| Description | The Agilent 6460C Triple Quad LCMS with 1260 Infinity HPLC System is equipped with Agilent Jet Stream Technology to enable enhanced sensitivity. The 6460 provides a fast and robust solution to simultaneously quantify, screen, and confirm analytes in the laboratory. | The ability to work specifically in the deep dermis, without damaging the epidermis, is regulated in the RF Secret by the delay time of fractional radiofrequency. The needles are inserted at a rate of milliseconds equal to a stamping process in the skin and also withdrawn immediately. Only after the needles are penetrated into the desired skin layer, is carried out for a few milliseconds, a radio frequency pulse to set heat damage. While the penetration into the skin, the needles remain always cold. In order to achieve a deep and superficial effect, the needle depths can be varied individually in the respective treatment passes. | Highest available power allows for fast treatments, customizable for multiple areas
Gentle, effective global improvement for all skin types, all year-round
Comfortable treatments with very little downtime
Minimal cost of ownership, easy to delegate and no shot limit per procedure | The budget friendly LOGIQ P9 – a general imaging system designed for quick diagnostic exploration and full schedules. The LOGIQ P9 enables clinicians to make timely, confident decisions. | Let’s Face It! We want to look our best at any age—not over-filled and over-stretched, just natural. We want to age gracefully, beautifully and elegantly. Inevitably, fine lines and wrinkles set in, and now there is a simple, minimally-invasive treatment that will address those concerns and have you out to dinner that same night. | Laser Hair Removal
Details:- Serial Number: SQEAY-19M-XXXXX (message for serial number)
- System Total Shot Count: 560,693
- Alex Shot Count: 221,437
- YAG Shot Count: 339,256
Includes:- Handpiece and Delivery System
- Square Spot Sizes: 2x2mm, 3x3mm, 5x5mm, 10x10mm, 14x14mm, 18x18mm, 20x20mm, 24x24, 27x27mm
- Fiber Pole
- Foot Switch
- System Key
- Operators Manual
- 30 Day Parts and Labor Warranty
|
| Content | AGILENT 6460C TRIPLE QUAD LCMS WITH 1260 HPLCThe AGILENT 6460C TRIPLE QUAD LCMS WITH 1260 HPLC is equipped with Agilent Jet Stream Technology to enable enhanced sensitivity. The 6460 provides a fast and robust solution to simultaneously quantify, screen, and confirm analytes in the laboratory.
Features:Excellent sensitivity for many applications
1 ms dwell time with no collision cell cross talk
Very fast polarity switching for multi-analyte studies
Dynamic Multiple Reaction Monitoring (d.M.R.M) to maximize MRM efficiency
Triggered Multiple Reaction Monitoring (t.M.R.M) for simultaneous quantitation and confirmationThe Agilent Infinity Binary LC offers the most flexibility for solvent selection and automation in HPLC method development, research, and all HPLC applications requiring continuous access to a wide range of solvent choices. The availability to rapidly switch between methods using different solvents and the capability of using binary, ternary or quaternary solvent gradients make the Agilent 1260/1290 Infinity Binary LC the most flexible system on the market.Includes:Agilent 6460 Triple Quad LC/MS/MS
Jet Stream ESI Source
Mass Range: m/z 5 – 3,000
Agilent 1260/1290 HPLC
Solvent Tray
Degasser
Autosampler
Binary Pump
Thermostat
Thermostatted Column Compartment (TCC)
Mechanical Pump
Data System
Warranty CoverageOptions:MS Sample Introduction
Generator
Air Compressor
Workbench
Installation & Familiarization
Extended WarrantyIncludes:Solvent Tray
Degasser
Auto sampler
Binary Pump
Thermostat
Thermos-tatted Column Compartment (TCC)Specifications:AGILENT 6460C TRIPLE QUAD LCMS WITH 1260 HPLCMRM Sensitivity Signal-to-Noise: 1pg of reserpine injected: S/N>10,000:1
MRM Sensitivity Signal-to-Noise: 1pg of chloramphenicol injected: S/N>3,000:1
Mass range: m/z 5 – 3,000
Polarity switching: 30 ms
Mass resolution: Full width at half maximum 0.7Da
Mass accuracy: 0.1 DA from 5 – 1,000 m/z, 0.01% from 1,000 – 2,000 m/z, 0.02% from 2,000 – 3,000 m/z
Mass stability: < 0.1 DA in 24 h
Dynamic range: > 6.0 × 106
Maximum scan rate: 12,500 Da/s
Minimum M.R.M dwell time: 1 ms
MRM transitions: 450 per time segment, > 13,500 ion transactions per method
Dynamic M.R.M transitions: 4,000 ion transitions per method
Collision cell ion clearance: < 1 msFeatures:- Greater signal and reduced noise – Agilent Jet Stream technology uses super-heated nitrogen to improve ion generation and desolvation
- Efficient analysis – fast MRM speeds allow for analysis of over 100 overlapping compounds in a given retention time window
- Screen, confirm and quantify – Triggered MRM (tMRM) combines fast and sensitive MRM quantitation with the generation of a product ion spectrum for library searching and compound screening and confirmation
- Fast polarity switching for analysis of both positive and negative ions
| CUTERA SECRET RF 2.0CUTERA SECRET RF 2.0 MICRONEEDLING RADIO is a fractional micro-needling system (fractional radiofrequency) that exceeds the capabilities and limitations of fractional laser significantly. It is a system for extensive skin structure improvement and treatment of hyperhidrosis (radio frequency thermotherapy RFTT), based on both monopolar and fractionated on, bipolar radio frequency. An exact adjustment of the depth of the microneedles and the cold passing the epidermis allow the energy output directly into the target layer.
The needle depth is 0.5 mm to 3.5 mm can be varied, thereby opening up a wide range of treatments. The adjustable intensity of the RF energy allows for the treatment of various areas of the body with different energy performance.The ability to work specifically in the deep dermis, without damaging the epidermis, is regulated in the RF Secret by the delay time of fractional radiofrequency. The needles are inserted at a rate of milliseconds equal to a stamping process in the skin and also withdrawn immediately. Only after the needles are penetrated into the desired skin layer, is carried out for a few milliseconds, a radio frequency pulse to set heat damage. While the penetration into the skin, the needles remain always cold. In order to achieve a deep and superficial effect, the needle depths can be varied individually in the respective treatment passes.Dermal Remodeling from the Inside Out
Demand for non-surgical aesthetic procedures with little to no downtime is on the rise. More than 70% of patients are bothered by signs of aging such as fine lines and wrinkles as well as skin texture and discoloration.1Secret RF is a novel fractional radio frequency (RF) micro-needling system for tissue coagulation and hemostasis designed to stimulate and remodel collagen and address the common signs of aging. It is ideally suited for use on patients who wish to revitalize and refresh the appearance of their skin on all skin types. By adjusting the micro-needles, Secret RF can deliver energy at various depths, so that treatments can be tailored to address each patients individual concerns such as fine lines, wrinkles, acne scars, photoaging and striae at the depth required.Secret RF System
Secret RFs unique technology and customized delivery of energy enables providers to tailor treatments for a variety of skin concerns on all skin types.Customized Dermal Remodeling
Secret RF induces dermal remodeling by applying precisely controlled RF energy directly into various depths of skin from 0.5-3.5 mm – with minimally invasive micro-needles to spare the epidermis and reduce patient downtime.Skin Revitalization and Resurfacing Secret RF is a radio frequency (RF) fractional microneedling system that helps you deliver tailored energy to improve fine lines, wrinkles, and scars from the inside out. Secret RF in action
Applications include fine lines and wrinkles, photoaging, scarring, acne scars, striaeSecret RF technology Handpieces
Two sizes of treatment tips – 25 and 64 pin – give you customizable options for treating the face and body with precision and efficiency.
Power:20 W ± 20%
RF frequency:2 Mh ± 20%
Intensity:0 ~ 100 Level (10 levels)
Repeat:0.2 / 0.5 / 1/2 sec / individually.
Needle Size:0.3 mm
Info about needles:25 electric needles (5 x 5, 7.8 mm x 7.8 mm / height: 1.95 mm (standard) and 16 electric needles (4 x 4, 7.8 mm x 7.8 mm / height 2.6 mm (optional)
Treatment range:1 x 1cm
Adjustable Depth:0.5 ~5 mm (0.1 steps)
Treatment duration:50 ms ~ 950 ms
Electrical power:100 ~ 240 VAC, 50/60 Hz, 220 VAMonopolar RF
Power:520 W ± 20%
RF frequency:2 Mh ± 20%
RF electrode:monopolar
Repeat:CW
RF electrode size:15APPLICATIONSFacialsNon-surgical facelift
Skin tightening
Pore reduction
Wrinkle reduction
Skin Rejuvenation (illumination)
Acne scars
Body treatmentsScar
Keratosis pilaris (Keratosis pilaris)
Stretch marks | 2015 Lutronic LaseMD Pro Fractional Skin Wrinkles
Lutronic LaseMD Ultra Laser is an impressive upgrade to their already successful LaseMD,” shared Steven Weiner, MD, from Lutronic.“Not only is it more powerful (20 watts vs 12 watts) but it also has a significantly lower consumable cost than competitive systems. The LaseMD ULTRA offers a new larger spot size and incorporates improved ‘top hat’ beam profile. The system also offers an incredibly advanced graphical user interface.“The integration of all the new features with real-time information helps reduce treatment time and achieve satisfying patient results in fewer treatments. Since no anesthesia is required, I can treat a full face in about 6-8 minutes or treat the face, neck and chest in 20 minutes.”Lutronic LaseMD Ultra Laser is yet another example of Lutronic’s commitment to Intelligent Design for Intelligent Care, according to the company in a media release. Features include:Highest available power allows for fast treatments, customizable for multiple areas
Gentle, effective global improvement for all skin types, all year-round
Comfortable treatments with very little downtime
Minimal cost of ownership, easy to delegate and no shot limit per procedure“LaseMD ULTRA is my favorite new addition to my practice. It allows me to treat multiple areas quickly, effectively and for very low cost,” adds Joel Cohen, MD, in the release. “My patients love the comfortable treatments and impressive results with minimal downtime.”The LaseMD ULTRA a high-power platform which provides a full range of applications in all skin types, including:Age spots (lentigos),
Sunspots (solar lentigos),
Freckles (ephilides),
Actinic Keratoses, and
Treatment of other benign pigmented lesions.Fractional Skin ResurfacingWrinkles - Laxity - Scar Reduction - Pigmentation - Melasma - Anti-Aging - Actinic Keratosis Excellent, Pre-Owned Condition
Serviced and Fully TestedMfr: Lutronic
Model: LaseMD PRO
S/N: LS115D047PS
Mfr Date: 06-19-2015LaseMDAdvanced skin resurfacing laser featuring the Thulium 1927nm wavelength, which focuses on coagulation rather than ablation.Suitable for all skin types.Cosmeceutical Delivery SystemLaseMD creates micro-channels in the skin to specific depths to delivery topical serums to the correct layer of the skin and increase absorption. It also features a built in centrifuge/incubator for LaseMD serum Ampoules.Optimized Magnetic Sensor Tracking Scanner Includes: 2015 Lutronic LaseMD Pro Fractional Skin Wrinkles
- LaseMD Workstation with Scanning Handpiece
- LaseMD Rolling Cart
- 2 Handpiece Caps
- FootSwitch Pedal
- System Key
- Power CableSpecifications:
Laser Type: Thulium
Wavelength: 1927nm | GE Ultrasound LOGIQ P9
Key Specifications/Special Features:
GE Logiq P9 Review:GE is the largest global ultrasound developer and manufacturer in the world. They design and produce a number of diagnostic ultrasound systems in many global R&D and production sites such as U.S., Japan, Korea, China, and India. The Logiq sereis targets the genral imaging market and has been very successful in the ultrasound market as well as healthcare.
The Logiq P series was created for the economy market, to provide some of the premium features at a lower cost bracket. GE Logiq P7 and P9 are successors of GE Logiq P5 and Logiq P6, two of the best selling GE Logiq systems for last two decades. The GE Logiq P7 and P9 are the latest in the Logiq series, launching in 2016. GE Healthcare shares ultrasound hardware and software with many global production sites so they can keep material cost down and pass the savings to their customers.GE Logiq P9 Ultrasound Features:The LOGIQ P9 is a highly capable ultrasound system that provides excellent image quality and productivity through easy to use tools across a wide range of applications. The LOGIQ P9’s imaging engine delivers crisp images in a mobile, ergonomically designed console. Automation
– 10.4” Touch Panel
– 21.5” Monitor
– Wireless LAN
– CrossXBeam Compound Imaging
– SRIHD Speckle Reduction Imaging
– Coded Harmonic Imaging
– Auto Image Optimization
– Auto IMT
– AutoEF
– Needle Visualization
– B-Flow
– 3D/4D Obstetric Imaging
– Elastography
– Stress Echo
– TVI/TVD Tissue Velocity and Tissue Doppler Imaging
– Virtual Convex for linear and sectoThis ultrasound system from GE Healthcare is a general imaging system designed for quick diagnostic exploration and full schedules.Whether the need is immediate triage or a comprehensive exam, you can rely on the budget friendly LOGIQ P9 system to provide the consistent image quality, comprehensive application coverage, and ease of use that enable clinicians to make timely, confident decisions.- Ergonomic and Adaptable
- Adjust system to fit most user needs and exams
- Multiple USB ports
- Touch control for easy parameter adjustment
- Adjustable monitor
- Front and rear handles
- Four active probe ports
- Gel warmer
- Storage shelf
- Easy to transport
Your trusted companionWhen every patient, every exam and every day are different, you need a constant that will help you gather information, make informed decisions and provide superior patient care. You need GE LOGIQ ultrasound, your trusted companion for confidently navigating daily challenges.
| 2018 Vivace RF Microneedling Radio Frequency Acne ScarsTHE VIVACE EXPERIENCE
The most exciting new technology for aesthetic treatments is the combination of two methods previously used individually for skin rejuvenation, Microneedling and RF Energy. FDA-cleared for your safety, the newest generation, best-in-class Vivace RF Microneedling device, is designed for an incomparable, comfortable experience. Only Vivace boasts a precision robotic motor that brings discomfort to a virtual zero compared to any other device. The results are immediate and improve over time as well, giving you the best of both worlds. Our carefully developed recovery system ensures no one knows you just had a treatment. If you are looking for optimal results, there is no comparison to The Vivace Experience.What is Vivace Fractional RF Microneedling?
The Vivace RF Laser Radio Frequency is the newest generation of microneedling with radio frequency and is effective for fine lines and wrinkles, skin tightening, acne, acne scars, and skin tone, texture and pore size, both on and off the face. It is the most revolutionary contouring and skin tightening system for face, neck, hands and body available, producing immediate, pain-free results.Safe for all skin types, Vivace can offer similar results as ablative and fractional laser procedures, but with significantly less discomfort, downtime, and risk of complications. This revolutionary new treatment also addresses the limitations of older ‘traditional’ RF treatments and heats deeper tissues to a much higher level, which leads to greater collagen production, elastin remodeling and wound contraction previously unattainable with older technology. This is why the Vivace is a game changer in skin rejuvenation and tightening. CLICK HERE to learn moreSlate combines the best device with the newest breakthroughs in numbing, treatment serums and recovery care to create an optimal experience for you that might just keep you from needing other more invasive procedures down the road. The Vivace Experience provides the most dramatic results with less pain and less downtime. The results are both immediate and improve over time with multiple treatments. With results you can see, you’ll look and feel your best at any age.Slate Medspa is the premier Fractional RF Microneedling provider in NJ. We use the most advanced technology to provide a results-oriented skin rejuvenation program. New to Slate Medspa? Call us today at 201-477-5781 to schedule a free consultation and save 20% off your first treatment.How does Vivace Fractional RF Microneedling work?
The Vivace utilizes radio frequency and microneedling to heat the targeted area underneath the epidermis. The Vivace dramatically improves the treatment outcomes compared to other radio frequency microneedling systems.By using insulated needles, Vivace bypasses the epidermis and delivers powerful RF thermal energy to create tens of thousands of fractional coagulation zones in the dermis, facilitating a natural wound healing process. This promotes production of new collagen, remodeling of elastin and wound contraction, enhancing skin laxity. Because the thermal energy is delivered beneath the top layer of skin,Benefits of VIVACE:2018 Vivace RF Microneedling Radio Frequency Acne Scars
Minimizes/Eliminates Fine Lines and Wrinkles
Minimizes/Eliminates Acne Scars & Stretch Marks
Skin Tightening & Texture – Stimulates collagen and elastin production
Treat Sun Damage/Age Spots/Hyperpigmentation
8 Reasons why Slate LOVES Vivace™ RF Microneedling
You’ll see results quickly
Vivace works faster than any other microneedling or laser option. First, the RF Energy creates micro injuries deep in the skin in the form of a matrix. Healthy cells around the newly created matrix promote rapid healing, accelerating collagen production and skin tightening. Secondly, the invisible microchannels in the skin created by the superfine gold-tipped needles remain open for four to six hours allowing maximum absorption the key nutrients and serums applied during the treatment. This would include growth factors, HAs and other cosmeceuticals delivered to the skin in a way that no other treatment can, helping to rapidly rebuild new collagen and elastin.The average patient gets optimal results in just three treatments
Most patients experience noticeably softer, smoother and radiant skin, with improvements in tone, texture and laxity after just one treatment. We can typically achieve optimal results after only three sessions!The treatment is virtually painless
The Vivace Microneedle RF was designed for an incomparable, comfortable patient experience. The unique robotic motor is so precise, it brings the discomfort level to a virtual zero as compared to any other device. The Vivace’s ultra thin needles make it virtually pain-free. A numbing cream is applied before treatment for you to stay comfortable. Our patients here at Slate Medspa consistently report a pain level of “1” on a scale of 1 to 10.There’s no downtime
Vivace’s ultra-thin needles and robotic-assisted mechanism result in an exceptionally precise, even treatment with little-to-no bleeding. In addition, built-in LED Light therapy minimizes post-treatment redness. While we ask patients to wait until the next day before applying makeup, most feel comfortable going out without any makeup.It’s safe for almost any skin type
Patients with darker skin tones can have a more challenging time finding suitable skin resurfacing treatments, as lasers and peels that remove skin layers can risk permanent pigmentation changes. Vivace has 31 Adjustable depths, providing flexibility in treating entire depth or just down deep, bypassing damage to the top layer of skin. This means we can treat a broader array of skin types and tones with absolute precision. In addition, a variable pulse duration means the length of time the needle is engaged with tissue can be precisely controlled based on your skin profile. | 2019 Lumenis Splendor X- Laser Hair Removal
Lumenis Splendor X Laser Hair RemovalThe Alexandrite wavelength at 755 nm, which is ideal for treating skin tones 1, 2 and 3 (fair and light skin tones). It is highly absorbed in melanin and is therefore not safe for use on darker skin tones.
The Nd:YAG wavelength at 1064 nm, which is ideal for treating skin tones 4, 5 and 6 (4 being tanned skin and 5 and 6 darker skin tones) as the absorption by melanin is much lower than with the Alexandrite wavelengthThe Lumenis Splendor X has been introduced to be a player in the solid state Nd:YAG and Alexandrite laser hair removal market. The gold standard for hair removal has always been considered Alexandrite 755nm for light skins and Nd:YAG 1064nm for dark skins.The Lumenis Splendor X combines both in a unique way with blended emission.Instead of firing a single wavelength at a time the Splendor X allows you to fire both wavelengths simultaneous in adjustable amounts to suit the skin type and hair types. This means you are target multiple chromophores at any given time given enhanced results across the board.The Lumenis Splendor X also allows the user to choose between square and round spot sizes with large spot sizesLumenis Splendor X Laser Hair RemovalThe Alexandrite wavelength at 755 nm, which is ideal for treating skin tones 1, 2 and 3 (fair and light skin tones). It is highly absorbed in melanin and is therefore not safe for use on darker skin tones.
The Nd:YAG wavelength at 1064 nm, which is ideal for treating skin tones 4, 5 and 6 (4 being tanned skin and 5 and 6 darker skin tones) as the absorption by melanin is much lower than with the Alexandrite wavelengthLaser Hair Removal
Details:2019 Lumenis Splendor X- Laser Hair Removal- Serial Number: SQEAY-19M-XXXXX (message for serial number)
- System Total Shot Count: 560,693
- Alex Shot Count: 221,437
- YAG Shot Count: 339,256
Includes:- Handpiece and Delivery System
- Square Spot Sizes: 2x2mm, 3x3mm, 5x5mm, 10x10mm, 14x14mm, 18x18mm, 20x20mm, 24x24, 27x27mm
- Fiber Pole
- Foot Switch
- System Key
- Operators Manual
- 30 Day Parts and Labor Warranty
|