| Description | ACTIVE OPTICAL SYSTEMS OPTIMA 518 IPL LASER includes: Handpiece, Footswitch, Operator Eyewear, Patient Eyewear, Cart, Key, Operator Manual, ultrasound gel, replacement fuses, replacement filters | hair removal laser / skin rejuvenation / vascular lesion treatment / onychomycosis treatment | The Philips HD11xe is an extremely popular midrange ultrasound machine that dominated sales in the shared service segment for nearly a decade. The HD11xe balances price and performance perfectly while still giving access to high-end features such as 4D and TEE. The HD11xe had more transducer options than any other midrange and even more than many high-end ultrasound machines. The HD11xe is the replacement for the HD11 and adds an LCD monitor on an articulating arm and software upgrades such as Qlab. The HD11xe is still in high demand after it has gone out of production and offers an amazing value as a refurbished or remanufactured system. the HD11xe was replaced by the Affiniti 50. | 2018 Lutronic Infini RF Microneedling Skin Tightening Laser with RF Microneedling Handpiece - with CONSUMABLE SUPPORT - Free Shipping - | Highest available power allows for fast treatments, customizable for multiple areas
Gentle, effective global improvement for all skin types, all year-round
Comfortable treatments with very little downtime
Minimal cost of ownership, easy to delegate and no shot limit per procedure | 2017 Lumenis M22 with ResurFX & IPL in Like-New Condition; Manufactured 10/22/2017; Based Unit Serial Number 11860, IPL Handpiece Serial Number: 4751; Nd Yag Serial Number: Perfect Cosmetic and Operating Condition, Single Owner; Handpieces Included & Total Pulse Counts: IPL Handpiece Total Pulse Count = 908; ResurFX Handpiece Pulse Count = 16 Pulses; Includes Expert Filters: 515nm, 560nm, 590nm, 615nm, 640nm, 695nm, and 755nm; Also Includes: Footswitch, Interlock, Operator Manual. |
| Content | Active Optical Systems Optima 518 IPL LaserHandpiece (Standard):Multipurpose Wavelength Mark-II
Handpiece (Optional):Facial Treatments
Pulse Interval/Repetition Rate:0.5 – 2 Seconds
Maximum Output Treatment Pattern:22 Joule /cm 2
Output Power:11-31 Joule / cm 2 , up to 4000 W
Cooling System:Improved Air Cooling
Control:Advanced Software Interface
Lamp’s Life Span:200,000 Flashes (minimum)
Treatment Area/Spot Size:15 x 50 mm, (7.5 cm 2)
Wavelength:420 – 1,100 nm
Weight:88.18 lbs (40Kg) (including stand)
Dimensions:17.32 inches x 17.72 inches x 39.37 inches (44cm x 45cm x 100cm)
Mains:220-230 VAC, 50/60 Hz; 100-120 VAC, 50/60 Hz
Max Mains Power:600 VA
Treatments Variety:
Skin Rejuvenation
Pigmentation Treatment
Acne Treatment
Hair Removal
Hair Removal – Deep Follicles
Hair Removal – Sensitive Skin
Vascular (Facial) Treatment
Tattoo Removal
ACTIVE OPTICAL SYSTEMS OPTIMA 518 IPL LASERr uses 12 preset programs. The programs are set in a consecutive, energy intensity increasing order, as specified by the tables of settings, covering all types of hair and skin combinations to be treated.
12 Programs
1 – Very Dark Skin, Fitzpatrick Skin Type IV
2 – Dark Skin, Fitzpatrick Skin Type IV
3 – Dark Skin, Fitzpatrick Skin Type III
4 – Dark Skin, Fitzpatrick Skin Type III
5 – Medium Skin, Fitzpatrick Skin Type II
6 – Medium Skin, Fitzpatrick Skin Type II
7 – Light Skin, Fitzpatrick Skin Type II
8 – Light Skin, Fitzpatrick Skin Type I
9 – Very Light Skin, Fitzpatrick Skin Type I
10 – Very Light Skin, Fitzpatrick Skin Type I
11 – Very Light Skin, Fitzpatrick Skin Type I
12 – High Power, Fitzpatrick Skin Type IActive Optical Systems Optima 518 IPL LaserOptima-518-Classic
The Optima – 518 Classic was designed to answer the needs of sophisticated practitioners who want to provide state of the art treatment to their patients on one hand, based on proven and tested treatment protocols and on the other hand to have the ability to reach new and improved protocols by conducting innovative clinical investigations.The Optima – 518 Classic, based on active’s GEM-PL technology, sets the pulse pattern according to the selected treatment type, skin color, skin photosensitivity and treatment depth. The treatment protocols and different pulse patterns take into account the tissue’s TRT (Thermal Relaxation Time) and the combined knowledge accumulated from thousands of treatments done during the years and clinical investigations done to confirm the findings.ACTIVE OPTICAL SYSTEMS OPTIMA 518 IPL LASERNew Handpiece Design The Optima – 518 Classic is the first model to use the new Mark II which enables a multipurpose handpiece:
* Faster treatments – up to 0.5 Seconds Between pulses.
* Real-time handpiece temperature control.
* Contemporary and stylish design.
* Light weight design – 25% less weight to improve the therapists’ comfort.Research program for clinical investigations, the self setting program allows researchers to set the treatment’s parameters according to their needs. Allowing advanced research with the device. The energy levels in the self setting program can reach 31J cm 2 with high intensity of 4000 W.ACTIVE OPTICAL SYSTEMS OPTIMA 518 IPL LASER Approvals
* CE MDD Intl. Medical Standard
* FDA U.S. Safety Standard
* ISO-13485 Med. Production STD
* IEC 60-601-1 Medical Safety STD
* CFS Gov. Health Approval
* CSA Can. & U.S. Safety App
* TGA Australian health STD. | Duetto Laser Quanta System
The device at a glance
The Duetto MT – EVO Family system is based on Alexandrite and Nd:YAG lasers, 755 nm and 1064 nm, in single or combined emissions. Duetto MT can meet the necessities of every patient by tailoring the treatments in every detail.
Big spot sizes, wide range of pulse widths and fast repetition rate together with the exclusive possibility to set the proportion between Alexandrite and Nd:YAG lasers through the Mixed Technology, make this device one of the most advanced and flexible laser in Aesthetics and Dermatology field especially for the Hair Removal, Vascular and Skin Rejuvenation treatments.
The TWAIN optional handpieces can be installed at any time on the field and can expand the range of applications even more.Mixed Technology
Duetto MT equipped with the second generation of consolidated proprietary Mixed Technology which is able to perform the largest range of hair removal applications, as well as vascular and rejuvenation treatments.
Duetto MT allows the operators to easily select single or double wavelength emissions adapting the treatment to all skin types more precisely.Contact Skin Cooler or Air Skin Cryo
Effective skin cooling is essential forost lasers.
The integrated contact skin cooler of Duetto MT can be used with or without a sapphire window at three different target temperature.
The Skin Cryo handpiece adapter, instead, is intended to work in combination with an external compatible air cooling unit to provide a cold air flow designed for the reduction of pain and thermal injury on wide areas.Duetto Laser Quanta SystemThe TWAIN options are based on IPL or laser handpieces that can also be installed at the clinic’s site any time.
Twain IPL option is based on Intense Pulsed Light technology, it has different optical filters or different handpieces that can have integrated skin cooling (depending on the model and wavelength). It is indicated for:
Hair Removal | Dermatological vascular treatments | Benign pigmented lesions | Skin rejuvenation | Active acne
Twain 2940 is an Er:YAG laser handpiece ideal for skin ablations with confined thermal diffusion for excellent safety scores. It is indicated for:
Normal spots: Skin ablation | Full skin resurfacing
Fractional: Skin resurfacing | Traumatic and acne scars | Epidermal dyschromia | Sun and age spots | Philips HD11XE Ultrasound MachineThe HD-11xe is an excellent shared service machine that balances price and performance perfectly with access to high end features such as 4D and excellent cardiac support. The “xe” version adds an LCD monitor on an articulating arm and software upgrades such as Qlab.PHILIPS HD11 XE ULTRASOUND SYSTEMSOFTWARE VERSION:YEAR OF MFG: 2007INSTALLED OPTIONSQLAB – 2DQ, QLAB – SQ, QLAB – ROI, QLAB – IMTDICOM STRUCTURED REPORTINGDICOM NETWORKINGXRESPANORAMICSONOCTVASCULAROB/GYN GENERAL IMAGINGINCLUDED PROBESC5-2 Convex/AbdomenC8-4v Endo/OBGYNL12-5 Linear/Vascular/Small Parts The Philips HD11xe is an extremely popular midrange ultrasound machine that dominated sales in the shared service segment for nearly a decade. The HD11xe balances price and performance perfectly while still giving access to high-end features such as 4D and TEE. The HD11xe had more transducer options than any other midrange and even more than many high-end ultrasound machines. The HD11xe is the replacement for the HD11 and adds an LCD monitor on an articulating arm and software upgrades such as Qlab. The HD11xe is still in high demand after it has gone out of production and offers an amazing value as a refurbished or remanufactured system. the HD11xe was replaced by the Affiniti 50. Features Fully equipped system supports wide range of facilities This full-featured performer combines broadband beamforming, automated imaging optimization tools, and cutting-edge technologies. The HD11 XE is ideal for public and private hospitals, satellite clinics or specialized practices, and backed by Philip’s award-winning* customer support program. SonoCT and XRES for astounding clarity with images SonoCT imaging technology uses transmit beam-steering techniques to obtain exceptional clear images through compound imaging. XRES adaptive image processing reduces artifacts and enhances margin and border definition for high-quality image. SonoCT and XRES working in tandem display images boosting your diagnostic confidence and allowing you to make patient management decisions quickly. Data management & connectivity enhance efficiency This system supports flexible recording, archiving, and editing, as well as the creation of exam reports with embedded images. On-screen image thumbnails let you build your study and check exam status, at a glance. CD and optional peripheral devices support your documentation and archiving needs. Cardiac & stress echo capabilities extend clinical value The HD11 XE has the versatility to expand into a complete, digital cardiovascular imaging system for further clinical utility and value. You can also add powerful options like QLAB advanced quantification, stress echo, contrast imaging, and transesophageal echo to further enhance your cardiovascular imaging capabilities. | 2018 Lutronic Infini RF Microneedling Skin Tightening System Type: Bipolar RF (Radiofrequency) Frequency: 1 MHz Total RF Treatment Level: Up to Level 20 (Max. Power 50 W) Operation Mode:Microneedle Fractional RF (MFR) Treatment Duration:10 ms – 1,000 ms Tips: MFR Microneedle electrodes, 0.5 – 3.5 mm (Adjustable depth) SFR: Up to 144 pins Display: Color Touch LCD (Total Shot Count Displayed) Dual Switch: Foot & Finger Switch Weight: 28 kg Dimension: 362 mm (W) x 409 mm (L) x 1713 mm (H) Location: Lower Face Submental, Neck, Forehead, Periorbital Pass: Pass1: 2.25 – 3.5 mm, Pass2: 1.5 – 2.25 mm, Pass3: 1.0 – 1.25 mm Intensity: Low, Medium, High MANUFACTURER NOTES: Infini Radiofrequency Microneedling The LUTRONIC INFINI is the ideal solution to create targeted and robust coagulation zones in aging, sagging skin with pigmentation, wrinkles and laxity. Complete control over treatment depth and energy levels enables a multi-layered targeted approach for truly customized treatments, regardless of patients skin type or tanned skin. Now you can provide the best solution for results your patients demand year round. UNIQUE TECHNOLOGY, AMAZING RESULTS Infinis proven & impressive design delivers enhanced wrinkle reduction through 3-dimensional energy delivery to volumize tissue. RF energy delivered via insulated gold-coated microneedles creates precise and controllable fractionated coagulation zones within a specific layer of dermis. Adjustable depth control allows for customized and reproducible treatments of delicate areas. Infini effectively lowers the risk of PIH in dark skin types and can be safely used on patients with melasma and other types of pigmented lesions. Lutronics patented ComfortFlow technology maximizes comfort and patient satisfaction. INFINI is unique technology that puts you in control of your skin rejuvenation procedure. You control the treatment depth and energy levels to enable a multi-layered approach for customized treatments, regardless of skin type or tan. Now you can provide the best solution that will keep your patients returning and referring you to new patients.
IDEAL FOR:2018 Lutronic Infini RF Microneedling Skin Tightening– Acne Scars
– Skin tightening– Wrinkles and fine lines– Active inflammatory acne– Enlarged pores– Scar treatment– Stretch marks– Hyperhidrosis – Over production of sweat– Excessive sebum (face oil) production | 2015 Lutronic LaseMD Pro Fractional Skin Wrinkles
Lutronic LaseMD Ultra Laser is an impressive upgrade to their already successful LaseMD,” shared Steven Weiner, MD, from Lutronic.“Not only is it more powerful (20 watts vs 12 watts) but it also has a significantly lower consumable cost than competitive systems. The LaseMD ULTRA offers a new larger spot size and incorporates improved ‘top hat’ beam profile. The system also offers an incredibly advanced graphical user interface.“The integration of all the new features with real-time information helps reduce treatment time and achieve satisfying patient results in fewer treatments. Since no anesthesia is required, I can treat a full face in about 6-8 minutes or treat the face, neck and chest in 20 minutes.”Lutronic LaseMD Ultra Laser is yet another example of Lutronic’s commitment to Intelligent Design for Intelligent Care, according to the company in a media release. Features include:Highest available power allows for fast treatments, customizable for multiple areas
Gentle, effective global improvement for all skin types, all year-round
Comfortable treatments with very little downtime
Minimal cost of ownership, easy to delegate and no shot limit per procedure“LaseMD ULTRA is my favorite new addition to my practice. It allows me to treat multiple areas quickly, effectively and for very low cost,” adds Joel Cohen, MD, in the release. “My patients love the comfortable treatments and impressive results with minimal downtime.”The LaseMD ULTRA a high-power platform which provides a full range of applications in all skin types, including:Age spots (lentigos),
Sunspots (solar lentigos),
Freckles (ephilides),
Actinic Keratoses, and
Treatment of other benign pigmented lesions.Fractional Skin ResurfacingWrinkles - Laxity - Scar Reduction - Pigmentation - Melasma - Anti-Aging - Actinic Keratosis Excellent, Pre-Owned Condition
Serviced and Fully TestedMfr: Lutronic
Model: LaseMD PRO
S/N: LS115D047PS
Mfr Date: 06-19-2015LaseMDAdvanced skin resurfacing laser featuring the Thulium 1927nm wavelength, which focuses on coagulation rather than ablation.Suitable for all skin types.Cosmeceutical Delivery SystemLaseMD creates micro-channels in the skin to specific depths to delivery topical serums to the correct layer of the skin and increase absorption. It also features a built in centrifuge/incubator for LaseMD serum Ampoules.Optimized Magnetic Sensor Tracking Scanner Includes: 2015 Lutronic LaseMD Pro Fractional Skin Wrinkles
- LaseMD Workstation with Scanning Handpiece
- LaseMD Rolling Cart
- 2 Handpiece Caps
- FootSwitch Pedal
- System Key
- Power CableSpecifications:
Laser Type: Thulium
Wavelength: 1927nm | 2017 Lumenis M22 IPL with ResurFX| Manufacturer Notes |
|---|
| M22 is a modular multi-application platform for the treatment of over 30 skin conditions and hair removal.Available Treatments with M22:– Acne Scar Treatment
– Hair Removal
– Non-Ablative Skin Resurfacing
– Photorejuvenation
– Pigmentation Treatment
– Scar Revision
– Vascular / Leg Vein Treatment
– Dark Tattoo RemovalUsed by physicians around the world, M22 enables you to treat more types of patients and conditions with better outcomes.4 Multiple Technologies In One Modular SystemM22 grows with your practice and can expand to your treatment needs and adapts to future applications as they emerge.Universal IPL
Optimal Pulse Technology (OPT)
Single handpiece with changeable filters and lightguides
For IPL skin treatments using photorejuvenationResurFX
The only True fractional non-ablative, with CoolScan scanner
No disposables
For skin resurfacingMulti-Spot Nd:YAG
The only one with Multiple Sequential Pulsing (MSP)
2 sized lightguides, changeable in seconds
For treatment of leg veins and vascular lesionsQ-Switched Nd:YAG
Homogenous beam profile for enhanced treatment safety and efficacy
For skin toning*, dark tattoos removal, and combination treatments
*Skin toning by treatment of pigmented lesions |
2017 Lumenis M22 IPL with ResurFX and Q-Switched Nd:YAG A modular multi-application system for hair removal and various skin conditions Details:M22 Serial Number: 21171 M22 Date of Manufacture: 2017-07-17 Total IPL Pulses: 19,186 Total ResurFX Pulses: 10,772 Q-Switched Nd:YAG Pulses: 385,505
Includes:IPL Handpiece Complete Standard IPL filters: 515, 560, 590, 615, 640, 695, 755nm, and Calibration Specialty IPL Filters: Acne and Vascular IPL Light Guides: (1)35 x 15 mm2; (1)15 x 8 mm2, (1) 6mm- round ResurFX Handpiece with SapphireCool Tip Q-Switched Nd:YAG Handpiece Foot Switch Power Cord 30 Days Parts and Labor Warranty
|
System specifications
Dimensions:[without ResurFX] 44 x 50.5 x 47 cm (17 x 20 x 18.5 inches)
Dimensions:[with ResurFX] 44 x 50.5 x 61.5 cm (17 X 20 X 24 inches)
Weight:[without ResurFX] 40 kg / 88 lbs
Weight:[with ResurFX] 55 kg / 121 lbs
Electrical requirements:100 240 VAC ±10%, 15A max., 50/60 Hz, single phase, dedicated line M22 is a modular multi-application platform for the treatment of over 30 skin conditions and hair removal. Available Treatments with M22:– Acne Scar Treatment
– Hair Removal
– Non-Ablative Skin Resurfacing
– Photorejuvenation
– Pigmentation Treatment
– Scar Revision
– Vascular / Leg Vein Treatment
– Dark Tattoo RemovalUsed by physicians around the world, M22 enables you to treat more types of patients and conditions with better outcomes.4 Multiple Technologies In One Modular SystemM22 grows with your practice and can expand to your treatment needs and adapts to future applications as they emerge. Universal IPL
Optimal Pulse Technology (OPT)
Single handpiece with changeable filters and lightguides
For IPL skin treatments using photorejuvenation ResurFX
The only True fractional non-ablative, with CoolScan scanner
No disposables
For skin resurfacing Multi-Spot Nd:YAG
The only one with Multiple Sequential Pulsing (MSP)
2 sized lightguides, changeable in seconds
For treatment of leg veins and vascular lesions |