| Description | Energist NeoGen PSR offers a range of treatment options, and delivers the unparalleled results your patients expect: The unique energy delivered by NeoGen is non fractionated and not dependant on a chromophore for its uptake. This provides uniform energy absorption, ensuring consistent treatment of the skin, and at high energies supporting significant tightening. | The Proven Power of Plasma for Skin Regeneration• Unique technology – controlled pulses of nitrogen plasma energy
• Treats the whole skin architecture – no islands of untreated skin remain
• Deep Tissue Remodelling – epidermis acts as natural dressing post treatment
• Versatile – high or low energy treatment choices to fit your patients’ needs and lifestyle
• Precise – treat eyelids effectively with significant results
• Long-lasting effects – intense fibroblast activity supports continued regeneration.
• Consistent – non-fractionated and non-chromophore dependence assures uniform energy absorption
• Proven Plasma Skin Regeneration is supported by numerous IRB-controlled studies
Technology | Includes 4 Handpieces:Erbium Yag 2940nm Handpiece for Laser Skin Resurfacing,Q-Switched Nd Yag 1064nm & 532nm Handpeice for Tattoo Removal,Diode 810nm Handpiece for Hair Removal,and IPL Handpiece for Skin Rejuvenation with 4 Filters: 650 nm of Hair Removal, 540 nm Filter for Skin Rejuvenation, 510 nm Filter for Vascular & Pigmented Lesions, and 450 nm Filter for Acne;Includes: 1 Full Day of Training, & 1 Year Manufacturer Warranty;Includes the following:1064 Nd Yag Tip, 532 KTP Tip, Tattoo Laser Goggles,2940 Erbium Yag Tip, Erbium Yag Goggles,4 IPL Filters including 650, 540, 510, and 450, IPL Goggles, | Focus Medical Naturalight IPL – Acne, Vein, Skin Rejuvenation, Hair Removal. Includes: Handpiece, (1) VR Filter – Vein & Vascular Lesion Removal, (1) AR Filter – Acne Treatment, (1) SR Filter – Skin Rejuvenation, (1) HR Filter – Hair Removal, Filter Case, Cart and 180 Day Warranty. | Fotona XP Specto, Nd:YAG laser systemFotona’s new XP Spectro laser generator is the one of the latest models of Fotona to hit the market combining the industry recognised gold standard, long=pulse and quasi-continuous wave in a single multi-application laser generator. This combination of technology allows the client to integrate non-ablative aesthetics with surgical techniques. | IDS Daeshin Shiny Photo Skin Rejuvenation & Hair Removal. Includes: (2) Handpieces with 3 Different Wavelengths Each; Handpiece #1: 415-950nm, 560-950nm & 640-950nm; Handpiece #2: 640-1200nm, 695-1200nm, & 755-1200nm; Also Includes: (2) Handpiece Holders, Power Cable, Water Refill Kit, (2) Keys, Operator Manual, (2) Operator Eyewear, Patient Eyewear and 180 Day Warranty. |
| Content | Energist NeoGen PSR LaserNeoGen PSR SystemNeoGen nitrogen plasma technology delivers controlled heating to the skin architecture stimulating a significant physiological response, without creating an open wound. Unlike ablative technologies there is no epidermal vaporisation or charring caused at time of treatment.
Unique TechnologyNeoGen converts nitrogen gas into plasma energy, the fourth state of matter. The plasma emerges from the handpiece in controlled pulses and rapid heating of tissue occurs as it gives up its unique thermal energy to tissue.
No Open WoundsThe treated photodamaged layers undergo a controlled thermal modification, while remaining intact, creating a natural dressing to provide protection and speed healing. at high energies the epidermis sheds, but only after a new, healthier skin architecture is formed beneath.
Treats the Whole Skin ArchitectureTreating the entire skin structure ensures optimal results as the entire surface is regenerated with associated neocollagenesis and neoelastogenesis. No islands of untreated skin remain. Clinical studies show significant tightening – Mean 22% improvement in upper eyelid tightening (JOCD 7, 169-179, 2008).
Eyelids and Periorbital TreatmentEnergist NeoGen PSR is the ideal option for the treatment of the upper and lower eyelids, as well as the wider periorbital region. Other technologies cannot be used in this area or deliver inconsistent results.
Long Lasting ResultsClinical studies show neocollagenesis and reduction in elastosis continuing for more than one year post treatment.The Proven Power of Plasma for Skin Regeneration Energist NeoGen PSR Laser• Unique technology – controlled pulses of nitrogen plasma energy
• Treats the whole skin architecture – no islands of untreated skin remain
• Deep Tissue Remodelling – epidermis acts as natural dressing post treatment
• Versatile – high or low energy treatment choices to fit your patients’ needs and lifestyle
• Precise – treat eyelids effectively with significant results
• Long-lasting effects – intense fibroblast activity supports continued regeneration.
• Consistent – non-fractionated and non-chromophore dependence assures uniform energy absorption
• Proven Plasma Skin Regeneration is supported by numerous IRB-controlled studies
TechnologyPlasma skin regeneration was introduced with a level of scientific and clinical testing never before seen in the industry:
• 3+ years of pre-clinical and clinical testing
• 16 separate studies
• more than 450 clinical study treatments –No scarring or Hypopigmentation noted in studies
• one year clinical histology
This level of testing is very rare in the industryEnergist NeoGen PSR uses a highly energized gaseous state known as plasma to produce a unique thermal profile to penetrate the superficial and deeper levels of the dermis to replace damaged collagen and encourage new collagen growth for new skin. Plasma is produced inside the handpiece through the combination of inert nitrogen gas and ultra-high frequency RF.The Energist NeoGen PSR is emitted in millisecond pulses; the longer the pulse, the more energy is delivered. Nitrogen molecules impact the skin’s surface and immediately transfer energy upon contact. When the nitrogen plasma impacts the skin surface, energy is immediately transferred to the tissue. Oxygen is purged from the skin surface by the plasma, preventing carbonisation. The energy delivered to tissue ranges from 1 – 4 Joules and is user-adjustable. The repetition rate of the plasma pulses can also be controlled, and ranges from 1 – 2.5 Hertz.Specifications Energist NeoGen PSR| Power: | 100 – 120 / 230 Vrms – 50/60 Hz – 650 Va | | Energy Output: | Pulsed nitrogen plasma – 1-4 Joules. | | Repetition Rate: | 1.0 – 2.5Hz | | Dimensions: | 470 x 430 x 1060mm | | Gas Requirement: | Medical Grade Nitrogen | | System Weight: | 18kg/40lb | | Trolley Weight: | 25kg/55lb (excludes gas tank) | | Ambient Environment: | 0 to 40 celsius | | Relative Humidity: | 30 to 75% | | atmospheric pressure: | 700 to 1600 hpa |
|
NeoGen PSR SystemNeoGen nitrogen plasma technology delivers controlled heating to the skin architecture stimulating a significant physiological response, without creating an open wound. Unlike ablative technologies there is no epidermal vaporisation or charring caused at time of treatment.
Unique TechnologyNeoGen converts nitrogen gas into plasma energy, the fourth state of matter. The plasma emerges from the handpiece in controlled pulses and rapid heating of tissue occurs as it gives up its unique thermal energy to tissue.
No Open WoundsThe treated photodamaged layers undergo a controlled thermal modification, while remaining intact, creating a natural dressing to provide protection and speed healing. at high energies the epidermis sheds, but only after a new, healthier skin architecture is formed beneath.
Treats the Whole Skin ArchitectureTreating the entire skin structure ensures optimal results as the entire surface is regenerated with associated neocollagenesis and neoelastogenesis. No islands of untreated skin remain. Clinical studies show significant tightening – Mean 22% improvement in upper eyelid tightening (JOCD 7, 169-179, 2008).
Eyelids and Periorbital TreatmentEnergist NeoGen PSR is the ideal option for the treatment of the upper and lower eyelids, as well as the wider periorbital region. Other technologies cannot be used in this area or deliver inconsistent results.
Long Lasting ResultsClinical studies show neocollagenesis and reduction in elastosis continuing for more than one year post treatment.The Proven Power of Plasma for Skin Regeneration• Unique technology – controlled pulses of nitrogen plasma energy
• Treats the whole skin architecture – no islands of untreated skin remain
• Deep Tissue Remodelling – epidermis acts as natural dressing post treatment
• Versatile – high or low energy treatment choices to fit your patients’ needs and lifestyle
• Precise – treat eyelids effectively with significant results
• Long-lasting effects – intense fibroblast activity supports continued regeneration.
• Consistent – non-fractionated and non-chromophore dependence assures uniform energy absorption
• Proven Plasma Skin Regeneration is supported by numerous IRB-controlled studies
TechnologyPlasma skin regeneration was introduced with a level of scientific and clinical testing never before seen in the industry:
• 3+ years of pre-clinical and clinical testing
• 16 separate studies
• more than 450 clinical study treatments –No scarring or Hypopigmentation noted in studies
• one year clinical histology
This level of testing is very rare in the industryEnergist NeoGen PSR uses a highly energized gaseous state known as plasma to produce a unique thermal profile to penetrate the superficial and deeper levels of the dermis to replace damaged collagen and encourage new collagen growth for new skin. Plasma is produced inside the handpiece through the combination of inert nitrogen gas and ultra-high frequency RF.The Energist NeoGen PSR is emitted in millisecond pulses; the longer the pulse, the more energy is delivered. Nitrogen molecules impact the skin’s surface and immediately transfer energy upon contact. When the nitrogen plasma impacts the skin surface, energy is immediately transferred to the tissue. Oxygen is purged from the skin surface by the plasma, preventing carbonisation. The energy delivered to tissue ranges from 1 – 4 Joules and is user-adjustable. The repetition rate of the plasma pulses can also be controlled, and ranges from 1 – 2.5 Hertz.Specifications PSR 2018 Energist NeoGen PSR| Power: | 100 – 120 / 230 Vrms – 50/60 Hz – 650 Va | | Energy Output: | Pulsed nitrogen plasma – 1-4 Joules. | | Repetition Rate: | 1.0 – 2.5Hz | | Dimensions: | 470 x 430 x 1060mm | | Gas Requirement: | Medical Grade Nitrogen | | System Weight: | 18kg/40lb | | Trolley Weight: | 25kg/55lb (excludes gas tank) | | Ambient Environment: | 0 to 40 celsius | | Relative Humidity: | 30 to 75% | | atmospheric pressure: | 700 to 1600 hpa |
| Sparkling Ellman Medley Multi-Platform Device 4 HPs Application: Laser skin resurfacing, skin ablation and coagulation, wrinkle and scar reduction Energy: Up to 1000 mJ Max Power: 2.4 W Pulse Width: 300 us Wavelength: 2940 nm Beam Divergence: Collimated Spot Size: 1.5 to 6 mm (with zoom lens) NOHD: >180 m Repetition Rate: up to 8 pulses per second Controls: Touch screen LCD, Footswitch Cooling: Self-Contained Closed Loop Q-Switched Nd Yag Handpiece Application: Nd Yag handpiece has two wavelengths of 1064 nm and 532 nm which are used for the treatment of vascular lesions including facial veins, telangiectasias, angiomas, hemangiomas, and pigmented lesions Energy: Up to 1000 mJ Maximum Fluence: 12 J/cm2 Wavelength: 1064 nm and 532 nm Spot Size: 1.5 to 4 mm (with zoom lens) Pulse Width: 10 to 15 ns Repetition Rate: 1 to 6 Hz NOHD: >1000 m Aiming Beam: Diode (635 nm, 10 mW Max.) Beam Delivery: Direct Controls: Touch screen LCD, Footswitch Cooling: Self-Contained Closed Loop 810 nm Diode Laser Handpiece Application: Laser Hair Removal Wavelength: 810 nm Spot Size: 10 x 14 mm Repetition Rate: 1-10 Hz Fluence: 1 to 100 J/cm2 NOHD: >30.1 m Pulse Width:Auto, 30 ms, 100 ms, 200 ms, 400 ms Accuracy: +- 10% Cooling Temperature: 0 to 5 C IPL Handpiece
Indicated Uses for 4 Filters:650 nm (HR) for Hair Removal540 nm (SR) Filter for Skin Rejuvenation510 nm (VR) Filter for Vascular & Pigmented Lesions, Melanin, Seborrheic Keratosis, & Photo Damaged Skin Lesions450 nm (AR) Filter for Acne & Atrophic Acne ScarsMaximum Fluence: 35 J/cm2 Wavelength: 450 to 1200 nm Spot Size: 35 x 15 mm Repetition Rate: 1 Pulse every 3 seconds Cooling: Self-Contained Closed Loop Indicated Uses:Sparkling Ellman Medley Multi-Platform Device 4 HPs - Tattoo Removal
- Pigmented Lesions on Skin Types -IV
- Active Acne
- Uneven Pigmentation
- Vascular Lesions
- Hair Removal
- Superficial Skin Resurfacing
- Fine Lines and Wrinkles
- Micro-Laser Peels
- Sun Damaged Skin
Ellman Medley Sparkling Multi-Platform Device 4 Handpieces SpecificationsErbium Yag Handpiece
Application:Laser skin resurfacing, skin ablation and coagulation, wrinkle and scar reduction
Energy:Up to 1000 mJ
Max Power:2.4 W
Pulse Width:300 us
Wavelength:2940 nm
Beam Divergence:Collimated
Spot Size:1.5 to 6 mm (with zoom lens)
NOHD:>180 m
Repetition Rate:up to 8 pulses per second
Controls:Touch screen LCD, Footswitch
Cooling:Self-Contained Closed Loop | Focus Medical Naturalight IPL
Focus Medical Naturalight IPL Specifications :Wavelength: 450-1200nm, IPL Pulsed Light
Energy Density: Up to 35 J/cm2
Pulse Width: Up to 200ms
Display: LCD Screen
Spot Size: 40 x 10mm2
Dimension: 35 x 45 x 26cm
Weight: 40 lbs
Power Supply: 110V 60hzManufacturer Notes
The innovative NaturaLight IPL system utilizes the latest pulsed light technology to deliver light energy at its best. The NaturaLight has all the advantages of easy operation, wide ranging applications, and a high performance to price ratio. The body of the NaturaLight is compact with variable light guides and a unique user interface to make it one of the most versatile and easy to use aesthetic systems available. The NaturaLight Pulsed Light System offers unmatched versatility, performance, and innovation.Pulsed Light or Intense Pulsed Light (IPL) is the one technology no aesthetic practice should be without. New technology and advanced techniques have continuously improved IPL efficacy, increased treatment safety, expanded the number of treatments, and generally increased the usability of this technology. Procedures such as hair removal, vascular/facial veins, and acne are effective and fast with highly successful outcomes. NaturaLight incorporates the latest in technology and new procedure techniques to provide a simple-to-use advanced pulsed light system. The NaturaLight has raised the bar with advances in both skin tightening and control of the light output.Available Wavelength FiltersHR – Hair Removal
AR – Acne Removal – Acne Treatment
SR – Skin Rejuvenation & Pigment & Pigmented Lesion Removal
ST – Skin Tightening
VR – Vein & Vascular Lesion RemovalKey BenefitsAutomatic Parameter Selection which Increases Safety and Patient Efficacy
Variable Pulsing
More Effective Use of Pulsed Light Energy
Multiple Applications
Low Cost of Ownership2017 Focus Medical Naturalight IPL – Acne, Vein, Skin Rejuvenation, Hair Removal. Includes: Handpiece, (1) VR Filter – Vein & Vascular Lesion Removal, (1) AR Filter – Acne Treatment, (1) SR Filter – Skin Rejuvenation, (1) HR Filter – Hair Removal, Filter Case, Cart and 180 Day Warranty. | Fotona XP Spectro Laser GeneratorThe Fotona XP Spectro laser offers an industry leading number of treatments from its advanced platform. The Fotona XP Spectro is an ideal choice for new clinics and clinics wishing to advance to a Fotona laser system from their current equipment.Not looking for a new Laser? See our Used-Laser Sales DirectoryThe Fotona XP Spectro laser offers high quality, fast, efficient treatments in the fields of aesthetics and surgery without compromising efficacy.The Fotona XP Spectro laser system has a 35 watt Nd:YAG engine offering different pulse configurations to be able to offer a wide range of applications at no extra cost and no need for additional hand pieces of software.Non-ablative Nd:YAG lasers are a extremely popular choice of laser in an extremely lucrative marketplace. Nd:YAG is proven as a gold standard in hair removal, skin rejuvenation, vascular treatments and much more. Fotona Xp Spectro Nd:YAG laser emits laser energy at 106nm which is proven to minimize discomfort while showing exceptional efficiently and long term results Features:Fotona XP Spectro Laser Generator
* Highest Performance
* Gold standard ND:YAG lasers
* Optional QCW Nd:YG laser
* Multiple applications
* Advanced scanner for greater Precision, Speed and Efficacy
* FRAC3 modality
* User friendly
* Massive earning potential
* Ability to treat all skin types safely and effectively Key Treatments:
* Laser Hair removal
* Rosacea treatments
* Fine wines and Wrinkles
* Laser peels
* Acne treatments
* Laser assisted lipolysis
* Laser assisted Hyperhidrosis
* Onychomycosis
* Skin tightening, tonng and texturing
* Endovenous laser
* Vascular legions
* Thread veins
* FRAC3
* Pigmentation
* Verrucae Technical Data:
* Laser wavelength:1064 nm
* Max. average power:35 W
* Pulsewidth range:PULSE: 0.1 to 50 ms, QCW: 0.1 to 2 ms
* Max. frequency:PULSE: 75 Hz, QCW*: 100 Hz
* Manual spotsizes:2 to 10 mm
* Scanner spotsizes:3 mm*, 6 mm, 9 mm*
* Scanner area:42 cm²
* Beam delivery type:Optical fiber Comes with:
* 5 Years Full Parts and Labour Warranty
* 3 pairs of laser safety goggles
* Standard Nd:YAG hanpiece (R33)
* Training and ongoing support
* Competative rates for clinic consumables | IDS Daeshin Shiny
IDS Daeshin Shiny is upgraded from the existing RPL model using our independent technology for innovative The better Photo rejuvenation & Hair removal treatment and more compact designSHINY represents the latest version of skin care equipment, which is built with the innovation technology of IDS Ltd. For safe and easy operation, the company has refined its technology and conducted clinical tests for many years.User instructionSHINY is suitable for treatment procedures for pigmented lesions, vascular lesions, acne and hair removal using basic wavelengths of 415nm, 560nm and 640nm. It can be also used for treatment of dark skin rejuvenation and hair removal by shifting to optional wavelengths of 640nm, 695nm and 755nm (ALEX Light). Wavelength can be selected very easily using a small rotator on the handpiece.Fast treatmentThe interval between each shot is shorter than that of the previous versions, and this makes the treatment easier and faster.Verified parametersBy smart protocols proper wavelength can be selected easily. The set parameters are optimized based on many clinical experiments to deliver maximal effects and safety.Advantages & Stronger points comparing to other devicesWhite toning (415nm)
Low depth of penetration (0.05~0.1mm) / High absorption (Melanin & Hemoglobin)
Safety (Fractional Concept IPL) / Excellent efficacy for faintly pigmented lesionsFractional type is our patent
Less side effects by heat (Fractional safety zone)Combine Rejuvenation (415nm 560nm) –> Amazing result in skin toning (Best in the world)Acne treatment
Fast hair removal (SHR)
ALEX (755nm) for hair removal (Best in the world)Technical FeaturesMaximal safety is achieved by Lattice technology based on fractional concepts. Lattice Optimal benefits of Lattice are provided by cutting edge technology.Traditional Spot SHINYRotating technology-based on IPL
SHINY allows easy choice of a wavelength range desired by using a rotator mounted in the hand piece. Selection of Wavelengths is easy without replacing the filter or the hand piece. (Patent No. 10-2004-0012778)Stable energy supplyA steady energy supply, which is achieved by technological expertise, allows safe operation of this beauty equipment and maximizes effects of treatment effects for each skin type.Cooling system can be controlledSemiconductor-based cooling system of SHINY can be controlled via the monitor, and maintains a steady temperature once it is set. This cooling system is aimed for minimizing pain of the patient and side effects.Light Source:Split (Intense) Pulsed Light (Xenon lamp)
Wavelength:415~950nm, 560~950nm, 640nm~950nm
Option: 640~1,200nm, 695~1,200nm
Fluence:5~40J/cmtwo
Spot Size:14.3 X 42.6mm
Pulse Sequence:Single , Double , Tripple Pulses, SHR mode
Pulse Duration:2.0 ~ 35.0ms
Pulse Delay:3.0 ~ 60.0ms
Repetition Rate:1Hz, 3Hz, 5Hz(Per Second)
Light Conduction:Quartz/ Sapphire Coupling
Cooling:Approximately up to 5℃, adjustable
Electrical Requirements:220V/16A, 50/60Hz
Physical Dimensions:360(D) X 520(L) X 1230(H)mm
Weight:60Kg2017 IDS Daeshin Shiny Photo Skin Rejuvenation & Hair Removal. Includes: (2) Handpieces with 3 Different Wavelengths Each; Handpiece #1: 415-950nm, 560-950nm & 640-950nm; Handpiece #2: 640-1200nm, 695-1200nm, & 755-1200nm; Also Includes: (2) Handpiece Holders, Power Cable, Water Refill Kit, (2) Keys, Operator Manual, (2) Operator Eyewear, Patient Eyewear and 180 Day Warranty. |