| Content | ENDYMED PURE PLUS LASER
GOOD THINGS COMES IN SMALL PACKAGES THE PURE+
The Pure+ by Endymed Pure Plus, powered by our FDA cleared, patented 3DEEPRF technology. The PURE+ offers professional grade Fractional Skin Resurfacing and superior body, facial and neck tightening and contouring treatments, all on one easy to use, compact platform.The PURE+ offers complete flexibility with exchangeable treatment handpieces one PURE+ console can be configured any way you like to provide you and your clients with the most effective and popular treatments available today.The PURE+ is offered in two configurations:FSR + TC: Fixed FSR handpiece + one exchangeable connector suitable for all TC handpieces: iFine, Small and Large
TC Complete: Two exchangeable connectors on each side, suitable for all TC handpieces: iFine, Shaper, Small and LargeEndymed Pure Plus LaserIncludes:
iFine Handpiece
Small-Medium Handpiece
Two Exchangable Connectors on each side suitable for all handpieces
2 Keys
Infared Handheld Sensor
Operators ManualInput Power:100-120V, 50-60Hz, 2A or 220-240V, 50-60Hz, 1A
Power Consumption:220 W
Fuses:2 x 1.6A for 220V; 2 x 3.15A for 110V
Output Power:Up to 50 Watts
Output Frequency:1MHz
Working Temperature:+10°C – +25°C
Dimensions:(H x W x D) 600 x 305 x 365 mm
Weight:10 kgThe iFine treatment Handpiece –
specially engineered to target fine lines and wrinkles found in the delicate thin skin areas around the eyes, providing:
Smoother, tighter skin around the eyes.
Reduced under eye sagging and improved eye contour.
Reduced hooding to reveal more of the eyelid.
More youthful, less tired looking eyes.
Softening of fine line enabling easier application of make-up.3Deep Small-Medium Handpiece
Designed to treat wrinkles and lax skin on the face, neck and upper body.3Deep Fractional Skin Resurfacing Handpiece
Specially designed for fractional skin resurfacing and treatment of skin roughness, hyperpigmentation, and wrinkles and scars on both facial and body. The FSR handpiece contains a matrix of 112 tiny electrodes, allowing for the first time simultaneous fractional micro-ablation of the epidermis, together with volumetric heating of 100% of the dermis. This technology provides the capability to differentiate between micro-ablation and dermal heating which appears to be the optimal multi-layer treatment to affect aging skin and atrophic acne scars.3Deep Shaper Handpiece
Major innovation in RF skin tightening, body shaping and contouring, and cellulite treatment for large body areas. The handpieces unique engineered electrode surface is 40.7 cm2 allowing for shorter treatment times (20 minute abdomen treatment, 30 minute cellulite treatments for the thighs and buttocks). Deeper, controlled energy penetration tightens and firms the skin by stimulating the bodys natural collagen renewal process, providing better and more effective results. | EMVERA CLARO2 CO2 LASER
Claro2 Medical Laser System
The Claro2 laser technology offers the most innovative approach to laser treatments today. It provides an acceptable and comfortable procedure under little or no anesthesia with minimum pain from evaporation of the skin layers, resulting in minimal social or work downtime. The laser delivers a series of microscopic, closely-spaced laser spots to the skin while simultaneously preserving the normal, healthy skin. The undamaged skin becomes a reservoir of tissue for fast heating and regeneration of the treated area by producing and providing new dermal collagen and eliminating epidermal pigmentation and irregularities to the skin tone. The Claro2 laser system is specially designed to improve skin texture and tone, and fight wrinkles, scars and pigmentations. Since the treatment procedures are customized to patients skin, operators are able to adjust laser settings to tailor treatments and achieve superior results.Claro2 Laser Features Provide:
Unparalleled char-free ablation, vaporization, excision, or incision of soft tissues
Reduced thermal damage to surrounding tissues
Rapid healing and minimal downtime
Stimulation of deeper collagen with high pulse energy
Large TFT LCD touch screen provides easy operation with the latest high speed microprocessor technology
Adjustable scanning patterns and sizes
Adjustable intensity of pilot beam
Adjustable pulse duration
Last treatment setting memorization
Automatic alarm system for operation and errors
No consumable costsIncludes:
1 Fractional Scanner Handpiece for Ablative Skin Resurfacing
1 Incisional Handpiece with up to or less than .2mm Spot Size
Handpiece Case
Distance Gauges
Footswitch
Patient Eyewear
Operator Eyewear
Operator Manual
Warning SignLaser Type:Sealed of Co2 Laser
Wavelength:10.6 um
Mode Structure:TEM00
Max Power:0-30W (adjustable)
Spot Size:Equal to or less than .2mm
Aiming Beam:630nm Red Laser (Adjustable Brightness)
Delivery System:Articulated Arm
Operation Modes:Continuous Wave, Single Pulse, Repetition Pulse, Super Pulse, Scanner
Pulse Width:Single Pulse (0.01-1s); Repetition Pulse (0.001-1s); Scanner (0.0001-0.01s)
Scan Size: Adjustable
Scan Pattern:Oval, Triangle, Rectangle, Line
Scan Array Density:Adjustable
Cooling System:Self-Contained, Closed Cycle
Power Supply:100-120V AC, 50/60Hz or 200-240V AC, 50/60Hz
Environment Temperature:10-40 Degrees Celsius
Relative Humidity:Below 80%
Dimensions:561mm x 500mm x 1443mm
Weight:42kgApplications Include:EMVERA CLARO2 CO2 LASERDermatology, Plastic Surgery and General Surgery procedures including but not limited to:
Laser skin resurfacing
Treatment of furrows and wrinkles
Removal of skin tags, actinic keratosis, acne scars, keloids, tattoos, telangiectasia, squamous and basel cell carcinoma, warts and uneven pigmentation
Treatment of cysts, abscesses, hemorrhoids and other soft tissue applications
Blepharoplasty
Site preparation for hair transplantsOtorhinolaryngology (ENT) procedures including but not limited to:
Treatment of leukoplakia of larynx, nasal obstruction, rhinophyma, verrucrea vulgares, choanal atresia, rhinophyma, LAUP and papillomatosis polypsGynecology:
Treatment of condyloma acuminate, cervical
intraepithelial neoplasia, leukoplakia and vulvar/
vaginal intraepithelial neoplasia, cervical dysplasia
Podiatry procedures including but not limited to:
Ablation, vaporization and excision of soft
tissue lesions such as ingrown nail, fungal nail,
porokcratoma, matrixectomy and verrucae vulgares | 2019 Lumenis Splendor X- Laser Hair Removal
Lumenis Splendor X Laser Hair RemovalThe Alexandrite wavelength at 755 nm, which is ideal for treating skin tones 1, 2 and 3 (fair and light skin tones). It is highly absorbed in melanin and is therefore not safe for use on darker skin tones.
The Nd:YAG wavelength at 1064 nm, which is ideal for treating skin tones 4, 5 and 6 (4 being tanned skin and 5 and 6 darker skin tones) as the absorption by melanin is much lower than with the Alexandrite wavelengthThe Lumenis Splendor X has been introduced to be a player in the solid state Nd:YAG and Alexandrite laser hair removal market. The gold standard for hair removal has always been considered Alexandrite 755nm for light skins and Nd:YAG 1064nm for dark skins.The Lumenis Splendor X combines both in a unique way with blended emission.Instead of firing a single wavelength at a time the Splendor X allows you to fire both wavelengths simultaneous in adjustable amounts to suit the skin type and hair types. This means you are target multiple chromophores at any given time given enhanced results across the board.The Lumenis Splendor X also allows the user to choose between square and round spot sizes with large spot sizesLumenis Splendor X Laser Hair RemovalThe Alexandrite wavelength at 755 nm, which is ideal for treating skin tones 1, 2 and 3 (fair and light skin tones). It is highly absorbed in melanin and is therefore not safe for use on darker skin tones.
The Nd:YAG wavelength at 1064 nm, which is ideal for treating skin tones 4, 5 and 6 (4 being tanned skin and 5 and 6 darker skin tones) as the absorption by melanin is much lower than with the Alexandrite wavelengthLaser Hair Removal
Details:2019 Lumenis Splendor X- Laser Hair Removal- Serial Number: SQEAY-19M-XXXXX (message for serial number)
- System Total Shot Count: 560,693
- Alex Shot Count: 221,437
- YAG Shot Count: 339,256
Includes:- Handpiece and Delivery System
- Square Spot Sizes: 2x2mm, 3x3mm, 5x5mm, 10x10mm, 14x14mm, 18x18mm, 20x20mm, 24x24, 27x27mm
- Fiber Pole
- Foot Switch
- System Key
- Operators Manual
- 30 Day Parts and Labor Warranty
| ELLMAN PELLEVE S5 REDUCTION SYSTEM
The Pelleve S5 System is a new generator based on the proven Surgitron technology. In addition to powering the Pelleve handpieces, it provides maximum control in precision cutting with minimal thermal damage to surrounding tissues, plus more versatility than other energy-based technologies, including:Wrinkle reduction treatment with the new GlideSafe(TM) handpieces
Hundreds of surgical electrodes and accessories for most specialties
Portable and light weight – ideal for office and clinic environmentsWxHxD: 9.5 x 7.1 x 16.5
Weight: 26 lbs.
Ambeint Temperature: +10 degrees C – +40 degrees C
Relative Humidity: 30% – 75%
Normal Line Voltage: 100V, 120V / 220V, 240V – + 10%
Line Frequency: 60Hz./50Hz.
Input current at max output power: 3.4A/1.5A
Pelleve Wrinkle Reduction System
Ellagance Through Science
Pelleve S5 SystemPelleve precisely delivers energy to the dermal tissue using advanced radiofrequency technology to induce collagen contraction without damaging the epidermis. The result is skin tightening and contouring with a noticeable improvement in skin quality and texture.Pelleve’s unique radiofrequency technology emits energy in the form of electromagnetic waves, which create a heated treatment zone. Increased resistance causes heat buildup at the subdermal junction. Heat induces collagen denaturation and collagen contraction. Protein stimulation causes new collagen formation and production in the dermis which also results in epidermal tightening. Existing bands of collagen tighten in subcutaneous fat, creating a superficial tightening of the epidermis.Unparalleled Safety ELLMAN PELLEVE S5 REDUCTION SYSTEM
The Pelleve System delivers continuous radiofrequency energy which enables the clinician to choose how much energy to deliver and in what areas. By using a combination of the different sizes of Pelleve handpieces that are available each patient’s specific areas of concern can be addressed, resulting in patients receiving just the right amount of energy. The new GlideSafe handpieces feature an innovative sensor designed to stop energy flow when the device senses loss of contact with skin, further enhancing the safety.Non invasive, non ablative office treatment
Patients today are seeking affordable, non invasive alternatives to ablative and surgical procedures. The Pelleve System fills that void.Minimal side effects
A Pelleve treatment is virtually pain free and no anesthetic is used for the treatment. The patient may experience some transient erythema or edema, which is typically gone in a few hours.PelleFirm is a non-invasive cellulite treatment that uses radiofrequency energy and massage to deeply heat tissues and temporarily reduce the appearance of cellulite.ELLMAN PELLEVE S5 (TM) HandpiecesPelleve GlideSafe handpieces feature an innovative sensor designed to stop energy flow when the device senses loss of contact with skin – resulting in a more comfortable treatment for the patient. The GlideSafe Handpieces are available in 4 sizes – 7.5 mm, 10 mm, 15 mm, 20 mm – to allow the physician clinician to customize to the individual patient. The compact ergonomic design enables practitioners to comfortably maneuver around the contours of the face, including areas that are difficult to access such as the periorbital region. Each handpiece delivers multiple hours of treatment (activation) time so doctors have the option of customizing each patient’s treatment by using different size handpieces for different areas of the face. This advanced feature allows users to treat multiple patients and perform many procedures using the same charged handpiece.Surgical Versatility
An innovative multi-modality system, the Pelleve Wrinkle Reduction System offers physicians unmatched versatility in a compact design. Beyond skin tightening, the ELLMAN PELLEVE S5 platform facilitates scores of procedures with the availability of hundreds of monopolar and bipolar electrodes.Skin tightening plus surgical procedures
You can use the Pelleve system to deliver aesthetic treatments plus surgical treatments with the S5 platformAdds value to your practice
An ideal procedure to delegate to physician extenders and bundle with other servicesPractice profitability
Low operating costs yield enhanced profitability relative to treatment feeWide range of surgical electrodesFor use with the Pelleve Generator and all other Ellman generators are hundreds of standard and specialty surgical electrodes facilitate procedures ranging from minimally invasive treatments through full surgical procedures. Unlike conventional ESU generators, the Ellman generators are high-frequency radiofrequency devices that enable precise cutting and control with minimal thermal damage. Minimizing tissue damage improves aesthetic outcomes and reduces recovery time. | ALMA SOPRANO ICE PLATINUM LASER
Half the treatment time.
The classic wavelength in laser hair removal, the 810nm wavelength,offers deep penetration of the hair follicle with high average power, a high repetition rate and a large 2cm spot size for fast treatment. The 810nm has a moderate melanin absorption level making it safe for darker skin types. Its deep penetration capabilities target the Bulge and Bulb of the hair follicle while moderate tissue depth penetration makes it ideal for treating the arms, legs, cheeks and beard.
YAG 1064NM WAVELENGTH:Specialized for darker skin types.
The YAG 1064 wavelength is characterized by lower melanin absorption, making it a focused solution for darker skin types.At the same time, the 1064nm offers the deepest penetration of the hair follicle, allowing it
to target the Bulb and Papilla, as well as treat deeply embedded hair in areas such as the scalp, arm pits and pubic areas. With higher water absorption generating a higher temperature, the incorporation of the
1064nm wavelength increases the thermal profile of the overall laser treatment for most effective hair removal.AccessoriesFacial TIP:Reaching the hard to reach.
The unique Facial TIP allows treatment of hard to reach areas, including the ears, nostrils and glabella
Specifications: Diode, 810 nm, Spot Size 6 mmALMA SOPRANO ICE PLATINUM LASER
Technology
TRIO CLUSTERED DIODE TECHNOLOGY:Soprano ICE Platinum offers the synergistic benefits of
the 3 most effective wavelengths for hair removal, each targeting different structures within the hair follicle. The 3 main anatomical targets include the Bulge, Bulb and Papilla.ALEX 755NM WAVELENGTHFor the widest range of hair types and color.
The Alexandrite wavelength offers more powerful energy absorption by the melanin chromophore,
making it ideal for the widest range of hair types and color- especially light-colored and thin hair. With more superficial penetration, the 755nm wavelength targets the Bulge of the hair follicle and is especially effective for superficially embedded hair in areas such as the eyebrows and upper lip.
SPEED 810NM WAVELENGTH: | 2018 Vivace RF Microneedling Radio Frequency Acne ScarsTHE VIVACE EXPERIENCE
The most exciting new technology for aesthetic treatments is the combination of two methods previously used individually for skin rejuvenation, Microneedling and RF Energy. FDA-cleared for your safety, the newest generation, best-in-class Vivace RF Microneedling device, is designed for an incomparable, comfortable experience. Only Vivace boasts a precision robotic motor that brings discomfort to a virtual zero compared to any other device. The results are immediate and improve over time as well, giving you the best of both worlds. Our carefully developed recovery system ensures no one knows you just had a treatment. If you are looking for optimal results, there is no comparison to The Vivace Experience.What is Vivace Fractional RF Microneedling?
The Vivace RF Laser Radio Frequency is the newest generation of microneedling with radio frequency and is effective for fine lines and wrinkles, skin tightening, acne, acne scars, and skin tone, texture and pore size, both on and off the face. It is the most revolutionary contouring and skin tightening system for face, neck, hands and body available, producing immediate, pain-free results.Safe for all skin types, Vivace can offer similar results as ablative and fractional laser procedures, but with significantly less discomfort, downtime, and risk of complications. This revolutionary new treatment also addresses the limitations of older ‘traditional’ RF treatments and heats deeper tissues to a much higher level, which leads to greater collagen production, elastin remodeling and wound contraction previously unattainable with older technology. This is why the Vivace is a game changer in skin rejuvenation and tightening. CLICK HERE to learn moreSlate combines the best device with the newest breakthroughs in numbing, treatment serums and recovery care to create an optimal experience for you that might just keep you from needing other more invasive procedures down the road. The Vivace Experience provides the most dramatic results with less pain and less downtime. The results are both immediate and improve over time with multiple treatments. With results you can see, you’ll look and feel your best at any age.Slate Medspa is the premier Fractional RF Microneedling provider in NJ. We use the most advanced technology to provide a results-oriented skin rejuvenation program. New to Slate Medspa? Call us today at 201-477-5781 to schedule a free consultation and save 20% off your first treatment.How does Vivace Fractional RF Microneedling work?
The Vivace utilizes radio frequency and microneedling to heat the targeted area underneath the epidermis. The Vivace dramatically improves the treatment outcomes compared to other radio frequency microneedling systems.By using insulated needles, Vivace bypasses the epidermis and delivers powerful RF thermal energy to create tens of thousands of fractional coagulation zones in the dermis, facilitating a natural wound healing process. This promotes production of new collagen, remodeling of elastin and wound contraction, enhancing skin laxity. Because the thermal energy is delivered beneath the top layer of skin,Benefits of VIVACE:2018 Vivace RF Microneedling Radio Frequency Acne Scars
Minimizes/Eliminates Fine Lines and Wrinkles
Minimizes/Eliminates Acne Scars & Stretch Marks
Skin Tightening & Texture – Stimulates collagen and elastin production
Treat Sun Damage/Age Spots/Hyperpigmentation
8 Reasons why Slate LOVES Vivace™ RF Microneedling
You’ll see results quickly
Vivace works faster than any other microneedling or laser option. First, the RF Energy creates micro injuries deep in the skin in the form of a matrix. Healthy cells around the newly created matrix promote rapid healing, accelerating collagen production and skin tightening. Secondly, the invisible microchannels in the skin created by the superfine gold-tipped needles remain open for four to six hours allowing maximum absorption the key nutrients and serums applied during the treatment. This would include growth factors, HAs and other cosmeceuticals delivered to the skin in a way that no other treatment can, helping to rapidly rebuild new collagen and elastin.The average patient gets optimal results in just three treatments
Most patients experience noticeably softer, smoother and radiant skin, with improvements in tone, texture and laxity after just one treatment. We can typically achieve optimal results after only three sessions!The treatment is virtually painless
The Vivace Microneedle RF was designed for an incomparable, comfortable patient experience. The unique robotic motor is so precise, it brings the discomfort level to a virtual zero as compared to any other device. The Vivace’s ultra thin needles make it virtually pain-free. A numbing cream is applied before treatment for you to stay comfortable. Our patients here at Slate Medspa consistently report a pain level of “1” on a scale of 1 to 10.There’s no downtime
Vivace’s ultra-thin needles and robotic-assisted mechanism result in an exceptionally precise, even treatment with little-to-no bleeding. In addition, built-in LED Light therapy minimizes post-treatment redness. While we ask patients to wait until the next day before applying makeup, most feel comfortable going out without any makeup.It’s safe for almost any skin type
Patients with darker skin tones can have a more challenging time finding suitable skin resurfacing treatments, as lasers and peels that remove skin layers can risk permanent pigmentation changes. Vivace has 31 Adjustable depths, providing flexibility in treating entire depth or just down deep, bypassing damage to the top layer of skin. This means we can treat a broader array of skin types and tones with absolute precision. In addition, a variable pulse duration means the length of time the needle is engaged with tissue can be precisely controlled based on your skin profile. |
Reviews
There are no reviews yet.