| Description | Erchonia Zerona Z6 SHRZerona-Z6 works by utilizing the Erchonia’s patented low level laser technology to emulsify adipose tissue which then releases into the interstitial space. Our bodies remove the fat from the area and transport the fat from through the lymphatic system creating a slimming effect. The Zerona-Z6 was proven through a double-blind, randomized, multi-site, and placebo controlled study in which clients averaged a loss of 3.52* inches compared to the placebo group that lost only a half an inch. | Focus Medical Naturalight IPL – Acne, Vein, Skin Rejuvenation, Hair Removal. Includes: Handpiece, (1) VR Filter – Vein & Vascular Lesion Removal, (1) AR Filter – Acne Treatment, (1) SR Filter – Skin Rejuvenation, (1) HR Filter – Hair Removal, Filter Case, Cart and 180 Day Warranty. | IDS Daeshin Shiny Photo Skin Rejuvenation & Hair Removal. Includes: (2) Handpieces with 3 Different Wavelengths Each; Handpiece #1: 415-950nm, 560-950nm & 640-950nm; Handpiece #2: 640-1200nm, 695-1200nm, & 755-1200nm; Also Includes: (2) Handpiece Holders, Power Cable, Water Refill Kit, (2) Keys, Operator Manual, (2) Operator Eyewear, Patient Eyewear and 180 Day Warranty. | Anti-cellulite therapy (stage I III)
Elimination of lymphatic congestion
Muscle and connective tissue tightening
Circumference reduction/slimmingIncludes:
1 D-Actor (Radial) Handpiece
1 V-Actor (High Frequency Vibration) Handpiece
1 New Replacement Part Kit for D-Actor Handpiece – Includes Bullet and Barrel
1 Operator Manual | The image can then be displayed on a monitor, helping you to educate your patients The HRK can provide peripheral keratometry measurement data which is very useful when fitting contact lenses. The eye can be displayed in full colour mode on a tilting touch screen which enables you to see the patient’s contact lens fitting status, previously only possible using a slit lamp. As the HRK has the world’s first contact lens fitting function in an auto keratometer, you can now see the flourescein liquid with blue illumination along with automatic calculation and recommendation for contact lens fitting. | Includes:
1 Fiber Holder
5 Fibers
2 Cannula
1 Lipo Card
Footswitch
1 Operator Manual |
| Content | Erchonia Zerona Z6 SHR
The Erchonia Zerona Z6 SHR Laser is specially designed for use during non-invasive body contouring (ZERONA). The Zerona Z6 Laser is applied externally and has proven through four double-blind clinical trials to emulsify adipose tissue.Zerona-Z6 is a new body-sculpting procedure designed to target fat and contour the body without invasive surgery. Zerona-Z6 unlike other procedures, allows the client to continue their daily activities without interruptions from surgery, pain, wounds or garments.Zerona-Z6 works by utilizing the Erchonia’s patented low level laser technology to emulsify adipose tissue which then releases into the interstitial space. Our bodies remove the fat from the area and transport the fat from through the lymphatic system creating a slimming effect. The Zerona-Z6 was proven through a double-blind, randomized, multi-site, and placebo controlled study in which clients averaged a loss of 3.52* inches compared to the placebo group that lost only a half an inch.SPECIFICATIONSConfiguration: 6 Line Generated Class 2 Laser Diode Modules
Wavelength: 635nm
Modulation: Constant Wave (CW)
Display: Full-Color TFT Touch Screen Control Center
Adjustments:
1) 44” (111.76 cm) Vertical Arm Height Adjustment.
2) Four Independent Adjustable Arms for Desired Laser Concentration
Power Source: 100-240VAC 50-60Hz
Chassis:
1) Metal Frame Powder Coated for Ease of Cleaning
2) 4 Anti-Static Casters (2 Locking)
Housing: Black Carbon Fiber Finish Thermoformed from Non-Allergen Material
Weight: 70lbs. (31.76 kg)
Accessories: 2-Keys, Laser Safety Glasses
Compliant to Quality / ISO 13485 – Medical Device / IEC60825-1 Laser Safety, IEC 60601-1
Safety, IEC 60601-1-2 EMC, CB Mark, CB Cert
FDA Laser Class 2 / FDA Device Class ll EU Device Class IIa, Laser Class IIZERONA-Z6 ADVANTAGE
– No pain, no downtime and no risk
– Proven effective
– Superior treatment area coverage2018 Erchonia Zerona Z6 SHR, Includes: (2) Keys, Operator Eyewear, Operator Manual, Background and Protocol Guide, Marketing Materials, Female/Male Measurement Forms.Zerona-Z6 works by utilizing the Erchonia’s patented low level laser technology to emulsify adipose tissue which then releases into the interstitial space. Our bodies remove the fat from the area and transport the fat from through the lymphatic system creating a slimming effect. The Zerona-Z6 was proven through a double-blind, randomized, multi-site, and placebo controlled study in which clients averaged a loss of 3.52* inches compared to the placebo group that lost only a half an inch. | Focus Medical Naturalight IPL
Focus Medical Naturalight IPL Specifications :Wavelength: 450-1200nm, IPL Pulsed Light
Energy Density: Up to 35 J/cm2
Pulse Width: Up to 200ms
Display: LCD Screen
Spot Size: 40 x 10mm2
Dimension: 35 x 45 x 26cm
Weight: 40 lbs
Power Supply: 110V 60hzManufacturer Notes
The innovative NaturaLight IPL system utilizes the latest pulsed light technology to deliver light energy at its best. The NaturaLight has all the advantages of easy operation, wide ranging applications, and a high performance to price ratio. The body of the NaturaLight is compact with variable light guides and a unique user interface to make it one of the most versatile and easy to use aesthetic systems available. The NaturaLight Pulsed Light System offers unmatched versatility, performance, and innovation.Pulsed Light or Intense Pulsed Light (IPL) is the one technology no aesthetic practice should be without. New technology and advanced techniques have continuously improved IPL efficacy, increased treatment safety, expanded the number of treatments, and generally increased the usability of this technology. Procedures such as hair removal, vascular/facial veins, and acne are effective and fast with highly successful outcomes. NaturaLight incorporates the latest in technology and new procedure techniques to provide a simple-to-use advanced pulsed light system. The NaturaLight has raised the bar with advances in both skin tightening and control of the light output.Available Wavelength FiltersHR – Hair Removal
AR – Acne Removal – Acne Treatment
SR – Skin Rejuvenation & Pigment & Pigmented Lesion Removal
ST – Skin Tightening
VR – Vein & Vascular Lesion RemovalKey BenefitsAutomatic Parameter Selection which Increases Safety and Patient Efficacy
Variable Pulsing
More Effective Use of Pulsed Light Energy
Multiple Applications
Low Cost of Ownership2017 Focus Medical Naturalight IPL – Acne, Vein, Skin Rejuvenation, Hair Removal. Includes: Handpiece, (1) VR Filter – Vein & Vascular Lesion Removal, (1) AR Filter – Acne Treatment, (1) SR Filter – Skin Rejuvenation, (1) HR Filter – Hair Removal, Filter Case, Cart and 180 Day Warranty. | IDS Daeshin Shiny
IDS Daeshin Shiny is upgraded from the existing RPL model using our independent technology for innovative The better Photo rejuvenation & Hair removal treatment and more compact designSHINY represents the latest version of skin care equipment, which is built with the innovation technology of IDS Ltd. For safe and easy operation, the company has refined its technology and conducted clinical tests for many years.User instructionSHINY is suitable for treatment procedures for pigmented lesions, vascular lesions, acne and hair removal using basic wavelengths of 415nm, 560nm and 640nm. It can be also used for treatment of dark skin rejuvenation and hair removal by shifting to optional wavelengths of 640nm, 695nm and 755nm (ALEX Light). Wavelength can be selected very easily using a small rotator on the handpiece.Fast treatmentThe interval between each shot is shorter than that of the previous versions, and this makes the treatment easier and faster.Verified parametersBy smart protocols proper wavelength can be selected easily. The set parameters are optimized based on many clinical experiments to deliver maximal effects and safety.Advantages & Stronger points comparing to other devicesWhite toning (415nm)
Low depth of penetration (0.05~0.1mm) / High absorption (Melanin & Hemoglobin)
Safety (Fractional Concept IPL) / Excellent efficacy for faintly pigmented lesionsFractional type is our patent
Less side effects by heat (Fractional safety zone)Combine Rejuvenation (415nm 560nm) –> Amazing result in skin toning (Best in the world)Acne treatment
Fast hair removal (SHR)
ALEX (755nm) for hair removal (Best in the world)Technical FeaturesMaximal safety is achieved by Lattice technology based on fractional concepts. Lattice Optimal benefits of Lattice are provided by cutting edge technology.Traditional Spot SHINYRotating technology-based on IPL
SHINY allows easy choice of a wavelength range desired by using a rotator mounted in the hand piece. Selection of Wavelengths is easy without replacing the filter or the hand piece. (Patent No. 10-2004-0012778)Stable energy supplyA steady energy supply, which is achieved by technological expertise, allows safe operation of this beauty equipment and maximizes effects of treatment effects for each skin type.Cooling system can be controlledSemiconductor-based cooling system of SHINY can be controlled via the monitor, and maintains a steady temperature once it is set. This cooling system is aimed for minimizing pain of the patient and side effects.Light Source:Split (Intense) Pulsed Light (Xenon lamp)
Wavelength:415~950nm, 560~950nm, 640nm~950nm
Option: 640~1,200nm, 695~1,200nm
Fluence:5~40J/cmtwo
Spot Size:14.3 X 42.6mm
Pulse Sequence:Single , Double , Tripple Pulses, SHR mode
Pulse Duration:2.0 ~ 35.0ms
Pulse Delay:3.0 ~ 60.0ms
Repetition Rate:1Hz, 3Hz, 5Hz(Per Second)
Light Conduction:Quartz/ Sapphire Coupling
Cooling:Approximately up to 5℃, adjustable
Electrical Requirements:220V/16A, 50/60Hz
Physical Dimensions:360(D) X 520(L) X 1230(H)mm
Weight:60Kg2017 IDS Daeshin Shiny Photo Skin Rejuvenation & Hair Removal. Includes: (2) Handpieces with 3 Different Wavelengths Each; Handpiece #1: 415-950nm, 560-950nm & 640-950nm; Handpiece #2: 640-1200nm, 695-1200nm, & 755-1200nm; Also Includes: (2) Handpiece Holders, Power Cable, Water Refill Kit, (2) Keys, Operator Manual, (2) Operator Eyewear, Patient Eyewear and 180 Day Warranty. | STORZ MEDICAL CELLUPULSE D-ACTOR 200
Storz Medical Cellupulse D-Actor 200 Acoustic Wave Therapy – Performed with the radial D-ACTOR 200 applicator uses high-energy acoustic waves that are introduced into the patients body in the form of high-frequency oscillations. »AWT« is the first effective and long-lasting treatment modality for cellulite stage I to III.Acoustic waves have been used in medicine with great success since 1980 for the disintegration of kidney stones (ESWL) and since 1992 for the treatment of orthopedic conditions such as tendon and muscle disorders (ESWT).Before AWT:
Enlarged fat cells bulge upwards towards the skin surface, giving the skin the typical orange peel appearance. The inelastic vertical connective tissue fibres do not stretch along with the surrounding adipose tissue, which leads to the undesirable dimpling. Local blood circulation is significantly reduced.During AWT:
Oscillating acoustic waves are introduced into the body. The connective tissue relaxes, and the firmness of the epidermis increases. Blood circulation in the tissue is significantly enhanced. Collagen production is stimulated, strengthening the dermis and epidermis.After AWT:
The results of AWT are improved firmness and restored natural elasticity of the skin and connective tissue along with a visible and long-lasting improvement in skin texture.Laser Type: AWT – Acoustic Wave Therapy
Operating Mode D-ACTOR: D-ACTOR – Single Pulse, Continuous Pulse 1 – 21 Hz
Energy Selection D-ACTOR: Steps of 0.2 bar ranging from 1.4 to 5.0 bar
Mains Input Voltage: 100 – 240 VAC
Mains Frequency: 50/60 Hz
Mains Fuse: 5 AT/250 VAC
Mains Power Link Cable: 100 – 240 VAC/5A
Power Consumption with Auxiliary Device: Max 500 VA
Compressed Air Supply: 6 – 7 Bar
Compressed Air Output: 1.4 – 5 Bar
Control Unit Weight: 14.33 lbs, 6.5 kg
Housing Dimensions: (W x H x D) 13.4 in x 6.5 in x 13.4 in, 340 x 165 x 340 mm
Successful Anti-Cellulite Therapy per AWT – Acoustic Wave Therapy
Range of applicationStorz Medical Cellupulse D-Actor 200 Medical and cosmetic practitioners use the radial AWT applicator primarily for the following applications:Anti-cellulite therapy (stage I III)
Elimination of lymphatic congestion
Muscle and connective tissue tightening
Circumference reduction/slimmingAWT treatment areas:Upper arm
Stomach
Gluteal region
Thighs | Huvitz HRK-8000A Auto Refractor KeratometerHuvitz Auto Ref – Keratometer HRK-8000A- Touch and tilting 7″ LCD Screen that allows for free and smooth tilting for viewing at any angle.
- Optimized Optical System
- Micro Lens Array
- Aberration Measurement which also can be displayed in a graphical Zernike Refraction Map
- PSF & Image Simulation
- Colour View Mode
- Peripheral Keratometry Measurement
- Ultra High Precision KER Data
- Contact Lens Fitting Assistance Guide
- Contact Lens Prescription Guide
- Auto Tracking
- Animated Guide
- Faster Measurement Speed
- Quiet and speedy auto cutting printer
- More data on aberration measurement
With its extreme precision and accuracy, the HRK8000A uses the most advanced wavefront technology to measure the light reflected from the retina and helps you to diagnose any refractive error. With a micro lens array developed by Huvitz, the HRK creates a number of focal points, the pattern of which can give a valuable insight into the patients ocular system. The HRK not only displays the conventional data such as spherical, cylinder and axis, the high order aberration data is displayed in a graphical Zernike refractive map, giving you a deeper understanding of your patient’s eyes.Optimized Optical System Huvitz HRK-8000A Auto Refractor Keratometer
A wavefront is a physical representation of the optical quality of a light beam. Using various methods, aberrometers map how light rays travel through the eye. The HR-8000A is engineered according to the Hartmann-Shack wavefront measurement technique, which is widely preferred for its speed and repeatability.Touch & Tilting Color Display Screen
A bright, high contrast 7″ VGA color TFT LCD screen provides high resolution video images. A smooth, free tilting function also offers you a comfortable and clear view at any angle.The image can then be displayed on a monitor, helping you to educate your patients The HRK can provide peripheral keratometry measurement data which is very useful when fitting contact lenses. The eye can be displayed in full colour mode on a tilting touch screen which enables you to see the patient’s contact lens fitting status, previously only possible using a slit lamp. As the HRK has the world’s first contact lens fitting function in an auto keratometer, you can now see the flourescein liquid with blue illumination along with automatic calculation and recommendation for contact lens fitting. | OSYRIS LIPOTHERME PHARAON 980 LASER – DIODEOSYRIS Lipotherme Pharaon 980 Laser – DiodeLaser Type:Diode
Wavelength:970 nm
Optical Power:25 Watts
Fiber Connector:SMA 905
Cooling:Pelier Module and Air
Laser Safety Class:4
Supply Voltage:110 – 240 VAC
Frequency Sector:50 – 60 HzLaser Lipolysis with Lipotherme offers:- Minimally invasive vs. traditional liposuction
- Faster procedure to have performed, usually as an “in office” procedure
- Minimal Healing – less destruction to blood vessels and tissues near the fat cells means less blood loss and reduced post procedure downtime.
- Minimal Discomfort and typically performed under Local AnesethiaThe clinical term for this type of procedure is laser-assisted lipolysis (also called laser lipolysis or laser lipo for short) which is an evolution of traditional liposuction. Although effective, traditional liposuction is considered a highly invasive procedure. By contrast, Lipotherme laser lipolysis is a minimally-invasive procedure with virtually no downtime. Most patients resume normal activities the day after their procedure, however, it is recommended you wait several days before resuming strenuous activity such as exercising. Depending on your goals and physical condition, Lipotherme can be an alternative to traditional liposuction, or your doctor may recommend a combination therapy of Lipotherme with traditional liposuction.
Osyris Medical Lipotherme Applications:- Laser-assisted lipolysis
- Skin tightening
- Collagen regeneration
- Circumferential reduction
- Body contouring
Osyris Medical Lipotherme Features:- Laser: red diode 980 nm
- Output: one to 25 watts
- Pulse duration: θ (continuous)
- Fiber: 600 µm
- Variable power control
- Cooling system: Peltier and air
- Electric power: 110-240 VAC, 50 to 60 Hz
- Weight: 33 pounds
- Dimensions: 17 by 17 by 14 inches
Lipotherme Benefits:
* Lipotherme is a safe, effective, minimally invasive procedure that uses a laser to liquefy and remove unwanted fat in targeted body zones. In addition to removing unwanted fat, Lipotherme’s thermal effect causes the skin to contract, resulting in firmer, smoother skin that further enhances your body shaping goals.* The Lipotherme continuous wave diode laser operates with a unique 980 nm source filter that emits from one to 25 watts of power in a continuous wave, unlike the Nd:YAG lasers, which emit pulsed waves.* The power is variable so that physicians can customize the treatment for each patient and body area. For example, 6 W may be appropriate for the chin, arms, and knees, while 15 W may be appropriate for the thighs, hips, and buttocks.OSYRIS Lipotherme Pharaon 980 Laser – DiodeExotherme is a transcutaneous vascular laser, dedicated to spider veins and telangiectasias, up to 2mm of diameter, for a safe, efficient and painless treatment.Principle
The principle of the Exotherme laser is based on the thermal action of the laser. The transcutaneous irradiation (with a penetration of 1 to 2 mm in the tissue) causes tissue selective absorption by hemeglobin (hemoglobin is the main target of the laser).The effect of selective photocoagulation is based on two effects:Conversion of light energy into heat,
Coagulation of the vascular wall with collagen denaturation.
Selective photocoagulation does not cause purpura (contrary to photothermolysis).The superficial vessels, from 0.2 to 2 mm of diameter.Spider veins
Telangectasias
Exotherme is cleared on the US market for the photocoaguation of leg telangiecatasias. |