| Description | Includes:
Hand-held 2 MHz 40 cm2
Hand-held 1 MHz 16 cm2Head
Key
Operators Manual | Pollogen Divine Pro Skin RejuvenationTriPollar with DMA is a non-invasive technology which uses radiofrequency energy to generate heat through resistance in both the dermal and subcutaneous layers causing collagen fibres to contract. This creates an immediate skin-tightening effect.TriFractional RF enables effective fractional skin resurfacing, with the energy creating microwounds.Voluderm is a minimally-invasive solution that uses fine ultra-thin electrodes combined with radio-frequency to gently ablate the epidermis and heat the deeper dermal layer. | hair removal laser / skin rejuvenation / vascular lesion treatment / onychomycosis treatment | Fraxis PRO combines CO2 skin resurfacing technology with radiofrequency microneedling to treat a multitude of skin concerns. | 2017 Cutera Excel HR 1064 Nd Yag & 755 Alexandrite Hair Removal System, as well as Pigment & Vein Removal & Laser Genesis Skin Rejuvenation;Manufactured: 11/02/2017; Good Cosmetic and Operating Condition, Complete System Refurbishment Performed March 2022; New Replacement Handpiece Installed 03/2022;1064 Nd Yag Pulse Count = 41,588, 755 Alexandrite Pulse Count = 20,591;Includes: New Handpiece, Footswitch, Key, Operator Manual, Operator Eyewear, Patient Eyewear, Interlock. | ADVANCED TECHNOLOGY2019 Venus Concept Neo Graft 2.0 system is the industry pioneer and market leader with one of the first automated FUE system in the hair restoration market. NeoGraftharvesting, site-making and implantation functions make it easier than ever for physicians to address hair loss and provide the hair restoration procedures that patients want. The inefficiencies of manual extractions and implants have been eliminated, and replaced it with advanced technology that provides patients with the benefits of the FUE procedure while also enabling physicians to perform fast, effective, safe hair transplants that yield superior clinical results. |
| Content | CUTERA TRUSCULPT 3D BODY SCULPTING
Cutera Trusculpt 3D Body Sculpting A New Dimension in Body Sculpting
The rise in popularity of body sculpting can be attributed to two main factors: improved non-surgical treatment results and a population that values investing in themselves.The truSculpt 3D body sculpting device is ideal for patients and practitioners alike. truSculpt 3D is a non-invasive, Monopolar RF system optimized to deliver Targeted, Repeatable and Uniform sculpting of problem areas for a TRU 3D result with no visual downtime. truSculpt 3D takes a multi-dimensional approach to decrease circumference and reduce fat cells, by delivering and holding clinically therapeutic temperatures to the subcutaneous adipose tissue to achieve the clinical efficacy in the shortest possible treatment time with enhanced comfort.Glide Technique
truSculpt 3D glide technique offers consistent results – an average of 24% fat reduction, in a short treatment time over a large treatment zone.1 One 60-minute session provides clinically proven results in the most common treatment areas — the abdomen and flanks.Targeted RF Energy
The truSculpt 3D system uses a low frequency and high conductivity radiofrequency (RF) technology for deep penetration to target the subcutaneous fat layer while maintaining a comfortable surface temperature for patients. Over a 12-week period, the damaged fat cells are slowly broken down and eliminated from the treated subcutaneous adipose tissue2.Repeatable, Proven Outcomes
truSculpt 3D features a proprietary closed-loop temperature feedback mechanism that ensures therapeutic temperatures are met throughout each treatment. This means your patients are comfortable while achieving consistent results.Cutera Trusculpt 3D Body SculptingtruSculpt 3D Handpieces
truSculpt 3D gives you the flexibility to non-invasively address body sculpting concerns. With truSculpt 3D’s two handpiece options (40 cm2 and 16 cm2), you can decrease circumference and eliminate unwanted fat from large and small areas.Hand-held 2 MHz 40 cm2
For use in a gliding motion over fat pockets contained within the small, medium or large treatment templates. Handpiece covers up to a 576 cm2 treatment area on the abdomen and flanks in 60 minutes.Hand-held 1 MHz 16 cm2
For use with a stationary placement over soft tissue in areas that are smaller than the templates. The 16 cm2 handpiece covers petite treatment areas in 5 minutes.Includes:
Hand-held 2 MHz 40 cm2
Hand-held 1 MHz 16 cm2Head
Key
Operators Manual | Pollogen Divine Pro Skin Rejuvenation
Divine Pro works via a synergised treatment of Pollogen’s patent technology VoluDerm, a fractional two-step thermal ablation process using up to 100 radiofrequency-assisted ultra-thin electrodes.This new generation of microneedling works on the process of generating micro-wounds through thermal ablation, where each individual needle delivers radiofrequency in both the epidermis and dermis without the risk of post-inflammatory hyperpigmentation and scars.The multi-dimensional platform incorporates a winning combination of clinically-proven technologies Voluderm microneedling, Tripollar RF, DMA (dynamic muscle activation) and Trifractional RF, and is indicated for skin tightening, skin resurfacing, dermal volumisation, muscle re-education, acne scarring and stretch marks.TriPollar with DMA is a non-invasive technology which uses radiofrequency energy to generate heat through resistance in both the dermal and subcutaneous layers causing collagen fibres to contract. This creates an immediate skin-tightening effect.TriFractional RF enables effective fractional skin resurfacing, with the energy creating microwounds.Voluderm is a minimally-invasive solution that uses fine ultra-thin electrodes combined with radio-frequency to gently ablate the epidermis and heat the deeper dermal layer.These multi-dimensional treatments work together to renew the deep dermis, mid-dermis and epidermis to provide a holistic approach for repairing signs of ageing.Pollogen Divine Pro Skin Rejuvenation Minimal downtime minimal discomfort – how it works:Unique penetration method: Instead of mechanical penetration of the needles, which can produce a painful sensation, our RF microneedling technology creates channels simultaneously with the penetration of the needles which is driven by continuous RF. This results in efficient dermal effect, minimal bleeding and downtime.Ultrathin needles (150 micron): Some of the thinnest needles on the market with the optimal length for efficacy; these needles ensure a full-length smooth insertion into the channels created by the RF, reaching the exact layer of the skin where maximum efficacy is achieved. The thin needles allow for optimal energy density, providing higher efficacy at lower energy levels, thus reducing discomfort during treatment.Quicker treatments with no anaesthetics: Thanks to the combination of RF-first penetration and thin needles, no mechanical force and less repeated passes are required to ensure even coverage. As a result, pain is minimised, therefore anaesthesia is not required to achieve results.High safety profile: The unique RF-first technology ensures standardised treatment protocol without dependency on user expertise. The penetration mode induces minimal damage to the epidermis and therefore reduces the risk of unwanted adverse events.TriFractional RFTriFractional RF energy rejuvenates the outer epidermis layer, by creating micro-wounds which trigger the body’s natural healing response mechanism.VoluDermVoluDerm provides a safe and effective penetration of the epidermis for controlled heating targeting deep dermis. This minimally invasive treatment uses fine micro-needles while applying RF to volumize the deep dermal layer. The micro-needles stimulate the body to naturally produce hyaluronic acid, new collagen and elastin.TriPollar with Dynamic Muscle Activation (DMA)TriPollar RF uses radiofrequency to generate heat in both the dermal and subcutaneous layers leading to an immediate skin tightening effect. Collagen regeneration then provides a long term effect. Dynamic Muscle Activation energy stimulates the facial muscles resulting in lifting and toning, accelerating lymphatic circulation and optimizing detoxification.Pollogen Divine Pro Skin Rejuvenation purchase include :- The Main DIVINE PRO unit
- Voluderm & Trifractional Hand-piece
- TriPollar with DMA Hand-piece
- Power lead and adapter plug
- Operational Manual
Training manual x 2
- 12 month manufacturers warranty
- Trainings days for your staff x 2
- Event Day to market your DIVINE PRO treatments
In addition, you’ll receive a rich array of consumables and marketing material- 5 x Trifractional Tips
- 5 x GEN36 Tips
- 5 x GEN12 Tips
- 1 x TriPollar Gel
- 1 x REFORM Glycolic Acid Cleanser
- 1 x REFORM Hyaluronic Serum
- 1 x Pint of Sale Marketing USB
| Duetto Laser Quanta System
The device at a glance
The Duetto MT – EVO Family system is based on Alexandrite and Nd:YAG lasers, 755 nm and 1064 nm, in single or combined emissions. Duetto MT can meet the necessities of every patient by tailoring the treatments in every detail.
Big spot sizes, wide range of pulse widths and fast repetition rate together with the exclusive possibility to set the proportion between Alexandrite and Nd:YAG lasers through the Mixed Technology, make this device one of the most advanced and flexible laser in Aesthetics and Dermatology field especially for the Hair Removal, Vascular and Skin Rejuvenation treatments.
The TWAIN optional handpieces can be installed at any time on the field and can expand the range of applications even more.Mixed Technology
Duetto MT equipped with the second generation of consolidated proprietary Mixed Technology which is able to perform the largest range of hair removal applications, as well as vascular and rejuvenation treatments.
Duetto MT allows the operators to easily select single or double wavelength emissions adapting the treatment to all skin types more precisely.Contact Skin Cooler or Air Skin Cryo
Effective skin cooling is essential forost lasers.
The integrated contact skin cooler of Duetto MT can be used with or without a sapphire window at three different target temperature.
The Skin Cryo handpiece adapter, instead, is intended to work in combination with an external compatible air cooling unit to provide a cold air flow designed for the reduction of pain and thermal injury on wide areas.Duetto Laser Quanta SystemThe TWAIN options are based on IPL or laser handpieces that can also be installed at the clinic’s site any time.
Twain IPL option is based on Intense Pulsed Light technology, it has different optical filters or different handpieces that can have integrated skin cooling (depending on the model and wavelength). It is indicated for:
Hair Removal | Dermatological vascular treatments | Benign pigmented lesions | Skin rejuvenation | Active acne
Twain 2940 is an Er:YAG laser handpiece ideal for skin ablations with confined thermal diffusion for excellent safety scores. It is indicated for:
Normal spots: Skin ablation | Full skin resurfacing
Fractional: Skin resurfacing | Traumatic and acne scars | Epidermal dyschromia | Sun and age spots | Cutera Fraxis PROinclude Cutera Fraxis PRO :Fraxis PRO Refine – This light RF treatment dispenses radiofrequency energy via small microneedles at varying depths of the skin. It addresses fine lines, large pores, wrinkles, stretch marks, and acne scars in a series of 3-4 treatments that can be performed on all skin tones, any time of year, and has little to no downtime.
Fraxis PRO Ultra-Light – This light laser peel provides gentle exfoliation via CO2 laser technology. A series of 3 sessions is recommended.
Fraxis PRO Ultra – This CO2 technology smooths and enhances skin tone and texture. It also promotes collagen production t through fractional skin resurfacing in a single treatment.
Fraxis PRO Revive – This treatment combines both CO2 laser and RF microneedling in the same session. The Fraxis PRO Revive achieves dramatic results in 1-3 sessions and can be performed on fair to medium skin tones with up to a week of downtime. Fraxis PRO combines fraction CO2 for skin resurfacing and radiofrequency microneedling for total dermal remodeling. This combination of CO2 laser energy and radiofrequency microneedling, allows this device to treat a range of skin conditions including: fine lines, wrinkles, acne scars, burn scars and stretch marks.The device can be used on the face and body, and the treatments can be used alone or in combination based on the patients needs. The device includes the following:Fraxis PRO Refine. A light RF treatment dispenses radiofrequency energy via small microneedles at varying depths of the skin. It addresses fine lines, large pores, wrinkles, stretch marks and acne scars.Fraxis PRO Ultra-Light. A light laser peel that provides gentle exfoliation via CO2 laser technology. It’s a perfect prejuvenating treatment to prevent signs of aging or address current skin concerns, like uneven texture, dull skin tone and overall complexion quality.Fraxis PRO Ultra. A powerful CO2 technology peels back years of aging by smoothing, brightening and enhancing skin tone and texture. It also promotes collagen production to address scarring, and crepey skin through fractional skin resurfacing. Fraxis PRO Revive. A signature treatment combines both CO2 laser and RF microneedling technologies in the same session, delivering intense comprehensive skin renewal for aging skin. | 2017 Cutera Excel HR 1064nm & 755nm Hair RemovalAlexandrite | | Wavelength | 755 nm | Maximum Energy | 53J | Pulse Duration | 3 ms | Spot Size | 5-18 mm | Repetition Rate | 2 Hz | | | Nd Yag | | Wavelength | 1064 nm | Maximum Energy | 80J | Pulse Duration | 0.1 – 300 ms | Spot Size | 3-12 mm | Repetition Rate | Up to 10 Hz | Cooling | Contact Sapphire | Aiming Beam | 635 nm | Dimensions | 35″ H x 12″ W x 24″ D | Electricial | 200-240 VAC, 50/60 Hz, 20A/30A | | | Cooling | Contact Sapphire | Aiming Beam | 635 nm | Dimensions | 35″ H x 12″ W x 24″ D | Electricial | 200-240 VAC, 50/60 Hz, 20A/30A |
MANUFACTURER NOTES Superior, Comfortable Laser Hair Removal Laser Hair Removal – An In-demand Procedure Global hair removal procedures are growing at a rapid pace. Laser hair removal has been among the top non-surgical procedures according to the American Society of Aesthetic Plastic Surgery and procedure revenue is anticipated to go to $1.35B by 20221. The industry often refers to laser hair removal as a gateway procedure as it offers an entry point into the aesthetic market for patients and practitioners alike. excel HR combines a high-power 755 nm Alexandrite laser and Cutera’s proven long-pulse 1064 nm Nd:YAG laser for safe, effective high-volume hair removal on all skin types. The combination of wavelengths not only allows for effective hair removal, but is also a solution for epidermal pigmented lesions, vascular lesions, and Cutera’s signature laser genesis skin revitalization procedure. excel HR Technology Proven Wavelengths excel HR combines the gold standard laser wavelengths for hair removal. The 755 nm Alexandrite laser is highly absorbed by melanin making it an ideal solution for finer hair on skin types I-III. Because of the high melanin absorption characteristics, it has also been proven to provide long-term results on epidermal pigmented lesions. The 1064 nm Nd:YAG is the safest wavelength for permanent hair reduction on darker skin types and tanned skin. By selecting the appropriate spot size, this laser can also be used for treating facial and leg veins and perform laser genesis procedures. truPulse Delivery with Index Matching Unique to Cutera, the truPulse technology delivers constant, sustained energy throughout the pulse duration to ensure consistent performance and proven clinical outcomes for your patients. excel HR’s index matching delivery results in more efficient coupling of laser energy to target structures. Index matching allows backscattered light to escape, further protecting the epidermis from heat build-up while maintaining treatment efficacy. Superior Contact Cooling excel HR utilizes sapphire contact cooling to provide continuous cooling, maximizing your patients’ comfort and treatment safety. In a patient preference study that measured comfort and satisfaction for laser hair removal, 100% of the patient’s preferred excel HR over a comparable, competitive laser hair removal procedure. 321st Century Laser Hair Removal System Developed by the innovative leader in aesthetic laser technology, excel HR™ laser hair removal system provides advanced premium hair removal solutions for every skin type. Combining a new high-power 755 nm Alexandrite laser, and CUTERA’s proven long-pulse 1064 nm Nd:YAG laser, coupled with the superiority of sapphire contact cooling, excel HR redefines modern laser hair removal. This makes excel HR laser system an effective, safe and comfortable option for laser hair removal for the 21st century. Applications 2017 Cutera Excel HR 1064nm & 755nm Hair Removal - Hair removal
- Benign pigmented lesion removal – All Skin Types I-IV
- Veins, facial
- Veins, leG
- Laser Genesis
| 2019 Venus Concept Neo Graft 2.0
is a revolutionary automated Follicular Unit Extraction (FUE) and implantation technology that leaves no linear scar and is minimally invasive with fast patient recovery. It eliminates the inefficiencies of common manual tools and procedures while enabling physicians to offer hair transplants with consistent clinical outcomesADVANCED TECHNOLOGY2019 Venus Concept Neo Graft 2.0 system is the industry pioneer and market leader with one of the first automated FUE system in the hair restoration market. NeoGraftharvesting, site-making and implantation functions make it easier than ever for physicians to address hair loss and provide the hair restoration procedures that patients want. The inefficiencies of manual extractions and implants have been eliminated, and replaced it with advanced technology that provides patients with the benefits of the FUE procedure while also enabling physicians to perform fast, effective, safe hair transplants that yield superior clinical results.
OPTIMIZED WORK FLOW- Double-jointed arm and enhanced ergonomics ensure faster and more comfortable procedures for both patients and physicians Used Venus Concept Neograft 2.0 for sale
- New contra angle eliminates loss of fluid and protects grafts through vacuum seal
- Recipient site creation handpiece delivers more standardized implants
- No-touch implanter offers the least amount of bulb trauma
- Autoclavable handpieces offer sterilizable and cost-effective tools
PNEUMATIC MOTOR AND SMART DRIVE TORQUE TECHNOLOGY- Piston-driven motor delivers precise pressure control for both extraction and implantation
- Smart Drive Torque Technology delivers 100% torque to the contra angle/punch, for continuous rotation and the smoothest entry.
- Consistent suction and spin lead to standardized extractions, high quality grafts, and superior patient outcomes
INTUITIVE TOUCHSCREEN INTERFACE WITH GRAPHICAL USER INTERFACE (GUI)- Automatic, real-time extraction and implantation of graft counts eliminates manual counting and paperwork
- GUI delivers user friendly, intuitive, interactive experience
- Treatment screens allow users to easily switch between two modes – extraction and implantation
- User management tools help track and improve performance of treatment providers
OPERATIONAL EFFICIENCY WITH INTERNET OF THINGS (IOT) TECHNOLOGY AND DEVICE MOBILITY- Advanced IoT technology capabilities enhance business operations by optimizing treatment protocols, improving patient results & satisfaction, and maximizing operational efficiency & ROI
- Quiet operation and energy-efficient usage
- Device occupies less than 5 sq. ft. and weighs 36 Kg with storable pedals and 360-degree turning
|
Reviews
There are no reviews yet.