| Description | The HydraFacial resurfacing procedure thoroughly cares for your skin, providing cleansing, exfoliation, extractions, and hydration, including Vortex-Fusion of antioxidants, peptides, and hyaluronic acid. The HydraFacial is a non-invasive, non-surgical procedure that delivers instant results with no discomfort or downtime. The procedure is immediately effective | For women’s health.
Perform minimally invasive, non-hormonal, energy-based gynecological health treatments – in your office, in as little as 10 minutes.Minimize physician fatigue with articulated arm and featherweight handpieces
Gynecology-specific selection of handpieces and lenses
Intuitive touch-screen interface stores and recalls user preferences
Precision internal scanner digitally synchronized with laser pulse generator
Compact, quiet, easily mobile, and portable | Includes:
1 Fractional Scanner Handpiece for Ablative Skin Resurfacing
1 Incisional Handpiece with up to or less than .2mm Spot Size
Handpiece Case
Distance Gauges
Footswitch
Patient Eyewear
Operator Eyewear
Operator Manual
Warning Sign | Deka Synchro Replay Laser Nd-Yag Standard Handpieces – More than 10 selectable handpieces
– Different spotsizes available (2.5 – 24 mm)– Automatic spot recognition system– Ergonomic connector for air-cooling devices | - Muscoskeletal Disorders
- Degenerative arthritis
- Rheumatoid arthritis
- Cervical pain
- Sport injuries
- Frozen shoulder
- Muscle relaxation
- Pain management
| in combination of Spectra Mode and a carbon-based lotion, this soft laser peel feature is specifically designed to emit a quasi-long pulse of 300 microseconds to create photothermal energy to heat the skin’s thin layer of collagen and fibroblast, resulting in a younger and healthier looking. Together with consistent shot-to-shot stability, the VRM is a true workhorse for cosmetic treatments such as photo rejuvenation, non-ablative resurfacing, fine wrinkles, acne scars, and pore size reduction. |
| Content | Edge Systems HydraFacial MD TowerTreatmentThe HydraFacial treatment merges soothing and invigorating spa therapies with advanced medical technology to achieve instant, lasting results. This innovative treatment provides results after just one visit!Skin Health EducationYour skin is the largest organ of your body.Everyday, your skin is exposed to free radicals – unstable molecules like pollution, sun, and stress which damage the vital skin cells like collagen and elastin that keep you looking fresh and young.One of the most damaging free radicals is the sun’s rays. UVA rays have the same strength, every day, all year long.Antioxidants counteract free radical damage by trapping and containing them, preventing further damage to skin cells.The HydraFacial utilizes some of the most powerful antioxidants to revitalize and protect your skin.Skin Health for Life is not just improving your appearance, but actually restoring youthful, healthy skin. Skin health is a lifestyle, requiring monthly maintenance and the right treatment for every skin type. That treatment is the HydraFacial.Works for all skin types- Shows immediate results
- No downtime or discomfort
- Target specific skin concerns
- Provides an alternative to invasive procedures
The process Edge Systems HydraFacial MD TowerStep 1. Cleansing and exfoliation: dead skin cells are removed to revieal healthly new skin.Step 2. Acid peel: this gentle peel helps loosen dirt and debris from pores without irritation.Step 3. Extractions: Painless, automated extractions use vortex suction to clean out pores.Step 4. Hydration: Antioxidants and Hyaluronic Acid are Vortex-Fused™ to nourish and protect.The HydraFacial resurfacing procedure thoroughly cares for your skin, providing cleansing, exfoliation, extractions, and hydration, including Vortex-Fusion of antioxidants, peptides, and hyaluronic acid. The HydraFacial is a non-invasive, non-surgical procedure that delivers instant results with no discomfort or downtime. The procedure is immediately effective | Syneron Candela CO2RE Intima Laser
Laser Type:CO2
Wavelength:10,600nm
Laser Emission Mode:Pulsed
Output Power:60 watts (maximum peak)
Laser Beam Energy:Variable from 1 – 90 mJ
Pulse Repetition Rate:Up to 16.7 kHz
Pulse Duration:20 – 3000 usec
Power Stability:± 1.5 watts (±5%)
Mode Quality:(M²) < 1.2
Beam Size:Ø 1.8 ± 0.5 mm
Beam Divergence:7.5 ± 0.5 mrad (full angle)
Polarization:> 100:1 linear (orthogonal to mounting pads)
Maximum Scan Area:10 mm diameter
Aiming Laser:5 mW, 650 nm (red) diode laser
Articulated Arm:Lightweight, aluminum fiber, 7-joint, pneumatically balanced
Treatment radius at full arm extension:85 cm (33.5″)
Horizontal rotation:360°
Lens Assemblies:150 um spot size, 120 um spot size:(optional)
Handpiece:Multi-use Aesthetic or surgical hand piece
User Interface:10.4″ high-resolution
Laser Emission Control:Footswitch
Laser Emission Indicators:Solid amber LED in Standby and Ready modes
Flashing:red LED during laser emission
Electrical Requirements:100 – 240 VAC self-sensing, 50/60 Hz, 7.1 A, single phase
Dimensions:40 cm x 44 cm x 177 cm, (15.75″ x 17.3″ x 70″)
Weight:26 kg (58 lbs)
Operating Modes
Mode:[ Energy Settings ] [ Fractional Coverage ] [ Estimated Ablation Depth ]
CO2RE Light:[18 – 74.5 mJ] [30 – 50%] [20 – 40 um]
CO2RE Mid:[45 – 257 mJ] [20 – 40%] [100 – 200 um]
CO2RE Deep:[30 – 70 mJ] [1 – 5%] [500 – 750 um]
CO2RE Fusion:[45 – 128 mJ, 30 – 70 mJ] [20 – 40%] [100 – 200 μm & 500 – 750 um]
Classic Resurfacing:[1 – 10 mJ] [Full] [100 – 200 um]
Dermal Excision:[5 – 40 mJ] [N/A] [0.2 mm x selected line 0.2 mm freehand]First fully integrated CO2 laser, worldwide.
Designed to adapt to your patients needs, with 100+ indications.What CO2RE Is For100+ indications cleared in 10 medical specialties, including dermatology, plastic surgery, and gynecology.Imagine having one system designed for numerous procedures that require excision, incision, ablation, coagulation, and resurfacing of soft tissue. Its here. With the CO2RE system, you can precisely target and efficiently treat the skin with control.Treat multiple skin layers in one pass
Perform full and fractional resurfacing
Enhance coagulation
Encourage neocollagenisIndustry-first internal scanner optimized for numerous individualized treatment applicationsKey Benefits of the CO2RE System
Give your patients positive experiences and outcomes.
CO2RE treatments are fast and require limited downtime.The system delivers proven, predictable, visible results across indications1-4, including:Enhancing skin tone and texture through skin resurfacingReducing the effects of the sun and aging on the skinSmoothing out fine lines, wrinkles, and surgical and acne scarsGain unparalleled treatment flexibility that can help your practice grow.
Designed from the inside out to be a comprehensive work station:
CO2RE Aesthetics for skin resurfacing, from superficial to deep skin treatments, including several options and combinations tailored for your patients needs.
CO2RE Surgical for a true, continuous wave with efficient skin coagulation after the surgical cut.
CO2RE® Intima for gynecology applications, enabling you to broaden your portfolio offering.CO2RE Product FeaturesLightLight Peel
20-40 µm
Level with Stratum ComeumMidEpidermal and dermal resurfacing
Coagulation
100-200 µm
Improve skin tone and texture
Complexion refresherDeepDeep fractional resurfacing
Deeper level coagulation
500-700 µm
Improve scars, fine lines and wrinklesFusion Syneron Candela CO2RE Intima LaserCombination of superficial and deep fractional resurfacing
Superficial texture variations
Fine lines and wrinklesWhat CO2RE Intima is For
The CO2RE® Intima system is uniquely engineered to transform treatment of many dermatological conditions, including gynecological needs.
The CO2RE Intimas comprehensive range of treatment options1 include:Using well-established CO2 technology, you can now perform minimally invasive, non-hormonal, energy-based treatments of the introitus, vaginal canal, and external genitalia in your office, in as little as 10 minutes for each treatment.Ablation and resurfacing of soft tissue
Scar tissue (e.g. C-section scar)
Conization of the cervix such as vulvar and vaginal intraepithelial neoplasia (VIN, VAIN)
Leukoplakia (vulvar dystrophies)
Condyloma acuminateThe systems customized handpieces are designed to treat the introitus, vaginal canal, and external genitalia.
Conveniently treat with pre-set or individualized treatment options
Accurately target and treat tissue with ergonomic, pen-like precision2
With 360o rotation capability for ease of use on tissue along the vaginal canal, and sterile for every patient, the single-use handpieces are guaranteed ready to use.Significant benefits for your practice and patients.
Efficient procedural time as little as 10 minutes for each treatment
Minimally invasive, non-hormonal, energy-based treatment
Portable system allows you to easily perform office-based procedures, and is easy to move from room to room
Simple in-office setup for gynecological applications
Single-use handpiece optimizes workflow, enhancing patient safety
Financial savings single-use handpieces reduce staff time, administrative costs, and inefficienciesDesigned with your practice in mind.
The CO2RE Intima system offers numerous user-friendly, productivity-enhancing features.Minimize physician fatigue with articulated arm and featherweight handpieces
Gynecology-specific selection of handpieces and lenses
Intuitive touch-screen interface stores and recalls user preferences
Precision internal scanner digitally synchronized with laser pulse generator
Compact, quiet, easily mobile, and portableWell-established CO2 technology treats skin or soft tissue.
CO2 technology has been used in gynecology for benign and pre-malignant vulvar and cervical dysplasia since 1973.The CO2RE system offers customizable treatment capability with handpiece and lens combinations to provide physician control. Compared to traditional surgical methods, it provides greater precision, cleaner incision, and less scarring. | EMVERA CLARO2 CO2 LASER
Claro2 Medical Laser System
The Claro2 laser technology offers the most innovative approach to laser treatments today. It provides an acceptable and comfortable procedure under little or no anesthesia with minimum pain from evaporation of the skin layers, resulting in minimal social or work downtime. The laser delivers a series of microscopic, closely-spaced laser spots to the skin while simultaneously preserving the normal, healthy skin. The undamaged skin becomes a reservoir of tissue for fast heating and regeneration of the treated area by producing and providing new dermal collagen and eliminating epidermal pigmentation and irregularities to the skin tone. The Claro2 laser system is specially designed to improve skin texture and tone, and fight wrinkles, scars and pigmentations. Since the treatment procedures are customized to patients skin, operators are able to adjust laser settings to tailor treatments and achieve superior results.Claro2 Laser Features Provide:
Unparalleled char-free ablation, vaporization, excision, or incision of soft tissues
Reduced thermal damage to surrounding tissues
Rapid healing and minimal downtime
Stimulation of deeper collagen with high pulse energy
Large TFT LCD touch screen provides easy operation with the latest high speed microprocessor technology
Adjustable scanning patterns and sizes
Adjustable intensity of pilot beam
Adjustable pulse duration
Last treatment setting memorization
Automatic alarm system for operation and errors
No consumable costsIncludes:
1 Fractional Scanner Handpiece for Ablative Skin Resurfacing
1 Incisional Handpiece with up to or less than .2mm Spot Size
Handpiece Case
Distance Gauges
Footswitch
Patient Eyewear
Operator Eyewear
Operator Manual
Warning SignLaser Type:Sealed of Co2 Laser
Wavelength:10.6 um
Mode Structure:TEM00
Max Power:0-30W (adjustable)
Spot Size:Equal to or less than .2mm
Aiming Beam:630nm Red Laser (Adjustable Brightness)
Delivery System:Articulated Arm
Operation Modes:Continuous Wave, Single Pulse, Repetition Pulse, Super Pulse, Scanner
Pulse Width:Single Pulse (0.01-1s); Repetition Pulse (0.001-1s); Scanner (0.0001-0.01s)
Scan Size: Adjustable
Scan Pattern:Oval, Triangle, Rectangle, Line
Scan Array Density:Adjustable
Cooling System:Self-Contained, Closed Cycle
Power Supply:100-120V AC, 50/60Hz or 200-240V AC, 50/60Hz
Environment Temperature:10-40 Degrees Celsius
Relative Humidity:Below 80%
Dimensions:561mm x 500mm x 1443mm
Weight:42kgApplications Include:EMVERA CLARO2 CO2 LASERDermatology, Plastic Surgery and General Surgery procedures including but not limited to:
Laser skin resurfacing
Treatment of furrows and wrinkles
Removal of skin tags, actinic keratosis, acne scars, keloids, tattoos, telangiectasia, squamous and basel cell carcinoma, warts and uneven pigmentation
Treatment of cysts, abscesses, hemorrhoids and other soft tissue applications
Blepharoplasty
Site preparation for hair transplantsOtorhinolaryngology (ENT) procedures including but not limited to:
Treatment of leukoplakia of larynx, nasal obstruction, rhinophyma, verrucrea vulgares, choanal atresia, rhinophyma, LAUP and papillomatosis polypsGynecology:
Treatment of condyloma acuminate, cervical
intraepithelial neoplasia, leukoplakia and vulvar/
vaginal intraepithelial neoplasia, cervical dysplasia
Podiatry procedures including but not limited to:
Ablation, vaporization and excision of soft
tissue lesions such as ingrown nail, fungal nail,
porokcratoma, matrixectomy and verrucae vulgares | Deka Synchro Replay Laser Nd-Yag Inside Moveo Innovation Moveo HR: Focus on Hair Removal
The multiple passes of Moveo HR over small defined areas cause gradual heating and destruction of unwanted hairs.
Moveo PL: Focus on Pigmented Lesions
The new MOVEO PL is indicated for skin age and sun spots progressively heating the pigmentedMoveo SR: Focus on Skin Rejuvenation
The multipass controlled action of MOVEO SR causes a progressive increase in heat at the dermal level, which stimulates a neocollagenic process.Moveo VL: Focus on Vascular Lesions
The specific action of Moveo VL acts directly and effectively on vascular redness.The versatile FT lamp can be added to the system at any time, enhancing the user’s ability to treat superficial Vascular and Pigmented Lesions.The FT pulsed light has ten different filters divided in five spectra of emission (500-520-550-600-650nm) and two spot areas. This flexibility is useful to adapt the emitted light to the patient skin type, application and treatment area.Deka Synchro Replay Laser Nd-Yag Standard Handpieces – More than 10 selectable handpieces
– Different spotsizes available (2.5 – 24 mm)– Automatic spot recognition system– Ergonomic connector for air-cooling devicesDeka Synchro Replay Laser Nd-Yag
Wavelength: 1064 nm
Pulse Energy: 120 J (max)
Pulse Lenght: 0.2 ms to 300 ms
Frequency Single Pulse: 10Hz (max)
Spot Diameter: 20mm, 15mm, 10mm, 7mm, 5mm, 2.5mm
Emission Spectrum: 500-950 nm and 650-950 nmTo Include:
1 x Foot Switch
1 x Key
1 x Module UPL Handpiece
6 x Deka Laser Handpieces
1 x ManualInside Moveo InnovationMoveo HR: Focus on Hair Removal
The multiple passes of Moveo HR over small defined areas cause gradual heating and destruction of unwanted hairs.
Moveo PL: Focus on Pigmented Lesions
The new MOVEO PL is indicated for skin age and sun spots progressively heating the pigmented lesions.Moveo SR: Focus on Skin Rejuvenation
The multipass controlled action of MOVEO SR causes a progressive increase in heat at the dermal level, which stimulates a neocollagenic process.Moveo VL: Focus on Vascular Lesions
The specific action of Moveo VL acts directly and effectively on vascular redness. | 2020 CRYOMED HYPERMAX TALENTPRO
Electro-Magnetic Stimulation Technology
hyperMAX utilises Electro-Magnetic Stimulation technology to induce supramaximal contractions for
the growth and development of muscles. The magnetic field changes quickly inducing electrical currents in the tissue where neuronal membranes are depolarised and motor units in the target muscles are controlled to cause concentric contractions.How does it work?
Electro-Magnetic Stimulation helps to rebuild and repair muscle tissue, resulting in stronger and firmer muscles.
The strong Electro-Magnetic stimulation, of up to 3 Tesla, works deep to the hypodermis, influencing
muscle fibres and cell membranes to optimise cellular metabolism, supplying more oxygen for better blood circulation.Dualsculpt with Applicators
hyperMAX utilises Electro-Magnetic Stimulation technology to induce supramaximal contractions for the growth and development of muscles. The magnetic field changes quickly inducing electrical currents in the tissue where neuronal membranes are depolarised
and motor units in the target muscles are controlled to cause concentric contractions.2020 Cryomed HyperMAX TalentproIndications:- Muscoskeletal Disorders
- Degenerative arthritis
- Rheumatoid arthritis
- Cervical pain
- Sport injuries
- Frozen shoulder
- Muscle relaxation
- Pain management
Spinal Disorders- Acute/chronic lumbago
- Sciatica
- Spinal bifida
- Spondylitis chronic back pain
- Spinal disc disease
- Intramuscular stimulation
- Trigger Point Injection
Electro-Magnetic Stimulation TechnologyhyperMAX utilises Electro-Magnetic Stimulation technology to induce supramaximal contractions for
the growth and development of muscles. The magnetic field changes quickly inducing electrical currents in the tissue where neuronal membranes are depolarised and motor units in the target muscles are controlled to cause concentric contractions.How does it work?Electro-Magnetic Stimulation helps to rebuild and repair muscle tissue, resulting in stronger and firmer muscles.
The strong Electro-Magnetic stimulation, of up to 3 Tesla, works deep to the hypodermis, influencing
muscle fibres and cell membranes to optimise cellular metabolism, supplying more oxygen for better blood circulation. | LUTRONIC SPECTRA VRM III TATTOO LASER
Laser Source:Nd:YAGWavelengths:532 nm, 1064 nm, 585 nm and 650 nm (dye handpieces)
Operating Mode:5-7 nanoseconds
Pulse Duration:Spectra mode = 300 microseconds
Maximum Energy:Q-switched mode = 1,000 mJ, Spectra mode = 1,500 mJ
Beam Profile:Top Hat (Uniform) Mode
Optical Delivery:Articulated arm
Aiming Beam:Diode 655 nm (Red) 1 mW, adjustable brightness
The Lutronic Spectra VRM is an award-winning laser system designed for use in a wide range of dermatological and aesthetic procedures. This powerful Q-switched Nd:YAG system is clinically effective for a variety of benign pigmented lesions, tattoos and more. Offering two distinct wavelengths at 1064nm and 532nm, the Spectra VRM (with optional solid dye handpieces) reliably removes even colored amateur, professional and traumatic tattoos with precision and ease. With the optional solid dye hand pieces, the VRM series can double its capacity in treating an assortment of tattoo inks.
A special feature of the VRM Series is the addition of the Lutronic “Spectra Mode” that extends the range of procedures that can be performed to include laser peeling, skin rejuvenation, wrinkle removal and melasma treatments.In combination of Spectra Mode and a carbon-based lotion, this soft laser peel feature is specifically designed to emit a quasi-long pulse of 300 microseconds to create photothermal energy to heat the skin’s thin layer of collagen and fibroblast, resulting in a younger and healthier looking. Together with consistent shot-to-shot stability, the VRM is a true workhorse for cosmetic treatments such as photo rejuvenation, non-ablative resurfacing, fine wrinkles, acne scars, and pore size reduction.Lutronic Spectra VRM III Tattoo Laser Includes:– System– Mast– Power Cable– Foot Switch– Key– Spectra Lotion– 2 Hand Piece Wooden Cases– Hand Pieces:— SD650nm Dye Handpiece— SD585nm Dye Handpiece (Gold)— Nd:YAG 1-7mm (Black, w/Cable)— Nd:YAG 7mm Handpiece (Red, w/Cable)– Smoke Handpiece– Operator’s Manual– Accessories (as shown) |
Reviews
There are no reviews yet.