| Description | in combination of Spectra Mode and a carbon-based lotion, this soft laser peel feature is specifically designed to emit a quasi-long pulse of 300 microseconds to create photothermal energy to heat the skin’s thin layer of collagen and fibroblast, resulting in a younger and healthier looking. Together with consistent shot-to-shot stability, the VRM is a true workhorse for cosmetic treatments such as photo rejuvenation, non-ablative resurfacing, fine wrinkles, acne scars, and pore size reduction. | Includes:
1 Fractional Scanner Handpiece for Ablative Skin Resurfacing
1 Incisional Handpiece with up to or less than .2mm Spot Size
Handpiece Case
Distance Gauges
Footswitch
Patient Eyewear
Operator Eyewear
Operator Manual
Warning Sign | Laser Hair Removal
Details:- Serial Number: SQEAY-19M-XXXXX (message for serial number)
- System Total Shot Count: 560,693
- Alex Shot Count: 221,437
- YAG Shot Count: 339,256
Includes:- Handpiece and Delivery System
- Square Spot Sizes: 2x2mm, 3x3mm, 5x5mm, 10x10mm, 14x14mm, 18x18mm, 20x20mm, 24x24, 27x27mm
- Fiber Pole
- Foot Switch
- System Key
- Operators Manual
- 30 Day Parts and Labor Warranty
| The HydraFacial resurfacing procedure thoroughly cares for your skin, providing cleansing, exfoliation, extractions, and hydration, including Vortex-Fusion of antioxidants, peptides, and hyaluronic acid. The HydraFacial is a non-invasive, non-surgical procedure that delivers instant results with no discomfort or downtime. The procedure is immediately effective | Included Handpieces:
HS 22×35 mm Spot Size Diode Handpiece
XC 12×12 mm Spot Size Diode HandpieceAlso Includes:
Operator Manual
2 Pair Operator Eyewear
1 Pair Patient Eye Shields
2 Keys | Includes:
1x Fractional Scanner Handpiece
4x Brand New 120 Tips
2x Brand New 300 Tip
1x 1000 Tip
Footswitch
2 Keys
Operator Manual
1 Operator Eyewear
1 Patient Eyewear |
| Content | LUTRONIC SPECTRA VRM III TATTOO LASER
Laser Source:Nd:YAGWavelengths:532 nm, 1064 nm, 585 nm and 650 nm (dye handpieces)
Operating Mode:5-7 nanoseconds
Pulse Duration:Spectra mode = 300 microseconds
Maximum Energy:Q-switched mode = 1,000 mJ, Spectra mode = 1,500 mJ
Beam Profile:Top Hat (Uniform) Mode
Optical Delivery:Articulated arm
Aiming Beam:Diode 655 nm (Red) 1 mW, adjustable brightness
The Lutronic Spectra VRM is an award-winning laser system designed for use in a wide range of dermatological and aesthetic procedures. This powerful Q-switched Nd:YAG system is clinically effective for a variety of benign pigmented lesions, tattoos and more. Offering two distinct wavelengths at 1064nm and 532nm, the Spectra VRM (with optional solid dye handpieces) reliably removes even colored amateur, professional and traumatic tattoos with precision and ease. With the optional solid dye hand pieces, the VRM series can double its capacity in treating an assortment of tattoo inks.
A special feature of the VRM Series is the addition of the Lutronic “Spectra Mode” that extends the range of procedures that can be performed to include laser peeling, skin rejuvenation, wrinkle removal and melasma treatments.In combination of Spectra Mode and a carbon-based lotion, this soft laser peel feature is specifically designed to emit a quasi-long pulse of 300 microseconds to create photothermal energy to heat the skin’s thin layer of collagen and fibroblast, resulting in a younger and healthier looking. Together with consistent shot-to-shot stability, the VRM is a true workhorse for cosmetic treatments such as photo rejuvenation, non-ablative resurfacing, fine wrinkles, acne scars, and pore size reduction.Lutronic Spectra VRM III Tattoo Laser Includes:– System– Mast– Power Cable– Foot Switch– Key– Spectra Lotion– 2 Hand Piece Wooden Cases– Hand Pieces:— SD650nm Dye Handpiece— SD585nm Dye Handpiece (Gold)— Nd:YAG 1-7mm (Black, w/Cable)— Nd:YAG 7mm Handpiece (Red, w/Cable)– Smoke Handpiece– Operator’s Manual– Accessories (as shown) | EMVERA CLARO2 CO2 LASER
Claro2 Medical Laser System
The Claro2 laser technology offers the most innovative approach to laser treatments today. It provides an acceptable and comfortable procedure under little or no anesthesia with minimum pain from evaporation of the skin layers, resulting in minimal social or work downtime. The laser delivers a series of microscopic, closely-spaced laser spots to the skin while simultaneously preserving the normal, healthy skin. The undamaged skin becomes a reservoir of tissue for fast heating and regeneration of the treated area by producing and providing new dermal collagen and eliminating epidermal pigmentation and irregularities to the skin tone. The Claro2 laser system is specially designed to improve skin texture and tone, and fight wrinkles, scars and pigmentations. Since the treatment procedures are customized to patients skin, operators are able to adjust laser settings to tailor treatments and achieve superior results.Claro2 Laser Features Provide:
Unparalleled char-free ablation, vaporization, excision, or incision of soft tissues
Reduced thermal damage to surrounding tissues
Rapid healing and minimal downtime
Stimulation of deeper collagen with high pulse energy
Large TFT LCD touch screen provides easy operation with the latest high speed microprocessor technology
Adjustable scanning patterns and sizes
Adjustable intensity of pilot beam
Adjustable pulse duration
Last treatment setting memorization
Automatic alarm system for operation and errors
No consumable costsIncludes:
1 Fractional Scanner Handpiece for Ablative Skin Resurfacing
1 Incisional Handpiece with up to or less than .2mm Spot Size
Handpiece Case
Distance Gauges
Footswitch
Patient Eyewear
Operator Eyewear
Operator Manual
Warning SignLaser Type:Sealed of Co2 Laser
Wavelength:10.6 um
Mode Structure:TEM00
Max Power:0-30W (adjustable)
Spot Size:Equal to or less than .2mm
Aiming Beam:630nm Red Laser (Adjustable Brightness)
Delivery System:Articulated Arm
Operation Modes:Continuous Wave, Single Pulse, Repetition Pulse, Super Pulse, Scanner
Pulse Width:Single Pulse (0.01-1s); Repetition Pulse (0.001-1s); Scanner (0.0001-0.01s)
Scan Size: Adjustable
Scan Pattern:Oval, Triangle, Rectangle, Line
Scan Array Density:Adjustable
Cooling System:Self-Contained, Closed Cycle
Power Supply:100-120V AC, 50/60Hz or 200-240V AC, 50/60Hz
Environment Temperature:10-40 Degrees Celsius
Relative Humidity:Below 80%
Dimensions:561mm x 500mm x 1443mm
Weight:42kgApplications Include:EMVERA CLARO2 CO2 LASERDermatology, Plastic Surgery and General Surgery procedures including but not limited to:
Laser skin resurfacing
Treatment of furrows and wrinkles
Removal of skin tags, actinic keratosis, acne scars, keloids, tattoos, telangiectasia, squamous and basel cell carcinoma, warts and uneven pigmentation
Treatment of cysts, abscesses, hemorrhoids and other soft tissue applications
Blepharoplasty
Site preparation for hair transplantsOtorhinolaryngology (ENT) procedures including but not limited to:
Treatment of leukoplakia of larynx, nasal obstruction, rhinophyma, verrucrea vulgares, choanal atresia, rhinophyma, LAUP and papillomatosis polypsGynecology:
Treatment of condyloma acuminate, cervical
intraepithelial neoplasia, leukoplakia and vulvar/
vaginal intraepithelial neoplasia, cervical dysplasia
Podiatry procedures including but not limited to:
Ablation, vaporization and excision of soft
tissue lesions such as ingrown nail, fungal nail,
porokcratoma, matrixectomy and verrucae vulgares | 2019 Lumenis Splendor X- Laser Hair Removal
Lumenis Splendor X Laser Hair RemovalThe Alexandrite wavelength at 755 nm, which is ideal for treating skin tones 1, 2 and 3 (fair and light skin tones). It is highly absorbed in melanin and is therefore not safe for use on darker skin tones.
The Nd:YAG wavelength at 1064 nm, which is ideal for treating skin tones 4, 5 and 6 (4 being tanned skin and 5 and 6 darker skin tones) as the absorption by melanin is much lower than with the Alexandrite wavelengthThe Lumenis Splendor X has been introduced to be a player in the solid state Nd:YAG and Alexandrite laser hair removal market. The gold standard for hair removal has always been considered Alexandrite 755nm for light skins and Nd:YAG 1064nm for dark skins.The Lumenis Splendor X combines both in a unique way with blended emission.Instead of firing a single wavelength at a time the Splendor X allows you to fire both wavelengths simultaneous in adjustable amounts to suit the skin type and hair types. This means you are target multiple chromophores at any given time given enhanced results across the board.The Lumenis Splendor X also allows the user to choose between square and round spot sizes with large spot sizesLumenis Splendor X Laser Hair RemovalThe Alexandrite wavelength at 755 nm, which is ideal for treating skin tones 1, 2 and 3 (fair and light skin tones). It is highly absorbed in melanin and is therefore not safe for use on darker skin tones.
The Nd:YAG wavelength at 1064 nm, which is ideal for treating skin tones 4, 5 and 6 (4 being tanned skin and 5 and 6 darker skin tones) as the absorption by melanin is much lower than with the Alexandrite wavelengthLaser Hair Removal
Details:2019 Lumenis Splendor X- Laser Hair Removal- Serial Number: SQEAY-19M-XXXXX (message for serial number)
- System Total Shot Count: 560,693
- Alex Shot Count: 221,437
- YAG Shot Count: 339,256
Includes:- Handpiece and Delivery System
- Square Spot Sizes: 2x2mm, 3x3mm, 5x5mm, 10x10mm, 14x14mm, 18x18mm, 20x20mm, 24x24, 27x27mm
- Fiber Pole
- Foot Switch
- System Key
- Operators Manual
- 30 Day Parts and Labor Warranty
| Edge Systems HydraFacial MD TowerTreatmentThe HydraFacial treatment merges soothing and invigorating spa therapies with advanced medical technology to achieve instant, lasting results. This innovative treatment provides results after just one visit!Skin Health EducationYour skin is the largest organ of your body.Everyday, your skin is exposed to free radicals – unstable molecules like pollution, sun, and stress which damage the vital skin cells like collagen and elastin that keep you looking fresh and young.One of the most damaging free radicals is the sun’s rays. UVA rays have the same strength, every day, all year long.Antioxidants counteract free radical damage by trapping and containing them, preventing further damage to skin cells.The HydraFacial utilizes some of the most powerful antioxidants to revitalize and protect your skin.Skin Health for Life is not just improving your appearance, but actually restoring youthful, healthy skin. Skin health is a lifestyle, requiring monthly maintenance and the right treatment for every skin type. That treatment is the HydraFacial.Works for all skin types- Shows immediate results
- No downtime or discomfort
- Target specific skin concerns
- Provides an alternative to invasive procedures
The process Edge Systems HydraFacial MD TowerStep 1. Cleansing and exfoliation: dead skin cells are removed to revieal healthly new skin.Step 2. Acid peel: this gentle peel helps loosen dirt and debris from pores without irritation.Step 3. Extractions: Painless, automated extractions use vortex suction to clean out pores.Step 4. Hydration: Antioxidants and Hyaluronic Acid are Vortex-Fused™ to nourish and protect.The HydraFacial resurfacing procedure thoroughly cares for your skin, providing cleansing, exfoliation, extractions, and hydration, including Vortex-Fusion of antioxidants, peptides, and hyaluronic acid. The HydraFacial is a non-invasive, non-surgical procedure that delivers instant results with no discomfort or downtime. The procedure is immediately effective | 2016 LUMENIS LIGHTSHEER DESIRE PERMANENT LASER HAIR REDUCTION2016 Lumenis Lightsheer Desire Permanent Laser Hair Reduction
Great clinical results begin with the LightSheer 805 nm diode laser empowered by two advanced technologies.The Gold Standard in Permanent Laser Hair Reduction
More and more people desire to have permanent hair reduction. They want a treatment that is effective, fast and comfortable. To meet these needs, Lumenis, a leader in laser and energy based technologies, developed the LightSheer DESIRE, the new generation of Laser Hair Reduction systems, so you can grow your business by offering your patients what they DESIRE. The Gold Standard in Permanent Laser Hair Reduction.Included Handpieces:
HS 22×35 mm Spot Size Diode Handpiece
XC 12×12 mm Spot Size Diode HandpieceAlso Includes:
Operator Manual
2 Pair Operator Eyewear
1 Pair Patient Eye Shields
2 KeysSuperior Performance
– Versatile 805nm diode laser
– 2 different Models to select from
– Multiple handpieces with various spot sizes
– 2 advanced technologies
– Upgradable features: add capabilities as your practice grows.Advanced Laser Hair Removal TechnologyGreat clinical results begin with the LightSheer 805 nm diode laser empowered by two advanced technologies:
1. Vacuum Assisted High-Speed Integrated Technology – A large 22×35 mm spot size enables the use of low-fluence and a unique mechanism for pain reduction which provides effective, fast and comfortable treatments for your clients.
2. ChillTip™ Technology – Integrated contact cooling provides epidermal protection for treatment areas requiring precision and higher fluence.Lightsheer Desire Specifications
High Speed (HS) Handpiece
Laser Type:Diode
Wavelength:805 nm
Spot Size:22 x 23 mm
Repetition Rate:Up to 3 Hz
Pulse Repetition:1-3 Pulses
Fluence:4.5-12 J/cm2
Pulse Width:30-400 ms
Peak Power:2310 WXC Handpiece
Laser Type:Diode
Wavelength:805 nm
Spot Size:12 x 12 mm
Repetition Rate:Up to 3 Hz
Pulse Repetition:1 Pulse
Fluence:10-40 J/cm2
Pulse Width:5-400 ms
Peak Power:1920 WLightSheer® DESIREThe starting point to your successMore and more people desire to have permanent hair reduction. They want a treatment that is effective, fast and comfortable.To meet these needs, Lumenis, a leader in laser and energy based technologies, developed the LightSheer DESIRE, the new generation of Laser Hair Reduction system from the LightSheer Family of products, so you can grow your business by offering your patients what they DESIRE. | LUTRONIC ECO2 – ABLATIVE CO2 FRACTIONAL LASERLaser Type:Ablative Fractional Resurfacing (AFR)
Beam Delivery Method:Articulated Arm with Scanner or Convetional Handpiece
Medium & Method of Generation:Seall Off CO2 RF Mudule Laser
Wavelength:10,600 nm
CO2 RF Module Maximum Power: Maximum 30 Watt at Continuous Wave
Fractional Scanner Handpiece:
User Mode:Static (Stamping) / Dynamic (Air Brushing)
Tip:120, 300, 1000 um Spot Sizes
Pulse Energy:2 mJ – 240 mJ
Pulse Rate:10Hz to 200 Hz
Density:25 – 400 Spots / cm2
Scan Area:Max.14 x 14 mm
Scan Shapes:Square, Rectangle, Oval, Triangle, Point Beam
Normal Handpiece:
User Mode:Char Free (Ultra Pulse) / Super Pulse / CW
Pulse Rate:Char Free (Ultra Pulse) – 1 Hz to 700 Hz; Super Pulse – 1 Hz – 550 Hz
Pulse Width:Char Free (Ultra Pulse) – 40 us to 1000 us; Super Pulse – 1 ms – 5 ms
CW:ON Time – Cont. 0.01 s – 1.0 s
CW:OFF Time – SINGLE 0.001 s – 1.0 s
Adjustable Spot Size:0.2 – 1.0 mm
User Interface:Touch Screen with Flash Technology 7 inch LCD Screen
Dimensions EXCLUDES ARM: 360 mm (W) x 450 mm (L) x 1000 mm (H)
Dimensions WITH ARM: 360 mm (W) x 450 mm (L) x 1870 mm (H)
Weight:77 lbs. (35 kg)
Cooling:Air Cooling
Transform Your Practice with the Robust eCO2
Lutronics eCO2 is the premier fractional ablative laser that delivers the full spectrum of resurfacing treatments to your busy practice. You will appreciate how easy to use and reliable the system is while your patients rave about their outcomes.Includes:
1x Fractional Scanner Handpiece
4x Brand New 120 Tips
2x Brand New 300 Tip
1x 1000 Tip
Footswitch
2 Keys
Operator Manual
1 Operator Eyewear
1 Patient EyewearMINIMAL DOWNTIME & LESS DISCOMFORT
– Skin Tightening
– Wrinkles, Rhytids & Fine Lines
– Pigmented Lesions & Lentigines
– Scars
– Textural Irregularities
– Transepidermal Drug Delivery
– Dyschromia
– Solar/Actinic Elastosis
– Syringoma
– Vaporization, Incision & Excision CapabilitiesMINIMAL DOWNTIME, IMPROVED PATIENT COMFORT, INCREASED SAFETYThe Lutronic eCo2 – Ablative Co2 Fractional Laser features the patented Controlled Chaos Technology (CCT), an algorithm to pseudo-randomly deliver each micro laser beam and by placing maximum distance between sequential beams the system eliminates cross thermal diffusion between adjacent Micro-ablative Columns (MACs).This allows the tissue to maximize heat dissipation between shots. The result is an increased safety profile with a reduction in post-operative discomfort and faster healing time leading to unparalleled fractionalCCT reduces thermal damage by maximizing distance between laser micro-beamsQUICK-CHANGE TIPS WITH AUTO-RECOGNITIONFrom ultra-deep to superficial ablation, the eCO2 has the features you need to address a broad range of clinical conditions. The ultra-fast quick change tips come in a choice of three spot sizes, 120, 300 and 500 um, allowing you on-the-fly customized treatments. The eCO2s tip auto-recognition feature automatically changes treatment settings to adjust for the change in spot size. Combined together, the advanced technology, quick-change tips and safety features ensure the ultimate control for the best outcomes.WHY eCO2
Patients are attracted to low risk, minimal downtime treatments
Controlled Chaos Technology creates pseudo-random microwound patterns to minimize heat build-up, minimize downtime, increase safety and maximize patient comfort |
Reviews
There are no reviews yet.