| Description | The i500 intraoral scanner, exemplifies three qualities:
Value, Efficiency, and ProductivityPerfect software and hardware combination:
Value, Efficiency, and ProductivityOne Software to connect them all | CIRRUS HD-OCT 5000 is configured with the highest resolution visualization capabilities and sophisticated clinical applications such as Advanced RPE analysis to track retinal pigment epithelial integrity and Ganglion Cell Analysis to assess glaucomatous loss in the macula that may not be evident in the peripapillary region. The new FastTrac retinal tracking reduces eye motion artifacts without sacrificing patient throughput with a proprietary scan acquisition strategy, high speed 20 Hz LSO camera, and single-pass alignment scanning. This feature enables the highest resolution B-Scans to be captured in identical locations from visit to visit providing precise assessment of change in targeted pathologies. | InMode Aesthetics InmodeRF BodyTite with BodyTite and FaceTite ApplicatorsBenefits
Controls heating to ensure that large volume contraction is consistent, avoiding overtreated or undertreated area
When treating different areas of the body, the operator is always receiving real time temperature monitoring, even in deep fat areas where laser temperature readers cannot reach
Allows focal treatment of all body areas with large volume
Treats deep fat, up to 50 mm (2 inches) | Deka Synchro Replay Laser Nd-Yag Standard Handpieces – More than 10 selectable handpieces
– Different spotsizes available (2.5 – 24 mm)– Automatic spot recognition system– Ergonomic connector for air-cooling devices | The image can then be displayed on a monitor, helping you to educate your patients The HRK can provide peripheral keratometry measurement data which is very useful when fitting contact lenses. The eye can be displayed in full colour mode on a tilting touch screen which enables you to see the patient’s contact lens fitting status, previously only possible using a slit lamp. As the HRK has the world’s first contact lens fitting function in an auto keratometer, you can now see the flourescein liquid with blue illumination along with automatic calculation and recommendation for contact lens fitting. | Treatments offered with the InMode OptimasMorpheus8- Skin Resurfacing and RejuvenationLumecca IPL – Age spot and sun spot treatmentForma – Skin remodeling at its bestAvailable Handpieces:
LUMECCA
FORMA
FRACTORA
DIOLAZEXL
VASCULAZE
VLAZE
MORPHEUS8LUMECCA
Fastest IPL Results*
*Clearance in 1-2 sessions, compared to 4-5 sessions with competing devices |
| Content | Medit i500 Intraoral ScannerOur Intraoral Scanner Delivers: Value, Efficiency, and Productivity
Together, these three qualities make it easy to incorporate our intraoral scanner into your workflow. Designed with quality in mind, we created the i500 to add value to your practice. Regardless of specialization the i500 ensures that professional needs are met, workflows are optimized, and flexibility is guaranteed.High ROI
An unparalleled performance combined with a competitive price delivers exceptionally fast return on investmentFlexibility
An open system for integrated CAD/CAM workflow allows for the export of STL files for easy file transfer and thus optimized collaborationImpressive Speed
Intelligent scan-detecting algorithm with two high-speed cameras for quick and efficient intraoral scanningPowderless
No need for powder in most regular cases, allowing for a seamless scanning process and increased patient comfortHigh Accuracy
Single crown* :Trueness (Accuracy) = 5.1 μm (±0.49 μm)
Precision (Consistency) = 3.2 μm (±0.74 μm)*Single crown accuracy test was conducted by Medit according to the methods in “Evaluation of the Accuracy of Six Intraoral Scanning Devices: An in-vitro Investigation. ADA Professional Product”
SPECIFICATION | Tip | 18 x 15.2 mm (WxH) | | Overall handpiece length | 266 mm | | Weight | 276g | | Imaging technology | 3D-in-motion video technology | | Color | 3D full color streaming capture | | Connectivity | USB 3.0 | | Scanning FOV | 14 x 13 mm |
The Medit i500 intraoral scanner delivers efficiency, productivity, and affordability.This scanner has been designed with quality in mind to add value to your practice. With its fast speed and powderless system, it allows for a smoother, more efficient scanning experience.The Medit Link software and hardware with workflow management and communication software will enhance and support your everyday CAD performance. Completed with integrated cloud storage and open data architecture. - Scanning for iOS in real time
- High-speed continuous scanning
- Color structure of the surface in the resolution of Full HD 3D
- Quick scan
- Natural color transfer
- Capturing UHD images (SR virtual viewer)
- Real-time 3D visualization (15 FPS 3D Data)
- Without using a spray
- Diagnostic image 2D
- Open file format (.stl)
- Scanner with the smallest size of the scanning module
| Carl Zeiss Cirrus HD-OCT 5000 Smart Advanced Topography HDAdvancing Smart OCTfor Anterior Segment, Glaucoma and Retina- Anterior Segment Premier Module
- PanoMap Wide-Field Display
- Smart HD Scans
- En face report
Visualization at the speed of CIRRUSAnalyzing a single pathology from multiple views provides comprehensive insight and analysis of the clinical situation. How this helps you: - Spot small areas of pathology. Tightly spaced B-scans, (either 30 or 47 μm apart), in the cube ensure that small areas of pathology are imaged. For reference, a human hair is about 40-120 μm in diameter.
- Visualize the fovea. Scans that are spaced further apart than in the CIRRUS cube may miss the central fovea.
- Fuel for analysis. Millions of data points from the cube are fed into the Zeiss proprietary algorithms for accurate segmentation, reproducible measurements and registration for change analysis.
- Take the pressure off the operator. As long as the scan is placed in the vicinity of the fovea or optic nerve, the software automatically centers the measurements after the capture.
- See the tissue from different perspectives. View the cube data from all angles, with 3D rendering, OCT fundus images and Advanced Visualization™.
- Future ready. Previously captured CIRRUS cubes can be analyzed using new analyses.
Tracking at the speed of CIRRUSFastTrac™ reduces eye motion artifacts without sacrificing patient throughput with a proprietary scan acquisition strategy, high speed 20 Hz LSO camera, and single-pass alignment scanning
With FastTrac, scan at the highest resolution at the same location at each visit. Assessment at the speed of CIRRUSMeasurement centering with FoveaFinder and AutoCenterOn the macula, the unique FoveaFinder technology ensures the ETDRS and ganglion cell plus inner plexiform layer measurement frameworks are centered on the fovea.AutoCenter™ function automatically centers the 3.4 mm diameter peripapillary RNFL calculation circle around the disc for precise placement and repeatable registration. The placement of the circle is not operator dependent. Accuracy, registration and reproducibility are assured. Manage at the speed of CIRRUS Carl Zeiss Cirrus HD-OCT 5000 Smart Advanced Topography HDGuided Progression Analysis (GPA™) for Assessing RNFL and Optic Disc ChangeGPA™ compares RNFL thickness and optic disc measurements over time and determines if statistically significant change has occurred.Focal Progression Analysis – Up to 6 progression maps are compared to two baselines. Areas of statistically significant change are color-coded yellow when first noted and then red when the change is sustained over consecutive visits.
Trend Analysis with Rate of Change – RNFL thickness values are plotted over time. Trends are calculated and confidence intervals are shaded when rate of change is statistically significant.
| INMODE Bodytite Laser – Radio Frequency (RF)BodyTite
Cannula Length:17 cm
Cannula Diameter:2.2 mm
Depth of Treatment:Up to 50 mm (2)
Internal Temperature:Operator adjustable between 50°C – 70°C
External Temperature:Operator adjustable up to 42°C
Output Temperature:1 MHz+
FaceTite
Cannula Length:10 cm
Cannula Diameter:1.3 mm
Depth of Treatment:Up to 25 mm (1″)
Internal Temperature:Operator adjustable between 50°C 70°C
External Temperature:Operator adjustable up to 42°C
Output Frequency:1 MHzBodyTite WorkstationMinimally Invasive Radio-Frequency Assisted Lipolysis (RFAL) Surgical Results Without the Scars.BodyTite is InModes latest minimally-invasive body contouring procedure that provides superior internal and external lipolysis, delivering results only achieved through more extensive excisional surgical procedures. BodyTite is powered by RFAL (Radio-Frequency Assisted Lipolysis) resulting in three-dimensional remodeling.BodyTite provides doctors with a tool to perform arm lifts without excisions, breast lifts without the lollipop scar and contour areas of non-adherence with results previously only achieved through more extensive surgical procedures.Benefits
Controls heating to ensure that large volume contraction is consistent, avoiding overtreated or undertreated area
When treating different areas of the body, the operator is always receiving real time temperature monitoring, even in deep fat areas where laser temperature readers cannot reach
Allows focal treatment of all body areas with large volume
Treats deep fat, up to 50 mm (2 inches)PATIENT BENEFITS
Patients today want to avoid surgery when possible. With BodyTite and FaceTite, your patients can reduce fat without leaving behind saggy, wrinkly skin. They are left with surgical-like results with no scars, less downtime and long-lasting, beautiful results.PRACTICE BENEFITS
Adopting RFAL with three-dimensional skin contraction can help innovate your practice. Leveraging BodyTite and FaceTite for your practice allows you to add a suite of minimally invasive procedures that contours and lifts abdominal, breast, face, neck, arm, thigh and knee tissue.FaceTite
HOW DOES IT WORK
FaceTite is a minimally-invasive contouring solution for the face and small areas of the body. Physicians can achieve results similar to a facelift or brachioplasty without excisional surgery. This is a safe, effective and exciting treatment that offers patients significant aesthetic changes.FaceTite is powered by RFAL (Radio-Frequency Assisted Lipolysis) and provides superior internal and external lipolysis, resulting in three-dimensional remodeling of the fibrous septa. Built-in safeguards including real time measurements of skin temperature, impedance monitoring, power cut-off and audible feedback help ensure patient safetyBenefits INMODE Bodytite Laser – Radio Frequency (RF)
Uniform thermal field provides an even distribution of heat.
Dual temperature technologies provide greater safety and control compared to other technologies.
100% energy concentration in the treatment zone.
Physician sets and controls the temperatures. Heat gradient enables optimal treatment results.AccuTite
ACCURACY IS EVERYTHING
PRECISION TARGETING AND PROVEN PERFORMANCE
ACCURACY IS EVERYTHING
The new AccuTite makes focal RF contraction without excisional surgery the new standard in cosmetic medicine. Small, but mighty, the AccuTite delivers precision heating in addition to the science and safety recognized with the Radio-Frequency Assisted Lipolysis (RFAL) family of technologies.
FOR FACE AND BODY
FACEBrow
Periorbital
Nasolabial Fold
Lower Face
Neck
BODYAxilla Bra Fat
Upper Arms
Hands
Abdomen Etching
Inner Thigh
Knees
Womens Health & WellnessSIMPLE, SAFE & FOCUSED
The AccuTite is the smallest minimally-invasive radio-frequency contraction device with the most number of clinical studies and peer-reviewed publications backing its safety and efficacy. Patients who need precision fat reduction or skin contraction now have a new solution that can be done under local anesthesia, in an office setting, in less than 20 minutes, without excisional surgery. | Deka Synchro Replay Laser Nd-Yag Inside Moveo Innovation Moveo HR: Focus on Hair Removal
The multiple passes of Moveo HR over small defined areas cause gradual heating and destruction of unwanted hairs.
Moveo PL: Focus on Pigmented Lesions
The new MOVEO PL is indicated for skin age and sun spots progressively heating the pigmentedMoveo SR: Focus on Skin Rejuvenation
The multipass controlled action of MOVEO SR causes a progressive increase in heat at the dermal level, which stimulates a neocollagenic process.Moveo VL: Focus on Vascular Lesions
The specific action of Moveo VL acts directly and effectively on vascular redness.The versatile FT lamp can be added to the system at any time, enhancing the user’s ability to treat superficial Vascular and Pigmented Lesions.The FT pulsed light has ten different filters divided in five spectra of emission (500-520-550-600-650nm) and two spot areas. This flexibility is useful to adapt the emitted light to the patient skin type, application and treatment area.Deka Synchro Replay Laser Nd-Yag Standard Handpieces – More than 10 selectable handpieces
– Different spotsizes available (2.5 – 24 mm)– Automatic spot recognition system– Ergonomic connector for air-cooling devicesDeka Synchro Replay Laser Nd-Yag
Wavelength: 1064 nm
Pulse Energy: 120 J (max)
Pulse Lenght: 0.2 ms to 300 ms
Frequency Single Pulse: 10Hz (max)
Spot Diameter: 20mm, 15mm, 10mm, 7mm, 5mm, 2.5mm
Emission Spectrum: 500-950 nm and 650-950 nmTo Include:
1 x Foot Switch
1 x Key
1 x Module UPL Handpiece
6 x Deka Laser Handpieces
1 x ManualInside Moveo InnovationMoveo HR: Focus on Hair Removal
The multiple passes of Moveo HR over small defined areas cause gradual heating and destruction of unwanted hairs.
Moveo PL: Focus on Pigmented Lesions
The new MOVEO PL is indicated for skin age and sun spots progressively heating the pigmented lesions.Moveo SR: Focus on Skin Rejuvenation
The multipass controlled action of MOVEO SR causes a progressive increase in heat at the dermal level, which stimulates a neocollagenic process.Moveo VL: Focus on Vascular Lesions
The specific action of Moveo VL acts directly and effectively on vascular redness. | Huvitz HRK-8000A Auto Refractor KeratometerHuvitz Auto Ref – Keratometer HRK-8000A- Touch and tilting 7″ LCD Screen that allows for free and smooth tilting for viewing at any angle.
- Optimized Optical System
- Micro Lens Array
- Aberration Measurement which also can be displayed in a graphical Zernike Refraction Map
- PSF & Image Simulation
- Colour View Mode
- Peripheral Keratometry Measurement
- Ultra High Precision KER Data
- Contact Lens Fitting Assistance Guide
- Contact Lens Prescription Guide
- Auto Tracking
- Animated Guide
- Faster Measurement Speed
- Quiet and speedy auto cutting printer
- More data on aberration measurement
With its extreme precision and accuracy, the HRK8000A uses the most advanced wavefront technology to measure the light reflected from the retina and helps you to diagnose any refractive error. With a micro lens array developed by Huvitz, the HRK creates a number of focal points, the pattern of which can give a valuable insight into the patients ocular system. The HRK not only displays the conventional data such as spherical, cylinder and axis, the high order aberration data is displayed in a graphical Zernike refractive map, giving you a deeper understanding of your patient’s eyes.Optimized Optical System Huvitz HRK-8000A Auto Refractor Keratometer
A wavefront is a physical representation of the optical quality of a light beam. Using various methods, aberrometers map how light rays travel through the eye. The HR-8000A is engineered according to the Hartmann-Shack wavefront measurement technique, which is widely preferred for its speed and repeatability.Touch & Tilting Color Display Screen
A bright, high contrast 7″ VGA color TFT LCD screen provides high resolution video images. A smooth, free tilting function also offers you a comfortable and clear view at any angle.The image can then be displayed on a monitor, helping you to educate your patients The HRK can provide peripheral keratometry measurement data which is very useful when fitting contact lenses. The eye can be displayed in full colour mode on a tilting touch screen which enables you to see the patient’s contact lens fitting status, previously only possible using a slit lamp. As the HRK has the world’s first contact lens fitting function in an auto keratometer, you can now see the flourescein liquid with blue illumination along with automatic calculation and recommendation for contact lens fitting. | Inmode Aesthetics Optimas with Lumecca 515 & 580LUMECCA
SR515
Spot size:10x30mm
Pulse Repetition:1pps at all energies
Wavelength:515-1200nm
Fluence:10-30J/cm2
Peak Power:High Peak Power
Pulse Duration:Short/Long
Cooling:Controlled
SR580
Technology:IPL
Spot size:10x30mm
Pulse Repetition:1pps at all energies
Wavelength:580-1200nm
Fluence:10-30J/cm2
Peak Power:High Peak Power
Pulse Duration:Short/Long
Cooling:Controlled
FORMA
RF Output Frequency: Up to 65 W
Output Frequency: 1 MHz
Temperature Cut-Off: Real time temperature measurements set by operator up to 43°C
FRACTORA
24 Pin:Type – Full Thickness Dermal; Configuration – 6×4; Pin Length – 3000u; Ablation Depth – 3 mm; Heating Depth – Between 3-5 mm; Max Output Energy 62 mj/pin; Output Frequency – 1 MHz; Repetition Rate – Up to 2 pps
24 Pin Coated:Type – Deep and Subdermal; Configuration – 6 x 4 Coated; Pin Length – 3000 u, Ablation Depth – 3 plus mm; Heating Depth – Between 3-5 mm; Max Output Energy 62 mj/pin; Output Frequency – 1 MHz; Repetition Rate – Up to 2 pps
60 Pin:Type – Mid Dermal; Configuration – 10×6; Pin Length – 600u; Ablation Depth – 0.6-1 mm; Heating Depth – Between 3-5mm; Max Output Energy 62 mj/pin; Output Frequency – 1 MHz; Repetition Rate – Up to 2 pps
DIOLAZEXL
Laser Wavelength:810 nm (diode)
Spot Size:12mm x 26 mm
Fluence:Up to 40 J/cm2
Pulse Duration:Short/Long
Light Cooling Guide:2-15°C
Repetition Rate:Single and Auto-Repeat
VASCULAZE
Laser Wavelength:1064 nm (diode)
Spot Size:3mm x 4mm
Fluence:40-300 J/cm2
Pulse Duration:5-100 msec
Light Cooling Guide:7-12° C
VLAZE
Laser Wavelength:1064 nm (yag)
Spot Size: 4 mm x 5 mm
Fluence: Up to 300 J/cm2
Pulse Duration: 5 ms 25 ms
MORPHEUS8
Type:Deep and Subdermal
Pin Length:4000
Ablation Depth:5mm +
Max Energy:62 mJ/pin at 75 W
Frequency:1 MHz
Repetition Rate:Up to 2 pps
A FULL BEAUTY SUITE
Optimas will help you optimize results for your patients and your businessProfessional grade aesthetic procedures – Optimas is a great suite of innovations in one workstation to help you achieve your goals. The Optimas full beauty suite has state-of-the-art light, laser, and radiofrequency devices for skin care and hair removal.Available Handpieces : Inmode Aesthetics Optimas with Lumecca 515 & 580
LUMECCA
FORMA
FRACTORA
DIOLAZEXL
VASCULAZE
VLAZE
MORPHEUS8LUMECCA
Fastest IPL Results*
*Clearance in 1-2 sessions, compared to 4-5 sessions with competing devicesLumecca is a breakthrough intense pulsed light (IPL) that delivers up to 3X more energy in the 500-600 nm range to improve efficacy for vascular and pigmented lesions. It is optimized for clinicians to treat a variety of skin types and conditions with just a single session.SR515 – Removal of Pigmented Lesions on Light Skin, Removal of Superficial Vascular Lesions
SR580 – Removal of Pigmented Lesions on DARK SkiN, Removal of DEEP Vascular Lesions, Removal of Vascular Lesions on DARK SkinFORMA
Face Remodeling.
Stimulates the formation of new collagen and improves the skin’s elasticity for long-lasting and remarkable resultsForma is the first auto-adjusting, non-invasive, thermal skin treatment for deep and uniform tissue stimulation. Forma uses radio-frequency power that flows uniformly between the electrodes to provide a comfortable thermal experience with immediate and subsequent contraction. There is no downtime in this effective lunch-time procedure that will make anyone look years younger!Acquire: Forma has a temperature sensor built into the hand piece which reads skin surface temperature 1000 times per second, allowing clinicians to acquire skin temperature in real time.
Control: Software algorithm allows unprecedented safety of RF delivery. The cut off temperature” feature reduces RF energy automatically when the hand piece senses that the required skin temperature has been reached.
Extend: Clinical evidence suggests prolonged exposure to temperature above 40°C is advantageous for optimal clinical outcomes. Only InMode’s A.C.E. technology allows you to utilize therapeutic temperatures safely and efficiently.FRACTORA Inmode Aesthetics Optimas with Lumecca 515 & 580
Radio Frequency MicroNeedling.
Fractora is a fractional skin resurfacing and subdermal tissue coagulation device that bridges the gap between fractional lasers and surgical procedures. Clinical papers demonstrate outcomes such as: improvement in skin complexion, reduction in skin irregularities and restoring skin to a more youthful appearance. This all occurs within one session or multiple sessions, depending on patient preference. Fractora can be used on active cystic acne and acne scars.Addresses multiple problems, including treatment of wrinkles with fractional coagulation and ablation.
Significant resolution of cystic acne and scars (improving acne scarring by 50%).
Safe on skin type VI with little risk of post inflammatory hyperpigmentation (PIH) which is common with other resurfacing methods.
Combination of fractional coagulation and volumetric heating through tips with various depths and pin density configurations.High efficiency of vascular and pigmented lesions due to high peak power and optimized output.
Complete photo rejuvenation in 1 or 2 treatments versus 4-6 treatments with standard IPLs.
Reduces treatment time thanks to large spot size and high pulse repetition rate.
Strong sapphire cooling tip results in painless procedure.
Fast pulse repetition rate at all settings. Highest peak power 3300W*DIOLAZEXL
Diode Hair Removal.
Gold Standard Diode Hair Removal Without Compromising Peak Power, Speed and Large Spot SizeDiolazeXL is the most effective at combining high peak power and a large spot size simultaneously in the same session. Clinicians can benefit from this first and only combination of speed, efficacy, safety and comfort to optimize their hair removal revenue.Gold standard wavelength, pulsing and power for optimal results and maximal safety.
Reduction in clinician treatment time – Powerful enough to target and treat even the most stubborn hair.
Virtually painless due to strong built in cooling.
Can treat up to skin type VI.VASCULAZE
Vascular Lesion Removal.
Get the ultimate in vascular resolution with a fast and chilled leg and facial vein treatmentVascular lesions (including angiomas, telangiectasias, port wine stains and leg veins) can be treated with the Vasculaze. The Vasculaze is optimized with high peak power that targets appropriate hemoglobin, so patients can benefit from a fast and safe treatment.Narrow and ergonomic spot size is optimized for vascular lesion treatment. High peak power. Strong contact cooling. No disposables and consumables.VLAZE
Vascular Lesion Removal.
Fast, powerful and ergonomic laser device. Treats vascular lesions such as veins, spider veins and port wine stains safely, comfortably and effectively on all skin types from very light to darker skin tones.MORPHEUS8
THE FIRST FULL BODY FRACTIONATED TECHNOLOGY
Fractional Remodeling and Contouring At Its BestThe Morpheus8 is a new subdermal adipose remodeling device (SARD) that fractionally remodels and contours the face and body. Penetrating deep into the skin and fat, this morphs the aging face of body into a more desired smooth and sleek appearance, for all skin tones.Deep and safe fractional treatment penetrating 4000 microns with an additional thermal profile of 1000+ microns
Extremely uniform effect
Little to no thermal damage to dermis
Safe on skin type VI with little risk of post inflammatory hyperpigmentation (PIH) which is common with other resurfacing methods. |
Reviews
There are no reviews yet.