| Description | The M6 therapy laser is a robotized multi-target device designed to treat patients suffering pathologies affecting a wide area, and to perform automatic applications. The distinctive feature of the M6 is the innovative multi-target functioning. Thanks to the features of the exclusive MLS multi-diodic optical group, a wide area is treated instantaneously helping to produce an immediate response of the treated tissues. The results are better and faster than with the scanning modality of traditional laser therapy products. | Highest available power allows for fast treatments, customizable for multiple areas
Gentle, effective global improvement for all skin types, all year-round
Comfortable treatments with very little downtime
Minimal cost of ownership, easy to delegate and no shot limit per procedure | Fast and Easy Applicator Exchange
With a simple press-and-release mechanism, the Clatuu Alpha allows maximum convenience and makes switching cooling cups as simple as possible. Detaching cables or turning the system off is not required even during treatments. | 2015 Active Optical Extra 818 IPL Hair Removal and Skin Rejuvenation; Excellent Cosmetic and Operating Condition, Very Lightly Used for Demonstrations Only, Single Owner; Included Handpieces and Pulse Counts: Hair Removal Handpiece = 6,617 Pulses, Facial Handpiece = 2,190, Life for Each Handpieces is 250,000 Pulses. | 2017 InMode Aesthetics InMode Contoura Cellulite Reduction System – with 3 Handpieces; Manufactured on 03/22/2017; Excellent Operating & Cosmetic Condition, Single Owner, Used for approximately 60+ Hours; SW Version: 2.31CTR; Reason for Selling: Downsizing; Handpieces Included: BodyFX, MiniFX, & Forma Plus; Also Includes: Footswitch. | 2017 Lumenis M22 with ResurFX & IPL in Like-New Condition; Manufactured 10/22/2017; Based Unit Serial Number 11860, IPL Handpiece Serial Number: 4751; Nd Yag Serial Number: Perfect Cosmetic and Operating Condition, Single Owner; Handpieces Included & Total Pulse Counts: IPL Handpiece Total Pulse Count = 908; ResurFX Handpiece Pulse Count = 16 Pulses; Includes Expert Filters: 515nm, 560nm, 590nm, 615nm, 640nm, 695nm, and 755nm; Also Includes: Footswitch, Interlock, Operator Manual. |
| Content | Cutting Edge MLS M6 Laser Therapy Unit
The M6 therapy laser is a robotized multi-target device designed to treat patients suffering pathologies affecting a wide area, and to perform automatic applications. The distinctive feature of the M6 is the innovative multi-target functioning. Thanks to the features of the exclusive MLS multi-diodic optical group, a wide area is treated instantaneously helping to produce an immediate response of the treated tissues. The results are better and faster than with the scanning modality of traditional laser therapy products.Technical Features
Robotized optical group with 3 MLS sources – power up to 3.3 W
5 cm diameter target area highlighted by high-efficiency red light LEDs
Back-lit graphic touch-screen display
Simultaneous management of two independent channels
MLS pulse modulation frequency from 1 to 2000 Hz with 1 Hz steps
Power level 50% and 100%
Variable or fixed duty cycle
Treatment duration from 1″ to 99’59” with 1″ steps
Automatic calculation of the emitted energy according to the set parameters
Alarms and Safety Features
Laser emission warning light
Interlock (can be temporarily disabled)
Acoustic signal for the beginning and the end of the therapy, and for each treatment second (can be disabled)
Password to operate the device
Language option (Italian, English, German, Spanish)
Dimensions and Weight
27 x 17 x 62 inches; 95 lbsPower Supply
115/230V~ 50/60Hz 150VACUTTING EDGE MLS M6 Laser Therapy UnitTalk to your specialist.
Since 1983 we have been working to be the reference point in Laser Therapy and Magnetotherapy in many areas: from physiotherapy to rehabilitation, from the management of muscle and joint pain to sports medicine. The result of our work allows us today to be recognized as an international leader in the knowledge and development of advanced technologies in the field of “pain management”: a recognition confirmed in 2003 with the entry of the El.En Group. (Star segment of the Italian Stock Exchange – ELN.MI), one of the most important realities in the laser world, both for industrial and medical applications.We have always thought that research is not only confirmation, but also the necessary premise for our work. Born from the synergy between ASAlaser and the Department of Experimental and Clinical Biomedical Sciences of the University of Florence , the ASAcampus laboratory allows us to test the validity of our work and improve results over time. The result of the research is disseminated through conferences, supported thanks to important partnerships and disseminated through numerous scientific publications.Our medical devices for MLS ® Laser Therapy , Hilterapia ® and Magnetotherapy are built according to contents that we consider indispensable: advanced technologies and software, efficacy and safety, ergonomics and design. They allow for ever more targeted and personalized treatment methods. The effectiveness of our therapies is continuously tested thanks to the research carried out in ASAcampus whose results are constantly transferred to clinical applications. | 2015 Lutronic LaseMD Pro Fractional Skin Wrinkles
Lutronic LaseMD Ultra Laser is an impressive upgrade to their already successful LaseMD,” shared Steven Weiner, MD, from Lutronic.“Not only is it more powerful (20 watts vs 12 watts) but it also has a significantly lower consumable cost than competitive systems. The LaseMD ULTRA offers a new larger spot size and incorporates improved ‘top hat’ beam profile. The system also offers an incredibly advanced graphical user interface.“The integration of all the new features with real-time information helps reduce treatment time and achieve satisfying patient results in fewer treatments. Since no anesthesia is required, I can treat a full face in about 6-8 minutes or treat the face, neck and chest in 20 minutes.”Lutronic LaseMD Ultra Laser is yet another example of Lutronic’s commitment to Intelligent Design for Intelligent Care, according to the company in a media release. Features include:Highest available power allows for fast treatments, customizable for multiple areas
Gentle, effective global improvement for all skin types, all year-round
Comfortable treatments with very little downtime
Minimal cost of ownership, easy to delegate and no shot limit per procedure“LaseMD ULTRA is my favorite new addition to my practice. It allows me to treat multiple areas quickly, effectively and for very low cost,” adds Joel Cohen, MD, in the release. “My patients love the comfortable treatments and impressive results with minimal downtime.”The LaseMD ULTRA a high-power platform which provides a full range of applications in all skin types, including:Age spots (lentigos),
Sunspots (solar lentigos),
Freckles (ephilides),
Actinic Keratoses, and
Treatment of other benign pigmented lesions.Fractional Skin ResurfacingWrinkles - Laxity - Scar Reduction - Pigmentation - Melasma - Anti-Aging - Actinic Keratosis Excellent, Pre-Owned Condition
Serviced and Fully TestedMfr: Lutronic
Model: LaseMD PRO
S/N: LS115D047PS
Mfr Date: 06-19-2015LaseMDAdvanced skin resurfacing laser featuring the Thulium 1927nm wavelength, which focuses on coagulation rather than ablation.Suitable for all skin types.Cosmeceutical Delivery SystemLaseMD creates micro-channels in the skin to specific depths to delivery topical serums to the correct layer of the skin and increase absorption. It also features a built in centrifuge/incubator for LaseMD serum Ampoules.Optimized Magnetic Sensor Tracking Scanner Includes: 2015 Lutronic LaseMD Pro Fractional Skin Wrinkles
- LaseMD Workstation with Scanning Handpiece
- LaseMD Rolling Cart
- 2 Handpiece Caps
- FootSwitch Pedal
- System Key
- Power CableSpecifications:
Laser Type: Thulium
Wavelength: 1927nm | 2020 CRYOMED CLATUU ALPHA
Clatuu Alpha is a leading dual-sculpting system with precise 360° surround cooling that achieves maximum coverage of the treatment area and provides fast and effective dual handpiece fat-freezing treatments. The Clatuu system maintains a constant target temperature that prevents unwanted side effects with a proven track record of dependability and clinical efficacy.Fast and Easy Applicator Exchange
With a simple press-and-release mechanism, the Clatuu Alpha allows maximum convenience and makes switching cooling cups as simple as possible. Detaching cables or turning the system off is not required even during treatments.Various Applicators for any Spot 2020 CRYOMED CLATUU ALPHA
The CLATUU Alpha’s wide range of cooling cups are designed to perfection within our R&D labs and are suitable to conform to a large variety of body shapes and patients. Each individual cup helps to achieve a variety of customized treatment plans to effectively reduce fat cells for the ultimate dual sculpting body contouring experience.Applicators Optimized for Any Treatment
After laborious testing and research, each individual cooling cup has been ergonomically designed to adhere to each curve of the body.
The Clatuu Alpha has been optimized to achieve desired outcomes from head to toe.Advanced Technology for Maximum Results
Having accumulated countless hours in research and development, the Clatuu Alpha features a revolutionary approach to absolute, non-invasive body contouring through a more powerful cooling technology.
Upgraded 360° Surround Cooling
360° Surround Cooling Technology unlike the conventional two-sided cooling methods, increases efficiency by up to 18.1%. Allowing delivery of cooling to the entire cup and in result removes fat cells more effectively.Sculpt with two applicators in one device
The Clatuu Alpha has the ability to have two high-speed handpiece applicators treating at the same time allowing duo sculpting to take place. Faster to Target Point
The cooling system of the Clatuu Alpha is engineered to reach its target temperature faster than previous models, reducing the inconveniences of waiting and maximizing time efficiency for both patients and physiciansAdjustable Levels
Not only is the Clatuu Alpha capable of 20% stronger suction, it also provides medical practitioners with the ability to adjust both cooling and suction levels to confidently provide customized treatments for patients.Science Behind ALPHA
Each cooling applicator is engineered to target the patient’s subcutaneous fat layer without damaging surrounding tissues or nerve regions, It is through this advanced cooling technology that we are able to welcome you to the Innovative Age of ALPHA. | Active Optical Extra 818 IPL Hair Removal 2015Handpieces:Hair Removal Handpiece and Facial Handpiece
Chilled Tip:Up to 4c
Pulse Interval:0.5~2 Seconds
Output Power:11-31 joule/cm2, upto 4,000W
Cooling System:Revolutionary dual cooling
Control:Intuitive touch screen control
Lamp’s Life Span:250,000 Flashes (Universal), 200,000 Flashes (Facial)
Treatment Area:7.5 cm2 (15*50mm) Universal, 4.5 cm2 (15*30mm) Facial
Wavelength:420-1100 nm
Weight:42Kg (including Stand, if device is not a table top)
Dimensions:44cm x 45cm x 100cm Extra-818Skin Rejuvenation
Pigmentation Treatment
Acne Treatment
Hair Removal
Vascular (Facial) TreatmentThe Extra – 818 is the outcome of more than a decade of treatments and thousands of devices operated worldwide. It contains It contains unique features:
* Contemporary touch screen control
* Built-in Patch Test procedure for examining the optimal energy level
* A stunning number of 450,000 flashes in both lamps.The Extra – 818, based on Active’s GEM-PL technology, sets sets a specific Pulse Pattern according to the selected treatment type, skin color, skin photosensitivity and treatment depth.
The treatment protocols and different pulse patterns take into account the tissue’s TRT (Thermal Relaxation Time) and the combined knowledge accumulated from thousands of treatments done during the years and clinical investigations done to confirm the findings.The combination of tested treatment protocols with high end engineering makes the Extra – 818 the perfect device for leading clinics.Revolutionary Cooling System
The Extra – 818 has a dual cooling system, controlled and monitored in order to ensure long lifetime to the lamp and a comfortable treatment to the patient.Competitive cooling systems “freeze” the skin so that during the treatment the skin temperature will rise to a bearable level. However, this “freezing” temperature might limit the results because the follicles will not reach the coagulation temperature. To ensure optimal results Active installed a special Processor that prevents overcooling the skin and maintains a uniform low temperature of the “glass” throughout the treatment. This revolutionary system enables the Extra – 818 to provide best results with optimal patient comfort.Research Program Active Optical Extra 818 IPL Hair Removal 2015
For clinical investigations, the self setting program allows researchers to set the treatment’s parameters according to their needs. Allowing advanced research with the device.
The energy levels in the self setting program can reach 31Jcm2 with high intensity of 4,000W. | 2017 InMode Aesthetics Contoura Cellulite Reduction System BodyFX
Vacuum:300 – 500 mBar
RF Output Frequency:Up to 50 W
Output Frequency:1 MHz
Temperature Cut-Off:Real time temperature monitoring and cut off operator selectable to 43°C
MINIFX – Only Available on Newest Generation Contoura’s
Chamber Size:1 inch x 1 inch
RF Output Frequency:Up to 50 W
Output Frequency:1 MHz
Negative Pressure:Up to 500 mBar
Temperature Cut-Off:Real time temperature monitoring and cut-off. Operator selectable up to 43°C
PLUS
RF Output Frequency: Up to 65 W
Output Frequency: 1 MHz
Temperature Cut-Off: Real time temperature measurements set by operator up to 43°C FULL BODY CONTOURING EXPERIENCE
Contoura is the reshaping solution to maximize patient results. WORKSTATIONS
Body contouring is one of the most in-demand aesthetic treatments. In many cases, patients are looking for improvements in body shape without surgical intervention 1. Contoura is a non-invasive body contouring solution that provides treatments that can be done during a lunchtime break.Contoura addresses: Body Reshaping, Cellulite Reduction and Skin Contraction. The Contoura is the ONLY non-invasive body contouring device proven in peer reviewed and published human studies to both permanently kill adipose tissue and contract the skin.PRACTICE BENEFITS 2017 InMode Aesthetics Contoura Cellulite Reduction System
Unlike other body contouring devices (which may carry high per procedure cost), Contoura has zero consumable costs or pulse counters. 4
Contoura is a business solution that allows you to grow your patient base without having to worry about ongoing fees.The use of radio frequency allows owners to provide both skin contraction and fat treatments, of all body areas, in one device. 5 This provides multiple revenue streams to a practices bottom line. This provides multiple revenue streams to a practices bottom line.1. According to the ASAPS 2017 statistical report, non-surgical fat reduction was listed as the third most performed procedure in 2017, after Botox and fillers. Source
2. Treatments take anywhere between 20-60 minutes. A series of 6-8 treatments is recommended.
3. Peer Reviewed Source
4. BodyFX is clinically proven to contract skin and reduce fat. BODYFX
The first and only non-invasive body contouring technology proven in peer reviewed and published human studies to both permanently kill adipose tissue and contract the skin. HOW DOES IT WORK
BodyFX is the first and only non-invasive body contouring and cellulite technology proven in peer reviewed and published human studies to both permanently kill adipose tissue and contract the skin *. BodyFX addresses problematic fatty tissue in larger body areas such as the abdomen, back (flanks), and thighs. BodyFX works by using different clinically proven modalities including radio-frequency energy and negative pressure applied to the skin and underlying fat. BODYFX Benefits
Acquire. Control. Extend. Technology to safely optimize peak energy.
Pre-heating of tissue reduces threshold for selective apoptosis of fat cells.
Sophisticated tissue temperature and impedance monitoring achieves and maintains optimal temperature end points to prevent atrophic damage.
Active temperature monitoring and control with cut-offs for unprecedented safety, virtually eliminating risk of thermal injury.MINIFX – Only Available on Newest Generation Contoura’s
A new, non-invasive solution to reduce the unsightly appearance of cellulite in smaller areas like the arm, neck and knees. HOW DOES IT WORK
MiniFX is a non-invasive contouring and cellulite technology that delivers a combination of clinically proven modalities, similar to the BodyFX, however, addresses problematic fatty tissue in smaller areas like the neck , arms, and knees. MINIFX BENEFITS
Acquire. Control. Extend. Technology to safely optimize peak energy.
Pre-heating of tissue reduces threshold for selective apoptosis of fat cells.
Sophisticated tissue temperature and impedance monitoring achieves and maintains optimal temperature end points to prevent atrophic damage.
Active temperature monitoring and control with cut-offs for unprecedented safety virtually eliminating risk of thermal injury. PLUS
Stimulates the formation of new collagen and improves the skin’s elasticity for long-lasting and remarkable results. HOW DOES IT WORK
Plus is a non-invasive sub-dermal heating applicator that stimulates sub-cutaneous tissue. Radio-frequency energy flows uniformly between the electrodes to provide a comfortable thermal experience, built-in temperature controls allow for the attainment of clinically proven optimal temperatures without concerns of hot spots or under treatment. PLUS Benefits
Acquire: Forma has a temperature sensor built into the hand piece which reads skin surface temperature 1000 times per second, allowing clinicians to acquire skin temperature in real time.
Control: Software algorithm allows unprecedented safety of RF delivery. The cut off temperature” feature reduces RF energy automatically when the hand piece senses that the required skin temperature has been reached.
Extend: Clinical evidence suggests prolonged exposure to temperature above 40°C is advantageous for optimal clinical outcomes. Only InMode’s A.C.E. technology allows you to utilize therapeutic temperatures safely and efficiently. | 2017 Lumenis M22 IPL with ResurFX| Manufacturer Notes |
|---|
| M22 is a modular multi-application platform for the treatment of over 30 skin conditions and hair removal.Available Treatments with M22:– Acne Scar Treatment
– Hair Removal
– Non-Ablative Skin Resurfacing
– Photorejuvenation
– Pigmentation Treatment
– Scar Revision
– Vascular / Leg Vein Treatment
– Dark Tattoo RemovalUsed by physicians around the world, M22 enables you to treat more types of patients and conditions with better outcomes.4 Multiple Technologies In One Modular SystemM22 grows with your practice and can expand to your treatment needs and adapts to future applications as they emerge.Universal IPL
Optimal Pulse Technology (OPT)
Single handpiece with changeable filters and lightguides
For IPL skin treatments using photorejuvenationResurFX
The only True fractional non-ablative, with CoolScan scanner
No disposables
For skin resurfacingMulti-Spot Nd:YAG
The only one with Multiple Sequential Pulsing (MSP)
2 sized lightguides, changeable in seconds
For treatment of leg veins and vascular lesionsQ-Switched Nd:YAG
Homogenous beam profile for enhanced treatment safety and efficacy
For skin toning*, dark tattoos removal, and combination treatments
*Skin toning by treatment of pigmented lesions |
2017 Lumenis M22 IPL with ResurFX and Q-Switched Nd:YAG A modular multi-application system for hair removal and various skin conditions Details:M22 Serial Number: 21171 M22 Date of Manufacture: 2017-07-17 Total IPL Pulses: 19,186 Total ResurFX Pulses: 10,772 Q-Switched Nd:YAG Pulses: 385,505
Includes:IPL Handpiece Complete Standard IPL filters: 515, 560, 590, 615, 640, 695, 755nm, and Calibration Specialty IPL Filters: Acne and Vascular IPL Light Guides: (1)35 x 15 mm2; (1)15 x 8 mm2, (1) 6mm- round ResurFX Handpiece with SapphireCool Tip Q-Switched Nd:YAG Handpiece Foot Switch Power Cord 30 Days Parts and Labor Warranty
|
System specifications
Dimensions:[without ResurFX] 44 x 50.5 x 47 cm (17 x 20 x 18.5 inches)
Dimensions:[with ResurFX] 44 x 50.5 x 61.5 cm (17 X 20 X 24 inches)
Weight:[without ResurFX] 40 kg / 88 lbs
Weight:[with ResurFX] 55 kg / 121 lbs
Electrical requirements:100 240 VAC ±10%, 15A max., 50/60 Hz, single phase, dedicated line M22 is a modular multi-application platform for the treatment of over 30 skin conditions and hair removal. Available Treatments with M22:– Acne Scar Treatment
– Hair Removal
– Non-Ablative Skin Resurfacing
– Photorejuvenation
– Pigmentation Treatment
– Scar Revision
– Vascular / Leg Vein Treatment
– Dark Tattoo RemovalUsed by physicians around the world, M22 enables you to treat more types of patients and conditions with better outcomes.4 Multiple Technologies In One Modular SystemM22 grows with your practice and can expand to your treatment needs and adapts to future applications as they emerge. Universal IPL
Optimal Pulse Technology (OPT)
Single handpiece with changeable filters and lightguides
For IPL skin treatments using photorejuvenation ResurFX
The only True fractional non-ablative, with CoolScan scanner
No disposables
For skin resurfacing Multi-Spot Nd:YAG
The only one with Multiple Sequential Pulsing (MSP)
2 sized lightguides, changeable in seconds
For treatment of leg veins and vascular lesions |
Reviews
There are no reviews yet.