Description | babyPAC is specially designed to deliver ventilation to small, fragile lungs of patients ranging from neonates through pediatrics up to 20kg with precision and confidence. It has a sophisticated range of ventilation controls including CPAP, variable I:E ratio and variable oxygen concentration. The babyPAC also incorporates a comprehensive range of alarms. | The Newport HT70 plus ventilator combines ruggedness, ease of use, and clinical proficiency with exceptional mobility for patients from 5kg to adult. All models of the Newport HT70 plus ventilator family can be used for home care, transport, hospital, long-term care, and emergency preparedness, as well as for invasive or noninvasive ventilation. | Features and Benefits- Small, compact, and transport ready.
- Designed to perform in harsh and toxic environments.
- Assembles quickly with simplified operating instructions printed on the case.
- Impact-resistant case with shock-absorbing bumpers and recessed control settings.
- Rate and volume settings independently operated.
- Easy-to-monitor patient valve assembly and toxic atmosphere valve are able to deliver additional breaths on demand by inspiratory effort of the patient.
- Operates exclusively on standard 50 psi source gas, eliminating air entrainment and maintaining the integrity of the specified oxygen concentration.
- Operates at extreme temperatures ranging from 0° F to 125° F.
- Pneumatically powered; batteries not required.
- Allows for PEEP attachment.
- Meets ASTM, ISO and KKK-1822C standards.
|
Content | Pneupac babyPAC Ventilator
babyPAC is specially designed to deliver ventilation to small, fragile lungs of patients ranging from neonates through pediatrics up to 20kg with precision and confidence. It has a sophisticated range of ventilation controls including CPAP, variable I:E ratio and variable oxygen concentration. The babyPAC also incorporates a comprehensive range of alarms.Features and Benefits- Unique variable oxygen concentration gas mixing system
- Inspiratory pressure control
- Separate controls for inspiratory and expiratory time
- Four operating modes
- PEEP/CPAP control
- Adjustable pneumatic pressure relief with audible alarm
- Integrated pressure monitoring/alarm system
- Low gas supply indicators for O2 and air
- Complete pneumatic operation
- Lightweight and durable
- MR Conditional: 3 Tesla actively shielded magnet
- max gradient of 430 G/cm, 0.82 W/kg at 125.5 Mhz
Warranty Information
Features of the Pneupac babyPAC Ventilator System:babyPAC is specially designed to deliver ventilation to small, fragile lungs of patients ranging from neonates through pediatrics up to 20kg with precision and confidence.
It has a sophisticated range of ventilation controls including CPAP, variable I:E ratio and variable oxygen concentration. The latter is particularly important in neonatal intensive care and transport since high oxygen concentrations over a prolonged period can be harmful.
The babyPAC also incorporates a comprehensive range of alarms. - Unique variable oxygen concentration gas mixing system
- Inspiratory pressure control
- Separate controls for inspiratory and expiratory time
- Adjustable pneumatic pressure relief with audible alarm
- Integrated pressure monitoring/alarm system
- MRI compatible up to 3 Tesla
- Low gas supply indicators for O2 and air
- Complete pneumatic operation
| Newport HT70 Plus Ventilator
The Newport HT70 plus ventilator combines ruggedness, ease of use, and clinical proficiency with exceptional mobility for patients from 5kg to adult. All models of the Newport HT70 plus ventilator family can be used for home care, transport, hospital, long-term care, and emergency preparedness, as well as for invasive or noninvasive ventilation.
In addition to its standard clinical features, the HT70 offers an on-airway flow sensor that provides expanded monitoring with alarms and the choice of flow or pressure trigger. With waveform graphics, an oxygen cylinder usage calculator, and an internal battery use time estimator, the HT70 plus ventilator goes beyond standard portable ventilation. - An on-airway flow sensor provides more choices for ventilation—inspiratory or expiratory monitoring and alarms, flow or pressure trigger.
- The hot-swappable battery provides up to 10 hours of operation (depending on settings). Batteries can be swapped out on the go for extended operation and added freedom without interrupting ventilation.
- The Battery Time Estimator provides added peace of mind during transports.
- Built-in oxygen monitoring and alarms alert users to changes or disruptions when using supplemental oxygen.
- The Cylinder Use Time Calculator helps estimate how long oxygen will last when on the go.
- The full-color touch screen provides easy access to all controls, simple navigation and a help guide for added convenience.
- With its rugged and reliable construction, the ventilator is designed to withstand rough treatment in a wide range of environments.
- A patented gas generator runs cool and quiet, is gas efficient and provides consistent volume delivery.
- Advanced features such as Alarm Quickset, custom presets and custom backup ventilation make this an exceptional portable ventilator.
HT70 Plus SpecificationsDimensions- Width: 9.75 in. (24.74 cm)
- Depth: 11 in. (27.94 cm)
- Height (includes handle): 10.25 in. (26.04 cm)
- Weight: 15.4 lbs (6.9 kg)
- Touchscreen: 5.2 in. (13.20 cm) X 3.9 in (9.90 cm)
- Nominal: 7 in. (17.78 cm) diagonal
Patient RangeControls/Settings- IModes (Pressure or volume): A/CMV, SIMV, SPONT
- NIV (Noninvasive ventilation): On/off in all modes
- VT (Tidal Volume): 50 to 2,200 mL
- RR (Respiratory Rate): 1 to 99 b /min
- i Time (Inspiratory Time): 0.1 to 3.0 sec
- PEEP/CPAP: 0 to 30 cm H2O/0 to 30 mbar
- PS (Pressure Support): 0 to 60 cm H2O/0 to 60 mbar*
- Flow: 6 to 100 L/min
- I:E Ratio: 1:99 to 3:1
- PC (Pressure Control): 5 to 60 cm H2O/5 to 60 mbar
- Ptrig (Sensitivity): -9.9 to 0 cm H2O/-9.9 to 0 mbar
- Flow Trigger: 0.0 to 10.0 L/min, Off
- Manual Inflation: 3 sec maximum
- O2 (oxygen): 21 to 100%
- Bias Flow: NIV off: 7 L/min w/PEEP
- NIV on: 3 to 30 L/min w/PEEP
- PS Max i time: 0.1 to 3.0 sec
- PS % Exp. Threshold: 5 to 85%
- Slope Rise: 1 to 10
- Flow Wave Pattern: Square or descending
- Auto Lock function: On/off
- Language Selection: Multiple language options
- *PEEP + PS cannot exceed 60 cm H2O/mbar
Monitored Parameters- Paw (Peak, Mean, Base): VTI / VTE (insp./exp. tidal volume)
- MVI/ MVE (insp./exp. minute volume): Peak Insp. Flow
- RR tot (total respiratory rate): Internal Dual Battery System
- O2 Concentration: I:E Ratio
- O2 Cylinder Use:Battery Use Time Estimator
Specialty Screens- Events: Records up to 1,000 events with parameter settings
- Trends: Displays trend graphs for last 72 hours
- Waveform Graphics: Flow/pressure/tidal volume
- Help: Touch any button for a tutorial of that feature
- Domains: Basic, transport and hospital
- Export Data: Capture/download events and trends
- Patient Presets: Customized or default
- Customized Back Up Ventilation: Link with apnea and/or low MV and customize settings
Alarms- High/Low Airway Pressure: Apnea
- High/Low Baseline Pressure: High/Low Oxygen
- High Resp. Rate: Low Battery
- High/Low Minute Volume: Alarm Silence/Reset
- Device Alert: Back-up Ventilation Alert
- High Tidal Volume: Airway Flow Sensor Disconnect
| AutoVent 2000/3000 Automatic Transport Ventilator
The first ventilator designed expressly for the EMS professional, the AutoVent 2000 provides independent controls for tidal volume and BPM. The AutoVent 3000; with additional inspiratory time settings; offers an even wider range of patient applications to meet most critical emergency care situations. Both models are designed to meet ventilator needs in a variety of applications, from intra– and inter-hospital transports to sophisticated air rescue. Automatic transport ventilators have been recommended by the American Hospital Association as the preferred equipment to provide ventilator support in the pre-hospital setting.The AutoVent 2000/3000 uses state-of-the-art pneumatics to assure reliable, time-cycled constant flow ventilation powered by a minimum of source gas. Both models may be used with all models of the LSP single patient use ventilation circuits as an added protection against patient cross-contamination.Each AutoVent is accompanied by the proven LSP patient valve with its bright green visual breath indicator, built-in audible pressure limit alarm, and intermittent mandatory ventilation providing gas flow for spontaneous breathing patients. The patient valve is available with an anti-inhalation valve for use in toxic environments.Features and Benefits- Small, compact, and transport ready.
- Designed to perform in harsh and toxic environments.
- Assembles quickly with simplified operating instructions printed on the case.
- Impact-resistant case with shock-absorbing bumpers and recessed control settings.
- Rate and volume settings independently operated.
- Easy-to-monitor patient valve assembly and toxic atmosphere valve are able to deliver additional breaths on demand by inspiratory effort of the patient.
- Operates exclusively on standard 50 psi source gas, eliminating air entrainment and maintaining the integrity of the specified oxygen concentration.
- Operates at extreme temperatures ranging from 0° F to 125° F.
- Pneumatically powered; batteries not required.
- Allows for PEEP attachment.
- Meets ASTM, ISO and KKK-1822C standards.
Technical Specifications
Control Modules:- Supply Pressure Range: 40-60 psig
- Operating Temperature: 0° F to 125° F
- Storage Temperature: -40° F to 160° F
- Frequency (AutoVent 2000): 8 to 20 BPM
- Frequency (AutoVent 3000): 8 to 28 BPM
- Tidal Volume (AutoVent 2000): 400 to 1200 ml.
- Tidal Volume (AutoVent 3000): 200 to 1200 ml.
- Flow Rate: 16 to 48 LPM
- Inspiratory Time (AutoVent 2000): approx. 1.5 or 2.0 seconds
- Inspiratory Time (AutoVent 3000): approx. .75, 1.5, or 2.0 seconds
- Expiatory Time: 1.5 to 6.0 seconds
- I:E Ratio: 1:1 to 1:4
- Weight: 24 o.z./680 g.]
- Dimensions: 6″ W x 1-3/4″ D x 3 1/2″ H
- Case Material: Polyester
- Input Connection: Plated Brass
- Output Connection: Plated Brass
- Minute Volume: 0 to 24 LPM
- Gas consumption: 0.5 lpm maximum
- Driving Gas: 0.5 LPM Maximum
Patient Value Assembly AutoVent 2000/3000 Automatic Transport Ventilator- Flow: As required in demand mode: 0-48 lpm at 50 psig
- Peak Inspiratory Flow: 48 lpm at an airway pressure drop of less than 2.5 cm H20
- Delivery Pressure: 60±5 CM H20
- (Insp.) Crack Pressure 0 to -2 CM H2O (0 to – .8 in. H2O)
- Exhalation Resistance:
- LPM: 0-10; cm H2O (max): 1.5
- LPM: 11-70; cm H2O (max): 3.8
- Gas Consumption Driving Gas: 0.5 lpm maximum
- Dead Space: 8 ml (excluding mask)
- Supply Pressure: 40° to 60° psig
- Operating Temperature 0° F to 125° F
- Storage Temperature: -40° F to 125° F
- Inlet Fitting: standard male oxygen DISS
- Filter: 25 micron stainless steel mesh
- Outlet: 22 mm outside diameter x 15 mm inside diameter; fits standard medical masks, endotracheal tubes, and tracheostomy tubes
- Weight: 16 oz (450 grams)
- Materials: body – anodized aluminum; cover – polycarbonate; outlet fitting – polycarbonate; inlet fitting – plated brass
|
Reviews
There are no reviews yet.