| Description | Embedded tracking system with a built-in, high-definition video camera
Fly mode for faster treatment time and higher profitability
Comprehensive contouring with a single transducer that precisely focuses ultrasound energy to treat large and small areas
DESIGN | Bison Dual ACCENTO is the unique device combination with Alexandrite laser (755nm) and Nd:YAG laser (1064nm Long pulse)
The combination of two different wavelengths makes DUAL ACCENTO a highly effective system for hair removal and pigmented lesions treatment. The 755nm penetrates deep into the skin and perfectly targets hair the follicle and absorbs melanin. | Energist NeoGen PSR offers a range of treatment options, and delivers the unparalleled results your patients expect: The unique energy delivered by NeoGen is non fractionated and not dependant on a chromophore for its uptake. This provides uniform energy absorption, ensuring consistent treatment of the skin, and at high energies supporting significant tightening. | The ability to work specifically in the deep dermis, without damaging the epidermis, is regulated in the RF Secret by the delay time of fractional radiofrequency. The needles are inserted at a rate of milliseconds equal to a stamping process in the skin and also withdrawn immediately. Only after the needles are penetrated into the desired skin layer, is carried out for a few milliseconds, a radio frequency pulse to set heat damage. While the penetration into the skin, the needles remain always cold. In order to achieve a deep and superficial effect, the needle depths can be varied individually in the respective treatment passes. | Treatments offered with the InMode OptimasMorpheus8- Skin Resurfacing and RejuvenationLumecca IPL – Age spot and sun spot treatmentForma – Skin remodeling at its bestAvailable Handpieces:
LUMECCA
FORMA
FRACTORA
DIOLAZEXL
VASCULAZE
VLAZE
MORPHEUS8LUMECCA
Fastest IPL Results*
*Clearance in 1-2 sessions, compared to 4-5 sessions with competing devices | Superior, Comfortable Laser Hair RemovalLaser Hair Removal – An In-demand Procedureexcel HR combines a high-power 755 nm Alexandrite laser and Cutera’s proven long-pulse 1064 nm Nd:YAG laser for safe, effective high-volume hair removal on all skin types. The combination of wavelengths not only allows for effective hair removal, but is also a solution for epidermal pigmented lesions, vascular lesions and Cutera’s signature laser genesis skin revitalization procedure. |
| Content | Syneron Candela Ultrashape-UltraShape Power
SYNERON CANDELA UltraShape POWER NON-THERMAL ULTRASOUND SYSTEMUltraShape Power is FDA-cleared for non-invasive reduction in abdominal circumference and fat reduction in the abdomen, flanks, and thighs.1,2It gently destroys fat by delivering non-thermal ultrasound energy waves that are:Focused – delivering ultrasound energy to tissue within a precise focal volume at a controlled depth
Pulsed – the mechanical non-thermal effect results in minimal elevation of 0.8°C in treated tissue for a truly comfortable and gentle treatment experience
Selective – precisely targeting fat cells while blood vessels, nerves, and surrounding tissue remain largely unaffectedSYSTEM Syneron Candela Ultrashape-UltraShape PowerEnd-to-end patient and therapy management solution offers sophisticated, easy-to-use analysis and reporting tools
Built-in HD touchscreen provides ultra-clear visibility and touch control during treatment
Fully Wi-Fi enabled for remote diagnostics, software updates, support, and purchasing consumablesCAPABILITIESEmbedded tracking system with a built-in, high-definition video camera
Fly mode for faster treatment time and higher profitability
Comprehensive contouring with a single transducer that precisely focuses ultrasound energy to treat large and small areasDESIGNLightweight, compact design for easy transport between treatment rooms (the entire system weighs just 45 kg/99 lbs.)
Light hand piece designed to provide precise control while reducing operator fatigue
SYNERON CANDELA UltraShape POWER NON-THERMAL ULTRASOUND SYSTEMUltraShape Power is FDA-cleared for non-invasive reduction in abdominal circumference and fat reduction in the abdomen, flanks, and thighs.1,2It gently destroys fat by delivering non-thermal ultrasound energy waves that are:
Focused – delivering ultrasound energy to tissue within a precise focal volume at a controlled depth
Pulsed – the mechanical non-thermal effect results in minimal elevation of 0.8°C in treated tissue for a truly comfortable and gentle treatment experience
Selective – precisely targeting fat cells while blood vessels, nerves, and surrounding tissue remain largely unaffectedSYSTEM
End-to-end patient and therapy management solution offers sophisticated, easy-to-use analysis and reporting tools
Built-in HD touchscreen provides ultra-clear visibility and touch control during treatment
Fully Wi-Fi enabled for remote diagnostics, software updates, support, and purchasing consumablesCAPABILITIES
Embedded tracking system with a built-in, high-definition video camera
Fly mode for faster treatment time and higher profitability
Comprehensive contouring with a single transducer that precisely focuses ultrasound energy to treat large and small areasDESIGN
Lightweight, compact design for easy transport between treatment rooms (the entire system weighs just 45 kg/99 lbs.)
Light hand piece designed to provide precise control while reducing operator fatigue | Bison Dual ACCENTO Nd YAG Laser
Bison Dual ACCENTOBison Dual ACCENTO is the unique device combination with Alexandrite laser (755nm) and Nd:YAG laser (1064nm Long pulse)
The combination of two different wavelengths makes DUAL ACCENTO a highly effective system for hair removal and pigmented lesions treatment. The 755nm penetrates deep into the skin and perfectly targets hair the follicle and absorbs melanin.The Dual Accento combined laser system is indicated for the following: 755 nm Long Pulsed Alexandrite Laser Temporary hair reduction. Stable long-term or permanent reduction through targeting of melanin in hair follicles. Treatment of bening pigmented lesions. Treatment of Wrinkles.The photocoagulation of dermatological vascular lesions (such as port of wine stains, hemangiomas, telangiectasis) 1064nm Long pulsed Nd:YAG laser. The removal of un-wanted hair reduction, for stable long term or permanent hair reduction and for treatment of PFB to all skin types Fitzpatrick I-VI including tanned skin.Pigmented lesions to reduce lesion size and patients with lesions. Reduction of red pigmentation in hypertrophic and keloid scars where vascularity is integral part of scar, treatment of wrinkle. Permanent hair reduction is defined as the long term, stable reduction in the number of hairs re- growing when measured at 6,9, and 12 months after the completion of treatment regime.The Dual Accento performs with high efficacy of the pigmentation problems without damaging tissue structures adjacent to the pigment. The wavelength of 1064nm Nd: YAG long pulse rejuvenates the skin by stimulating the collagen layer of the dermis and effectively treats vascular lesions and is appropriate for all skin types when used for hair removal.Bison Dual ACCENTO 1064nm NdYAG Laser With 755nm Alexandrite Laser
Bison Dual ACCENTO 1064nm NdYAG Laser with 755nm Alexandrite Laser is the unique device. Combining 755nm Long pulsed Alexandrite and 1064nm Long pulsed NdYAG Alexandrite 755nm long pulsed wavelength. Due to the high melanin absorption is effective for hair removal and pigmented lesions treatment. NdYAG 1064nm long pulsed wavelength rejuvenates skin by stimulating the dermis layer, effectively treating vascular lesions. | Energist NeoGen PSR LaserNeoGen PSR SystemNeoGen nitrogen plasma technology delivers controlled heating to the skin architecture stimulating a significant physiological response, without creating an open wound. Unlike ablative technologies there is no epidermal vaporisation or charring caused at time of treatment.
Unique TechnologyNeoGen converts nitrogen gas into plasma energy, the fourth state of matter. The plasma emerges from the handpiece in controlled pulses and rapid heating of tissue occurs as it gives up its unique thermal energy to tissue.
No Open WoundsThe treated photodamaged layers undergo a controlled thermal modification, while remaining intact, creating a natural dressing to provide protection and speed healing. at high energies the epidermis sheds, but only after a new, healthier skin architecture is formed beneath.
Treats the Whole Skin ArchitectureTreating the entire skin structure ensures optimal results as the entire surface is regenerated with associated neocollagenesis and neoelastogenesis. No islands of untreated skin remain. Clinical studies show significant tightening – Mean 22% improvement in upper eyelid tightening (JOCD 7, 169-179, 2008).
Eyelids and Periorbital TreatmentEnergist NeoGen PSR is the ideal option for the treatment of the upper and lower eyelids, as well as the wider periorbital region. Other technologies cannot be used in this area or deliver inconsistent results.
Long Lasting ResultsClinical studies show neocollagenesis and reduction in elastosis continuing for more than one year post treatment.The Proven Power of Plasma for Skin Regeneration Energist NeoGen PSR Laser• Unique technology – controlled pulses of nitrogen plasma energy
• Treats the whole skin architecture – no islands of untreated skin remain
• Deep Tissue Remodelling – epidermis acts as natural dressing post treatment
• Versatile – high or low energy treatment choices to fit your patients’ needs and lifestyle
• Precise – treat eyelids effectively with significant results
• Long-lasting effects – intense fibroblast activity supports continued regeneration.
• Consistent – non-fractionated and non-chromophore dependence assures uniform energy absorption
• Proven Plasma Skin Regeneration is supported by numerous IRB-controlled studies
TechnologyPlasma skin regeneration was introduced with a level of scientific and clinical testing never before seen in the industry:
• 3+ years of pre-clinical and clinical testing
• 16 separate studies
• more than 450 clinical study treatments –No scarring or Hypopigmentation noted in studies
• one year clinical histology
This level of testing is very rare in the industryEnergist NeoGen PSR uses a highly energized gaseous state known as plasma to produce a unique thermal profile to penetrate the superficial and deeper levels of the dermis to replace damaged collagen and encourage new collagen growth for new skin. Plasma is produced inside the handpiece through the combination of inert nitrogen gas and ultra-high frequency RF.The Energist NeoGen PSR is emitted in millisecond pulses; the longer the pulse, the more energy is delivered. Nitrogen molecules impact the skin’s surface and immediately transfer energy upon contact. When the nitrogen plasma impacts the skin surface, energy is immediately transferred to the tissue. Oxygen is purged from the skin surface by the plasma, preventing carbonisation. The energy delivered to tissue ranges from 1 – 4 Joules and is user-adjustable. The repetition rate of the plasma pulses can also be controlled, and ranges from 1 – 2.5 Hertz.Specifications Energist NeoGen PSR| Power: | 100 – 120 / 230 Vrms – 50/60 Hz – 650 Va | | Energy Output: | Pulsed nitrogen plasma – 1-4 Joules. | | Repetition Rate: | 1.0 – 2.5Hz | | Dimensions: | 470 x 430 x 1060mm | | Gas Requirement: | Medical Grade Nitrogen | | System Weight: | 18kg/40lb | | Trolley Weight: | 25kg/55lb (excludes gas tank) | | Ambient Environment: | 0 to 40 celsius | | Relative Humidity: | 30 to 75% | | atmospheric pressure: | 700 to 1600 hpa |
| CUTERA SECRET RF 2.0CUTERA SECRET RF 2.0 MICRONEEDLING RADIO is a fractional micro-needling system (fractional radiofrequency) that exceeds the capabilities and limitations of fractional laser significantly. It is a system for extensive skin structure improvement and treatment of hyperhidrosis (radio frequency thermotherapy RFTT), based on both monopolar and fractionated on, bipolar radio frequency. An exact adjustment of the depth of the microneedles and the cold passing the epidermis allow the energy output directly into the target layer.
The needle depth is 0.5 mm to 3.5 mm can be varied, thereby opening up a wide range of treatments. The adjustable intensity of the RF energy allows for the treatment of various areas of the body with different energy performance.The ability to work specifically in the deep dermis, without damaging the epidermis, is regulated in the RF Secret by the delay time of fractional radiofrequency. The needles are inserted at a rate of milliseconds equal to a stamping process in the skin and also withdrawn immediately. Only after the needles are penetrated into the desired skin layer, is carried out for a few milliseconds, a radio frequency pulse to set heat damage. While the penetration into the skin, the needles remain always cold. In order to achieve a deep and superficial effect, the needle depths can be varied individually in the respective treatment passes.Dermal Remodeling from the Inside Out
Demand for non-surgical aesthetic procedures with little to no downtime is on the rise. More than 70% of patients are bothered by signs of aging such as fine lines and wrinkles as well as skin texture and discoloration.1Secret RF is a novel fractional radio frequency (RF) micro-needling system for tissue coagulation and hemostasis designed to stimulate and remodel collagen and address the common signs of aging. It is ideally suited for use on patients who wish to revitalize and refresh the appearance of their skin on all skin types. By adjusting the micro-needles, Secret RF can deliver energy at various depths, so that treatments can be tailored to address each patients individual concerns such as fine lines, wrinkles, acne scars, photoaging and striae at the depth required.Secret RF System
Secret RFs unique technology and customized delivery of energy enables providers to tailor treatments for a variety of skin concerns on all skin types.Customized Dermal Remodeling
Secret RF induces dermal remodeling by applying precisely controlled RF energy directly into various depths of skin from 0.5-3.5 mm – with minimally invasive micro-needles to spare the epidermis and reduce patient downtime.Skin Revitalization and Resurfacing Secret RF is a radio frequency (RF) fractional microneedling system that helps you deliver tailored energy to improve fine lines, wrinkles, and scars from the inside out. Secret RF in action
Applications include fine lines and wrinkles, photoaging, scarring, acne scars, striaeSecret RF technology Handpieces
Two sizes of treatment tips – 25 and 64 pin – give you customizable options for treating the face and body with precision and efficiency.
Power:20 W ± 20%
RF frequency:2 Mh ± 20%
Intensity:0 ~ 100 Level (10 levels)
Repeat:0.2 / 0.5 / 1/2 sec / individually.
Needle Size:0.3 mm
Info about needles:25 electric needles (5 x 5, 7.8 mm x 7.8 mm / height: 1.95 mm (standard) and 16 electric needles (4 x 4, 7.8 mm x 7.8 mm / height 2.6 mm (optional)
Treatment range:1 x 1cm
Adjustable Depth:0.5 ~5 mm (0.1 steps)
Treatment duration:50 ms ~ 950 ms
Electrical power:100 ~ 240 VAC, 50/60 Hz, 220 VAMonopolar RF
Power:520 W ± 20%
RF frequency:2 Mh ± 20%
RF electrode:monopolar
Repeat:CW
RF electrode size:15APPLICATIONSFacialsNon-surgical facelift
Skin tightening
Pore reduction
Wrinkle reduction
Skin Rejuvenation (illumination)
Acne scars
Body treatmentsScar
Keratosis pilaris (Keratosis pilaris)
Stretch marks | Inmode Aesthetics Optimas with Lumecca 515 & 580LUMECCA
SR515
Spot size:10x30mm
Pulse Repetition:1pps at all energies
Wavelength:515-1200nm
Fluence:10-30J/cm2
Peak Power:High Peak Power
Pulse Duration:Short/Long
Cooling:Controlled
SR580
Technology:IPL
Spot size:10x30mm
Pulse Repetition:1pps at all energies
Wavelength:580-1200nm
Fluence:10-30J/cm2
Peak Power:High Peak Power
Pulse Duration:Short/Long
Cooling:Controlled
FORMA
RF Output Frequency: Up to 65 W
Output Frequency: 1 MHz
Temperature Cut-Off: Real time temperature measurements set by operator up to 43°C
FRACTORA
24 Pin:Type – Full Thickness Dermal; Configuration – 6×4; Pin Length – 3000u; Ablation Depth – 3 mm; Heating Depth – Between 3-5 mm; Max Output Energy 62 mj/pin; Output Frequency – 1 MHz; Repetition Rate – Up to 2 pps
24 Pin Coated:Type – Deep and Subdermal; Configuration – 6 x 4 Coated; Pin Length – 3000 u, Ablation Depth – 3 plus mm; Heating Depth – Between 3-5 mm; Max Output Energy 62 mj/pin; Output Frequency – 1 MHz; Repetition Rate – Up to 2 pps
60 Pin:Type – Mid Dermal; Configuration – 10×6; Pin Length – 600u; Ablation Depth – 0.6-1 mm; Heating Depth – Between 3-5mm; Max Output Energy 62 mj/pin; Output Frequency – 1 MHz; Repetition Rate – Up to 2 pps
DIOLAZEXL
Laser Wavelength:810 nm (diode)
Spot Size:12mm x 26 mm
Fluence:Up to 40 J/cm2
Pulse Duration:Short/Long
Light Cooling Guide:2-15°C
Repetition Rate:Single and Auto-Repeat
VASCULAZE
Laser Wavelength:1064 nm (diode)
Spot Size:3mm x 4mm
Fluence:40-300 J/cm2
Pulse Duration:5-100 msec
Light Cooling Guide:7-12° C
VLAZE
Laser Wavelength:1064 nm (yag)
Spot Size: 4 mm x 5 mm
Fluence: Up to 300 J/cm2
Pulse Duration: 5 ms 25 ms
MORPHEUS8
Type:Deep and Subdermal
Pin Length:4000
Ablation Depth:5mm +
Max Energy:62 mJ/pin at 75 W
Frequency:1 MHz
Repetition Rate:Up to 2 pps
A FULL BEAUTY SUITE
Optimas will help you optimize results for your patients and your businessProfessional grade aesthetic procedures – Optimas is a great suite of innovations in one workstation to help you achieve your goals. The Optimas full beauty suite has state-of-the-art light, laser, and radiofrequency devices for skin care and hair removal.Available Handpieces : Inmode Aesthetics Optimas with Lumecca 515 & 580
LUMECCA
FORMA
FRACTORA
DIOLAZEXL
VASCULAZE
VLAZE
MORPHEUS8LUMECCA
Fastest IPL Results*
*Clearance in 1-2 sessions, compared to 4-5 sessions with competing devicesLumecca is a breakthrough intense pulsed light (IPL) that delivers up to 3X more energy in the 500-600 nm range to improve efficacy for vascular and pigmented lesions. It is optimized for clinicians to treat a variety of skin types and conditions with just a single session.SR515 – Removal of Pigmented Lesions on Light Skin, Removal of Superficial Vascular Lesions
SR580 – Removal of Pigmented Lesions on DARK SkiN, Removal of DEEP Vascular Lesions, Removal of Vascular Lesions on DARK SkinFORMA
Face Remodeling.
Stimulates the formation of new collagen and improves the skin’s elasticity for long-lasting and remarkable resultsForma is the first auto-adjusting, non-invasive, thermal skin treatment for deep and uniform tissue stimulation. Forma uses radio-frequency power that flows uniformly between the electrodes to provide a comfortable thermal experience with immediate and subsequent contraction. There is no downtime in this effective lunch-time procedure that will make anyone look years younger!Acquire: Forma has a temperature sensor built into the hand piece which reads skin surface temperature 1000 times per second, allowing clinicians to acquire skin temperature in real time.
Control: Software algorithm allows unprecedented safety of RF delivery. The cut off temperature” feature reduces RF energy automatically when the hand piece senses that the required skin temperature has been reached.
Extend: Clinical evidence suggests prolonged exposure to temperature above 40°C is advantageous for optimal clinical outcomes. Only InMode’s A.C.E. technology allows you to utilize therapeutic temperatures safely and efficiently.FRACTORA Inmode Aesthetics Optimas with Lumecca 515 & 580
Radio Frequency MicroNeedling.
Fractora is a fractional skin resurfacing and subdermal tissue coagulation device that bridges the gap between fractional lasers and surgical procedures. Clinical papers demonstrate outcomes such as: improvement in skin complexion, reduction in skin irregularities and restoring skin to a more youthful appearance. This all occurs within one session or multiple sessions, depending on patient preference. Fractora can be used on active cystic acne and acne scars.Addresses multiple problems, including treatment of wrinkles with fractional coagulation and ablation.
Significant resolution of cystic acne and scars (improving acne scarring by 50%).
Safe on skin type VI with little risk of post inflammatory hyperpigmentation (PIH) which is common with other resurfacing methods.
Combination of fractional coagulation and volumetric heating through tips with various depths and pin density configurations.High efficiency of vascular and pigmented lesions due to high peak power and optimized output.
Complete photo rejuvenation in 1 or 2 treatments versus 4-6 treatments with standard IPLs.
Reduces treatment time thanks to large spot size and high pulse repetition rate.
Strong sapphire cooling tip results in painless procedure.
Fast pulse repetition rate at all settings. Highest peak power 3300W*DIOLAZEXL
Diode Hair Removal.
Gold Standard Diode Hair Removal Without Compromising Peak Power, Speed and Large Spot SizeDiolazeXL is the most effective at combining high peak power and a large spot size simultaneously in the same session. Clinicians can benefit from this first and only combination of speed, efficacy, safety and comfort to optimize their hair removal revenue.Gold standard wavelength, pulsing and power for optimal results and maximal safety.
Reduction in clinician treatment time – Powerful enough to target and treat even the most stubborn hair.
Virtually painless due to strong built in cooling.
Can treat up to skin type VI.VASCULAZE
Vascular Lesion Removal.
Get the ultimate in vascular resolution with a fast and chilled leg and facial vein treatmentVascular lesions (including angiomas, telangiectasias, port wine stains and leg veins) can be treated with the Vasculaze. The Vasculaze is optimized with high peak power that targets appropriate hemoglobin, so patients can benefit from a fast and safe treatment.Narrow and ergonomic spot size is optimized for vascular lesion treatment. High peak power. Strong contact cooling. No disposables and consumables.VLAZE
Vascular Lesion Removal.
Fast, powerful and ergonomic laser device. Treats vascular lesions such as veins, spider veins and port wine stains safely, comfortably and effectively on all skin types from very light to darker skin tones.MORPHEUS8
THE FIRST FULL BODY FRACTIONATED TECHNOLOGY
Fractional Remodeling and Contouring At Its BestThe Morpheus8 is a new subdermal adipose remodeling device (SARD) that fractionally remodels and contours the face and body. Penetrating deep into the skin and fat, this morphs the aging face of body into a more desired smooth and sleek appearance, for all skin tones.Deep and safe fractional treatment penetrating 4000 microns with an additional thermal profile of 1000+ microns
Extremely uniform effect
Little to no thermal damage to dermis
Safe on skin type VI with little risk of post inflammatory hyperpigmentation (PIH) which is common with other resurfacing methods. | Cutera Excel HR 1064 755 Hair Removal SystemAlexandrite
Wavelength:755 nm
Maximum Energy:53J
Pulse Duration:3 ms
Spot Size:5-18 mm
Repetition Rate:2 HzNd Yag
Wavelength:1064 nm
Maximum Energy:80J
Pulse Duration:0.1 – 300 ms
Spot Size:3-12 mm
Repetition Rate:Up to 10 Hz
Cooling:Contact Sapphire
Aiming Beam:635 nm
Dimensions:35″ H x 12″ W x 24″ D
Electricial:200-240 VAC, 50/60 Hz, 20A/30ACooling:Contact Sapphire
Aiming Beam:635 nm
Dimensions:35″ H x 12″ W x 24″ D
Electricial:200-240 VAC, 50/60 Hz, 20A/30A
Superior, Comfortable Laser Hair Removal
Laser Hair Removal An In-demand Procedure
Global hair removal procedures are growing at a rapid pace. Laser hair removal has been among the top non-surgical procedures according to the American Society of Aesthetic Plastic Surgery and procedure revenue is anticipated to go to $1.35B by 20221. The industry often refers to laser hair removal as a gateway procedure as it offers an entry point into the aesthetic market for patients and practitioners alike.excel HR combines a high-power 755 nm Alexandrite laser and Cuteras proven long-pulse 1064 nm Nd:YAG laser for safe, effective high-volume hair removal on all skin types. The combination of wavelengths not only allows for effective hair removal, but is also a solution for epidermal pigmented lesions, vascular lesions and Cuteras signature laser genesis skin revitalization procedure.excel HR Technology
Proven Wavelengths
excel HR combines the gold standard laser wavelengths for hair removal. The 755 nm Alexandrite laser is highly absorbed by melanin making it an ideal solution for finer hair on skin types I-III. Because of the high melanin absorption characteristics, it has also been proven to provide long-term results on epidermal pigmented lesions.The 1064 nm Nd:YAG is the safest wavelength for permanent hair reduction on darker skin types and tanned skin. By selecting the appropriate spot size, this laser can also be used for treating facial and leg veins and perform laser genesis procedure.truPulse Delivery with Index Matching
Unique to Cutera, the truPulse technology delivers constant, sustained energy throughout the pulse duration to ensure consistent performance and proven clinical outcomes for your patients.excel HRs index matching delivery results in more efficient coupling of laser energy to target structures. Index matching allows backscattered light to escape, further protecting the epidermis from heat build-up while maintaining treatment efficacy.Superior Contact Cooling
excel HR utilizes sapphire contact cooling to provide continuous cooling, maximizing your patients comfort and treatment safety.2 In a patient preference study that measured comfort and satisfaction for laser hair removal, 100% of the patients preferred excel HR over a comparable, competitive laser hair removal procedure.321st Century Laser Hair Removal System
Developed by the innovative leader in aesthetic laser technology, excel HR laser hair removal system provides advanced premium hair removal solutions for every skin type. Combining a new high-power 755 nm Alexandrite laser, and CUTERAs proven long-pulse 1064 nm Nd:YAG laser, coupled with the superiority of sapphire contact cooling, excel HR redefines modern laser hair removal.This makes excel HR laser system an effective, safe and comfortable option for laser hair removal for the 21st century.Applications Cutera Excel HR 1064 755 Hair Removal System
– Hair removal
– Benign pigmented lesion removal
– Veins, facial
– Veins, leg
– Laser Genesis |
Reviews
There are no reviews yet.