| Content | ENDYMED PURE PLUS LASER
GOOD THINGS COMES IN SMALL PACKAGES THE PURE+
The Pure+ by Endymed Pure Plus, powered by our FDA cleared, patented 3DEEPRF technology. The PURE+ offers professional grade Fractional Skin Resurfacing and superior body, facial and neck tightening and contouring treatments, all on one easy to use, compact platform.The PURE+ offers complete flexibility with exchangeable treatment handpieces one PURE+ console can be configured any way you like to provide you and your clients with the most effective and popular treatments available today.The PURE+ is offered in two configurations:FSR + TC: Fixed FSR handpiece + one exchangeable connector suitable for all TC handpieces: iFine, Small and Large
TC Complete: Two exchangeable connectors on each side, suitable for all TC handpieces: iFine, Shaper, Small and LargeEndymed Pure Plus LaserIncludes:
iFine Handpiece
Small-Medium Handpiece
Two Exchangable Connectors on each side suitable for all handpieces
2 Keys
Infared Handheld Sensor
Operators ManualInput Power:100-120V, 50-60Hz, 2A or 220-240V, 50-60Hz, 1A
Power Consumption:220 W
Fuses:2 x 1.6A for 220V; 2 x 3.15A for 110V
Output Power:Up to 50 Watts
Output Frequency:1MHz
Working Temperature:+10°C – +25°C
Dimensions:(H x W x D) 600 x 305 x 365 mm
Weight:10 kgThe iFine treatment Handpiece –
specially engineered to target fine lines and wrinkles found in the delicate thin skin areas around the eyes, providing:
Smoother, tighter skin around the eyes.
Reduced under eye sagging and improved eye contour.
Reduced hooding to reveal more of the eyelid.
More youthful, less tired looking eyes.
Softening of fine line enabling easier application of make-up.3Deep Small-Medium Handpiece
Designed to treat wrinkles and lax skin on the face, neck and upper body.3Deep Fractional Skin Resurfacing Handpiece
Specially designed for fractional skin resurfacing and treatment of skin roughness, hyperpigmentation, and wrinkles and scars on both facial and body. The FSR handpiece contains a matrix of 112 tiny electrodes, allowing for the first time simultaneous fractional micro-ablation of the epidermis, together with volumetric heating of 100% of the dermis. This technology provides the capability to differentiate between micro-ablation and dermal heating which appears to be the optimal multi-layer treatment to affect aging skin and atrophic acne scars.3Deep Shaper Handpiece
Major innovation in RF skin tightening, body shaping and contouring, and cellulite treatment for large body areas. The handpieces unique engineered electrode surface is 40.7 cm2 allowing for shorter treatment times (20 minute abdomen treatment, 30 minute cellulite treatments for the thighs and buttocks). Deeper, controlled energy penetration tightens and firms the skin by stimulating the bodys natural collagen renewal process, providing better and more effective results. | Alma Opus Plasma Laser RF FractionalAlma Opus Plasma Laser RF Fractional Skin Resurfacing is the first-of-its-kind fractional plasma technology. It represents a new chapter for energy-based devices, addressing global or localized textural and skin quality concerns often corrected with conventional fractional resurfacing lasers in the past.Operating at a high frequency of over 40MHz, the metal pins on the Opus Plasma tips are super-charged with high-voltage. When in close proximity of the skin, the charged pins react to atmospheric pressure in the air, creating plasma that in turn, creates the microthermal zones of fractional injuries.Treatment delivers radio frequency energy at multiple levels to customize a treatment for your specific skincare concerns, using a range of settings to safely and effectively resurface the skin
Able to treat face, neck, decollete, hands, stomachs, etc.INDICATED USES
Fine Lines and wrinkles
Skin laxity
Uneven tone
Unwanted pigmentation
Stretch marks
Acne scarsWHAT IS OPUS PLASMA/HOW DOES IT WORKOpus Plasma represents a new chapter for energy-based devices, addressing global or localized textural and skin quality concerns often corrected with conventional fractional resurfacing lasers in the pastOperating at a high frequency of over 40MHz, the metal pins on the Opus Plasma tips are super-charged with high-voltage
When in close proximity of the skin, the charged pins react to atmospheric pressure in the air, creating plasma that in turn, creates the microthermal zones of fractional injuries
Our Opus treatment delivers radio frequency energy at multiple levels to customize a treatment for your specific skincare concerns, using a range of settings to safely and effectively resurface the skin
Able to treat face, neck, decollete, hands, stomachs, etc.DOES IT HURT/WHAT IS THE DOWNTIMEWe will apply a numbing cream before the treatment to make you as comfortable as possible, but you may still feel mild heat and pressure during the treatment
We also offer and highly recommend a prescription numbing cream
After a consultation, our Nurse will write you a prescription that we call in to Wellspring. This numbing cream is around $40 and allows us to turn up the machine resulting in a much better treatment
Most people tolerate the treatment well
You may experience some redness, but you can go back to your usual routine immediately after the treatment
You will appear to have a sunburn look
Your specialists will talk to you about aftercare at your consultation | ACTIVE OPTICAL EXTRA 818 IPL HAIR REMOVAL MACHINEIncludes:
Footswitch
Operators Manual
AntiFreeze Coolant
Patient & Operator EyewearHandpieces:Hair Removal Handpiece and Facial Handpiece
Chilled Tip:Up to 4c
Pulse Interval:0.5~2 Seconds
Output Power:11-31 joule/cm2, upto 4,000W
Cooling System:Revolutionary dual cooling
Control:Intuitive touch screen control
Lamp’s Life Span:250,000 Flashes (Universal), 200,000 Flashes (Facial)
Treatment Area:7.5 cm2 (15*50mm) Universal, 4.5 cm2 (15*30mm) Facial
Wavelength:420-1100 nm
Weight:42Kg (including Stand, if device is not a table top)
Dimensions:44cm x 45cm x 100cm
Extra-818
Skin Rejuvenation
Pigmentation Treatment
Acne Treatment
Hair Removal
Vascular (Facial) TreatmentThe combination of tested treatment protocols with high end engineering makes the Extra – 818 the perfect device for leading clinics.Revolutionary Cooling System
The Extra – 818 has a dual cooling system, controlled and monitored in order to ensure long lifetime to the lamp and a comfortable treatment to the patient.Competitive cooling systems “freeze” the skin so that during the treatment the skin temperature will rise to a bearable level. However, this “freezing” temperature might limit the results because the follicles will not reach the coagulation temperature. To ensure optimal results Active installed a special Processor that prevents overcooling the skin and maintains a uniform low temperature of the “glass” throughout the treatment. This revolutionary system enables the Extra – 818 to provide best results with optimal patient comfort.Research Program ACTIVE OPTICAL EXTRA 818 IPL HAIR REMOVAL MACHINE
For clinical investigations, the self setting program allows researchers to set the treatment’s parameters according to their needs. Allowing advanced research with the device.
The energy levels in the self setting program can reach 31Jcm2 with high intensity of 4,000W.The Active Optical Extra 818 IPL Hair Removal and Skin Rejuvenation is the outcome of more than a decade of treatments and thousands of devices operated worldwide. It contains It contains unique features:
* Contemporary touch screen control
* Built-in Patch Test procedure for examining the optimal energy level
* A stunning number of 450,000 flashes in both lamps.The Extra – 818, based on Active’s GEM-PL technology, sets sets a specific Pulse Pattern according to the selected treatment type, skin color, skin photosensitivity and treatment depth.
The treatment protocols and different pulse patterns take into account the tissue’s TRT (Thermal Relaxation Time) and the combined knowledge accumulated from thousands of treatments done during the years and clinical investigations done to confirm the findings. | EMVERA CLARO2 CO2 LASER
Claro2 Medical Laser System
The Claro2 laser technology offers the most innovative approach to laser treatments today. It provides an acceptable and comfortable procedure under little or no anesthesia with minimum pain from evaporation of the skin layers, resulting in minimal social or work downtime. The laser delivers a series of microscopic, closely-spaced laser spots to the skin while simultaneously preserving the normal, healthy skin. The undamaged skin becomes a reservoir of tissue for fast heating and regeneration of the treated area by producing and providing new dermal collagen and eliminating epidermal pigmentation and irregularities to the skin tone. The Claro2 laser system is specially designed to improve skin texture and tone, and fight wrinkles, scars and pigmentations. Since the treatment procedures are customized to patients skin, operators are able to adjust laser settings to tailor treatments and achieve superior results.Claro2 Laser Features Provide:
Unparalleled char-free ablation, vaporization, excision, or incision of soft tissues
Reduced thermal damage to surrounding tissues
Rapid healing and minimal downtime
Stimulation of deeper collagen with high pulse energy
Large TFT LCD touch screen provides easy operation with the latest high speed microprocessor technology
Adjustable scanning patterns and sizes
Adjustable intensity of pilot beam
Adjustable pulse duration
Last treatment setting memorization
Automatic alarm system for operation and errors
No consumable costsIncludes:
1 Fractional Scanner Handpiece for Ablative Skin Resurfacing
1 Incisional Handpiece with up to or less than .2mm Spot Size
Handpiece Case
Distance Gauges
Footswitch
Patient Eyewear
Operator Eyewear
Operator Manual
Warning SignLaser Type:Sealed of Co2 Laser
Wavelength:10.6 um
Mode Structure:TEM00
Max Power:0-30W (adjustable)
Spot Size:Equal to or less than .2mm
Aiming Beam:630nm Red Laser (Adjustable Brightness)
Delivery System:Articulated Arm
Operation Modes:Continuous Wave, Single Pulse, Repetition Pulse, Super Pulse, Scanner
Pulse Width:Single Pulse (0.01-1s); Repetition Pulse (0.001-1s); Scanner (0.0001-0.01s)
Scan Size: Adjustable
Scan Pattern:Oval, Triangle, Rectangle, Line
Scan Array Density:Adjustable
Cooling System:Self-Contained, Closed Cycle
Power Supply:100-120V AC, 50/60Hz or 200-240V AC, 50/60Hz
Environment Temperature:10-40 Degrees Celsius
Relative Humidity:Below 80%
Dimensions:561mm x 500mm x 1443mm
Weight:42kgApplications Include:EMVERA CLARO2 CO2 LASERDermatology, Plastic Surgery and General Surgery procedures including but not limited to:
Laser skin resurfacing
Treatment of furrows and wrinkles
Removal of skin tags, actinic keratosis, acne scars, keloids, tattoos, telangiectasia, squamous and basel cell carcinoma, warts and uneven pigmentation
Treatment of cysts, abscesses, hemorrhoids and other soft tissue applications
Blepharoplasty
Site preparation for hair transplantsOtorhinolaryngology (ENT) procedures including but not limited to:
Treatment of leukoplakia of larynx, nasal obstruction, rhinophyma, verrucrea vulgares, choanal atresia, rhinophyma, LAUP and papillomatosis polypsGynecology:
Treatment of condyloma acuminate, cervical
intraepithelial neoplasia, leukoplakia and vulvar/
vaginal intraepithelial neoplasia, cervical dysplasia
Podiatry procedures including but not limited to:
Ablation, vaporization and excision of soft
tissue lesions such as ingrown nail, fungal nail,
porokcratoma, matrixectomy and verrucae vulgares | LUMENIS POLLOGEN LEGEND PRO
Skin treatments platform with unique RF assist ultra-thin electrodes and TriPollar RFThe Legend Pro system intended for dermatological procedures requiring ablation and resurfacing of the skin when using VoluDerm Energy (Applicator VO). It is also intended for use in dermatologic and general surgical procedures for the non-invasive treatment of mild to moderate facial wrinkles and rhytides when using TriPollar RF Energy (Applicators 1-3) Intended settings for the device: Clinics & Hospitals.Radio-frequency (RF) MicroneedlingAdvancements in radio-frequency give providers the ability to treat new patient segments. Legend Pro is our skin treatments platform with clinically proven technologies that target the specific needs of each patient, while NuEra Tight provides personalized RF deep heating for smoother skin, head to toe.Includes:
3 Radio Frequency Handpieces
1 Radio Frequency MicroNeedling Handpiece
Footswitch
Operators ManualLegend ProSkin treatments platform with unique RF assist ultra-thin electrodes and TriPollar RFImagine a treatment with immediate results, long term efficacy, minimal pain and downtime, and no need for numbing… Sounds too good to be true?
Legend Pro is all that, and more.Patients benefitsOffer your patients Legend Pro’s synergetic technologies, providing endless options for personalized treatment plans, targeted at answering the specific needs and desires of each patient.By encouraging and enhancing the natural healing processes in the skin, Legend Pro unveils the best in each patient. From resurfacing of the upper layers of the skin to promoting the regeneration of collagen and elastin fibers in the deeper dermis, Legend Pro offers a complete toolkit for creating tailor-made treatments and personalized results for your patients.Input Voltage:100-2400 Volt,50-60Hz, max 2.2A
Mode of Operation:VoluDerm, TriFractional, Tripollar
Maximum Output Power RF:50 Watts @ 200 Ohm
Maximum Output Voltage:100 Plus or Minus 10 Vrms
Output Frequency RF:1Mhz
Output Power Control RF:Pulse Width Modulation (PWM)
Weight: 66 Kgs
Dimensions:L1.5 x W1.5 x H3.6 Inch
Environmental Conditions for Operation
Temperature:15 Degrees Celsius to +30 Degrees Celsius (59-86 Degrees Farrenheit)
Relative Humidity:Up to 80%; Non- Condensing
Atmospheric Pressure: 70-106 kPa
Maximum Altitude:2000 Meters
Environmental Conditions for Transportation & Storage
Temperature:-20 Degrees Celsius to + 55 Degrees Celsius (-4-131 Degrees Farrenheit)
Relative Humidity:80%; Non-Condensing
Atmospheric Pressure:50-106 kPa
Maximum Altitude:2000 MetersLumenis Pollogen Legend ProClinically proven RF thermal skin regeneration technologyLegend Pro’s clinically proven technologies work in synergy to achieve the results you and your patients seek.TriPollar RF ApplicatorsTriggering regeneration of collagen and elastin fibers, by delivering focused RF energy in a safe and effective manner, inducing controlled heating of the deep dermisVoluDermActivating the body’s natural healing processes by applying RF-assisted ultra-thin electrodes to thermally ablate the epidermis, creating micro channels to induce controlled micro wounds, thus encouraging the generation of new and healthy skin.TriFractionalApplying contact RF and pin point ablation with controlled volumetric heating to achieve skin resurfacing and regeneration via wound healing process, resulting in skin texture improvement and refinement.Legend M² unique synergized treatment combines the macro volumetric heating of tissue with TriPollar RF and the precise micro heating of focal points with VoluDerm RF assisted ultra-thin electrodes. Treatments with Legend M²™ reaches multiple layers of the skin introducing a wide range of solutions for skin resurfacing and inducing regeneration as well as wrinkle reduction.Thanks to the unique technologies behind Legend Pro, patients experience minimal pain and downtime during and after treatment, without the need of numbing cream before the treatment. The desired results are promptly visible. Indications include: skin resurfacing and treatment of mild to moderate wrinkles and rhytids.POLLOGEN LEGEND IS AN ADVANCED MEDICAL AESTHETIC PLATFORM INCORPORATING THE LEADING INDUSTRY TECHNOLOGIES – HYBRID ENERGY TECHNOLOGY, TRILIPO USING NON-INVASIVE TRIPOLLAR RF ENERGY, AND DYNAMIC MUSCLE ACTIVATION. THE COMBINATION OF THESE TECHNOLOGIES PROVIDES EFFECTIVE DERMAL VOLUMIZING, SKIN TIGHTENING, AND BODY SCULPTING.Treatment with the Pollogen LEGEND device is effective and fast with minimal discomfort. It is suitable for all skin types and ethnicities and carried out in a simple ‘walk-in walk-out’ treatment with minimal downtime.-Visible results after the 1st treatment-Long-term measurable results-Minimal discomfort, minimal downtime-Easy to use with a fast learning curve | 2017 Lumenis M22 IPL with ResurFX| Manufacturer Notes |
|---|
| M22 is a modular multi-application platform for the treatment of over 30 skin conditions and hair removal.Available Treatments with M22:– Acne Scar Treatment
– Hair Removal
– Non-Ablative Skin Resurfacing
– Photorejuvenation
– Pigmentation Treatment
– Scar Revision
– Vascular / Leg Vein Treatment
– Dark Tattoo RemovalUsed by physicians around the world, M22 enables you to treat more types of patients and conditions with better outcomes.4 Multiple Technologies In One Modular SystemM22 grows with your practice and can expand to your treatment needs and adapts to future applications as they emerge.Universal IPL
Optimal Pulse Technology (OPT)
Single handpiece with changeable filters and lightguides
For IPL skin treatments using photorejuvenationResurFX
The only True fractional non-ablative, with CoolScan scanner
No disposables
For skin resurfacingMulti-Spot Nd:YAG
The only one with Multiple Sequential Pulsing (MSP)
2 sized lightguides, changeable in seconds
For treatment of leg veins and vascular lesionsQ-Switched Nd:YAG
Homogenous beam profile for enhanced treatment safety and efficacy
For skin toning*, dark tattoos removal, and combination treatments
*Skin toning by treatment of pigmented lesions |
2017 Lumenis M22 IPL with ResurFX and Q-Switched Nd:YAG A modular multi-application system for hair removal and various skin conditions Details:M22 Serial Number: 21171 M22 Date of Manufacture: 2017-07-17 Total IPL Pulses: 19,186 Total ResurFX Pulses: 10,772 Q-Switched Nd:YAG Pulses: 385,505
Includes:IPL Handpiece Complete Standard IPL filters: 515, 560, 590, 615, 640, 695, 755nm, and Calibration Specialty IPL Filters: Acne and Vascular IPL Light Guides: (1)35 x 15 mm2; (1)15 x 8 mm2, (1) 6mm- round ResurFX Handpiece with SapphireCool Tip Q-Switched Nd:YAG Handpiece Foot Switch Power Cord 30 Days Parts and Labor Warranty
|
System specifications
Dimensions:[without ResurFX] 44 x 50.5 x 47 cm (17 x 20 x 18.5 inches)
Dimensions:[with ResurFX] 44 x 50.5 x 61.5 cm (17 X 20 X 24 inches)
Weight:[without ResurFX] 40 kg / 88 lbs
Weight:[with ResurFX] 55 kg / 121 lbs
Electrical requirements:100 240 VAC ±10%, 15A max., 50/60 Hz, single phase, dedicated line M22 is a modular multi-application platform for the treatment of over 30 skin conditions and hair removal. Available Treatments with M22:– Acne Scar Treatment
– Hair Removal
– Non-Ablative Skin Resurfacing
– Photorejuvenation
– Pigmentation Treatment
– Scar Revision
– Vascular / Leg Vein Treatment
– Dark Tattoo RemovalUsed by physicians around the world, M22 enables you to treat more types of patients and conditions with better outcomes.4 Multiple Technologies In One Modular SystemM22 grows with your practice and can expand to your treatment needs and adapts to future applications as they emerge. Universal IPL
Optimal Pulse Technology (OPT)
Single handpiece with changeable filters and lightguides
For IPL skin treatments using photorejuvenation ResurFX
The only True fractional non-ablative, with CoolScan scanner
No disposables
For skin resurfacing Multi-Spot Nd:YAG
The only one with Multiple Sequential Pulsing (MSP)
2 sized lightguides, changeable in seconds
For treatment of leg veins and vascular lesions |
Reviews
There are no reviews yet.