| Description | Retinomax Series, the world’s leading handheld Ref and Refract Keratometer, delivers wide measurement range on par with table type Ref, now boasts greater mobility, stability and accuracy.Current informatical society, eye fatigue, one of the typical modern diseases cause by eye accommodation issue is now easily discover by ACOMOREF2 series during screening basis. Accommodative Micro Fluctuation result will show in graph for easy reading, plus opacity detection function makes ACOMOREF2 the world first All-in-one Refractometer. | Laser-Like Precision
- Tactile control with minimal tissue drag
- Surface only thermal effect
- Predictable, char-free layer-by-layer dissection with optimal visualization of tissue planes
- Safe to use near nerves, vessels, and all delicate organs, including the heart | The Easyfield perimeter is operated via an external computer (notebook or PC). You can enjoy the full freedom of networking the examination data with the familiar user interface of the OCULUS programs. The use of translucent eye shields allows you to conduct measurements without the usual eye patch, thus saving you valuable time of preparing examinations. | The Canon RK-F2 Fully Automatic Refractor-Keratometer helps accelerate the exam process by automatically aligning and acquiring a reading for one eye and continuing to the opposite eye to perform the same function – all with one touch of a button. | The Huvitz Excelon CPE-4000 Edger is a versatile lens finishing system designed for retail practices. All of the finishing processes—from tracing to edging—are fully optimized with advanced three-dimensional digital technology, enhancing productivity and efficiency.
Beveling, polishing, grooving and safety beveling are completely integrated and easily performed by a touch of a button. In addition, built-in the CPE-4000 features digital pattern layout that allows users to modify shape width, height, and circumference to better manage the fitting challenges posed by rimless and semi-rimless frames. | The Retinomax Series, the world’s leading handheld autorefractor and autorefractor/keratometer, delivers wide measurement range on par with table type refr, now boasts greater mobility, stability and accuracy. The Retinomax series is widely used as a global standard device for pediatric, screening, medical care in remote areas, disaster area and wide range of ophthalmic scene. Also known as: Retinomax K+, KPlus5 |
| Content | Righton BON ACOMOREF 2 K-Model Autoref-Keratometer3 in 1 Function
With combination of Refractometer (Keratometer), Accommodative Micro Fluctuation, Opaque Media (opacity) screening. For even more information view lightning link casino. Reduce of accommodation testing time
Accommodation measurement speed is remarkably improved that can be tested in 49 seconds per eye in SCR (screening) mode. Objectively find the cause of eye fatigue
Patient’s individual AMF (Accommodative Micro Fluctuation) value will be analyzed and from the data, High Frequency Components (1 – 2.3Hz) will be extracted and based on measurement data, chart location, accommodation reaction value and pupil size to formulate FK map (Frequency of Kinetic reaction). ADD Function Righton BON ACOMOREF 2 K-Model Autoref-Keratometer
The ADD function enable a patient’s near point power to be measured objectively by applying accommodative stimulation. And auto AMF can detects if the power gives the patient eye strain or not by color indication. Residual Astigmatism Calculation (Only for K-model)
Residual astigmatism calculation, necessary for CYL contact lenses and CYL IOL prescriptions, is automatically conducted and results printed out (K-Model). Astigmatism corresponding meridian target
Retinomax Series, the world’s leading handheld Ref and Refract Keratometer, delivers wide measurement range on par with table type Ref, now boasts greater mobility, stability and accuracy.Current informatical society, eye fatigue, one of the typical modern diseases cause by eye accommodation issue is now easily discover by ACOMOREF2 series during screening basis. Accommodative Micro Fluctuation result will show in graph for easy reading, plus opacity detection function makes ACOMOREF2 the world first All-in-one Refractometer. | Domain Surgical FMX and FMwand Ferromagnetic Surgical SystemThe FMX Generator intelligently delivers electrical energy to the surgical instruments. The advanced generator features a patented software control algorithm that continuously monitors and adjusts the delivery of energy, ensuring that the optimal amount of heat is delivered to the tissue at all times. The large touchscreen display provides the entire surgical team immediate feedback on power setting levels and changing settings is as easy as touching the display. The FMX Generator has earned the Type CF (“Cardiac Floating”) rating.Laser-Like Precision
- Tactile control with minimal tissue drag
- Surface only thermal effect
- Predictable, char-free layer-by-layer dissection with optimal visualization of tissue planes
- Safe to use near nerves, vessels, and all delicate organs, including the heartMinimal Thermal Injury
- As little as 1/10th the thermal injury of monopolar electrosurgery
- As few as 80 microns (0.08 mm) of thermal spread
- Clear margins for reliable pathology specimens
- Surgeons note less unintended damage to tissue, leading to reduced use of blood products during surgery, and less post-operative edema and drainageElectrical Silence
- No electrical current passes through tissue
- No grounding pad
- No spark, arcing, or stray currentPrepare the FMwand by following these simple steps:
- Plug the FMX Power Module into the front panel of the FMX Generator
- Snap the power module into the back of the FMwand Handpiece
- Set the power settings on the generator and the FMwand is readyFMX Generator Technical Specifications Domain Surgical FMX and FMwand Ferromagnetic
- Operating Environment Conditions
Temp: 10° to 30° C (50° to 86° F)
Humidity: 15% to 85% Non-condensing
- Storage Conditions
Temp: -20° to 65° C (-4° to 149° F)
Humidity: 15% to 85% Non-condensing
- Shipping Conditions
Temp: -20° to 65° C (-4° to 149° F)
Humidity: 15% to 85% Non-condensing
- Moisture Protection
Generator: IPX1
Foot Pedal: IPX7 minimum
- Generator Dimensions : 14″ x 4″ x 12″ 35.6 cm x 10.2 cm x 30.5 cm
- Generator Weight : Approximately 20 lbs. (9 kg)
- Power Requirements
Voltage: 110/220/230 Vac
Current: 4/2A rms max
Frequency: 50/60 Hz
- Power Output : 60W Max
- Fuses
For 110V: T 5A L 250V
For 220V/230V: T 2.5A L 250V
- Operating Frequency : 40.68 MHz
- Mode of Operation : Intermittent Operation 10 sec. ON, 30 sec. OFF
- Protection Class : Class I
- Output Type : Type CF | Oculus Easyfield Visual Field Analyzer Perimeter
KEY FEATURES
– Full-fledged compact perimeter capable of performing standard automated perimetry of the central visual field up to 30° eccentricity– Designed for the combined use as visual field screener and perimeter, offering features usually available only in large units– Spherical bowl with 30 cm (11.81â) radius is enclosed into an ergonomically movable cone equipped with a distance adapted lens– Conforms to the Goldmann standard and fulfills the ISO-12866 norm for perimeters– Measurements of the Easyfield are carried out using an LED grid with 135 fixed test locations, including the common 30-2, 24-2 and 10-2 patterns– Novel SPARK test strategy leads to faster and more stable threshold tests providing improved diagnostic capabilities– Besides the standard field indices the Easyfield delivers evaluations of the innovative Glaucoma Staging Program (GSP) and the classifications provided by the Glaucoma Staging SystemADVANTAGES Oculus Easyfield Visual Field Analyzer Perimeter
– Fast: Shorter examination times even for threshold tests– Compact: No completely dark room required thanks to the closed construction– Lightweight: Minimal footprint and maximal transportability– Full Threshold: The classical 4-2 dB staircase strategy using two reversals in the patients answer to deliver a threshold value– Fast Threshold: Bracketing strategy using variable steps and taking advantage of already measured locations– CLIP: Strategy using stimuli with continuously increasing luminance– Threshold value is assigned the moment the stimulus is perceived– SPARK: Fast and averaged threshold strategy based on statistical correlations between threshold values measured in different locationsThe Oculus Easyfield is a compact visual field that is packed with options with a very small footprint. This system is ideal for tight spaces or a smaller practice. Easy to use and very user friendly. The Oculus Easyfield is an exciting compact perimeter that performs static perimetry up to 30°. It has been designed as a visual field screener and perimeter, offering features usually available only in large units. The Easyfield’s integrated bowl with a 11.81” (30 cm) radius and distance corrected lens is adapted to the Goldmann standard and fulfills the ISO-norm 12866 for perimeters. The Easyfield has a fixed point grid with 135 test locations including 30-2. | ZEISS Cirrus HD OCT 4000 Quad Core OCT- 3D Auto-Alignment
- Auto-Focus
- Auto-Shooting Retro-Illumination
- 10 Ref/Kera measurement data memory for each eye
- Small pupil size
- Corneal periphery measurement
- Wide diopter measurement range (-33D through +22D)
- Integrated thermal printer
- Motorized joystick control
- Motorized chin rest
SMALL PUPIL SIZE
At 2.0 mm, the small pupil mode helps contribute to an efficient screening and is useful when a patient’s pupils are difficult to dilate. The short reaching distance between the patient and operator allows closer personal interaction and easy access to the patient’s eyes.RETRO-ILLUMINATION
Using infrared retro-illumination, the RK-F2 Ref-Keratometer provides a detailed view of the eye which is helpful for identifying cataracts, vitreous opacity, scars, and other serious eye problems.CORNEAL PERIPHERY MEASUREMENT
The peripheral keratometry mode provides accurate measurements for examining oblique astigmatisms and helps determine the best fit for a contact lens. The RK-F2 Ref-Keratometer can be used to make a series of measurements at a 30 degree angle from the eye’s center along the attentive meridians. WIDE MEASUREMENT RANGE The dioptric measurement range of -30D to +22D allows examination of strong myopia or hyperopia. The astigmatic measurement range extends from 0 to 10D. The radius of curvature extends from 5 to 10 mm (33.75D to 67.5D) for keratometry.IMAGE ERROR DETECTION
Advanced software automatically confirms both the correct alignment and focus.COMPACT AND LIGHTWEIGHT
The RK-F2 Ref-Keratometer is compact and designed to be operated either sitting or standing, whichever is more comfortable for the operator. Weighing a little more than 33 pounds, the lightweight RK-F2 Ref-Keratometer maximizes small work areas and comfortably fits on a Canon instrument table (sold separately) with a Canon Full Auto Tonometer or Canon Non-Mydriatic Retinal Camera (both sold separately). Keeping the Canon machines next to one another can help expedite the exam process.MULTI-FUNCTIONAL COLOR LCD MONITOR
The 5.7 inch color LCD monitor tilts 40° making the RK-F2 Ref-Keratometer easy to use if the operator is sitting or standing. The clear LCD display also includes multi-functional screen buttons allowing the operator to switch menus as needed.MOTORIZED OMNI-DIRECTIONAL JOYSTICK
Aligning the patient’s eye is easy using the motorized omni-directional joystick with a fine focus dial. All positioning may be performed with one hand allowing the other hand to work with the patient, if needed. The top of the joystick button has the start button which can immediately be pressed once the patient is properly positioned.BUILT-IN PRINTER ZEISS Cirrus HD OCT 4000 Quad Core OCT
The front-loaded, high speed built-in printer includes an auto cutter making it simple to remove the print-out. The ECO setting reduces the printing density and thereby conserves the paper necessary for printing by up to 50% as compared to printing without using the ECO setting. | HUVITZ CPE 4000 3D Edger Patternless EdgerFeatures of the CPE-4000 Patternless Edger| ▪ Digital Pattern Layout
▪ Frame Comparison
▪ Advanced Digital Technology
▪ Four Grinding Wheels
▪ 3D Lens Measurement
▪ Ultra-Fine Bevel Adjustment | ▪ Automatic Polishing
▪ Safety Bevel
▪ Adjustable Precision Grooving
▪ Convenient User Interface
▪ More Efficient
▪ Silent Operation |
| |  | | Digital Pattern Layout
The Digital Pattern Layout function allows users to modify lens width, height, and circumference and manage the fitting challenges posed by rimless and semi-rimless frames. You can can choose between optical and geometric centered layouts. Layouts for far vision and near vision in bifocal lens mode are provided. The horizontal PD can be easily adjusted and multiple input methods for setting the height of multifocal progressive lenses are available. | | HUVITZ CPE 4000 3D Edger Patternless Edger | | Frame Comparison
When replacing frames the sizes of the old and new frames can be conveniently compared on screen. Advanced Digital Technology
Advanced 3-Dimensional digital technology substantially reduces the overall cycle time.Four Grinding Wheels
The CPE-4000 edger features four grinding wheels, enabling you to work with all lens materials including glass, plastic, hi-index, polycarbonate, and Trivex. | |  | | 3D Lens Measurement
The CPE-4000 features an advanced lens sensor that will allow you to achieve a 3-dimensional measurement to optimize both beveling and grooving. | |  | | Ultra-Fine Bevel Adjustment
With the CPE-4000, bevel position can be precisely adjusted in fine 0.01mm increments relative to the front curve, back curve, thickness, or base curve of the lens. | | | Automatic Polishing
Enjoy superior, automatic polishing of beveled, grooved, and flat-edged lenses. | |  | | Safety Bevel
The CPE-4000 can achieve front and rear safety beveling, making it a leader in its class. | | | Adjustable Precision Grooving
This model features incredibly fine, adjustable precision grooving. The position, width and depth of the groove can be adjusted in 0.01mm increments. | |  | | Convenient User Interface
A graphic user interface makes it easy for virtually any operator to manage all of the process functions and custom settings. | | | More Efficient
Numeric keypad permits rapid data entry. With the CPE-4000, you can manage multiple jobs simultaneously for improved efficiency. Silent Operation
A built-in inverter mechanism minimizes noise during the edging process, ensuring a comfortable work environment. |
| Edging System | Automatic | | | | Edging Mode | Beveling
Flat Edging
Grooving
Safety Beveling
Polishing | | | | Lens | Glass, Plastic, High Index Plastic, Poly Carbonate, Trivex | | | | Edging Size | Max: 3.54in / 90mm
Min: 0.71in / 18mm | | | | Weight | 99lb / 45kg | | | | Power Supply | AC 110/220V, 50/60Hz | | | | Power Consumption | 1200W (Max) | | | | Dimension | 22.44(W) X 21.26(D) X 18.11(H)in (570(W) X 540(D) X 460(H)mm) | | | | Others | High Brightness Wide TFT LCD Adopted
Bar Code System Available
Networking System | | | | Tracer | | | | Dimension | 11.02(W) X 11.81(D) X 9.05(H)mm (280(W) X 300(D) X 230(H)mm) | | | | Tracing System | 3D Binocular | | | | Weight | 17.6lb / 8kg | | | | Power Supply | AC 110/220V, 50 / 60Hz | | | | Power Consumption | 42W (Max) | | | | Others | User friendly display with LCD |
| Righton BON Retinomax K-Plus 5 (Autoref Keratometer)Retinomax Series, the world’s leading handheld Ref and Refract Keratometer, delivers wide measurement range on par with table type Ref, with greater mobility, stability and accuracy.The Retinomax series is widely used as a global standard device for pediatric, screening, medical care in remote areas, disaster area and wide range of ophthalmic scene.Current informatical society, eye fatigue, one of the typical modern diseases cause by eye accommodation issue is now easily discover by ACOMOREF2 series during screening basis. Accommodative Micro Fluctuation result will show in graph for easy reading, plus opacity detection function makes ACOMOREF2 the world first multi-functional Refractometer.Features:Righton BON Retinomax K-Plus 5 (Autoref Keratometer)View Finder – With view finder observation, no limit of operator age. Diopter adjustable range is +/-8D the same as Retinomax3. View finder arm angle is changeable of 0-135 degrees, making measurement easy regardless of patient’s position or posture. Adjustable diopter +/- 8D.Wider Eye Piece – Eye piece relief is 48mm from 32.2mm so that enable to look inside image while even looking at outside. No need to stick eye to the eyepiece all the time.Improved battery life – At 180 minutes, the battery capacity is now twice that of conventional modelsAutomatic Axis Compensation and Extended Measurement Range – Not only does the device let examiner know the cylinder axis angle, but it can also be automatically adjusted if it is not levelNew Child Mode – While the measurement is being taken, a melody plays continually to keep children’s attention. A constantly changing color display, both on the outside and inside target the device, also keeps children involved during the process.Even lighter and featuring an easy-to-hold gripRetinomax3 969g → Retinomax Screeen 960g -9gRetinomax K-plus3 999g → Retinomax K+Screeen 970g -29gREFRetinomax 5, Retinomax K+ Screeen −20D〜+23D |
Reviews