PERKASA MEDICAL

Free shipping worldwide. Orders over $200
Availability: In Stock

Energist NeoGen PSR Laser For Sale

$10,800.00

Energist NeoGen PSR offers a range of treatment options, and delivers the unparalleled results your patients expect: The unique energy delivered by NeoGen is non fractionated and not dependant on a chromophore for its uptake. This provides uniform energy absorption, ensuring consistent treatment of the skin, and at high energies supporting significant tightening.

Other people want this. 15 people have this in their carts right now.

Description

Energist NeoGen PSR Laser

NeoGen PSR System

NeoGen nitrogen plasma technology delivers controlled heating to the skin architecture stimulating a significant physiological response, without creating an open wound. Unlike ablative technologies there is no epidermal vaporisation or charring caused at time of treatment.
Unique Technology

NeoGen converts nitrogen gas into plasma energy, the fourth state of matter. The plasma emerges from the handpiece in controlled pulses and rapid heating of tissue occurs as it gives up its unique thermal energy to tissue.
No Open Wounds

The treated photodamaged layers undergo a controlled thermal modification, while remaining intact, creating a natural dressing to provide protection and speed healing. at high energies the epidermis sheds, but only after a new, healthier skin architecture is formed beneath.
Treats the Whole Skin Architecture

Treating the entire skin structure ensures optimal results as the entire surface is regenerated with associated neocollagenesis and neoelastogenesis. No islands of untreated skin remain. Clinical studies show significant tightening – Mean 22% improvement in upper eyelid tightening (JOCD 7, 169-179, 2008).
Eyelids and Periorbital Treatment

Energist NeoGen PSR is the ideal option for the treatment of the upper and lower eyelids, as well as the wider periorbital region. Other technologies cannot be used in this area or deliver inconsistent results.
Long Lasting Results

Clinical studies show neocollagenesis and reduction in elastosis continuing for more than one year post treatment.

The Proven Power of Plasma for Skin Regeneration Energist NeoGen PSR Laser

• Unique technology – controlled pulses of nitrogen plasma energy
• Treats the whole skin architecture – no islands of untreated skin remain
• Deep Tissue Remodelling – epidermis acts as natural dressing post treatment
• Versatile – high or low energy treatment choices to fit your patients’ needs and lifestyle
• Precise – treat eyelids effectively with significant results
• Long-lasting effects – intense fibroblast activity supports continued regeneration.
• Consistent – non-fractionated and non-chromophore dependence assures uniform energy absorption
• Proven Plasma Skin Regeneration is supported by numerous IRB-controlled studies
Technology

Plasma skin regeneration was introduced with a level of scientific and clinical testing never before seen in the industry:
• 3+ years of pre-clinical and clinical testing
• 16 separate studies
• more than 450 clinical study treatments –No scarring or Hypopigmentation noted in studies
• one year clinical histology
This level of testing is very rare in the industry

Energist NeoGen PSR uses a highly energized gaseous state known as plasma to produce a unique thermal profile to penetrate the superficial and deeper levels of the dermis to replace damaged collagen and encourage new collagen growth for new skin. Plasma is produced inside the handpiece through the combination of inert nitrogen gas and ultra-high frequency RF.

The Energist NeoGen PSR is emitted in millisecond pulses; the longer the pulse, the more energy is delivered. Nitrogen molecules impact the skin’s surface and immediately transfer energy upon contact. When the nitrogen plasma impacts the skin surface, energy is immediately transferred to the tissue. Oxygen is purged from the skin surface by the plasma, preventing carbonisation. The energy delivered to tissue ranges from 1 – 4 Joules and is user-adjustable. The repetition rate of the plasma pulses can also be controlled, and ranges from 1 – 2.5 Hertz.

Specifications Energist NeoGen PSR

Power:100 – 120 / 230 Vrms – 50/60 Hz – 650 Va
Energy Output:Pulsed nitrogen plasma – 1-4 Joules.
Repetition Rate:1.0 – 2.5Hz
Dimensions:470 x 430 x 1060mm
Gas Requirement:Medical Grade Nitrogen
System Weight:18kg/40lb
Trolley Weight:25kg/55lb (excludes gas tank)
Ambient Environment:0 to 40 celsius
Relative Humidity:30 to 75%
atmospheric pressure:700 to 1600 hpa

Reviews

There are no reviews yet.

Be the first to review “Energist NeoGen PSR Laser For Sale”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsEnergist NeoGen PSR Laser For Sale remove2018 Energist NeoGen PSR For Sale removeVenus Concepts Venus Velocity Laser Hair Removal System removeAsclepion Mediostar NEXT PRO XL For Sale removeCutera Xeo with Full Nd Yag and Low Pulses For Sale removeFotona XP Spectro Laser Generator For Sale remove
NameEnergist NeoGen PSR Laser For Sale remove2018 Energist NeoGen PSR For Sale removeVenus Concepts Venus Velocity Laser Hair Removal System removeAsclepion Mediostar NEXT PRO XL For Sale removeCutera Xeo with Full Nd Yag and Low Pulses For Sale removeFotona XP Spectro Laser Generator For Sale remove
Image
SKU
Rating
Price $10,800.00 $17,500.00 $8,300.00 $8,650.00 $7,600.00 $7,200.00
Stock
Availability
Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

DescriptionEnergist NeoGen PSR offers a range of treatment options, and delivers the unparalleled results your patients expect: The unique energy delivered by NeoGen is non fractionated and not dependant on a chromophore for its uptake. This provides uniform energy absorption, ensuring consistent treatment of the skin, and at high energies supporting significant tightening.The Proven Power of Plasma for Skin Regeneration• Unique technology – controlled pulses of nitrogen plasma energy • Treats the whole skin architecture – no islands of untreated skin remain • Deep Tissue Remodelling – epidermis acts as natural dressing post treatment • Versatile – high or low energy treatment choices to fit your patients’ needs and lifestyle • Precise – treat eyelids effectively with significant results • Long-lasting effects – intense fibroblast activity supports continued regeneration. • Consistent – non-fractionated and non-chromophore dependence assures uniform energy absorption • Proven Plasma Skin Regeneration is supported by numerous IRB-controlled studies Technology

Venus Concepts Venus Velocity Diode Laser Hair Removal – with largest spot size available on the market

INTEGRATED IOT TECHNOLOGY Latest data collection technology to enhance business operations Collects information to enhance business operations Helps providers with optimizing business practices and improving treatment efficiency
Asclepion Mediostar NEXT PRO XL Diode Laser with Vascular & Hair Removal Handpieces. Includes (1) Vascular Handpiece, (1) Hair Removal Handpiece with (1) XL-L tip & (1) XL- S tip; Also Includes Footswitch, (2) Keys, Water Refill Kit, Footswitch, Operator Manual, (2) Operator Eyewear, (2) Patient Eyewear and 180 Day Warranty.Cutera Xeo LaserMultiple Technologies, Maximum FlexibilityIn today’s fast-paced aesthetic practices, maximum flexibility and upgradeability are paramount. Whatever your need, the Cutera Xeo Laser can provide the most versatile laser and light technologies on the market today. Whether you are interested in, Skin Fitness, hair removal, vascular therapies – or all the above – the Xeo can accommodate your specific needs through our upgradeable platform.The Cutera Xeo Laser combines the proven effectiveness of Cutera’s long-pulse Nd:YAG laser technology with the next generation of pulsed light treatments. The Cutera XEO can offer permanent hair reduction on all skin types, a complete range of vascular treatments and the next-generation in non-ablative combination skin therapy.Fotona XP Specto, Nd:YAG laser systemFotona’s new XP Spectro laser generator is the one of the latest models of Fotona to hit the market combining the industry recognised gold standard, long=pulse and quasi-continuous wave in a single multi-application laser generator. This combination of technology allows the client to integrate non-ablative aesthetics with surgical techniques.
ContentEnergist NeoGen PSR LaserNeoGen PSR SystemNeoGen nitrogen plasma technology delivers controlled heating to the skin architecture stimulating a significant physiological response, without creating an open wound. Unlike ablative technologies there is no epidermal vaporisation or charring caused at time of treatment. Unique TechnologyNeoGen converts nitrogen gas into plasma energy, the fourth state of matter. The plasma emerges from the handpiece in controlled pulses and rapid heating of tissue occurs as it gives up its unique thermal energy to tissue. No Open WoundsThe treated photodamaged layers undergo a controlled thermal modification, while remaining intact, creating a natural dressing to provide protection and speed healing. at high energies the epidermis sheds, but only after a new, healthier skin architecture is formed beneath. Treats the Whole Skin ArchitectureTreating the entire skin structure ensures optimal results as the entire surface is regenerated with associated neocollagenesis and neoelastogenesis. No islands of untreated skin remain. Clinical studies show significant tightening – Mean 22% improvement in upper eyelid tightening (JOCD 7, 169-179, 2008). Eyelids and Periorbital TreatmentEnergist NeoGen PSR is the ideal option for the treatment of the upper and lower eyelids, as well as the wider periorbital region. Other technologies cannot be used in this area or deliver inconsistent results. Long Lasting ResultsClinical studies show neocollagenesis and reduction in elastosis continuing for more than one year post treatment.The Proven Power of Plasma for Skin Regeneration Energist NeoGen PSR Laser• Unique technology – controlled pulses of nitrogen plasma energy • Treats the whole skin architecture – no islands of untreated skin remain • Deep Tissue Remodelling – epidermis acts as natural dressing post treatment • Versatile – high or low energy treatment choices to fit your patients’ needs and lifestyle • Precise – treat eyelids effectively with significant results • Long-lasting effects – intense fibroblast activity supports continued regeneration. • Consistent – non-fractionated and non-chromophore dependence assures uniform energy absorption • Proven Plasma Skin Regeneration is supported by numerous IRB-controlled studies TechnologyPlasma skin regeneration was introduced with a level of scientific and clinical testing never before seen in the industry: • 3+ years of pre-clinical and clinical testing • 16 separate studies • more than 450 clinical study treatments –No scarring or Hypopigmentation noted in studies • one year clinical histology This level of testing is very rare in the industryEnergist NeoGen PSR uses a highly energized gaseous state known as plasma to produce a unique thermal profile to penetrate the superficial and deeper levels of the dermis to replace damaged collagen and encourage new collagen growth for new skin. Plasma is produced inside the handpiece through the combination of inert nitrogen gas and ultra-high frequency RF.The Energist NeoGen PSR is emitted in millisecond pulses; the longer the pulse, the more energy is delivered. Nitrogen molecules impact the skin’s surface and immediately transfer energy upon contact. When the nitrogen plasma impacts the skin surface, energy is immediately transferred to the tissue. Oxygen is purged from the skin surface by the plasma, preventing carbonisation. The energy delivered to tissue ranges from 1 – 4 Joules and is user-adjustable. The repetition rate of the plasma pulses can also be controlled, and ranges from 1 – 2.5 Hertz.Specifications Energist NeoGen PSR
Power:100 – 120 / 230 Vrms – 50/60 Hz – 650 Va
Energy Output:Pulsed nitrogen plasma – 1-4 Joules.
Repetition Rate:1.0 – 2.5Hz
Dimensions:470 x 430 x 1060mm
Gas Requirement:Medical Grade Nitrogen
System Weight:18kg/40lb
Trolley Weight:25kg/55lb (excludes gas tank)
Ambient Environment:0 to 40 celsius
Relative Humidity:30 to 75%
atmospheric pressure:700 to 1600 hpa

2018 Energist NeoGen PSR

NeoGen PSR SystemNeoGen nitrogen plasma technology delivers controlled heating to the skin architecture stimulating a significant physiological response, without creating an open wound. Unlike ablative technologies there is no epidermal vaporisation or charring caused at time of treatment. Unique TechnologyNeoGen converts nitrogen gas into plasma energy, the fourth state of matter. The plasma emerges from the handpiece in controlled pulses and rapid heating of tissue occurs as it gives up its unique thermal energy to tissue. No Open WoundsThe treated photodamaged layers undergo a controlled thermal modification, while remaining intact, creating a natural dressing to provide protection and speed healing. at high energies the epidermis sheds, but only after a new, healthier skin architecture is formed beneath. Treats the Whole Skin ArchitectureTreating the entire skin structure ensures optimal results as the entire surface is regenerated with associated neocollagenesis and neoelastogenesis. No islands of untreated skin remain. Clinical studies show significant tightening – Mean 22% improvement in upper eyelid tightening (JOCD 7, 169-179, 2008). Eyelids and Periorbital TreatmentEnergist NeoGen PSR is the ideal option for the treatment of the upper and lower eyelids, as well as the wider periorbital region. Other technologies cannot be used in this area or deliver inconsistent results. Long Lasting ResultsClinical studies show neocollagenesis and reduction in elastosis continuing for more than one year post treatment.The Proven Power of Plasma for Skin Regeneration• Unique technology – controlled pulses of nitrogen plasma energy • Treats the whole skin architecture – no islands of untreated skin remain • Deep Tissue Remodelling – epidermis acts as natural dressing post treatment • Versatile – high or low energy treatment choices to fit your patients’ needs and lifestyle • Precise – treat eyelids effectively with significant results • Long-lasting effects – intense fibroblast activity supports continued regeneration. • Consistent – non-fractionated and non-chromophore dependence assures uniform energy absorption • Proven Plasma Skin Regeneration is supported by numerous IRB-controlled studies TechnologyPlasma skin regeneration was introduced with a level of scientific and clinical testing never before seen in the industry: • 3+ years of pre-clinical and clinical testing • 16 separate studies • more than 450 clinical study treatments –No scarring or Hypopigmentation noted in studies • one year clinical histology This level of testing is very rare in the industryEnergist NeoGen PSR uses a highly energized gaseous state known as plasma to produce a unique thermal profile to penetrate the superficial and deeper levels of the dermis to replace damaged collagen and encourage new collagen growth for new skin. Plasma is produced inside the handpiece through the combination of inert nitrogen gas and ultra-high frequency RF.The Energist NeoGen PSR is emitted in millisecond pulses; the longer the pulse, the more energy is delivered. Nitrogen molecules impact the skin’s surface and immediately transfer energy upon contact. When the nitrogen plasma impacts the skin surface, energy is immediately transferred to the tissue. Oxygen is purged from the skin surface by the plasma, preventing carbonisation. The energy delivered to tissue ranges from 1 – 4 Joules and is user-adjustable. The repetition rate of the plasma pulses can also be controlled, and ranges from 1 – 2.5 Hertz.Specifications  PSR 2018 Energist NeoGen PSR
Power:100 – 120 / 230 Vrms – 50/60 Hz – 650 Va
Energy Output:Pulsed nitrogen plasma – 1-4 Joules.
Repetition Rate:1.0 – 2.5Hz
Dimensions:470 x 430 x 1060mm
Gas Requirement:Medical Grade Nitrogen
System Weight:18kg/40lb
Trolley Weight:25kg/55lb (excludes gas tank)
Ambient Environment:0 to 40 celsius
Relative Humidity:30 to 75%
atmospheric pressure:700 to 1600 hpa

Venus Concepts Venus Velocity Laser Hair Removal System

Laser Type: Diode Wavelength: 800nm High Peak Power:Up to 2400 W Fluence:Up to 100 J/cm2 Spot Sizes: Large 7cm2, Medium 3.5cm2, and Small 1.7cm2Experience the new gold standard in laser hair removal Ultra-fast and comfortable treatmentsTECHNOLOGY Venus Concepts Venus Velocity Laser Hair Removal System Venus Velocity, with the proven efficacy of diode laser technology, provides the optimal balance between high energy absorption of melanin chromophores and deep penetration into the skin, making it safe and effective for all skin types, including tanned skin. POWERFUL & EFFICIENT SYSTEM FOR ALL SKIN TYPES Optimal wavelength of 800 nm High peak power of 2400 W Fluence of up to 100 J/cm2ERGONOMIC APPLICATOR WITH THREE CHANGEABLE SPOT SIZES Large at 7 cm2, medium at 3.5 cm2, and small at 1.7 cm2 Each tip fits seamlessly onto the one lightweight applicator, eliminating the need for multiple applicators or bulky, expensive replacement parts for spot size flexibility Ergonomic applicator is designed for long hours of use with minimal risk of repetitive strain injury or operator fatigueVERSATILE WITH TWO MODES OF OPERATION PULSE mode delivers higher energy to tissue at a lower repetition rate, which results in higher clinical efficacy and fewer treatment sessionsSLIDE mode, wherein the applicator is smoothly and continuously moved over the treatment area, delivers high repetition rate of short pulses, which achieves high average power with full coverage and greater patient comfort. In SLIDE mode, lower power and intensive cooling with heat accumulation enable efficient treatments.The unique ability to use either mode provides unparalleled versatility and enhances operator controlREVOLUTIONARY REAL-TIME COOLING SYSTEM Monitors applicator temperature 1,000 times per second Maintains temperature throughout the session to deliver a comfortable, safe treatment No downtime for cooling translates to higher productivity for your clinicINTEGRATED IOT TECHNOLOGY Latest data collection technology to enhance business operations Collects information to enhance business operations Helps providers with optimizing business practices and improving treatment efficiency

Asclepion Mediostar NEXT PRO XL

Asclepion Mediostar NEXT PRO XL Specifications :Laser Type: Diode Peak Power: 2,400 Watts Frequency: Up to 12Hz Pulse Length: Variable (Up to 400ms) Display: 8.4” Full Color TFT Touch Screen XL-L tip Spot Size: 9.1 cm2 XL- S tip Spot Size: 3.0 cm2 Integrated Contact Skin Cooling: 360 Degrees Skin Types: Treatment of all Skin Types (I – VI), Including Tanned SkinHighest power for faster treatments With 2,400 W of power, the MeDioStar NeXT PRO XL ensures greater skin penetration, which is indispensable when epilating, in order to destroy the deepest follicles. It also allows very short pulses to be emitted at a very high frequency, thereby maximizing results, safety and comfort of the treatment.Multiple wavelengths technology The handpiece of the MeDioStar NeXT PRO XL comes in a unique combination of wavelengths. This offers physicians greater versatility in assessing the prevalence of darker or fairer phototypes among their patients. A technological innovation developed by Asclepion to satisfy the demands of its clients all over the world.Highly specialized handpieces The new MeDioStar NeXT PRO XL features the largest spot available on the market. The handpiece is provided with 2 different tips, the XL-L tip (9.1 cm2) and the XL- S tip (3.0 cm2), allowing the treatment of both larger and smaller areas. The new 360° skin-cooling system allows the highly efficient pre-cooling of the epidermis, protecting it from the risk of burns and allowing treatment in any direction. This guarantees the highest degree of comfort for both the patient and the user.Integrated high power peltier skin cooling The MeDioStar NeXT PRO XL handpiece is fitted with a system that cools the area to be treated immediately before emitting the pulse, guaranteeing greater comfort and safety for the patient during treatment. A monitoring system inside the laser device regulates the cooling level, always keeping the skin temperature low and ensuring painless and extremely delicate treatment for all skin types.Homogeneous spot for a safe and precise treatment Thanks to the TAPER technology, a special quartz fiber bundle developed by Asclepion, the laser beam is transmitted in a very uniform way, guaranteeing the even treatment of the treated areas. Thanks to the uniform distribution of energy and the square-shaped beam, there are no gaps between the spots and no zones that are hotter or cooler than others. This guarantees safe treatment with very low risk of side effects.Treatment for all skin types, all year round Thanks to the diode technology and to variable pulse length (up to 400ms), MeDioStar NeXT PRO XL allows the treatment of all skin types (I to VI), including tanned skin. The adjustable pulse duration combined with skin cooling prevents thermal damage, such as burning, to the epidermis. There is no more need to suspend the treatment during the summer and not to treat very dark skin types; thanks to MeDioStar NeXT, all patients can count on the best results.SmoothPulse mode for painless treatments at the highest speed Thanks to SmoothPulse mode, the treatment is faster than ever and still painless. With a selectable frequency up to 12Hz, MeDioStar NeXT PRO XL is the fastest hair removal system on the market.Treatment versatility The MeDioStar NeXT PRO XL goes beyond mere hair removal, also demonstrating its great versatility and user-friendliness in other fields of application, such as the removal of benign vascular lesions.Touch screen and improved software The MeDioStar NeXT PRO XL has a built-in 8.4” full color TFT touch screen display that features improved software with parameter suggestions, a picture and video library and treatment information.2015 Asclepion Mediostar NEXT PRO XL Diode Laser with Vascular & Hair Removal Handpieces. Asclepion Mediostar NEXT PRO XL Includes (1) Vascular Handpiece, (1) Hair Removal Handpiece with (1) XL-L tip & (1) XL- S tip; Also Includes Footswitch, (2) Keys, Water Refill Kit, Footswitch, Operator Manual, (2) Operator Eyewear, (2) Patient Eyewear and 180 Day Warranty. 
Cutera Xeo with Full Nd Yag and Low PulsesCutera Xeo Laser HandpiecesPearl Fractional Handpiece Features
  • Pearl Fractional has deep ablation and controlled thermal zone delivers maximum single-treatment results with less patient discomfort, downtime and risk than CO2
  • Indicated for moderate to severe photoaging
  • The 2790 nm wavelength (YSGG) controls thermal damage to maximize ablation while maintaining thermal stimulation and coagulation
  • Controlled thermal zone minimizes risk of PIH and other complications
  • Single treatment results are possible because our large 300 micron spot size ablates enough tissue in one pass
  • Wound healing causes increased fibroblast activity and long term collagen deposition. Improvement is realized over six month period.
CoolGlide Nd Yag Laser Handpiece Features and SpecificationsThe CoolGlide laser is the first laser cleared for permanent hair reduction in all skin types.
  • Treat all skin types (I-VI) including tanned skin in the summer
  • Patented PowerFlex™ technology provides fast treatments and high efficacy; allows independent control of fluence, pulse duration and repetition rates to tailor your treatment parameters
  • Copper cooling provides the most efficient method of cooling for optimal skin protection and comfort
  • Large spot size (10 mm) for maximum speed and optimal penetration at all follicle depths
  • Wavelength: 1064 nm
  • Fluence / Energy: Up to 300 J/cm2
  • Spot Size: 3 mm, 5 mm, 7 mm, 10 mm
  • Pulse Width: 0.1 – 30 msec or 10 – 100 msec
  • Repetition Rate: 2 Hz to 10 Hz
Laser Genesis Handpiece FeaturesLaser Genesis is a staple of skin care for every doctor’s practice. It is a multi-purpose, all season, all skin type solution for overall skin health
  • Cutera Xeo Laser has a 1064 nm wavelength, combined with our patented microsecond technology, protects the epidermis, targets microvasculature and stimulates collagen production
  • Improves wrinkles by gently heating the dermis; corrects diffuse redness, rosacea; smooths skin texture, shrinks pore size
  • Peer reviewed journal shows evidence of erythema reduction and new collagen formation in the papillary dermis (Archives of Dermatology, Nov 2004)
  • No downtime, minimal discomfort, no disposables.
LimeLight Handpiece Features and SpecificationsLimeLight is the most versatile, programmable device for treating vascular and pigmented lesions.
  • Three distinct preset programs (520-1100 nm) provide excellent hemoglobin and melanin absorption for uniform treatments and ease of use
  • Clinical versatility permits treatment of multiple indications, including both low and high contrast pigmentation
  • Features such as the industry’s fastest treatment speed and adjustable temperature control provide clinical versatility
  • Only company with real-time calibration; this ensures accurate and consistent power output during treatment for reproducible results and patient safety
  • Program A – 520 nm Filter – Fine Telangiectasia
  • Program B – 560 nm Filter – Telangiectasia, Pigment
  • Program C – 580 nm Filter – Solar Lentigines
  • Spot Size: 10 mm x 30 mm
  • Cooling: 5 °C, 10 °C or 20 °C
  • Fluence / Energy: 5-30 J/cm2
  • Repetition Rate: 2 Hz
AcuTip Handpiece FeaturesAcuTip delivers optimal results with targeted focal treatments of pigmented and vascular lesions–with no risk to surrounding skin.
  • Small tip allows aggressive pinpoint treatments – without compromising safety
  • Selective wavelengths (500-635 nm) with short pulse durations deliver a powerful focal treatment
  • Ideal for treatment of both low and high contrast pigmented lesions
  • As powerful as Q-switched lasers for epidermal pigmentation; low risk of associated PIH
Pearl Handpiece FeaturesPearl delivers superior results in fewer treatments with less patient downtime than with non-fractional ablative lasers.
  • Indicated for fine wrinkles, dyschromia, skin tone and texture
  • Full epidermal renewal is achieved with YSGG’s 2790 nm wavelength
  • Patients receive 1-2 treatments without weeping and oozing and recover in 3-4 days
Excel Handpiece FeaturesThe first clinically effective long-pulsed Nd:YAG laser for both facial and lower extremity vascular lesions.
  • The Excel safely and effectively treats discrete vessels, high pressure vessels and deep veins
  • Patented PowerFlex™ technology provides fast treatments and high efficacy; allows independent control of fluence, pulse duration and repetition rates to tailor your treatment parameters
  • Contact copper cooling provides the most efficient method of cooling for optimal skin protection and comfort
  • The “clearview” handpiece feature prevents vessel closure due to contact pressure
  • Easy on-the-fly spot size adjustment (3, 5, 7 mm) facilitates optimal selection for safety and results
Titan V HP (small areas) + Titan XL HP (large areas) Handpieces Features and SpecificationsTitan is the most researched and peer-reviewed infra-red solution for deep dermal heating of all skin.
  • Titan’s light source generates energy from 1100 to 1800 nm for safe and effective volumetric heating of the dermis
  • Titan candidates are often patients not yet ready for surgery
  • When combined with other non-ablative procedures that improve conditions such as dyschromia, Titan’s toning effect enhances overall results
  • Wavelength: 1100 – 1800 nm Infrared
  • Fluence / Energy: 5 to 65 J/cm2
  • Spot Size
    • Titan V – 10 mm x 15 mm
    • Titan XL – 10 mm x 30 mm
  • Tx Cycle: 4 to 10 Seconds
ProWave Hair Removal Handpiece Features and SpecificationsProWave has multiple wavelength technology switches modes from Alexandrite to Diode to near Nd:YAG for maximum results, safety and versatility—all in a single high speed device.
  • ProWave (770-1100 nm), combines unrivaled treatment speed with optimal results and safety. Maximum versatility is achieved multiple wavelength technology enabling treatment modes from Alexandrite to Diode to near Nd:YAG
  • Clinical studies showed > 80% hair reduction six months post three treatments
  • Wavelength: 770 – 1100 nm
  • Fluence: 5 to 35 J/cm2
  • Spot Size: 10 mm x 30 mm
  • Repetition Rate: 2 Hz
Cutera Xeo Laser System Specifications Cutera Xeo with Full Nd Yag and Low Pulses
  • Dimensions: 12″ W x 19″ D x 35″ H
  • System Cooling: Internal, self-contained
  • Electrical Info
    • 115 V | 60 Hz | 20A
    • 230 V | 60 Hz | 20A | 1 Phase
  • Weight: 135 lbs

Fotona XP Spectro Laser Generator

The Fotona XP Spectro laser offers an industry leading number of treatments from its advanced platform. The Fotona XP Spectro is an ideal choice for new clinics and clinics wishing to advance to a Fotona laser system from their current equipment.Not looking for a new Laser? See our Used-Laser Sales DirectoryThe Fotona XP Spectro laser offers high quality, fast, efficient treatments in the fields of aesthetics and surgery without compromising efficacy.The Fotona XP Spectro laser system has a 35 watt Nd:YAG engine offering different pulse configurations to be able to offer a wide range of applications at no extra cost and no need for additional hand pieces of software.Non-ablative Nd:YAG lasers are a extremely popular choice of laser in an extremely lucrative marketplace. Nd:YAG is proven as a gold standard in hair removal, skin rejuvenation, vascular treatments and much more. Fotona Xp Spectro Nd:YAG laser emits laser energy at 106nm which is proven to minimize discomfort while showing exceptional efficiently and long term resultsFeatures:Fotona XP Spectro Laser Generator * Highest Performance * Gold standard ND:YAG lasers * Optional QCW Nd:YG laser * Multiple applications * Advanced scanner for greater Precision, Speed and Efficacy * FRAC3 modality * User friendly * Massive earning potential * Ability to treat all skin types safely and effectivelyKey Treatments: * Laser Hair removal * Rosacea treatments * Fine wines and Wrinkles * Laser peels * Acne treatments * Laser assisted lipolysis * Laser assisted Hyperhidrosis * Onychomycosis * Skin tightening, tonng and texturing * Endovenous laser * Vascular legions * Thread veins * FRAC3 * Pigmentation * VerrucaeTechnical Data: * Laser wavelength:1064 nm * Max. average power:35 W * Pulsewidth range:PULSE: 0.1 to 50 ms, QCW: 0.1 to 2 ms * Max. frequency:PULSE: 75 Hz, QCW*: 100 Hz * Manual spotsizes:2 to 10 mm * Scanner spotsizes:3 mm*, 6 mm, 9 mm* * Scanner area:42 cm² * Beam delivery type:Optical fiberComes with: * 5 Years Full Parts and Labour Warranty * 3 pairs of laser safety goggles * Standard Nd:YAG hanpiece (R33) * Training and ongoing support * Competative rates for clinic consumables

WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
You're viewing: Energist NeoGen PSR Laser For Sale $10,800.00
Add to cart
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
  • Attributes
  • Custom attributes
  • Custom fields
Click outside to hide the comparison bar
Compare
Shopping cart close