| Description | The Profound system provides a non-surgical alternative to address aging skin:
Using radiofrequency (RF) injectable energy, it provides long-lasting facial wrinkle reduction and improves the appearance of cellulite. | The ability to work specifically in the deep dermis, without damaging the epidermis, is regulated in the RF Secret by the delay time of fractional radiofrequency. The needles are inserted at a rate of milliseconds equal to a stamping process in the skin and also withdrawn immediately. Only after the needles are penetrated into the desired skin layer, is carried out for a few milliseconds, a radio frequency pulse to set heat damage. While the penetration into the skin, the needles remain always cold. In order to achieve a deep and superficial effect, the needle depths can be varied individually in the respective treatment passes. | The new highly accurate 0.5 mm milling tool reliably delivers first class clinical results. Switch to Extra Fine milling mode for a higher level of detail with occlusal fissures and interdental areas on bridges. | ACTIVE OPTICAL SYSTEMS OPTIMA 518 IPL LASER includes: Handpiece, Footswitch, Operator Eyewear, Patient Eyewear, Cart, Key, Operator Manual, ultrasound gel, replacement fuses, replacement filters | New Handpiece Design The Optima – 518 Classic is the first model to use the new Mark II which enables a multipurpose handpiece:
* Faster treatments – up to 0.5 Seconds Between pulses.
* Real-time handpiece temperature control.
* Contemporary and stylish design.
* Light weight design – 25% less weight to improve the therapists’ comfort. | Candela GentleMAX ProEstablished in 1970, Candela is a leading US-based global medical aesthetic device company with headquarters in Wayland, Massachusetts. The company’s technologies enable physicians to provide advanced energy-based solutions for a broad range of medical-aesthetic applications including benign vascular and pigmented lesions, scars, hair removal, facial resurfacing, wrinkle reduction, women’s health treatments, tattoo removal, acne, leg veins, cellulite, and body shaping. |
| Content | Syneron Candela Profound RF MicroneedlingUsing radiofrequency (RF) injectable energy, it provides long-lasting facial wrinkle reduction and improves the appearance of cellulite.Key Benefits of Profound RF Microneedling
The Profound system can help your practice:Fill the treatment gap that exists between dermal injectables and invasive surgery* Adopt new patients in advance of surgery
* Retain existing patients who are not ready for surgical procedures
* Increase revenue with complementary treatments and future proceduresBottom line:The Profound system enhances aesthetics practices by providing a clinically proven, non-surgical, single-treatment procedure1,4,5 that requires less practice expense and patient downtime.Profound Specifications- Syneron Candela Profound System
- SubQ Applicator
- SubDermal Applicator
- 4 SubQ Cartridges
- 6 SubDermal Cartridges
- Power Cord
Profound Benefits and Applications Syneron Candela Profound RF Microneedling- radio frequency microneedling
- treatment of wrinkles
- treatment of cellulite
- treatment on both dermal and adipose tissue
Syneron Candela Profound RF Laser is a One-of-a-Kind Wrinkle & Cellulite Treatment System
8 facts that make this a one-of-a-kind, must-have system.* Clinically proven to create all 3 skin fundamentals: up to 5x more elastin, up to 2x more collagen, and increased hyaluronic acid.1,4
* First and only RF microneedling device with FDA clearance for face and body4
* Just one non-surgical treatment required to achieve lasting results2,4,5,6
* 100% response rate for facial wrinkles5,7
* 94% response rate for improvement in the appearance of cellulite4,7,8
* Reduces the appearance of cellulite severity with only one non-surgical treatment4,8,9
* The only real-time, temperature-controlled RF microneedling device4
* Proven in 8 comprehensive clinical studiesThe Syneron Candela Profound RF Laser system utilizes a minimally invasive microneedle electrode array to deliver bi-polar RF energy directly into the deep reticular dermis, without thermal impact to the epidermis. A controlled high-volume fractional injury to the deep dermis creates new collagen, elastin and hyaluronic acid.This revolutionary and unique approach enables you to create true fractionated zones of thermal injury where it will have the greatest impact, providing a solid foundation of new dermal volume.Features ePrime’s patented Intelligent Feedback Systems, (IFS) measures impedance and monitors real time, and temperature for constant adjustment of power levels regardless of varying skin conditions or skin types. | CUTERA SECRET RF 2.0CUTERA SECRET RF 2.0 MICRONEEDLING RADIO is a fractional micro-needling system (fractional radiofrequency) that exceeds the capabilities and limitations of fractional laser significantly. It is a system for extensive skin structure improvement and treatment of hyperhidrosis (radio frequency thermotherapy RFTT), based on both monopolar and fractionated on, bipolar radio frequency. An exact adjustment of the depth of the microneedles and the cold passing the epidermis allow the energy output directly into the target layer.
The needle depth is 0.5 mm to 3.5 mm can be varied, thereby opening up a wide range of treatments. The adjustable intensity of the RF energy allows for the treatment of various areas of the body with different energy performance.The ability to work specifically in the deep dermis, without damaging the epidermis, is regulated in the RF Secret by the delay time of fractional radiofrequency. The needles are inserted at a rate of milliseconds equal to a stamping process in the skin and also withdrawn immediately. Only after the needles are penetrated into the desired skin layer, is carried out for a few milliseconds, a radio frequency pulse to set heat damage. While the penetration into the skin, the needles remain always cold. In order to achieve a deep and superficial effect, the needle depths can be varied individually in the respective treatment passes.Dermal Remodeling from the Inside Out
Demand for non-surgical aesthetic procedures with little to no downtime is on the rise. More than 70% of patients are bothered by signs of aging such as fine lines and wrinkles as well as skin texture and discoloration.1Secret RF is a novel fractional radio frequency (RF) micro-needling system for tissue coagulation and hemostasis designed to stimulate and remodel collagen and address the common signs of aging. It is ideally suited for use on patients who wish to revitalize and refresh the appearance of their skin on all skin types. By adjusting the micro-needles, Secret RF can deliver energy at various depths, so that treatments can be tailored to address each patients individual concerns such as fine lines, wrinkles, acne scars, photoaging and striae at the depth required.Secret RF System
Secret RFs unique technology and customized delivery of energy enables providers to tailor treatments for a variety of skin concerns on all skin types.Customized Dermal Remodeling
Secret RF induces dermal remodeling by applying precisely controlled RF energy directly into various depths of skin from 0.5-3.5 mm – with minimally invasive micro-needles to spare the epidermis and reduce patient downtime.Skin Revitalization and Resurfacing Secret RF is a radio frequency (RF) fractional microneedling system that helps you deliver tailored energy to improve fine lines, wrinkles, and scars from the inside out. Secret RF in action
Applications include fine lines and wrinkles, photoaging, scarring, acne scars, striaeSecret RF technology Handpieces
Two sizes of treatment tips – 25 and 64 pin – give you customizable options for treating the face and body with precision and efficiency.
Power:20 W ± 20%
RF frequency:2 Mh ± 20%
Intensity:0 ~ 100 Level (10 levels)
Repeat:0.2 / 0.5 / 1/2 sec / individually.
Needle Size:0.3 mm
Info about needles:25 electric needles (5 x 5, 7.8 mm x 7.8 mm / height: 1.95 mm (standard) and 16 electric needles (4 x 4, 7.8 mm x 7.8 mm / height 2.6 mm (optional)
Treatment range:1 x 1cm
Adjustable Depth:0.5 ~5 mm (0.1 steps)
Treatment duration:50 ms ~ 950 ms
Electrical power:100 ~ 240 VAC, 50/60 Hz, 220 VAMonopolar RF
Power:520 W ± 20%
RF frequency:2 Mh ± 20%
RF electrode:monopolar
Repeat:CW
RF electrode size:15APPLICATIONSFacialsNon-surgical facelift
Skin tightening
Pore reduction
Wrinkle reduction
Skin Rejuvenation (illumination)
Acne scars
Body treatmentsScar
Keratosis pilaris (Keratosis pilaris)
Stretch marks | DENTSPLY SIRONA CEREC PRIMEMILLSpeedEngineered for speed and precision, the new CEREC Primemill inherits the proven strength of its predecessor and raises its powerful performance to entirely new heights.You can now mill zirconia restorations in Super Fast milling mode in around 5 minutes, cutting processing times by more than half. The improved grinding mode for high quality glass ceramics also grinds the material faster than ever before. The result? Satisfied patients and high productivity.QualityDENTSPLY SIRONA CEREC PRIMEMILL A combination of new electronics, software, motors and mechanical components contributes to finer resolution and enhanced dynamics. This results in outstanding restoration margins and surface details – for extremely precise results.The new highly accurate 0.5 mm milling tool reliably delivers first class clinical results. Switch to Extra Fine milling mode for a higher level of detail with occlusal fissures and interdental areas on bridges.VersatilityDENTSPLY SIRONA CEREC PRIMEMILL Welcome to a world where you‘re spoiled for choice! The new CEREC Primemill combines wet and dry milling and wet grinding. No matter the indication, with CEREC Primemill you can select from a broad range of material options from validated partners providing the flexibility and predictability you need to offer patients the best possible treatment.Choose from the full spectrum of machining options, including dry and wet milled zirconia, or wet grinding of glass and hybrid ceramics.ConvenienceDENTSPLY SIRONA CEREC PRIMEMILL The new 7” touch interface with user guidance guides operators step-by-step through the workflow, key maintenance procedures and other routine tasks, so you can delegate milling with complete peace-of-mind. The integrated block scanner is a time-saving new feature that automatically scans material blocks with compatible data matrix codes and records the information, including type, size, color and zirconia enlargement factor. All CEREC Primemill tools are fitted with a color-coded RFID chip that is read by the RFID tool reader, feeding into the tool status display, alerting the user if a tool needs replacing. This ensures all tools are performing at optimal levels. A LED light strip indicates unit status and milling and grinding progress.The all-new CERECThe latest generation of our CEREC system sets new standards so you can offer your patients an unmatched combination of single-visit dentistry and excellent quality.A unique solutionThe CEREC system comprises world-class components that interact perfectly ensuring seamless workflows. With CEREC Primescan, CEREC Software 5 and CEREC Primemill, digital chairside dentistry is faster, easier and more reliable than ever before.Outstanding resultsAfter 35 years of continuous optimization, CEREC gives you the options you need to treat multiple indications with the confidence that comes from outstanding results.
Designed to stand out – and fit inThe new CEREC Primemill does not just communicate seamlessly with other CEREC devices, but its sleek design is also the perfect match – and the ideal look for a progressive dental practice. | Active Optical Systems Optima 518 IPL LaserHandpiece (Standard):Multipurpose Wavelength Mark-II
Handpiece (Optional):Facial Treatments
Pulse Interval/Repetition Rate:0.5 – 2 Seconds
Maximum Output Treatment Pattern:22 Joule /cm 2
Output Power:11-31 Joule / cm 2 , up to 4000 W
Cooling System:Improved Air Cooling
Control:Advanced Software Interface
Lamp’s Life Span:200,000 Flashes (minimum)
Treatment Area/Spot Size:15 x 50 mm, (7.5 cm 2)
Wavelength:420 – 1,100 nm
Weight:88.18 lbs (40Kg) (including stand)
Dimensions:17.32 inches x 17.72 inches x 39.37 inches (44cm x 45cm x 100cm)
Mains:220-230 VAC, 50/60 Hz; 100-120 VAC, 50/60 Hz
Max Mains Power:600 VA
Treatments Variety:
Skin Rejuvenation
Pigmentation Treatment
Acne Treatment
Hair Removal
Hair Removal – Deep Follicles
Hair Removal – Sensitive Skin
Vascular (Facial) Treatment
Tattoo Removal
ACTIVE OPTICAL SYSTEMS OPTIMA 518 IPL LASERr uses 12 preset programs. The programs are set in a consecutive, energy intensity increasing order, as specified by the tables of settings, covering all types of hair and skin combinations to be treated.
12 Programs
1 – Very Dark Skin, Fitzpatrick Skin Type IV
2 – Dark Skin, Fitzpatrick Skin Type IV
3 – Dark Skin, Fitzpatrick Skin Type III
4 – Dark Skin, Fitzpatrick Skin Type III
5 – Medium Skin, Fitzpatrick Skin Type II
6 – Medium Skin, Fitzpatrick Skin Type II
7 – Light Skin, Fitzpatrick Skin Type II
8 – Light Skin, Fitzpatrick Skin Type I
9 – Very Light Skin, Fitzpatrick Skin Type I
10 – Very Light Skin, Fitzpatrick Skin Type I
11 – Very Light Skin, Fitzpatrick Skin Type I
12 – High Power, Fitzpatrick Skin Type IActive Optical Systems Optima 518 IPL LaserOptima-518-Classic
The Optima – 518 Classic was designed to answer the needs of sophisticated practitioners who want to provide state of the art treatment to their patients on one hand, based on proven and tested treatment protocols and on the other hand to have the ability to reach new and improved protocols by conducting innovative clinical investigations.The Optima – 518 Classic, based on active’s GEM-PL technology, sets the pulse pattern according to the selected treatment type, skin color, skin photosensitivity and treatment depth. The treatment protocols and different pulse patterns take into account the tissue’s TRT (Thermal Relaxation Time) and the combined knowledge accumulated from thousands of treatments done during the years and clinical investigations done to confirm the findings.ACTIVE OPTICAL SYSTEMS OPTIMA 518 IPL LASERNew Handpiece Design The Optima – 518 Classic is the first model to use the new Mark II which enables a multipurpose handpiece:
* Faster treatments – up to 0.5 Seconds Between pulses.
* Real-time handpiece temperature control.
* Contemporary and stylish design.
* Light weight design – 25% less weight to improve the therapists’ comfort.Research program for clinical investigations, the self setting program allows researchers to set the treatment’s parameters according to their needs. Allowing advanced research with the device. The energy levels in the self setting program can reach 31J cm 2 with high intensity of 4000 W.ACTIVE OPTICAL SYSTEMS OPTIMA 518 IPL LASER Approvals
* CE MDD Intl. Medical Standard
* FDA U.S. Safety Standard
* ISO-13485 Med. Production STD
* IEC 60-601-1 Medical Safety STD
* CFS Gov. Health Approval
* CSA Can. & U.S. Safety App
* TGA Australian health STD. | Active Optical Systems Optima 518 IPL LaserHandpiece (Standard):Multipurpose Wavelength Mark-II
Handpiece (Optional):Facial Treatments
Pulse Interval/Repetition Rate:0.5 – 2 Seconds
Maximum Output Treatment Pattern:22 Joule /cm 2
Output Power:11-31 Joule / cm 2 , up to 4000 W
Cooling System:Improved Air Cooling
Control:Advanced Software Interface
Lamp’s Life Span:200,000 Flashes (minimum)
Treatment Area/Spot Size:15 x 50 mm, (7.5 cm 2)
Wavelength:420 – 1,100 nm
Weight:88.18 lbs (40Kg) (including stand)
Dimensions:17.32 inches x 17.72 inches x 39.37 inches (44cm x 45cm x 100cm)
Mains:220-230 VAC, 50/60 Hz; 100-120 VAC, 50/60 Hz
Max Mains Power:600 VA
Treatments Variety:
Skin Rejuvenation
Pigmentation Treatment
Acne Treatment
Hair Removal
Hair Removal – Deep Follicles
Hair Removal – Sensitive Skin
Vascular (Facial) Treatment
Tattoo Removal
The Laser uses 12 preset programs. The programs are set in a consecutive, energy intensity increasing order, as specified by the tables of settings, covering all types of hair and skin combinations to be treated.
12 Programs
1 – Very Dark Skin, Fitzpatrick Skin Type IV
2 – Dark Skin, Fitzpatrick Skin Type IV
3 – Dark Skin, Fitzpatrick Skin Type III
4 – Dark Skin, Fitzpatrick Skin Type III
5 – Medium Skin, Fitzpatrick Skin Type II
6 – Medium Skin, Fitzpatrick Skin Type II
7 – Light Skin, Fitzpatrick Skin Type II
8 – Light Skin, Fitzpatrick Skin Type I
9 – Very Light Skin, Fitzpatrick Skin Type I
10 – Very Light Skin, Fitzpatrick Skin Type I
11 – Very Light Skin, Fitzpatrick Skin Type I
12 – High Power, Fitzpatrick Skin Type IOptima-518-Classic Active Optical Systems Optima 518 IPL LaserThe Optima – 518 Classic was designed to answer the needs of sophisticated practitioners who want to provide state of the art treatment to their patients on one hand, based on proven and tested treatment protocols and on the other hand to have the ability to reach new and improved protocols by conducting innovative clinical investigations.The Optima – 518 Classic, based on active’s GEM-PL technology, sets the pulse pattern according to the selected treatment type, skin color, skin photosensitivity and treatment depth. The treatment protocols and different pulse patterns take into account the tissue’s TRT (Thermal Relaxation Time) and the combined knowledge accumulated from thousands of treatments done during the years and clinical investigations done to confirm the findings.New Handpiece Design The Optima – 518 Classic is the first model to use the new Mark II which enables a multipurpose handpiece:
* Faster treatments – up to 0.5 Seconds Between pulses.
* Real-time handpiece temperature control.
* Contemporary and stylish design.
* Light weight design – 25% less weight to improve the therapists’ comfort.Research program for clinical investigations, the self setting program allows researchers to set the treatment’s parameters according to their needs. Allowing advanced research with the device. The energy levels in the self setting program can reach 31J cm 2 with high intensity of 4000 W.Approvals
* CE MDD Intl. Medical Standard
* FDA U.S. Safety Standard
* ISO-13485 Med. Production STD
* IEC 60-601-1 Medical Safety STD
* CFS Gov. Health Approval
* CSA Can. & U.S. Safety App
* TGA Australian health STD. | 2017 Candela GentleMAX Pro Device DetailsThe Candela GentleMax Pro yields high energy, subjecting patients to fewer laser pulses providing faster treatment times with the 24mm spot size, the largest spot found on any hair removal laser. Candela’spatented Dynamic Cooling Devise (DCD) technology protects the upper layers of skin with cooling bursts of cryogen. DCD cooling offers optimal treatment with minimal side effects.| Distributor | Candela |
|---|
| Manufacturer | Candela |
|---|
| Model | GentleMAX Pro |
|---|
| Manufactured Year | 2017 |
|---|
| Specific Equipment Type | Dual Wavelength Laser |
|---|
| Sale Price | 12500 |
|---|
| Treatments Performed | Hair Removal, Vascular, Pigmentation
Skin Rejuvenation
Skin Tightening |
|---|
| Handpieces | Standard Handpiece DCD 12-18mm , Large Spot Size Handpiece DCD 22-24mm |
|---|
| Shot Counts | None |
|---|
| Wavelengths | 755nm
1064nm |
|---|
| Consumables used by device | Windows, Distance Gauges |
|---|
| Consumables with purchase | 3 x Operator goggles, 1 x patient goggles, distance gauges, windows |
|---|
| Annual Service Price | Servicing available through Candela |
|---|
| Service Contract Price | $11,000 per annum |
|---|
| Additional Information | Any additional information can be sent on request |
|---|
| |
|---|
Treatments:2017 Candela GentleMAX Pro Device Details- Hair Removal
- Beard Bumps
- Facial Lesions
- Fine Lines and Wrinkles
- Leg Veins
- Skin Tightening
- Vascular Lesions
- Warts
- Skin Rejuvenation
- Hemangiomas
- Birthmarks
- Freckles
- Melasma
- Mevus of Ota
- Pigmented Lesions
- Sun / Age Spots
The Candela GentleMax Pro yields high energy, subjecting patients to fewer laser pulses providing faster treatment times with the 24 mm spot size, the largest spot found on any hair removal laser.Fast – With 24 mm spot size and repetition rates up to 2 Hz, the The Candela GentleMax Pro yields high energy, subjecting patients to fewer laser pulses providing faster treatment times with the 24 mm spot size, the largest spot found on any hair removal laser. It has two wavelengths, the 755 Alexandrite and the 1064 ND:yag, allowing you to offer many treatment options.Candela’s patented Dynamic Cooling Devise (DCD) technology protects the upper layers of skin with cooling bursts of cryogen. DCD cooling offers optimal treatment with minimal side effects. offers fast treatment times with it’s spot size.Powerful – 26,333 watts peak power, capable of delivering fluences up to 100 J/cm² for vascular applications, and hair removal energy in pulse duration as short as 3 ms for unparalleled treatment efficacies.Treats all skin types – Deep penetration with minimal scattering of laser energy makes the GentleMax Pro ideal for all skin types, particularly dark and tanned skin.Versatile – Non-ablative treatment, including fine lines and wrinkles, and for pseudofolliculitis barbae (PFB), or beard bumps, leg and facial veins.Patented Epidermal Cooling – Candela’s Dynamic Cooling Device represents an adjustable epidermal protection technology to maximize patient safety and comfort.Date of Manufacture – 2017Accessories Included with Purchase – Specialty 1.5, 3mm, 3x10mm Handpiece, 6, 8, 10, 12, 15, 18mm Handpiece, Full Set of Distance Gauges, Distance Gauge Case, Patient Eyewear, Treatment Goggles, Foot Pedal, Fiber Pole, System Key, System Interlock Key, Treatment Guidelines, and User Manual. |