| Description | Configuration:5 3b Line Generated Laser Diode Modules
Wavelength:635nm
Modulation:Constant Wave (CW) 1,000 Hz
Programming:5 time saving presets
Display:8″ Full color TFT Touch Screen Control Center
Power Source:100-240VAC 50-60Hz
Chassis:Power Coated metal frame for ease of cleaning
Housing:Thermoformed of Non-allergen material/plastic
Accessories:2 Keys, Laser Safety Glasses
Dimensions:49 x 32 x 57H”
Weight:266 lbs. | - This Multi-function system offers a wide range of treatments.
- 1046nm long pulsed Nd:Yag treating hair removal, fungal nail and deep thread veins.
- 650nm & 585nm IPL handpieces including for both hair removal, skin rejuvenation, thread veins, pigmentation and more.
- This system can be added to with a 2940 fractional handpiece
- Safety goggles supplied
- Delivery, installation and warranty included.
| Laser Hair Removal
Details:- Serial Number: SQEAY-19M-XXXXX (message for serial number)
- System Total Shot Count: 560,693
- Alex Shot Count: 221,437
- YAG Shot Count: 339,256
Includes:- Handpiece and Delivery System
- Square Spot Sizes: 2x2mm, 3x3mm, 5x5mm, 10x10mm, 14x14mm, 18x18mm, 20x20mm, 24x24, 27x27mm
- Fiber Pole
- Foot Switch
- System Key
- Operators Manual
- 30 Day Parts and Labor Warranty
| Advanced ergonomic handpiece with multi-spot, quick-zoom cartridges, and large touch screen GUI. | Alma Inc announces the North American release of Opus, a new modern aesthetic platform featuring the company’s proprietary high-frequency unipolar radio-frequency technology, Opus Plasma.Reportedly the first-of-its-kind fractional plasma technology, Opus Plasma is engineered to address global or localized textural and skin quality concerns often corrected with conventional fractional resurfacing lasers in the past. | 2017 Lumenis Lightsheer Desire with 3 Handpieces – HS, XC and ET – Includes 805 and 1060 nm wavelengths – Like-New Condition; Serial Number: 3796, Date of Manufacture 2/15/2017, Excellent Cosmetic and Operating Condition – Like New with low pulses! RECENTLY INSPECTED April 2021, Included Handpieces & Pulse Counts: HS 22×35 mm Spot Size Diode Handpiece = 132 Pulses; XC 12×12 mm Spot Size Diode Handpiece = 3,362 Pulses; ET 9×9 mm Spot Size 1060 Handpiece = 6,590 Pulses; Also Includes: Operator Manual, 2 Pair Operator Eyewear, 1 Pair Patient Eye Shields, (1) Key, and 120 Day Warranty |
| Content | ERCHONIA ZERONA Z5 LASER
The Erchonia Zerona Cosmetic Laser model is designed for use during non-invasive body contouring. It is a body sculpting machine designed to remove fat and contour the body without the invasive surgery that many patients prefer not to go under.Zerona is the only clinically-proven non-invasive body contouring treatment, providing 6 quick & painless treatments. These treatments specifically target stubborn fat areas and painlessly emulsify the fat under your skin using the Lymphatic system.ZERONA is the first non-invasive body slimming procedure to effectively remove excess fat!
Unlike other lipo and body slimming procedures, ZERONA allows patients to continue daily activities without interruptions from surgery, pain, wounds, bruises, or garments. The ZERONA protocol utilizes the Erchonia Laser Scanner, which is the safest and most researched low level laser in the world. ZERONA is also FDA approved for laser assisted liposuction. Find out how it worksVoluminous adipose tissue can appear when fatty material is present, and this, in turn, can bring about enlarged subcutaneous fat regions. Because subcutaneous fat is close to the skin’s surface, laser emulsification can have a dramatic effect on them. The collapse of adipose arrangements has been noted after laser therapy, reducing their volume and providing effective body slimming results. When the fat cells have reduced the body naturally excretes the fat over time giving the patient proven results after around six treatments over two weeks. This occurs during the bodys normal detoxification process.Configuration:5 3b Line Generated Laser Diode Modules
Wavelength:635nm
Modulation:Constant Wave (CW) 1,000 Hz
Programming:5 time saving presets
Display:8″ Full color TFT Touch Screen Control Center
Power Source:100-240VAC 50-60Hz
Chassis:Power Coated metal frame for ease of cleaning
Housing:Thermoformed of Non-allergen material/plastic
Accessories:2 Keys, Laser Safety Glasses
Dimensions:49 x 32 x 57H”
Weight:266 lbs.ERCHONIA ZERONA Z5Let’s take a closer lookERCHONIA ZERONA Z5 LASERFour separate histological studies were performed to assess the efficacy of laser in the emulsification (liquefaction) of fat. Scanning electron microscopy (SEM) and transmission electron microscopy (TEM) were utilized to analyze adipose tissue. SEM and TEM images revealed the collapse of adipose arrangements subsequent to laser therapy. The voluminous state of an adipocyte cell is reduced due to the emulsification process. The fatty material is evacuated from the cell and moves into extracellular space. The voluminous nature of adipocytes due to the accumulation of fatty material is what gives rise to an enlarged subcutaneous fat region. ZERONA induces the formation of a transitory pore in the membrane of the fat cell. The pore enables the fatty material to seep out across the aperture and into extracellular space. The following images show the result of laser energy on a single fat cell and a group of fat cells.As you can see the ZERONA treatment liquifies the fat and the cell dumps it into the intercellular space. There are two types of fat cells – Subcutaneous and Visceral.Subcutaneous fat is located directly above the skeletal muscle and below the skin. Its superficial placement is what ensures proper depth penetration of the laser energy. Patients containing a high volume of visceral fat (fat below the skeletal muscle) are not ideal candidates for this procedure. However, they may still contain subcutaneous fat; therefore, you can treat the individual by just ensuring they adopt a healthy diet to address the visceral fat. | Lynton Lumina IPL HR Laser
2013 Lynton Lumina IPL HR Laser Hair Removal 650nm 585nm 1064 YAG Beauty MachineIn very good condition and full working order
Purchase new in December 2013, so less than a year old
Laser has minimal use total count of 29427 from newPlease click HERE for further information
Included:-
1 x 2013 Lynton Lumina IPL YAG Laser Hair Removal Beauty Machine
1 x Lynton 650 IPL Handpiece in protective storage box – Total Handpiece Shots 21600
1 x Lynton 585 Plus IPL Vascular Handpiece in protective storage box – Total Handpiece Shots 385
1 x Lynton 1064 YAG Laser Vascular Handpiece with 3mm, 6mm, 8mm tips in protective storage box – Total Handpiece Shots 7442
1 x Set of 3 IPL light guides in protective storage boxFor the following treatments
650nm Hair removal
650nm C.F.TMachine can do the following
585nm Vascular Plus
585nm Pigmentation Plus
585nm Photorejuvenation Plus
585nm Acne Plus
The ultimate ‘build as you grow’ laser & IPL machine, offering practitioners the opportunity to dramatically increase and extend their treatment portfolio, without having to purchase numerous devices. British manufactured and listed on the NHS Supply Chain, the LUMINA offers the UK’s most in-demand treatments; hair removal, tattoo removal, anti-ageing and skin resurfacing.Highly versatile, and with numerous revenue capabilities, the Lumina delivers fast and clinically effective treatment results with superior efficacy. As the best-selling multi-function aesthetic machine, the LUMINA has a proven track record of building, growing and establishing clinics as the No.1 in their area.As our flagship machine, and the product of over 20 years expertise in the design, development and manufacture of laser/IPL systems, the LUMINA is specifically designed to be adaptable to address emerging applications. As well as unrivalled laser technology, the LUMINA has a built-in patient database and parameter printer, and benefits from its easy-to-use touchscreen. 1. Intense Pulsed Light (IPL): the perfect combination of hair removal and skin rejuvenation treatments come as standard with the LUMINA system via its 585 & 650 handpieces.Hand-piece
Type Wavelength(s) Maximum
Fluence Treatments Spot Sizes Maximum
rep. rate
585 Intense
Pulsed Light 550 – 1100nm 50J/cm2 Superficial Vascular
Superficial Pigmentation
Active Acne
Skin-rejuvenation 1x1cm
2.5x1cm
5x1cm
1cm circular 1Hz
650 Intense
Pulsed Light 625 – 1100nm 40J/cm2 Hair removal (1 to 5)
Collagen treatment 1x1cm
2.5x1cm
5x1cm
1cm circular 1Hz
650 Advance IPL hand-piece, which has been designed to provide faster results in hair removal of finer, lighter hairs found on the face and navel. The 650 Advance hand-piece has software optimised for the greater power it delivers, allowing experienced practitioners to treat finer and fairer hairs successfully, in skin type 1 to 3 clients in a single or dual pulse mode. | 2019 Lumenis Splendor X- Laser Hair Removal
Lumenis Splendor X Laser Hair RemovalThe Alexandrite wavelength at 755 nm, which is ideal for treating skin tones 1, 2 and 3 (fair and light skin tones). It is highly absorbed in melanin and is therefore not safe for use on darker skin tones.
The Nd:YAG wavelength at 1064 nm, which is ideal for treating skin tones 4, 5 and 6 (4 being tanned skin and 5 and 6 darker skin tones) as the absorption by melanin is much lower than with the Alexandrite wavelengthThe Lumenis Splendor X has been introduced to be a player in the solid state Nd:YAG and Alexandrite laser hair removal market. The gold standard for hair removal has always been considered Alexandrite 755nm for light skins and Nd:YAG 1064nm for dark skins.The Lumenis Splendor X combines both in a unique way with blended emission.Instead of firing a single wavelength at a time the Splendor X allows you to fire both wavelengths simultaneous in adjustable amounts to suit the skin type and hair types. This means you are target multiple chromophores at any given time given enhanced results across the board.The Lumenis Splendor X also allows the user to choose between square and round spot sizes with large spot sizesLumenis Splendor X Laser Hair RemovalThe Alexandrite wavelength at 755 nm, which is ideal for treating skin tones 1, 2 and 3 (fair and light skin tones). It is highly absorbed in melanin and is therefore not safe for use on darker skin tones.
The Nd:YAG wavelength at 1064 nm, which is ideal for treating skin tones 4, 5 and 6 (4 being tanned skin and 5 and 6 darker skin tones) as the absorption by melanin is much lower than with the Alexandrite wavelengthLaser Hair Removal
Details:2019 Lumenis Splendor X- Laser Hair Removal- Serial Number: SQEAY-19M-XXXXX (message for serial number)
- System Total Shot Count: 560,693
- Alex Shot Count: 221,437
- YAG Shot Count: 339,256
Includes:- Handpiece and Delivery System
- Square Spot Sizes: 2x2mm, 3x3mm, 5x5mm, 10x10mm, 14x14mm, 18x18mm, 20x20mm, 24x24, 27x27mm
- Fiber Pole
- Foot Switch
- System Key
- Operators Manual
- 30 Day Parts and Labor Warranty
| Lutronic Clarity II
Lutronic’s Clarity II is a high-powered, dual-wavelength platform that effectively delivers a wider range of parameters to help safely and efficiently treat the broadest indications with ease. The innovative design includes: a single fiber for all spot sizes(2-25mm), intuitive interface, and no need for calibration after any parameter change. Clarity II can save time and help facilitate faster, more effective treatments.
Higher power 755/1064nm platform for effective treatments up to 45%* faster.
Brilliantly removes hair, pigment, and vascular lesions in all skin types.
IntelliTrak technology and Temperature Sensing enable increased provider confidence and treatment efficacy.Clarity II
Key Feature
1. Powerful and faster
Provide up to 25mm spot size at a useable >2 Hz
High power performance
Up to 45% faster
2. Intelligent and convenientIntelliTraking system to prevent skip area and consistent treatment
Real time skin temperature monitoring system
3. Designed for versatilityIntelligent memory function to keep track of past treatment history in detail
Zoom cartridge system for treatment areaLutronic Clarity IIHow It Works
The CLARITY II Laser System contains two separate laser resonators, Alexandrite and an Nd:YAG, which generate pulse laser energy at the nominal wavelength of 755nm and 1064nm respectively. The output of each laser generator and the 515nm aiming beam are optically combined on the laser rail so that their beam paths are identical as they exit the laser system. This allows the use of a single delivery system for either the 755nm or 1064nm wavelength.Clarity II
with IntelliTrak technologyHigher-powered 755/1064nm platform laser
Up to 2X faster Laser Hair Removal Txs*
Exclusive shorter pulsewidths available including 1ms setting
for finer facial hairs
Breakthrough intelligent capabilities
IntelliTrak technology for faster more consistent Tx coverage
Temperature Sensing for real-time skin temp feedback
during Tx
Auto-calibration in seconds saves time and
improves productivity
Advanced, easy-to-use platform
Single fiber for all 2-24mm spot cartridges
Numerous skin rejuvenation capabilities including vascular,
pigment, and toning Txs
*At settings of: 755nm, 5ms, 12J/cm2: Clarity II at 22mm, 3Hz, IntelliTrak at 18% overlap vs.
older system at 18mm, 2Hz, and est. ~18% manual overlap. Geometric treatment coverage speed is
11.4cm/second with Clarity II vs. 5.1cm/second with older system. | Alma Opus Plasma Laser RF FractionalAlma Opus Plasma Laser RF Fractional Skin Resurfacing is the first-of-its-kind fractional plasma technology. It represents a new chapter for energy-based devices, addressing global or localized textural and skin quality concerns often corrected with conventional fractional resurfacing lasers in the past.Operating at a high frequency of over 40MHz, the metal pins on the Opus Plasma tips are super-charged with high-voltage. When in close proximity of the skin, the charged pins react to atmospheric pressure in the air, creating plasma that in turn, creates the microthermal zones of fractional injuries.Treatment delivers radio frequency energy at multiple levels to customize a treatment for your specific skincare concerns, using a range of settings to safely and effectively resurface the skin
Able to treat face, neck, decollete, hands, stomachs, etc.INDICATED USES
Fine Lines and wrinkles
Skin laxity
Uneven tone
Unwanted pigmentation
Stretch marks
Acne scarsWHAT IS OPUS PLASMA/HOW DOES IT WORKOpus Plasma represents a new chapter for energy-based devices, addressing global or localized textural and skin quality concerns often corrected with conventional fractional resurfacing lasers in the pastOperating at a high frequency of over 40MHz, the metal pins on the Opus Plasma tips are super-charged with high-voltage
When in close proximity of the skin, the charged pins react to atmospheric pressure in the air, creating plasma that in turn, creates the microthermal zones of fractional injuries
Our Opus treatment delivers radio frequency energy at multiple levels to customize a treatment for your specific skincare concerns, using a range of settings to safely and effectively resurface the skin
Able to treat face, neck, decollete, hands, stomachs, etc.DOES IT HURT/WHAT IS THE DOWNTIMEWe will apply a numbing cream before the treatment to make you as comfortable as possible, but you may still feel mild heat and pressure during the treatment
We also offer and highly recommend a prescription numbing cream
After a consultation, our Nurse will write you a prescription that we call in to Wellspring. This numbing cream is around $40 and allows us to turn up the machine resulting in a much better treatment
Most people tolerate the treatment well
You may experience some redness, but you can go back to your usual routine immediately after the treatment
You will appear to have a sunburn look
Your specialists will talk to you about aftercare at your consultation | Lumenis Lightsheer Desire (Include Handpiece)
comes fully loaded with 3 handpieces – ET (9X9), XC (12X12) & HS (22X35)the LightSheer DESIRE uses an 805nm diode wavelength. This wavelength is the industry’s Gold-Standard and has been clinically proven to safely and effectively treat all skin types Available Treatments: - Hair removal, permanent hair reduction, and the treatment for Pseudofolliculitis Barbae(PFB).
- Treatment of vascular lesions, including angiomas, hemangiomas, telangiectasia, leg veins and other benign vascular lesions.
- Treatment of benign pigmented lesions.
Unique features: - The “Gold standard” 805nm diode laser.
- 3 handpieces with various spot sizes.
- 2 advanced technologies.
The ET has a Sapphire ChillTip spot size of 9x9mm designed to treat small areas that require maximum precision and high fluence.The XC has a Sapphire ChillTip spot size of 12x12mm, providing optimal solution for large and small areas requiring higher fluence levels.The HS has a HIT 22x35mm spot size enabling use of low-fluence and a unique mechanism of pain reduction, providing safe, fast and comfortable treatment. | Product Specifications |
|---|
| ET | | | Laser Type | AIGaAs Diode Arrays | | Wavelength | 805 nm (nominal) | | Spot Size | 9 mm X 9 mm | | Repetition Rate | Up to 3 Hz | | Pulse repetition | 1 Pulse | | Fluence | 10-100 J/cm2 | | Pulse Width | 5-400 ms | | Peak Power | 1600 W | | Comfort Management | Chilltip contact cooling (5O C) | | Preset Parameters | Yse |
| XC | | | Laser Type | AIGaAs Diode Arrays | | Wavelength | 805 nm (nominal) | | Spot Size | 12 mm X 12 mm | | Repetition Rate | Up to 3 Hz | | Pulse repetition | 1 Pulse | | Fluence | 10-40 J/cm2 | | Pulse Width | 5-400 ms | | Peak Power | 2400 W | | Comfort Management | Chilltip contact cooling (5O C) | | Preset Parameters | Yse |
| HS | | | Laser Type | AIGaAs Diode Arrays | | Wavelength | 805 nm (nominal) | | Spot Size | 22 mm X 35 mm | | Repetition Rate | Up to 3 Hz | | Pulse repetition | 1 – 3 pulses | | Fluence | 4.5-12 J/cm2 | | Pulse Width | 30-400 ms | | Peak Power | 2300 W | | Comfort Management | Vacuum assisted (up to18inHg) | | Preset Parameters | Yse |
Lumenis Lightsheer Desire (Include Handpiece) – Like New |
Reviews
There are no reviews yet.