| Description | ACTIVE OPTICAL SYSTEMS OPTIMA 518 IPL LASER includes: Handpiece, Footswitch, Operator Eyewear, Patient Eyewear, Cart, Key, Operator Manual, ultrasound gel, replacement fuses, replacement filters | The M6 therapy laser is a robotized multi-target device designed to treat patients suffering pathologies affecting a wide area, and to perform automatic applications. The distinctive feature of the M6 is the innovative multi-target functioning. Thanks to the features of the exclusive MLS multi-diodic optical group, a wide area is treated instantaneously helping to produce an immediate response of the treated tissues. The results are better and faster than with the scanning modality of traditional laser therapy products. | The Erchonia Zerona Cosmetic Laser model is designed for use during non-invasive body contouring. It is a body sculpting machine designed to remove fat and contour the body without the invasive surgery that many patients prefer not to go under.Zerona is the only clinically-proven non-invasive body contouring treatment, providing 6 quick & painless treatments. These treatments specifically target stubborn fat areas and painlessly emulsify the fat under your skin using the Lymphatic system. | Advanced ergonomic handpiece with multi-spot, quick-zoom cartridges, and large touch screen GUI. | - This Multi-function system offers a wide range of treatments.
- 1046nm long pulsed Nd:Yag treating hair removal, fungal nail and deep thread veins.
- 650nm & 585nm IPL handpieces including for both hair removal, skin rejuvenation, thread veins, pigmentation and more.
- This system can be added to with a 2940 fractional handpiece
- Safety goggles supplied
- Delivery, installation and warranty included.
| 2017 Lumenis M22 with ResurFX & IPL in Like-New Condition; Manufactured 10/22/2017; Based Unit Serial Number 11860, IPL Handpiece Serial Number: 4751; Nd Yag Serial Number: Perfect Cosmetic and Operating Condition, Single Owner; Handpieces Included & Total Pulse Counts: IPL Handpiece Total Pulse Count = 908; ResurFX Handpiece Pulse Count = 16 Pulses; Includes Expert Filters: 515nm, 560nm, 590nm, 615nm, 640nm, 695nm, and 755nm; Also Includes: Footswitch, Interlock, Operator Manual. |
| Content | Active Optical Systems Optima 518 IPL LaserHandpiece (Standard):Multipurpose Wavelength Mark-II
Handpiece (Optional):Facial Treatments
Pulse Interval/Repetition Rate:0.5 – 2 Seconds
Maximum Output Treatment Pattern:22 Joule /cm 2
Output Power:11-31 Joule / cm 2 , up to 4000 W
Cooling System:Improved Air Cooling
Control:Advanced Software Interface
Lamp’s Life Span:200,000 Flashes (minimum)
Treatment Area/Spot Size:15 x 50 mm, (7.5 cm 2)
Wavelength:420 – 1,100 nm
Weight:88.18 lbs (40Kg) (including stand)
Dimensions:17.32 inches x 17.72 inches x 39.37 inches (44cm x 45cm x 100cm)
Mains:220-230 VAC, 50/60 Hz; 100-120 VAC, 50/60 Hz
Max Mains Power:600 VA
Treatments Variety:
Skin Rejuvenation
Pigmentation Treatment
Acne Treatment
Hair Removal
Hair Removal – Deep Follicles
Hair Removal – Sensitive Skin
Vascular (Facial) Treatment
Tattoo Removal
ACTIVE OPTICAL SYSTEMS OPTIMA 518 IPL LASERr uses 12 preset programs. The programs are set in a consecutive, energy intensity increasing order, as specified by the tables of settings, covering all types of hair and skin combinations to be treated.
12 Programs
1 – Very Dark Skin, Fitzpatrick Skin Type IV
2 – Dark Skin, Fitzpatrick Skin Type IV
3 – Dark Skin, Fitzpatrick Skin Type III
4 – Dark Skin, Fitzpatrick Skin Type III
5 – Medium Skin, Fitzpatrick Skin Type II
6 – Medium Skin, Fitzpatrick Skin Type II
7 – Light Skin, Fitzpatrick Skin Type II
8 – Light Skin, Fitzpatrick Skin Type I
9 – Very Light Skin, Fitzpatrick Skin Type I
10 – Very Light Skin, Fitzpatrick Skin Type I
11 – Very Light Skin, Fitzpatrick Skin Type I
12 – High Power, Fitzpatrick Skin Type IActive Optical Systems Optima 518 IPL LaserOptima-518-Classic
The Optima – 518 Classic was designed to answer the needs of sophisticated practitioners who want to provide state of the art treatment to their patients on one hand, based on proven and tested treatment protocols and on the other hand to have the ability to reach new and improved protocols by conducting innovative clinical investigations.The Optima – 518 Classic, based on active’s GEM-PL technology, sets the pulse pattern according to the selected treatment type, skin color, skin photosensitivity and treatment depth. The treatment protocols and different pulse patterns take into account the tissue’s TRT (Thermal Relaxation Time) and the combined knowledge accumulated from thousands of treatments done during the years and clinical investigations done to confirm the findings.ACTIVE OPTICAL SYSTEMS OPTIMA 518 IPL LASERNew Handpiece Design The Optima – 518 Classic is the first model to use the new Mark II which enables a multipurpose handpiece:
* Faster treatments – up to 0.5 Seconds Between pulses.
* Real-time handpiece temperature control.
* Contemporary and stylish design.
* Light weight design – 25% less weight to improve the therapists’ comfort.Research program for clinical investigations, the self setting program allows researchers to set the treatment’s parameters according to their needs. Allowing advanced research with the device. The energy levels in the self setting program can reach 31J cm 2 with high intensity of 4000 W.ACTIVE OPTICAL SYSTEMS OPTIMA 518 IPL LASER Approvals
* CE MDD Intl. Medical Standard
* FDA U.S. Safety Standard
* ISO-13485 Med. Production STD
* IEC 60-601-1 Medical Safety STD
* CFS Gov. Health Approval
* CSA Can. & U.S. Safety App
* TGA Australian health STD. | Cutting Edge MLS M6 Laser Therapy Unit
The M6 therapy laser is a robotized multi-target device designed to treat patients suffering pathologies affecting a wide area, and to perform automatic applications. The distinctive feature of the M6 is the innovative multi-target functioning. Thanks to the features of the exclusive MLS multi-diodic optical group, a wide area is treated instantaneously helping to produce an immediate response of the treated tissues. The results are better and faster than with the scanning modality of traditional laser therapy products.Technical Features
Robotized optical group with 3 MLS sources – power up to 3.3 W
5 cm diameter target area highlighted by high-efficiency red light LEDs
Back-lit graphic touch-screen display
Simultaneous management of two independent channels
MLS pulse modulation frequency from 1 to 2000 Hz with 1 Hz steps
Power level 50% and 100%
Variable or fixed duty cycle
Treatment duration from 1″ to 99’59” with 1″ steps
Automatic calculation of the emitted energy according to the set parameters
Alarms and Safety Features
Laser emission warning light
Interlock (can be temporarily disabled)
Acoustic signal for the beginning and the end of the therapy, and for each treatment second (can be disabled)
Password to operate the device
Language option (Italian, English, German, Spanish)
Dimensions and Weight
27 x 17 x 62 inches; 95 lbsPower Supply
115/230V~ 50/60Hz 150VACUTTING EDGE MLS M6 Laser Therapy UnitTalk to your specialist.
Since 1983 we have been working to be the reference point in Laser Therapy and Magnetotherapy in many areas: from physiotherapy to rehabilitation, from the management of muscle and joint pain to sports medicine. The result of our work allows us today to be recognized as an international leader in the knowledge and development of advanced technologies in the field of “pain management”: a recognition confirmed in 2003 with the entry of the El.En Group. (Star segment of the Italian Stock Exchange – ELN.MI), one of the most important realities in the laser world, both for industrial and medical applications.We have always thought that research is not only confirmation, but also the necessary premise for our work. Born from the synergy between ASAlaser and the Department of Experimental and Clinical Biomedical Sciences of the University of Florence , the ASAcampus laboratory allows us to test the validity of our work and improve results over time. The result of the research is disseminated through conferences, supported thanks to important partnerships and disseminated through numerous scientific publications.Our medical devices for MLS ® Laser Therapy , Hilterapia ® and Magnetotherapy are built according to contents that we consider indispensable: advanced technologies and software, efficacy and safety, ergonomics and design. They allow for ever more targeted and personalized treatment methods. The effectiveness of our therapies is continuously tested thanks to the research carried out in ASAcampus whose results are constantly transferred to clinical applications. | Erchonia Zerona Z6 Laser
The Zerona Laser Can Non-Invasively Reduce Upper Arm CircumferenceThe Zerona laser showed significant effectiveness in treating upper arms in a recent 40 subject, double-blind, randomized sham controlled clinical study. Subjects in the study were strictly screened to only include males and females aged 18 to 65 who were willing to maintain a regular diet and exercise during the time of the study. The study excluded all patients with any confounding medical, surgical, or other problems.All subjects were treated with a total of six, painless 20-minute treatments with either the Zerona 635 nm low-level laser or a sham laser device over a 2 week period. Upon completion of the treatments and at two weeks post-treatment, the active treatment group showed approximately a 4 cm combined reduction in the bilateral circumference and the sham treatment group showed essentially no change. Additionally, in the active treatment group 60 percent of the subjects met the success criteria and experienced a combined arm circumference reduction of 1.25 cm or greater compared with 0 percent of the patients treated with a sham laser. All of the results were highly statistically significant. Both groups showed no change in body mass index (BMI).Using low level laser light, the Zerona laser creates a pore in fat cells and stimulates fat to leak out of the cell. The cell deflates, but is not destroyed, and the fat is naturally processed by the lymphatic system as waste. After six treatments, one every other day for two weeks, patients lose an average of 3.65 inches from their waists, hips and thighs without pain, side effects or downtime.
COLD LASER and LOW LEVEL LASER TREATMENT TECHNOLOGYErchonia Zerona Cosmetic Laser is the first non-invasive fat loss laser to effectively target excess fat without the negative side effects associated with surgical methods. Zerona utilizes the same cold laser technology developed by Erchonia, which has been shown to emulsify fat and allow it to move to the interstitial space.Although this technology was originally utilized to help assist tumescent liposuction procedures, it was found that the cold laser treatment alone helped clients to reduce inches from their waist, hips, thighs, arms, chest, knees, ankles and back or bra fat thus creating overall body slimming effect.The research represented below was done in the US using an Erchonia laser and shows time released photography of one fat cell and its contents being emptied. Please note the cell is still alive. Erchonia uses only its own research to prove its patent and pending applications.
Erchonia Zerona Cosmetic Laser AdvantagesNo pain, no downtime and no risk
Proven effective
Superior treatment area coverageErchonia Zerona Cosmetic Laser Specifications Erchonia Zerona Z6 LaserUnit Status: This Unit is unlocked
Chassis: Power Coated metal frame for ease of cleaning.
Housing: Thermoformed of Non-allergen material / plastic
Accessories: 2 Keys, Laser Safety Glasses
Configuration: 5 – 3b Line Generated Laser Diode Modules
Wavelength: 635 nm
Modulation: Constant Wave (CW) – 1 MHz
Programming: 5 time-saving presets
Display: 8″ Full Color TFT Touch Screen
Electrical Info: 100-240 V (AC), 50-60 Hz
Dimensions: 49″ x 32″ x 57″
Weight: 266 lbs | Lutronic Clarity II
Lutronic’s Clarity II is a high-powered, dual-wavelength platform that effectively delivers a wider range of parameters to help safely and efficiently treat the broadest indications with ease. The innovative design includes: a single fiber for all spot sizes(2-25mm), intuitive interface, and no need for calibration after any parameter change. Clarity II can save time and help facilitate faster, more effective treatments.
Higher power 755/1064nm platform for effective treatments up to 45%* faster.
Brilliantly removes hair, pigment, and vascular lesions in all skin types.
IntelliTrak technology and Temperature Sensing enable increased provider confidence and treatment efficacy.Clarity II
Key Feature
1. Powerful and faster
Provide up to 25mm spot size at a useable >2 Hz
High power performance
Up to 45% faster
2. Intelligent and convenientIntelliTraking system to prevent skip area and consistent treatment
Real time skin temperature monitoring system
3. Designed for versatilityIntelligent memory function to keep track of past treatment history in detail
Zoom cartridge system for treatment areaLutronic Clarity IIHow It Works
The CLARITY II Laser System contains two separate laser resonators, Alexandrite and an Nd:YAG, which generate pulse laser energy at the nominal wavelength of 755nm and 1064nm respectively. The output of each laser generator and the 515nm aiming beam are optically combined on the laser rail so that their beam paths are identical as they exit the laser system. This allows the use of a single delivery system for either the 755nm or 1064nm wavelength.Clarity II
with IntelliTrak technologyHigher-powered 755/1064nm platform laser
Up to 2X faster Laser Hair Removal Txs*
Exclusive shorter pulsewidths available including 1ms setting
for finer facial hairs
Breakthrough intelligent capabilities
IntelliTrak technology for faster more consistent Tx coverage
Temperature Sensing for real-time skin temp feedback
during Tx
Auto-calibration in seconds saves time and
improves productivity
Advanced, easy-to-use platform
Single fiber for all 2-24mm spot cartridges
Numerous skin rejuvenation capabilities including vascular,
pigment, and toning Txs
*At settings of: 755nm, 5ms, 12J/cm2: Clarity II at 22mm, 3Hz, IntelliTrak at 18% overlap vs.
older system at 18mm, 2Hz, and est. ~18% manual overlap. Geometric treatment coverage speed is
11.4cm/second with Clarity II vs. 5.1cm/second with older system. | Lynton Lumina IPL HR Laser
2013 Lynton Lumina IPL HR Laser Hair Removal 650nm 585nm 1064 YAG Beauty MachineIn very good condition and full working order
Purchase new in December 2013, so less than a year old
Laser has minimal use total count of 29427 from newPlease click HERE for further information
Included:-
1 x 2013 Lynton Lumina IPL YAG Laser Hair Removal Beauty Machine
1 x Lynton 650 IPL Handpiece in protective storage box – Total Handpiece Shots 21600
1 x Lynton 585 Plus IPL Vascular Handpiece in protective storage box – Total Handpiece Shots 385
1 x Lynton 1064 YAG Laser Vascular Handpiece with 3mm, 6mm, 8mm tips in protective storage box – Total Handpiece Shots 7442
1 x Set of 3 IPL light guides in protective storage boxFor the following treatments
650nm Hair removal
650nm C.F.TMachine can do the following
585nm Vascular Plus
585nm Pigmentation Plus
585nm Photorejuvenation Plus
585nm Acne Plus
The ultimate ‘build as you grow’ laser & IPL machine, offering practitioners the opportunity to dramatically increase and extend their treatment portfolio, without having to purchase numerous devices. British manufactured and listed on the NHS Supply Chain, the LUMINA offers the UK’s most in-demand treatments; hair removal, tattoo removal, anti-ageing and skin resurfacing.Highly versatile, and with numerous revenue capabilities, the Lumina delivers fast and clinically effective treatment results with superior efficacy. As the best-selling multi-function aesthetic machine, the LUMINA has a proven track record of building, growing and establishing clinics as the No.1 in their area.As our flagship machine, and the product of over 20 years expertise in the design, development and manufacture of laser/IPL systems, the LUMINA is specifically designed to be adaptable to address emerging applications. As well as unrivalled laser technology, the LUMINA has a built-in patient database and parameter printer, and benefits from its easy-to-use touchscreen. 1. Intense Pulsed Light (IPL): the perfect combination of hair removal and skin rejuvenation treatments come as standard with the LUMINA system via its 585 & 650 handpieces.Hand-piece
Type Wavelength(s) Maximum
Fluence Treatments Spot Sizes Maximum
rep. rate
585 Intense
Pulsed Light 550 – 1100nm 50J/cm2 Superficial Vascular
Superficial Pigmentation
Active Acne
Skin-rejuvenation 1x1cm
2.5x1cm
5x1cm
1cm circular 1Hz
650 Intense
Pulsed Light 625 – 1100nm 40J/cm2 Hair removal (1 to 5)
Collagen treatment 1x1cm
2.5x1cm
5x1cm
1cm circular 1Hz
650 Advance IPL hand-piece, which has been designed to provide faster results in hair removal of finer, lighter hairs found on the face and navel. The 650 Advance hand-piece has software optimised for the greater power it delivers, allowing experienced practitioners to treat finer and fairer hairs successfully, in skin type 1 to 3 clients in a single or dual pulse mode. | 2017 Lumenis M22 IPL with ResurFX| Manufacturer Notes |
|---|
| M22 is a modular multi-application platform for the treatment of over 30 skin conditions and hair removal.Available Treatments with M22:– Acne Scar Treatment
– Hair Removal
– Non-Ablative Skin Resurfacing
– Photorejuvenation
– Pigmentation Treatment
– Scar Revision
– Vascular / Leg Vein Treatment
– Dark Tattoo RemovalUsed by physicians around the world, M22 enables you to treat more types of patients and conditions with better outcomes.4 Multiple Technologies In One Modular SystemM22 grows with your practice and can expand to your treatment needs and adapts to future applications as they emerge.Universal IPL
Optimal Pulse Technology (OPT)
Single handpiece with changeable filters and lightguides
For IPL skin treatments using photorejuvenationResurFX
The only True fractional non-ablative, with CoolScan scanner
No disposables
For skin resurfacingMulti-Spot Nd:YAG
The only one with Multiple Sequential Pulsing (MSP)
2 sized lightguides, changeable in seconds
For treatment of leg veins and vascular lesionsQ-Switched Nd:YAG
Homogenous beam profile for enhanced treatment safety and efficacy
For skin toning*, dark tattoos removal, and combination treatments
*Skin toning by treatment of pigmented lesions |
2017 Lumenis M22 IPL with ResurFX and Q-Switched Nd:YAG A modular multi-application system for hair removal and various skin conditions Details:M22 Serial Number: 21171 M22 Date of Manufacture: 2017-07-17 Total IPL Pulses: 19,186 Total ResurFX Pulses: 10,772 Q-Switched Nd:YAG Pulses: 385,505
Includes:IPL Handpiece Complete Standard IPL filters: 515, 560, 590, 615, 640, 695, 755nm, and Calibration Specialty IPL Filters: Acne and Vascular IPL Light Guides: (1)35 x 15 mm2; (1)15 x 8 mm2, (1) 6mm- round ResurFX Handpiece with SapphireCool Tip Q-Switched Nd:YAG Handpiece Foot Switch Power Cord 30 Days Parts and Labor Warranty
|
System specifications
Dimensions:[without ResurFX] 44 x 50.5 x 47 cm (17 x 20 x 18.5 inches)
Dimensions:[with ResurFX] 44 x 50.5 x 61.5 cm (17 X 20 X 24 inches)
Weight:[without ResurFX] 40 kg / 88 lbs
Weight:[with ResurFX] 55 kg / 121 lbs
Electrical requirements:100 240 VAC ±10%, 15A max., 50/60 Hz, single phase, dedicated line M22 is a modular multi-application platform for the treatment of over 30 skin conditions and hair removal. Available Treatments with M22:– Acne Scar Treatment
– Hair Removal
– Non-Ablative Skin Resurfacing
– Photorejuvenation
– Pigmentation Treatment
– Scar Revision
– Vascular / Leg Vein Treatment
– Dark Tattoo RemovalUsed by physicians around the world, M22 enables you to treat more types of patients and conditions with better outcomes.4 Multiple Technologies In One Modular SystemM22 grows with your practice and can expand to your treatment needs and adapts to future applications as they emerge. Universal IPL
Optimal Pulse Technology (OPT)
Single handpiece with changeable filters and lightguides
For IPL skin treatments using photorejuvenation ResurFX
The only True fractional non-ablative, with CoolScan scanner
No disposables
For skin resurfacing Multi-Spot Nd:YAG
The only one with Multiple Sequential Pulsing (MSP)
2 sized lightguides, changeable in seconds
For treatment of leg veins and vascular lesions |
Reviews
There are no reviews yet.