| Description | The Canon Aplio 300 Platinum lowers the price by removing its standard option, but still uses the same system architecture like the Aplio 500 Platinum and the Aplio 400 Platinum, which a user can enjoy a great fundamental image quality of those two higher grade systems. The Canon Aplio 300 is positioned as a high-end grade system, and holds a very good reputation in Radiology with a wide selection of intraoperative transducers, superb fundamental image quality, and outstanding and dedicated premium radiology options such as Smart Fusion, Shear Wave, and Contrast Harmonic Imaging (CHI) | 2015 Active Optical Extra 818 IPL Hair Removal and Skin Rejuvenation; Excellent Cosmetic and Operating Condition, Very Lightly Used for Demonstrations Only, Single Owner; Included Handpieces and Pulse Counts: Hair Removal Handpiece = 6,617 Pulses, Facial Handpiece = 2,190, Life for Each Handpieces is 250,000 Pulses. | - This Multi-function system offers a wide range of treatments.
- 1046nm long pulsed Nd:Yag treating hair removal, fungal nail and deep thread veins.
- 650nm & 585nm IPL handpieces including for both hair removal, skin rejuvenation, thread veins, pigmentation and more.
- This system can be added to with a 2940 fractional handpiece
- Safety goggles supplied
- Delivery, installation and warranty included.
| Rotor-Gene Q 5plex is a Real-time PCR cycler and High-Resolution Melt analyzer with 5 channels (green, yellow, orange, red, crimson) plus HRM channel, laptop computer, software, accessories: includes 1-year warranty on parts and labor, installation and training not included | The M6 therapy laser is a robotized multi-target device designed to treat patients suffering pathologies affecting a wide area, and to perform automatic applications. The distinctive feature of the M6 is the innovative multi-target functioning. Thanks to the features of the exclusive MLS multi-diodic optical group, a wide area is treated instantaneously helping to produce an immediate response of the treated tissues. The results are better and faster than with the scanning modality of traditional laser therapy products. | Let’s Face It! We want to look our best at any age—not over-filled and over-stretched, just natural. We want to age gracefully, beautifully and elegantly. Inevitably, fine lines and wrinkles set in, and now there is a simple, minimally-invasive treatment that will address those concerns and have you out to dinner that same night. |
| Content | Canon Aplio300 CV Platinum Ultrasound MachineThe Canon Aplio Platinum series share the system architecture; therefore, functions in a manner similar to and are intended for the same use. The systems are overall heavier and larger than newer GE and Philips products; however, the Canon Aplio Platinum series became stable and reliable due to the last 4 to 5 consecutive upgrades since its initial launch in 2012.The Canon Aplio 300 Platinum lowers the price by removing its standard option, but still uses the same system architecture like the Aplio 500 Platinum and the Aplio 400 Platinum, which a user can enjoy a great fundamental image quality of those two higher grade systems. The Canon Aplio 300 is positioned as a high-end grade system, and holds a very good reputation in Radiology with a wide selection of intraoperative transducers, superb fundamental image quality, and outstanding and dedicated premium radiology options such as Smart Fusion, Shear Wave, and Contrast Harmonic Imaging (CHI).The Canon Aplio Platinum series provide a number of clinical tools that provide wider clinical utilities and save scanning time by providing better visualization in a short time. The Superb Micro Vascular Imaging (SMI) is one that increases physician’s clinical productivity and diagnostic efficiency with better visualization of low-velocity blood flow. The MicroPure function is the function that increases comfort and confidence of diagnosis by better visualizing small structures such as a small calcification in breast. The Canon Aplio Platinum series support unique linear (PLT-308P) and convex (PVT-350BTP) transducers that much improve the needle biopsy procedure by offering the method that a needle can be inserted and visualized in the middle of transducer, not from the edge of a transducer.The Canon products in general look like a technology oriented product, rather than a clinical oriented product. With this series, Canon has achieved fully digital beamforming technology, which is fully integrated into the Aplio Platinum series. The weight of each Platinum series is still high, above 320 lbs. The monitor size is 17-inches, but upgradable to 19-inches. Although the Canon Aplio Platinum holds good quality and reputation in Radiology, they still need to be improved in cardiology and OB/GYN’s workflow, automation, and 4D quality, comparing GE or Samsung products to satisfy customers.
CANON APLIO 300 CV PLATINUM ULTRASOUND MACHINE Canon Aplio 300 Platinum Probes/Transducers:Convex Probe
PVT-375BT(6C1)
PVT-375SC(6Cs1)
PVT-674BT(9C3)Micro Convex Probe
PVT-382BT(6MC1)
PVT-712BT(11MC4)Endo Cavity Probe
PVT-661VT(9C3)
PVT-674BT(10C3)
PVT-781VT(11C3)
PVT-781VTE(11C3)3/4D Convex Probe
PVT-375MV(6CV1)
PVT-382MV(6MCV1)
PVT-675MV(8CV2)
PVT-675MVL(9CV2)
PVT-681MV(9CV3)
PVT-681MVL(11CV3)
PLT1204MV(12LV7)Intra Operative Probe
PVT-350BTP(6CP1)
PVT-745BTF(11CI4)
PVT-745BTH(11CI4)
PVT-745BTV(11CI4)
PLT-705BTF(11LI4)
PLT-705BTH(11LI4)Hockey Stick Probe
PLT1202S(14L7)BI Plane Probe
PVL-715RST(11CL4)Linear Array Probe
PlT-308P(6LP3)
PLT-604AT(10L4)
PLT-704AT(11L5)
PLT-704SBT(11L4)
PLT-705BT(11L3)
PLT-805AT(12L5)
PLT-1005BT(14L5)
PLT-1204BT(18L7)
PLT-1204BX(18LX7)Sector Probe
PST-25BT(5S1)
PST-30BT(5S2)
PST-50BT(6S3)
PST-65AT(9S4)TEE
PET-508MA(7S3)
PET510MA(7S3)
PET-510MB(7S3)
PET-511BTM(8SM2)
PET-512MA(8S2)
PET-512MC(8SM2)
PET-512MD(8SM2)Laparoscopic Probe
PET-805LA(12LI4)Pencil Probe
PC-20M(P2)
PC-50M(P5) Features:• 19-inch LCD monitor
• DVD/CD drive
• ApliPure+(Spatial Compounding)
• Quick Scan
• TDI
• QSP
• HPRF
• DICOM Media Storage Options:• CW Kit
• ECG, PCG, and Pulse sensor
• Mounting Kit for Peripheral Unit
• Footswitch
• Gel Warmer
• M-TEE Hanger Kit
• 4D Unit
• Battery Kit
• Transducer Holder(Right) Kit
• Transducer Holder(Left) Kit
• Transducer Cable Hanger Kit
• CV Kit
• Wireless LAN Kit
• DICOM Kit
• Stress Echo Kit
• 2D Wall Motion Tracking Kit
• CHI Kit
• ApliPureTM Plus Kit
• Differential THI Kit
• Precision Imaging Kit
• Tissue specific Optimization Kit
• 4D STIC Imaging Kit
• Luminace Kit
• Smart 3D Kit
• Protocol Assistant Kit
• Superb Micro Vascular Imaging Kit
• Trapezoid Scan Kit
• Dynamic FlowTM Kit
• MicroPureTM Kit
• Ealstography-FLR Kit
• Elastogrpahy Kit
• FLR Kit
• Shear wave Kit
• Panoramic View Kit
• Vascular Index Kit
• FLEX-M Kit
• Auto NT Kit
• Probe 4 Port Kit
• Security Management Kit
• Local Language Key-Top Kit Applications : Canon Aplio300 CV Platinum Ultrasound Machine• Abdomen
• Women’s Helacre Care(GYN & Breast)
• Obstetrics
• Fetal Echo
• Vascular
• Transcranial
• Small Parts(Breast, Thyroid, Testis…)
• MSK/Anesthesiology
• Pediatrics
• Urology (Renal, Prostate…)
• Adult Echocardiography
• Pediatric Echocardiography
• Neonate Echocardiography
• Stress Echocardiography
• Adult Transesophageal Echocardiography
• Pediatric Transesophageal Echocardiography
• Internal Medicine w/ Shared Service
• Surgery
• Interventional Radiology
• Contrast Imaging_General Imaging
• Contrast Imaging_Cardiac
• Bowel Imaging
• Strain Elastography | Active Optical Extra 818 IPL Hair Removal 2015Handpieces:Hair Removal Handpiece and Facial Handpiece
Chilled Tip:Up to 4c
Pulse Interval:0.5~2 Seconds
Output Power:11-31 joule/cm2, upto 4,000W
Cooling System:Revolutionary dual cooling
Control:Intuitive touch screen control
Lamp’s Life Span:250,000 Flashes (Universal), 200,000 Flashes (Facial)
Treatment Area:7.5 cm2 (15*50mm) Universal, 4.5 cm2 (15*30mm) Facial
Wavelength:420-1100 nm
Weight:42Kg (including Stand, if device is not a table top)
Dimensions:44cm x 45cm x 100cm Extra-818Skin Rejuvenation
Pigmentation Treatment
Acne Treatment
Hair Removal
Vascular (Facial) TreatmentThe Extra – 818 is the outcome of more than a decade of treatments and thousands of devices operated worldwide. It contains It contains unique features:
* Contemporary touch screen control
* Built-in Patch Test procedure for examining the optimal energy level
* A stunning number of 450,000 flashes in both lamps.The Extra – 818, based on Active’s GEM-PL technology, sets sets a specific Pulse Pattern according to the selected treatment type, skin color, skin photosensitivity and treatment depth.
The treatment protocols and different pulse patterns take into account the tissue’s TRT (Thermal Relaxation Time) and the combined knowledge accumulated from thousands of treatments done during the years and clinical investigations done to confirm the findings.The combination of tested treatment protocols with high end engineering makes the Extra – 818 the perfect device for leading clinics.Revolutionary Cooling System
The Extra – 818 has a dual cooling system, controlled and monitored in order to ensure long lifetime to the lamp and a comfortable treatment to the patient.Competitive cooling systems “freeze” the skin so that during the treatment the skin temperature will rise to a bearable level. However, this “freezing” temperature might limit the results because the follicles will not reach the coagulation temperature. To ensure optimal results Active installed a special Processor that prevents overcooling the skin and maintains a uniform low temperature of the “glass” throughout the treatment. This revolutionary system enables the Extra – 818 to provide best results with optimal patient comfort.Research Program Active Optical Extra 818 IPL Hair Removal 2015
For clinical investigations, the self setting program allows researchers to set the treatment’s parameters according to their needs. Allowing advanced research with the device.
The energy levels in the self setting program can reach 31Jcm2 with high intensity of 4,000W. | Lynton Lumina IPL HR Laser
2013 Lynton Lumina IPL HR Laser Hair Removal 650nm 585nm 1064 YAG Beauty MachineIn very good condition and full working order
Purchase new in December 2013, so less than a year old
Laser has minimal use total count of 29427 from newPlease click HERE for further information
Included:-
1 x 2013 Lynton Lumina IPL YAG Laser Hair Removal Beauty Machine
1 x Lynton 650 IPL Handpiece in protective storage box – Total Handpiece Shots 21600
1 x Lynton 585 Plus IPL Vascular Handpiece in protective storage box – Total Handpiece Shots 385
1 x Lynton 1064 YAG Laser Vascular Handpiece with 3mm, 6mm, 8mm tips in protective storage box – Total Handpiece Shots 7442
1 x Set of 3 IPL light guides in protective storage boxFor the following treatments
650nm Hair removal
650nm C.F.TMachine can do the following
585nm Vascular Plus
585nm Pigmentation Plus
585nm Photorejuvenation Plus
585nm Acne Plus
The ultimate ‘build as you grow’ laser & IPL machine, offering practitioners the opportunity to dramatically increase and extend their treatment portfolio, without having to purchase numerous devices. British manufactured and listed on the NHS Supply Chain, the LUMINA offers the UK’s most in-demand treatments; hair removal, tattoo removal, anti-ageing and skin resurfacing.Highly versatile, and with numerous revenue capabilities, the Lumina delivers fast and clinically effective treatment results with superior efficacy. As the best-selling multi-function aesthetic machine, the LUMINA has a proven track record of building, growing and establishing clinics as the No.1 in their area.As our flagship machine, and the product of over 20 years expertise in the design, development and manufacture of laser/IPL systems, the LUMINA is specifically designed to be adaptable to address emerging applications. As well as unrivalled laser technology, the LUMINA has a built-in patient database and parameter printer, and benefits from its easy-to-use touchscreen. 1. Intense Pulsed Light (IPL): the perfect combination of hair removal and skin rejuvenation treatments come as standard with the LUMINA system via its 585 & 650 handpieces.Hand-piece
Type Wavelength(s) Maximum
Fluence Treatments Spot Sizes Maximum
rep. rate
585 Intense
Pulsed Light 550 – 1100nm 50J/cm2 Superficial Vascular
Superficial Pigmentation
Active Acne
Skin-rejuvenation 1x1cm
2.5x1cm
5x1cm
1cm circular 1Hz
650 Intense
Pulsed Light 625 – 1100nm 40J/cm2 Hair removal (1 to 5)
Collagen treatment 1x1cm
2.5x1cm
5x1cm
1cm circular 1Hz
650 Advance IPL hand-piece, which has been designed to provide faster results in hair removal of finer, lighter hairs found on the face and navel. The 650 Advance hand-piece has software optimised for the greater power it delivers, allowing experienced practitioners to treat finer and fairer hairs successfully, in skin type 1 to 3 clients in a single or dual pulse mode. | Rotor-Gene Q 5plex HRM
Each tube spins in a chamber of moving air, keeping all samples at precisely the same temperature during rapid thermal cycling. Detection is similarly uniform. When each tube aligns with the detection optics, the sample is illuminated and the fluorescent signal is rapidly collected from a single, short optical pathway.This thermal and optical uniformity results in sensitive, precise, and fast real-time PCR analysis (see figure “Precise real-time PCR analysis”). It also eliminates sample-to-sample variations and edge effects. These are unavoidable in traditional block-based instruments due to temperature gradients across the block and multiple, complex optical pathways. The rotary design delivers well-to-well variation ±0.02°C Uniform detection eliminating the need for ROX reference dye Fast ramping and negligible equilibration times for short run times Complete confidence in your results!The unrivaled optical range enables multiple applications Whether your essay is based on intercalating dyes such as SYBR Green, probes such as hydrolysis (TaqMan), hybridization (FRET), Scorpion probes, or other multiplex chemistries, the Rotor-Gene Q meets your requirements. With up to 6 channels spanning UV to infrared wavelengths, the cycler delivers the widest optical range currently available (see Table “Channels for optical detection”). In addition, the software allows you to create new excitation/detection wavelength combinations, which means that the Rotor-Gene Q is compatible with dyes you may use in the future.The unique centrifugal design of the Rotor-Gene Q 5plex HRM ensures optimal thermal and optical uniformity between samples, which is critical for precise and reliable analysis . Each tube spins in a chamber of moving air, keeping all samples at precisely the same temperature during rapid thermal cycling. Detection is similarly uniform. When each tube aligns with the detection optics, the sample is illuminated and the fluorescent signal is rapidly collected from a single, short optical pathway. This thermal and optical uniformity results in sensitive, precise, and fast real-time PCR analysis. The rotary design delivers up to 20 times better thermal precision in real-time cycling compared with traditional block-based instruments. Have complete confidence in your real-time PCR test by using highly precise rotary technology. Robust optical range enables multiple applications
With a choice of up to 6 excitation sources and 6 detection filters, combined with a short, fixed optical path, the
Rotor-Gene Q MDx 5plex HRM can be used for multiplex reactions (see table), ensuring minimum fluorescence variability between samples and eliminating the need for calibration and compensation. | Blue | 365 ± 20 | 460 ± 20 | Marina Blue, Edans Bothell Blue, Alexa
Fluor 350, AMCA-X, ATTO 390 | | Green | 470 ± 10 | 510 ± 5 | FAM, SYBR Green I, Fluorescein,
EvaGreen, Alexa Fluor 488 | | Yellow | 530 ± 5 | 557 ± 5 | JOE, VIC, HEX, TET, CAL Fluor
Gold 540, Yakima Yellow | | Orange | 585 ± 5 | 610 ± 5 | ROX, CAL Fluor Red 610, Cy3.5,
Texas Red, Alexa Fluor 568 | | Red | 625 ± 10 | 660 ± 10 | Cy5, Quasar 670, LightCycler
Red640, Alexa Fluor 633 | | Crimson | 680 ± 5 | 712 high pass | Quasar 705, LightCycler Red705,
Alexa Fluor 680 | | HRM | 460 ± 20 | 510 ± 5 | SYBR Green I, SYTO9, LC Green,
LC Green Plus+, EvaGreen |
Minimum maintenance; maximum convenience
The Rotor- Gene Q 5plex HRM is engineered to reduce the need for maintenance and to maximize ease of use. This saves time and costs, and keeps the instrument operational for continuous testing. The outstanding robustness of Rotor-Gene technology is proven in several thousand installations worldwide.Convenient features of the Rotor-Gene Q MDx 5plex HRM include: - Lifetime guarantee on highly stable LEDs, no expensive and time consuming lamp replacement, and no gradual performance loss
- Cost-effective and easy temperature-accuracy verification (see below)
- Optical calibration not required at installation, or when the instrument is moved
- “Plug and play” connectivity between computer and instrument
- No sample block to clean
- No condensation or bubbles in the reaction due to rotation
- Small, light, and robust instrument — simply place it where you want it
Procedure Nucleic acids are purified using the designated manual or automated purification kit that is validated for the downstream assay. After assay setup, the assays are then transferred to the Rotor-Gene Q MDx 5plex HRM for PCR and data analysis. Easy routine verification
Certified laboratories often want to verify thermal accuracy. For most cyclers, this usually requires interaction with a service engineer. With the Rotor-Gene Q MDx 5plex HRM, this is not necessary. Instead, the easy-to-use, cost-effective proprietary Rotor-Disc OTV (Optical Temperature Verification) Kit automates temperature accuracy testing. The full procedure takes less than 30 minutes and can be performed by any user.Applications The Rotor-Gene Q MDx 5plex HRM is intended for in vitro diagnostic use. The Rotor-Gene Q MDx 5plex HRM instrument is intended to be used only in combination with QIAGEN kits indicated for use with Rotor-Gene Q MDx 5plex HRM instruments for applications described in the respective QIAGEN kit handbooks. Software Software enables quantification and enhances data security
The user-friendly software provides simplicity for the routine user, as well as an open platform for the more advanced developer. Standardization in your laboratory is supported by software wizards, templates for run, processing, and analysis procedures, and various pre-defined report formats.Data security, from starting the run to exporting the results, is assured by audit trails, digital signatures, and individual user management. Each Rotor-Gene Q MDx 5plex HRM instrument is supplied with an unlimited software user license for your institute, enabling you to access and analyze your test results on as many computers as you want — in the laboratory or in the office.Features | Specifications | | Altitude | Up to 2000 m (6500 ft) | | Dimensions | Width, 37 cm (14.6 in.); Height, 27.5 cm (10.8 in.); Depth (without cables), 42 cm (16.5 in.); Depth (door open), 56 cm (22 in.) | | Heat dissipation/thermal load | Average, 0.183 kW (632 BTU/hour); Peak, 0.458 kW (1578 BTU/hour) | | Humidity | 10–75% (noncondensing) | | Operating temperature | 18–30°C (64–86°F) | | Optical System | 5 channels plus HRM; Excitation sources: high-energy light-emitting diodes; Detector: photomultiplier; Acquisition time: 4 seconds | | Overvoltage category | II | | Place of operation | For indoor use only | | Pollution level | 2 | | Power | 100–240 V AC, 50–60 Hz, <520 VA (peak); Power consumption 8 VA (standby); Mains supply voltage fluctuations are not to exceed 10% of the nominal supply voltages; F5A 250 V fuse | | Samples per run (throughput) | Tubes 0.2 ml, 36 samples/run; Strip Tubes 0.1 ml (4 tubes), 72 samples/run; Rotor-Disc 72, 72 samples/run; Rotor-Disc 100, 100 samples/run | | Software | Rotor-Gene Q software, supplied on the installation CD provided | | Storage conditions | 15–30°C (59–86°F) in manufacturer’s package; Max. 75% relative humidity (noncondensing); Environmental class 1K2 (IEC 60721-3-1) | | Technology | Real-time PCR cycler | | Thermal performance | Temperature range, 35–99°C (95–210.2°F); Temperature accuracy, ±0.5°C (calibrated using Rotor-Disc OTV procedure); Temperature resolution, ±0.02°C (smallest programmable increment); Temperature uniformity, ±0.02°C | | Transportation conditions | –25°C to 60°C (–13°F to 140°F) in manufacturer’s package; Max. 75% relative humidity (noncondensing); Environmental class 2K2 (IEC 60721-3-2) | | | | Weight | 12 kg (26.5 lb.), standard configuration |
| Cutting Edge MLS M6 Laser Therapy Unit
The M6 therapy laser is a robotized multi-target device designed to treat patients suffering pathologies affecting a wide area, and to perform automatic applications. The distinctive feature of the M6 is the innovative multi-target functioning. Thanks to the features of the exclusive MLS multi-diodic optical group, a wide area is treated instantaneously helping to produce an immediate response of the treated tissues. The results are better and faster than with the scanning modality of traditional laser therapy products.Technical Features
Robotized optical group with 3 MLS sources – power up to 3.3 W
5 cm diameter target area highlighted by high-efficiency red light LEDs
Back-lit graphic touch-screen display
Simultaneous management of two independent channels
MLS pulse modulation frequency from 1 to 2000 Hz with 1 Hz steps
Power level 50% and 100%
Variable or fixed duty cycle
Treatment duration from 1″ to 99’59” with 1″ steps
Automatic calculation of the emitted energy according to the set parameters
Alarms and Safety Features
Laser emission warning light
Interlock (can be temporarily disabled)
Acoustic signal for the beginning and the end of the therapy, and for each treatment second (can be disabled)
Password to operate the device
Language option (Italian, English, German, Spanish)
Dimensions and Weight
27 x 17 x 62 inches; 95 lbsPower Supply
115/230V~ 50/60Hz 150VACUTTING EDGE MLS M6 Laser Therapy UnitTalk to your specialist.
Since 1983 we have been working to be the reference point in Laser Therapy and Magnetotherapy in many areas: from physiotherapy to rehabilitation, from the management of muscle and joint pain to sports medicine. The result of our work allows us today to be recognized as an international leader in the knowledge and development of advanced technologies in the field of “pain management”: a recognition confirmed in 2003 with the entry of the El.En Group. (Star segment of the Italian Stock Exchange – ELN.MI), one of the most important realities in the laser world, both for industrial and medical applications.We have always thought that research is not only confirmation, but also the necessary premise for our work. Born from the synergy between ASAlaser and the Department of Experimental and Clinical Biomedical Sciences of the University of Florence , the ASAcampus laboratory allows us to test the validity of our work and improve results over time. The result of the research is disseminated through conferences, supported thanks to important partnerships and disseminated through numerous scientific publications.Our medical devices for MLS ® Laser Therapy , Hilterapia ® and Magnetotherapy are built according to contents that we consider indispensable: advanced technologies and software, efficacy and safety, ergonomics and design. They allow for ever more targeted and personalized treatment methods. The effectiveness of our therapies is continuously tested thanks to the research carried out in ASAcampus whose results are constantly transferred to clinical applications. | 2018 Vivace RF Microneedling Radio Frequency Acne ScarsTHE VIVACE EXPERIENCE
The most exciting new technology for aesthetic treatments is the combination of two methods previously used individually for skin rejuvenation, Microneedling and RF Energy. FDA-cleared for your safety, the newest generation, best-in-class Vivace RF Microneedling device, is designed for an incomparable, comfortable experience. Only Vivace boasts a precision robotic motor that brings discomfort to a virtual zero compared to any other device. The results are immediate and improve over time as well, giving you the best of both worlds. Our carefully developed recovery system ensures no one knows you just had a treatment. If you are looking for optimal results, there is no comparison to The Vivace Experience.What is Vivace Fractional RF Microneedling?
The Vivace RF Laser Radio Frequency is the newest generation of microneedling with radio frequency and is effective for fine lines and wrinkles, skin tightening, acne, acne scars, and skin tone, texture and pore size, both on and off the face. It is the most revolutionary contouring and skin tightening system for face, neck, hands and body available, producing immediate, pain-free results.Safe for all skin types, Vivace can offer similar results as ablative and fractional laser procedures, but with significantly less discomfort, downtime, and risk of complications. This revolutionary new treatment also addresses the limitations of older ‘traditional’ RF treatments and heats deeper tissues to a much higher level, which leads to greater collagen production, elastin remodeling and wound contraction previously unattainable with older technology. This is why the Vivace is a game changer in skin rejuvenation and tightening. CLICK HERE to learn moreSlate combines the best device with the newest breakthroughs in numbing, treatment serums and recovery care to create an optimal experience for you that might just keep you from needing other more invasive procedures down the road. The Vivace Experience provides the most dramatic results with less pain and less downtime. The results are both immediate and improve over time with multiple treatments. With results you can see, you’ll look and feel your best at any age.Slate Medspa is the premier Fractional RF Microneedling provider in NJ. We use the most advanced technology to provide a results-oriented skin rejuvenation program. New to Slate Medspa? Call us today at 201-477-5781 to schedule a free consultation and save 20% off your first treatment.How does Vivace Fractional RF Microneedling work?
The Vivace utilizes radio frequency and microneedling to heat the targeted area underneath the epidermis. The Vivace dramatically improves the treatment outcomes compared to other radio frequency microneedling systems.By using insulated needles, Vivace bypasses the epidermis and delivers powerful RF thermal energy to create tens of thousands of fractional coagulation zones in the dermis, facilitating a natural wound healing process. This promotes production of new collagen, remodeling of elastin and wound contraction, enhancing skin laxity. Because the thermal energy is delivered beneath the top layer of skin,Benefits of VIVACE:2018 Vivace RF Microneedling Radio Frequency Acne Scars
Minimizes/Eliminates Fine Lines and Wrinkles
Minimizes/Eliminates Acne Scars & Stretch Marks
Skin Tightening & Texture – Stimulates collagen and elastin production
Treat Sun Damage/Age Spots/Hyperpigmentation
8 Reasons why Slate LOVES Vivace™ RF Microneedling
You’ll see results quickly
Vivace works faster than any other microneedling or laser option. First, the RF Energy creates micro injuries deep in the skin in the form of a matrix. Healthy cells around the newly created matrix promote rapid healing, accelerating collagen production and skin tightening. Secondly, the invisible microchannels in the skin created by the superfine gold-tipped needles remain open for four to six hours allowing maximum absorption the key nutrients and serums applied during the treatment. This would include growth factors, HAs and other cosmeceuticals delivered to the skin in a way that no other treatment can, helping to rapidly rebuild new collagen and elastin.The average patient gets optimal results in just three treatments
Most patients experience noticeably softer, smoother and radiant skin, with improvements in tone, texture and laxity after just one treatment. We can typically achieve optimal results after only three sessions!The treatment is virtually painless
The Vivace Microneedle RF was designed for an incomparable, comfortable patient experience. The unique robotic motor is so precise, it brings the discomfort level to a virtual zero as compared to any other device. The Vivace’s ultra thin needles make it virtually pain-free. A numbing cream is applied before treatment for you to stay comfortable. Our patients here at Slate Medspa consistently report a pain level of “1” on a scale of 1 to 10.There’s no downtime
Vivace’s ultra-thin needles and robotic-assisted mechanism result in an exceptionally precise, even treatment with little-to-no bleeding. In addition, built-in LED Light therapy minimizes post-treatment redness. While we ask patients to wait until the next day before applying makeup, most feel comfortable going out without any makeup.It’s safe for almost any skin type
Patients with darker skin tones can have a more challenging time finding suitable skin resurfacing treatments, as lasers and peels that remove skin layers can risk permanent pigmentation changes. Vivace has 31 Adjustable depths, providing flexibility in treating entire depth or just down deep, bypassing damage to the top layer of skin. This means we can treat a broader array of skin types and tones with absolute precision. In addition, a variable pulse duration means the length of time the needle is engaged with tissue can be precisely controlled based on your skin profile. |
Reviews
There are no reviews yet.