 2300 W | | Comfort Management | Vacuum assisted (up to18inHg) | | Preset Parameters | Yse |
Lumenis Lightsheer Desire (Include Handpiece) – Like New |