| Description | The Dual Wavelength Solution that Delivers Suitable Parameters with an Incredible Fast Treatment SpeedLutronic CLARITY is a dual wavelength platform combining long pulsed 755 nm Alexandrite and 1064 nm Nd:YAG. CLARITY’s advanced features enable treatment versatility and greater speed. | INDICATIONS:
Pigmented Lesions
Uneven superficial pigmentation
Brown marks
Freckles and age spots
Vascular Lesions
Red spider veins,
Dilated Red Veins
Diffuse Redness
Rosacea
Sun Damaged Skin
Skin Rejuvenation
Improves Texture and Skin Tone
Improves Radiance
Skin laxity
Port Wine Stain (assessment by a doctor only) | Cutera Xeo LaserMultiple Technologies, Maximum FlexibilityIn today’s fast-paced aesthetic practices, maximum flexibility and upgradeability are paramount. Whatever your need, the Cutera Xeo Laser can provide the most versatile laser and light technologies on the market today. Whether you are interested in, Skin Fitness, hair removal, vascular therapies – or all the above – the Xeo can accommodate your specific needs through our upgradeable platform.The Cutera Xeo Laser combines the proven effectiveness of Cutera’s long-pulse Nd:YAG laser technology with the next generation of pulsed light treatments. The Cutera XEO can offer permanent hair reduction on all skin types, a complete range of vascular treatments and the next-generation in non-ablative combination skin therapy. | Deka Synchro Replay Laser Nd-Yag Standard Handpieces – More than 10 selectable handpieces
– Different spotsizes available (2.5 – 24 mm)– Automatic spot recognition system– Ergonomic connector for air-cooling devices | 2015 Active Optical Extra 818 IPL Hair Removal and Skin Rejuvenation; Excellent Cosmetic and Operating Condition, Very Lightly Used for Demonstrations Only, Single Owner; Included Handpieces and Pulse Counts: Hair Removal Handpiece = 6,617 Pulses, Facial Handpiece = 2,190, Life for Each Handpieces is 250,000 Pulses. | LOGIQ e Needle Recognition Software Option which helps provide precise and accurate display of the needle, anatomy and motion even in Color and Power Doppler. This feature harnesses pattern recognition technology that recognizes and accurately reveals the structure of a needle within the anatomy, without distortion of the needle and compromising the target. |
| Content | Lutronic Clarity Long Pulsed Alexandrite & Nd:YAG LaserRESULTS YOU CAN SEEThe ability to choose from 755 nm or 1064 nm wavelength provides your clinic a highly versatile system. The CLARITY uses proven technology with advanced features to provide visible results in a single treatment.ALEX Toning
InnerLift Technique
Genesis Technique
Dual Fractional Technique
COCO TechniqueSale – Lutronic Clarity Long Pulsed Alexandrite & Nd:YAG Laser MULTIPLE TREATMENT OPTIONSAPPLICATIONS Lutronic Clarity Long Pulsed Alexandrite & Nd:YAG LaserHair removal
Skin tightening & firming
Skin rejuvenation
Large pores
Blackheads
Pigmented lesions
Epidermal pigments
Vascular lesions
Facial telangiectasia
Flushing
Rosacea
Leg veins
Warts
Onychomycosis
And more…Lutronic Clarity Long Pulsed Alexandrite & Nd:YAG Laser with Dual Fractional Feature
The Dual Wavelength Solution that Delivers Suitable Parameters with an Incredible Fast Treatment SpeedLutronic CLARITY is a dual wavelength platform combining long pulsed 755 nm Alexandrite and 1064 nm Nd:YAG. CLARITY’s advanced features enable treatment versatility and greater speed.
SPEEDSale – Lutronic Clarity Long Pulsed Alexandrite & Nd:YAG LaserA high repetition rate and large treatment spot empower CLARITY users to permanently reduce unwanted hair with unprecedented speed, allowing clinics to perform more treatments and maximise their return on investment.
EFFICACYCLARITY’s highly efficacious treatment options are rooted in the delivery of high peak power laser energy, in short pulse widths. The Flat Top beam profile provides consistent treatment for more predictable outcomes.
VERSATILITYCLARITY’s dual wavelengths permits the treatment of all skin types and its advanced features provide multi-treatment opportunities enabling clinics to treat a larger range of applications; physicians may permanently reduce unwanted hair, improve the appearance of pigmented and vascular lesions, and rejuvenate the skin with multiple treatment options.“The worldwide 1st dual fractional feature by one handpiece supports a more reliable and gentle procedure.”
CONVENIENCESingle fiber delivery with 9 spot size choices ranging up to 20 mm with both wavelengths for ease of use, increased treatment speeds and reduced costs across multiple applications
Choice of epidermal protection and comfort with built-in Intelligent Cooling Device™(ICD) or air coolingHYBRID COOLINGHybrid Cooling (Optional), available on ICD model, provides optional dual cooling for added patient comfort. | 2017 CANDELA ELLIPSE NORDLYS IPL
Intense Pulsed Light in its simplest form is a way of saying short flashes of very bright light. The Nordlys Ellipse IPL uses short, safe bursts of carefully controlled filtered light which is emitted from a flash-lamp to treat specific skin conditions. For brown marks on the skin it targets melanin and for treatment of vascular problems it targets haemoglobin which causes the redness. In treating sun-damaged skin, both melanin and haemoglobin are treated.The amount of light and the speed of its delivery to your specific skin condition are exact and precisely controlled by Nordlys’ built-in computer. Unlike some other products on the market, this system carefully controls the pulse and the amount of energy delivered in the optimal waveband for the treatment. These factors explain why the best possible result is obtained. The Nordlys IPL has been clinically proven to be safe and effective.CLINICAL INDICATIONS:
Pigmented Lesions
Uneven superficial pigmentation
Brown marks
Freckles and age spots
Vascular Lesions
Red spider veins,
Dilated Red Veins
Diffuse Redness
Rosacea
Sun Damaged Skin
Skin Rejuvenation
Improves Texture and Skin Tone
Improves Radiance
Skin laxity
Port Wine Stain (assessment by a doctor only)2017 Candela Ellipse Nordlys IPLQUESTIONS & ANSWERS:
How does the treatment work?
An intense pulsed light is applied in a series of gentle pulses over the treatment area. Without damaging the skin, the light penetrates through the skin and is absorbed by the haemoglobin of the abnormally dilated capillaries or the melanin of the pigmented lesion. The heat causes the lesion to fragment and the dilated capillaries to close, the body then begins its natural healing process. The Nordlys Ellipse IPL stimulates fibroblast activity encouraging the formation of new collagen and elastin thereby improving the appearance of the fine lines and an overall skin texture.How long is each treatment?
Treatment varies from 15 to 45 minutes depending on the size of the area to be treated.How many treatments are needed?
The number of sessions recommended depends on the specific condition and the size of the area being treated. Your doctor or laser therapist will discuss this with you before treatments commence. For optimal results multiple treatments are sometimes recommended depending on your individual skin condition. Follow-up treatments may be recommended to maintain results.Is it painful?
Pain is minimal and most patients describe the sensation as being similar to the snap of an elastic band with some sensation of heat. Your doctor or laser therapist will always make sure of your comfort levels as the treatment is being administered.Are there possible side effects or risks involved?
The side-effects and risks are minimal if the treatment is performed by trained professionals who are experienced in this type of treatment. Immediately after the treatment the skin may appear flushed rather like a sunburn, brown pigmented spots may appear darker and capillaries may be visible. Swelling is usually minimal but it depends on the individual being treated.What results can I expect?
It helps to even out skin tone, improves the texture and gives the skin radiance
It helps to reverse the results of UV damage e.g. solar lentigines (brown marks) and telangiectasia (red veins)
It provides skin rejuvenation on the treated areas and helps to soften wrinkles
It enhances elasticity, it helps to firm the skin and reduce enlarged poresIs there anything I should avoid prior to treatment?
You cannot have this treatment if you have a tan so make sure your skin is as pale as possible for the best results.If you are on Roaccutane or any other Isotretinoin’s you will need permission from your Dermatologist before treatment commences. You should always have an assessment with your doctor or laser therapist prior to treatment to see if you are a suitable candidate.Which areas can be treated?
This treatment can be used for effectively treating and improving the appearance of the face, neck, décolleté and hands – however the neck and décolleté would require more treatments than the face.Your Dermatologist or Therapist can provide you with more information on whether the Nordlys Ellipse IPL is the right treatment for you. If you suffer from chronic pigmentation or chronic redness you will need to consult your Dermatologist before commencing with this | Cutera Xeo with Full Nd Yag and Low PulsesCutera Xeo Laser HandpiecesPearl Fractional Handpiece Features- Pearl Fractional has deep ablation and controlled thermal zone delivers maximum single-treatment results with less patient discomfort, downtime and risk than CO2
- Indicated for moderate to severe photoaging
- The 2790 nm wavelength (YSGG) controls thermal damage to maximize ablation while maintaining thermal stimulation and coagulation
- Controlled thermal zone minimizes risk of PIH and other complications
- Single treatment results are possible because our large 300 micron spot size ablates enough tissue in one pass
- Wound healing causes increased fibroblast activity and long term collagen deposition. Improvement is realized over six month period.
CoolGlide Nd Yag Laser Handpiece Features and SpecificationsThe CoolGlide laser is the first laser cleared for permanent hair reduction in all skin types.- Treat all skin types (I-VI) including tanned skin in the summer
- Patented PowerFlex™ technology provides fast treatments and high efficacy; allows independent control of fluence, pulse duration and repetition rates to tailor your treatment parameters
- Copper cooling provides the most efficient method of cooling for optimal skin protection and comfort
- Large spot size (10 mm) for maximum speed and optimal penetration at all follicle depths
- Wavelength: 1064 nm
- Fluence / Energy: Up to 300 J/cm2
- Spot Size: 3 mm, 5 mm, 7 mm, 10 mm
- Pulse Width: 0.1 – 30 msec or 10 – 100 msec
- Repetition Rate: 2 Hz to 10 Hz
Laser Genesis Handpiece FeaturesLaser Genesis is a staple of skin care for every doctor’s practice. It is a multi-purpose, all season, all skin type solution for overall skin health- Cutera Xeo Laser has a 1064 nm wavelength, combined with our patented microsecond technology, protects the epidermis, targets microvasculature and stimulates collagen production
- Improves wrinkles by gently heating the dermis; corrects diffuse redness, rosacea; smooths skin texture, shrinks pore size
- Peer reviewed journal shows evidence of erythema reduction and new collagen formation in the papillary dermis (Archives of Dermatology, Nov 2004)
- No downtime, minimal discomfort, no disposables.
LimeLight Handpiece Features and SpecificationsLimeLight is the most versatile, programmable device for treating vascular and pigmented lesions.- Three distinct preset programs (520-1100 nm) provide excellent hemoglobin and melanin absorption for uniform treatments and ease of use
- Clinical versatility permits treatment of multiple indications, including both low and high contrast pigmentation
- Features such as the industry’s fastest treatment speed and adjustable temperature control provide clinical versatility
- Only company with real-time calibration; this ensures accurate and consistent power output during treatment for reproducible results and patient safety
- Program A – 520 nm Filter – Fine Telangiectasia
- Program B – 560 nm Filter – Telangiectasia, Pigment
- Program C – 580 nm Filter – Solar Lentigines
- Spot Size: 10 mm x 30 mm
- Cooling: 5 °C, 10 °C or 20 °C
- Fluence / Energy: 5-30 J/cm2
- Repetition Rate: 2 Hz
AcuTip Handpiece FeaturesAcuTip delivers optimal results with targeted focal treatments of pigmented and vascular lesions–with no risk to surrounding skin.- Small tip allows aggressive pinpoint treatments – without compromising safety
- Selective wavelengths (500-635 nm) with short pulse durations deliver a powerful focal treatment
- Ideal for treatment of both low and high contrast pigmented lesions
- As powerful as Q-switched lasers for epidermal pigmentation; low risk of associated PIH
Pearl Handpiece FeaturesPearl delivers superior results in fewer treatments with less patient downtime than with non-fractional ablative lasers.- Indicated for fine wrinkles, dyschromia, skin tone and texture
- Full epidermal renewal is achieved with YSGG’s 2790 nm wavelength
- Patients receive 1-2 treatments without weeping and oozing and recover in 3-4 days
Excel Handpiece FeaturesThe first clinically effective long-pulsed Nd:YAG laser for both facial and lower extremity vascular lesions.- The Excel safely and effectively treats discrete vessels, high pressure vessels and deep veins
- Patented PowerFlex™ technology provides fast treatments and high efficacy; allows independent control of fluence, pulse duration and repetition rates to tailor your treatment parameters
- Contact copper cooling provides the most efficient method of cooling for optimal skin protection and comfort
- The “clearview” handpiece feature prevents vessel closure due to contact pressure
- Easy on-the-fly spot size adjustment (3, 5, 7 mm) facilitates optimal selection for safety and results
Titan V HP (small areas) + Titan XL HP (large areas) Handpieces Features and SpecificationsTitan is the most researched and peer-reviewed infra-red solution for deep dermal heating of all skin.- Titan’s light source generates energy from 1100 to 1800 nm for safe and effective volumetric heating of the dermis
- Titan candidates are often patients not yet ready for surgery
- When combined with other non-ablative procedures that improve conditions such as dyschromia, Titan’s toning effect enhances overall results
- Wavelength: 1100 – 1800 nm Infrared
- Fluence / Energy: 5 to 65 J/cm2
- Spot Size
- Titan V – 10 mm x 15 mm
- Titan XL – 10 mm x 30 mm
- Tx Cycle: 4 to 10 Seconds
ProWave Hair Removal Handpiece Features and SpecificationsProWave has multiple wavelength technology switches modes from Alexandrite to Diode to near Nd:YAG for maximum results, safety and versatility—all in a single high speed device.- ProWave (770-1100 nm), combines unrivaled treatment speed with optimal results and safety. Maximum versatility is achieved multiple wavelength technology enabling treatment modes from Alexandrite to Diode to near Nd:YAG
- Clinical studies showed > 80% hair reduction six months post three treatments
- Wavelength: 770 – 1100 nm
- Fluence: 5 to 35 J/cm2
- Spot Size: 10 mm x 30 mm
- Repetition Rate: 2 Hz
Cutera Xeo Laser System Specifications Cutera Xeo with Full Nd Yag and Low Pulses- Dimensions: 12″ W x 19″ D x 35″ H
- System Cooling: Internal, self-contained
- Electrical Info
- 115 V | 60 Hz | 20A
- 230 V | 60 Hz | 20A | 1 Phase
- Weight: 135 lbs
| Deka Synchro Replay Laser Nd-Yag Inside Moveo Innovation Moveo HR: Focus on Hair Removal
The multiple passes of Moveo HR over small defined areas cause gradual heating and destruction of unwanted hairs.
Moveo PL: Focus on Pigmented Lesions
The new MOVEO PL is indicated for skin age and sun spots progressively heating the pigmentedMoveo SR: Focus on Skin Rejuvenation
The multipass controlled action of MOVEO SR causes a progressive increase in heat at the dermal level, which stimulates a neocollagenic process.Moveo VL: Focus on Vascular Lesions
The specific action of Moveo VL acts directly and effectively on vascular redness.The versatile FT lamp can be added to the system at any time, enhancing the user’s ability to treat superficial Vascular and Pigmented Lesions.The FT pulsed light has ten different filters divided in five spectra of emission (500-520-550-600-650nm) and two spot areas. This flexibility is useful to adapt the emitted light to the patient skin type, application and treatment area.Deka Synchro Replay Laser Nd-Yag Standard Handpieces – More than 10 selectable handpieces
– Different spotsizes available (2.5 – 24 mm)– Automatic spot recognition system– Ergonomic connector for air-cooling devicesDeka Synchro Replay Laser Nd-Yag
Wavelength: 1064 nm
Pulse Energy: 120 J (max)
Pulse Lenght: 0.2 ms to 300 ms
Frequency Single Pulse: 10Hz (max)
Spot Diameter: 20mm, 15mm, 10mm, 7mm, 5mm, 2.5mm
Emission Spectrum: 500-950 nm and 650-950 nmTo Include:
1 x Foot Switch
1 x Key
1 x Module UPL Handpiece
6 x Deka Laser Handpieces
1 x ManualInside Moveo InnovationMoveo HR: Focus on Hair Removal
The multiple passes of Moveo HR over small defined areas cause gradual heating and destruction of unwanted hairs.
Moveo PL: Focus on Pigmented Lesions
The new MOVEO PL is indicated for skin age and sun spots progressively heating the pigmented lesions.Moveo SR: Focus on Skin Rejuvenation
The multipass controlled action of MOVEO SR causes a progressive increase in heat at the dermal level, which stimulates a neocollagenic process.Moveo VL: Focus on Vascular Lesions
The specific action of Moveo VL acts directly and effectively on vascular redness. | Active Optical Extra 818 IPL Hair Removal 2015Handpieces:Hair Removal Handpiece and Facial Handpiece
Chilled Tip:Up to 4c
Pulse Interval:0.5~2 Seconds
Output Power:11-31 joule/cm2, upto 4,000W
Cooling System:Revolutionary dual cooling
Control:Intuitive touch screen control
Lamp’s Life Span:250,000 Flashes (Universal), 200,000 Flashes (Facial)
Treatment Area:7.5 cm2 (15*50mm) Universal, 4.5 cm2 (15*30mm) Facial
Wavelength:420-1100 nm
Weight:42Kg (including Stand, if device is not a table top)
Dimensions:44cm x 45cm x 100cm Extra-818Skin Rejuvenation
Pigmentation Treatment
Acne Treatment
Hair Removal
Vascular (Facial) TreatmentThe Extra – 818 is the outcome of more than a decade of treatments and thousands of devices operated worldwide. It contains It contains unique features:
* Contemporary touch screen control
* Built-in Patch Test procedure for examining the optimal energy level
* A stunning number of 450,000 flashes in both lamps.The Extra – 818, based on Active’s GEM-PL technology, sets sets a specific Pulse Pattern according to the selected treatment type, skin color, skin photosensitivity and treatment depth.
The treatment protocols and different pulse patterns take into account the tissue’s TRT (Thermal Relaxation Time) and the combined knowledge accumulated from thousands of treatments done during the years and clinical investigations done to confirm the findings.The combination of tested treatment protocols with high end engineering makes the Extra – 818 the perfect device for leading clinics.Revolutionary Cooling System
The Extra – 818 has a dual cooling system, controlled and monitored in order to ensure long lifetime to the lamp and a comfortable treatment to the patient.Competitive cooling systems “freeze” the skin so that during the treatment the skin temperature will rise to a bearable level. However, this “freezing” temperature might limit the results because the follicles will not reach the coagulation temperature. To ensure optimal results Active installed a special Processor that prevents overcooling the skin and maintains a uniform low temperature of the “glass” throughout the treatment. This revolutionary system enables the Extra – 818 to provide best results with optimal patient comfort.Research Program Active Optical Extra 818 IPL Hair Removal 2015
For clinical investigations, the self setting program allows researchers to set the treatment’s parameters according to their needs. Allowing advanced research with the device.
The energy levels in the self setting program can reach 31Jcm2 with high intensity of 4,000W. | GE Logiq E R7 Portable Ultrasound Machine
The NextGen LOGIQ combines the high performance of a console system with the portability of a laptop. GE Healthcare’s compact system is designed for general imaging, musculoskeletal, anesthesiology, interventional, emergency, and critical care applications.It provides ultrasound imaging with precise anatomical detail at a variety of depths. The system includes innovative features that help simplify interventional procedures.LOGIQ e Needle Recognition Software Option which helps provide precise and accurate display of the needle, anatomy and motion even in Color and Power Doppler. This feature harnesses pattern recognition technology that recognizes and accurately reveals the structure of a needle within the anatomy, without distortion of the needle and compromising the target.Also includes the ability to adjust needle gain and angle.- Standard package includes AC power cord (USA)
- internet cord 3 meter in length CAT-5 type
- PC to HUB structure
- system software on USB
- Optional Function Key Label
- Ultrasound Transmission Gel .25L
- English Basic Service Manual CD and English User Guide and AIUM booklet.
The following scanning modes are included:- B-mode
- M-mode
- Anatomical M-mode
- Color flow mode
- Power Doppler imaging
- Pulsed wave Doppler and Ophthalmic
Features:The NextGen LOGIQ ecombines the high performance of a console system with the portability of a laptop. GE Healthcare’s compact system is designed for general imaging, musculoskeletal, anesthesiology, interventional, emergency, and critical care applications.Display Screen:- 15 in High-Resolution Color LCD
- Resolution: 1024 x 768
- Horizontal/Vertical viewing angle: +/-80 degree
- Brightness AdjustmentIntegrated Speakers
- Audio Volume Adjustment
- Interactive Dynamic Software Menu
Console Design:- Laptop Style
- Lithium Ion Battery
- Integrated Solid State Drive
- CPU – Intel Duo Core
- Operating System – Microsoft® Windows® 7
Console Interfaces:- DC Power Input
- USB 2.0 (3)
- LAN 10/100/1000 BaseT
- Docking Cart Connector
- HDMI
Standard Features:- Integrated Solid State Drive
- Automatic Optimization
- CrossXBeamTM
- Speckle Reduction Imaging (SRI-HD)
- Virtual Convex/Virtual Apex
- Fine Angle Steer
- HD Zoom (Write Zoom)
- Coded Harmonic Imaging (CHI)
- Raw Data Processing
- Quicksave
- On-board User Manual (Help)
- InSiteTM ExC capability
- Loop storage—from live scanning and from memory
- Patient Information Database
- Customizable User Interface
- Full M&A Calculation Package with Real Time Auto Doppler Calculations
- Vascular Calcs
- Cardiac Calcs
- OB Calcs and Tables
- Fetal Trending
- Multi Gestational Calcs
- Musculoskeletal and Hip Dysplasia Calcs
- Gynecological Calcs
- Urological Calcs
- Renal Calcs
- Small Parts Calcs
- Rheumatology Calcs
- Pediatric Calcs
- Report Writer Package
Software Options:- easy3D
- LOGIQ View
- Needle Recognition
- Stress Echo
- eSmart Trainer
- Auto IMT
- DICOM® 3.0 Connectivity/Encrypted DICOM
Specifications: Console Dimensions Height- 70 mm (2.75 in) console only
- 100 mm (3.94 in) with handle
Width- 295 mm (11.61 in) console only
- 343 mm (13.50 in) with handle
Length- 346 mm (13.62 in) console only
- 375mm (14.76 in) with handle
Weight with Battery: Approximately 5.2 Kg (11.5 lbs)Operator Keyboard- Alphanumeric Keyboard
- Ergonomic Hard Keys
- Backlight Keys
Display Screen- 15 in High-Resolution Color LCD
- Resolution: 1024 x 768
- Horizontal/Vertical viewing angle: +/-80 degree
- Brightness Adjustment
- Integrated Speakers
- Audio Volume Adjustment
- Interactive Dynamic Software Menu
Console Electrical Power- Voltage: 100-240 V AC
- Frequency: 50/60 Hz
- Power: Max. 130 VA
Applications:GE Logiq E R7 Portable Ultrasound Machine- Abdomen
- Cardiac
- Gynecology
- Musculoskeletal
- Obstetrical
- Nerve Block
- Pediatric
- Small Parts
- Urological
- Vascular
- Rheumatology
- Emergency Medicine
- Cardiac intra-operative
|
Reviews
There are no reviews yet.