| Content | ELLMAN PELLEVE S5 REDUCTION SYSTEM
The Pelleve S5 System is a new generator based on the proven Surgitron technology. In addition to powering the Pelleve handpieces, it provides maximum control in precision cutting with minimal thermal damage to surrounding tissues, plus more versatility than other energy-based technologies, including:Wrinkle reduction treatment with the new GlideSafe(TM) handpieces
Hundreds of surgical electrodes and accessories for most specialties
Portable and light weight – ideal for office and clinic environmentsWxHxD: 9.5 x 7.1 x 16.5
Weight: 26 lbs.
Ambeint Temperature: +10 degrees C – +40 degrees C
Relative Humidity: 30% – 75%
Normal Line Voltage: 100V, 120V / 220V, 240V – + 10%
Line Frequency: 60Hz./50Hz.
Input current at max output power: 3.4A/1.5A
Pelleve Wrinkle Reduction System
Ellagance Through Science
Pelleve S5 SystemPelleve precisely delivers energy to the dermal tissue using advanced radiofrequency technology to induce collagen contraction without damaging the epidermis. The result is skin tightening and contouring with a noticeable improvement in skin quality and texture.Pelleve’s unique radiofrequency technology emits energy in the form of electromagnetic waves, which create a heated treatment zone. Increased resistance causes heat buildup at the subdermal junction. Heat induces collagen denaturation and collagen contraction. Protein stimulation causes new collagen formation and production in the dermis which also results in epidermal tightening. Existing bands of collagen tighten in subcutaneous fat, creating a superficial tightening of the epidermis.Unparalleled Safety ELLMAN PELLEVE S5 REDUCTION SYSTEM
The Pelleve System delivers continuous radiofrequency energy which enables the clinician to choose how much energy to deliver and in what areas. By using a combination of the different sizes of Pelleve handpieces that are available each patient’s specific areas of concern can be addressed, resulting in patients receiving just the right amount of energy. The new GlideSafe handpieces feature an innovative sensor designed to stop energy flow when the device senses loss of contact with skin, further enhancing the safety.Non invasive, non ablative office treatment
Patients today are seeking affordable, non invasive alternatives to ablative and surgical procedures. The Pelleve System fills that void.Minimal side effects
A Pelleve treatment is virtually pain free and no anesthetic is used for the treatment. The patient may experience some transient erythema or edema, which is typically gone in a few hours.PelleFirm is a non-invasive cellulite treatment that uses radiofrequency energy and massage to deeply heat tissues and temporarily reduce the appearance of cellulite.ELLMAN PELLEVE S5 (TM) HandpiecesPelleve GlideSafe handpieces feature an innovative sensor designed to stop energy flow when the device senses loss of contact with skin – resulting in a more comfortable treatment for the patient. The GlideSafe Handpieces are available in 4 sizes – 7.5 mm, 10 mm, 15 mm, 20 mm – to allow the physician clinician to customize to the individual patient. The compact ergonomic design enables practitioners to comfortably maneuver around the contours of the face, including areas that are difficult to access such as the periorbital region. Each handpiece delivers multiple hours of treatment (activation) time so doctors have the option of customizing each patient’s treatment by using different size handpieces for different areas of the face. This advanced feature allows users to treat multiple patients and perform many procedures using the same charged handpiece.Surgical Versatility
An innovative multi-modality system, the Pelleve Wrinkle Reduction System offers physicians unmatched versatility in a compact design. Beyond skin tightening, the ELLMAN PELLEVE S5 platform facilitates scores of procedures with the availability of hundreds of monopolar and bipolar electrodes.Skin tightening plus surgical procedures
You can use the Pelleve system to deliver aesthetic treatments plus surgical treatments with the S5 platformAdds value to your practice
An ideal procedure to delegate to physician extenders and bundle with other servicesPractice profitability
Low operating costs yield enhanced profitability relative to treatment feeWide range of surgical electrodesFor use with the Pelleve Generator and all other Ellman generators are hundreds of standard and specialty surgical electrodes facilitate procedures ranging from minimally invasive treatments through full surgical procedures. Unlike conventional ESU generators, the Ellman generators are high-frequency radiofrequency devices that enable precise cutting and control with minimal thermal damage. Minimizing tissue damage improves aesthetic outcomes and reduces recovery time. | Lumenis Lightsheer Desire (Include Handpiece)
comes fully loaded with 3 handpieces – ET (9X9), XC (12X12) & HS (22X35)the LightSheer DESIRE uses an 805nm diode wavelength. This wavelength is the industry’s Gold-Standard and has been clinically proven to safely and effectively treat all skin types Available Treatments: - Hair removal, permanent hair reduction, and the treatment for Pseudofolliculitis Barbae(PFB).
- Treatment of vascular lesions, including angiomas, hemangiomas, telangiectasia, leg veins and other benign vascular lesions.
- Treatment of benign pigmented lesions.
Unique features: - The “Gold standard” 805nm diode laser.
- 3 handpieces with various spot sizes.
- 2 advanced technologies.
The ET has a Sapphire ChillTip spot size of 9x9mm designed to treat small areas that require maximum precision and high fluence.The XC has a Sapphire ChillTip spot size of 12x12mm, providing optimal solution for large and small areas requiring higher fluence levels.The HS has a HIT 22x35mm spot size enabling use of low-fluence and a unique mechanism of pain reduction, providing safe, fast and comfortable treatment. | Product Specifications |
|---|
| ET | | | Laser Type | AIGaAs Diode Arrays | | Wavelength | 805 nm (nominal) | | Spot Size | 9 mm X 9 mm | | Repetition Rate | Up to 3 Hz | | Pulse repetition | 1 Pulse | | Fluence | 10-100 J/cm2 | | Pulse Width | 5-400 ms | | Peak Power | 1600 W | | Comfort Management | Chilltip contact cooling (5O C) | | Preset Parameters | Yse |
| XC | | | Laser Type | AIGaAs Diode Arrays | | Wavelength | 805 nm (nominal) | | Spot Size | 12 mm X 12 mm | | Repetition Rate | Up to 3 Hz | | Pulse repetition | 1 Pulse | | Fluence | 10-40 J/cm2 | | Pulse Width | 5-400 ms | | Peak Power | 2400 W | | Comfort Management | Chilltip contact cooling (5O C) | | Preset Parameters | Yse |
| HS | | | Laser Type | AIGaAs Diode Arrays | | Wavelength | 805 nm (nominal) | | Spot Size | 22 mm X 35 mm | | Repetition Rate | Up to 3 Hz | | Pulse repetition | 1 – 3 pulses | | Fluence | 4.5-12 J/cm2 | | Pulse Width | 30-400 ms | | Peak Power | 2300 W | | Comfort Management | Vacuum assisted (up to18inHg) | | Preset Parameters | Yse |
Lumenis Lightsheer Desire (Include Handpiece) – Like New | Zimmer zwave pro laser system body contouring
The high energy radial shockwaves scientifically proved to have a large impact on collagen structure and the skin connective tissue, improving blood circulation.
It stimulates collagen formation, while the skin becomes more elastic and its firmness is visible after only a few treatments.
Thanks to the ZWave radial shockwave unit, it is also possible to significantly improve skin firmness, skin elasticity and collagen regeneration. Fat reduction, for example, after CryolipolysisTM or injection lipolysis is also enhanced by using the ZWave.ZWave & ZLipo – the perfect combination
Skin tightening and body contouring are becoming increasingly important in the modern practice. After several treatments for fat reduction, such as e.g. CryolipolysisTM, liposuction, or injection lipolysis, a more extensive application for skin tightening is urgently recommended and expected by the patient. Various studies and user observations have proven its effectiveness.Skin tightening and body contouring
ZWave is used as a “stand-alone” application or in combination with other, mostly fat reduction methods. In the case of the “stand-alone” application, the focus is generally on improving the skin structure and connective tissue. Typical application areas are, e.g. cellulite, connective tissue weakness (upper arm, underbelly, etc.) and stretch marks (striae).Zimmer ZWave Pro Laser System Body ContouringTechnology:Electro-magnetically generated Radial Pulse Technology, 1-22 Hz, 60-185mJ
Programs:3 recommended application presets
Controller:12 color touch screen for all software operations. Full range control for energy and frequency.
Foot switch:control for hand piece.
Memory and Update:SD card for custom programs by user/error log/firmware updates
Voltage:110 volts, 60 Hz
Dimensions & Weight:L 20.5 / W 21 / H 54.5 Weight: 70 lbs.
Z Wave Pro Catch the Z Wave
The Zimmer ZWave Pro Body Contouring transmits powerful sound waves into the tissue. The energy then spreads out radially to enhance the treatment effect.
The body responds to the Z Wave Pro sound waves with increased metabolic activity in the form of lymphatic drainage and increased blood circulation.
The end result is an improvement in the appearance of cellulite and other body contouring procedures.
Z Wave & Cryolipolysis Enhanced Results
Thanks to Z Wave, it is possible to significantly enhance body contouring results with CryolipolysisTM and RF treatments.
Various studies have shown its effectiveness with body contouring treatments.Application Range
Cellulite Treatment and Enhanced Body Shaping
Z Wave is used as a stand-alone application or in combination with body contouring treatments. As a stand-alone application, the focus is on improving the appearance of cellulite.Patient-friendly Application
Zimmer ZWave Pro Body Contouring Radial Pulse Technology has the following advantages:gentle, painless and quick treatments
no disposables
no down time
non-invasive treatment
visible results
versatile
easy to operate
superior alternative to hand massage post body sculpting
consistently reproducible resultsHand Piece Characteristics
efficient energy transfer from hand piece to deep tissue structures up to 35 mm
treatment is comfortable for both patient and technician
hand piece is controlled via foot switch
each Z Wave Pro comes with 2 hand pieces and is ready for use any time
each hand piece is warranted for 2,000,000 pulses. The two hand pieces should yield approximately 1,600 application zones
enhanced patient comfort due to longer rise time (pulse width) without the need for unpleasant high peak energy | LUMENIS POLLOGEN LEGEND PRO
Skin treatments platform with unique RF assist ultra-thin electrodes and TriPollar RFThe Legend Pro system intended for dermatological procedures requiring ablation and resurfacing of the skin when using VoluDerm Energy (Applicator VO). It is also intended for use in dermatologic and general surgical procedures for the non-invasive treatment of mild to moderate facial wrinkles and rhytides when using TriPollar RF Energy (Applicators 1-3) Intended settings for the device: Clinics & Hospitals.Radio-frequency (RF) MicroneedlingAdvancements in radio-frequency give providers the ability to treat new patient segments. Legend Pro is our skin treatments platform with clinically proven technologies that target the specific needs of each patient, while NuEra Tight provides personalized RF deep heating for smoother skin, head to toe.Includes:
3 Radio Frequency Handpieces
1 Radio Frequency MicroNeedling Handpiece
Footswitch
Operators ManualLegend ProSkin treatments platform with unique RF assist ultra-thin electrodes and TriPollar RFImagine a treatment with immediate results, long term efficacy, minimal pain and downtime, and no need for numbing… Sounds too good to be true?
Legend Pro is all that, and more.Patients benefitsOffer your patients Legend Pro’s synergetic technologies, providing endless options for personalized treatment plans, targeted at answering the specific needs and desires of each patient.By encouraging and enhancing the natural healing processes in the skin, Legend Pro unveils the best in each patient. From resurfacing of the upper layers of the skin to promoting the regeneration of collagen and elastin fibers in the deeper dermis, Legend Pro offers a complete toolkit for creating tailor-made treatments and personalized results for your patients.Input Voltage:100-2400 Volt,50-60Hz, max 2.2A
Mode of Operation:VoluDerm, TriFractional, Tripollar
Maximum Output Power RF:50 Watts @ 200 Ohm
Maximum Output Voltage:100 Plus or Minus 10 Vrms
Output Frequency RF:1Mhz
Output Power Control RF:Pulse Width Modulation (PWM)
Weight: 66 Kgs
Dimensions:L1.5 x W1.5 x H3.6 Inch
Environmental Conditions for Operation
Temperature:15 Degrees Celsius to +30 Degrees Celsius (59-86 Degrees Farrenheit)
Relative Humidity:Up to 80%; Non- Condensing
Atmospheric Pressure: 70-106 kPa
Maximum Altitude:2000 Meters
Environmental Conditions for Transportation & Storage
Temperature:-20 Degrees Celsius to + 55 Degrees Celsius (-4-131 Degrees Farrenheit)
Relative Humidity:80%; Non-Condensing
Atmospheric Pressure:50-106 kPa
Maximum Altitude:2000 MetersLumenis Pollogen Legend ProClinically proven RF thermal skin regeneration technologyLegend Pro’s clinically proven technologies work in synergy to achieve the results you and your patients seek.TriPollar RF ApplicatorsTriggering regeneration of collagen and elastin fibers, by delivering focused RF energy in a safe and effective manner, inducing controlled heating of the deep dermisVoluDermActivating the body’s natural healing processes by applying RF-assisted ultra-thin electrodes to thermally ablate the epidermis, creating micro channels to induce controlled micro wounds, thus encouraging the generation of new and healthy skin.TriFractionalApplying contact RF and pin point ablation with controlled volumetric heating to achieve skin resurfacing and regeneration via wound healing process, resulting in skin texture improvement and refinement.Legend M² unique synergized treatment combines the macro volumetric heating of tissue with TriPollar RF and the precise micro heating of focal points with VoluDerm RF assisted ultra-thin electrodes. Treatments with Legend M²™ reaches multiple layers of the skin introducing a wide range of solutions for skin resurfacing and inducing regeneration as well as wrinkle reduction.Thanks to the unique technologies behind Legend Pro, patients experience minimal pain and downtime during and after treatment, without the need of numbing cream before the treatment. The desired results are promptly visible. Indications include: skin resurfacing and treatment of mild to moderate wrinkles and rhytids.POLLOGEN LEGEND IS AN ADVANCED MEDICAL AESTHETIC PLATFORM INCORPORATING THE LEADING INDUSTRY TECHNOLOGIES – HYBRID ENERGY TECHNOLOGY, TRILIPO USING NON-INVASIVE TRIPOLLAR RF ENERGY, AND DYNAMIC MUSCLE ACTIVATION. THE COMBINATION OF THESE TECHNOLOGIES PROVIDES EFFECTIVE DERMAL VOLUMIZING, SKIN TIGHTENING, AND BODY SCULPTING.Treatment with the Pollogen LEGEND device is effective and fast with minimal discomfort. It is suitable for all skin types and ethnicities and carried out in a simple ‘walk-in walk-out’ treatment with minimal downtime.-Visible results after the 1st treatment-Long-term measurable results-Minimal discomfort, minimal downtime-Easy to use with a fast learning curve | EMVERA CLARO2 CO2 LASER
Claro2 Medical Laser System
The Claro2 laser technology offers the most innovative approach to laser treatments today. It provides an acceptable and comfortable procedure under little or no anesthesia with minimum pain from evaporation of the skin layers, resulting in minimal social or work downtime. The laser delivers a series of microscopic, closely-spaced laser spots to the skin while simultaneously preserving the normal, healthy skin. The undamaged skin becomes a reservoir of tissue for fast heating and regeneration of the treated area by producing and providing new dermal collagen and eliminating epidermal pigmentation and irregularities to the skin tone. The Claro2 laser system is specially designed to improve skin texture and tone, and fight wrinkles, scars and pigmentations. Since the treatment procedures are customized to patients skin, operators are able to adjust laser settings to tailor treatments and achieve superior results.Claro2 Laser Features Provide:
Unparalleled char-free ablation, vaporization, excision, or incision of soft tissues
Reduced thermal damage to surrounding tissues
Rapid healing and minimal downtime
Stimulation of deeper collagen with high pulse energy
Large TFT LCD touch screen provides easy operation with the latest high speed microprocessor technology
Adjustable scanning patterns and sizes
Adjustable intensity of pilot beam
Adjustable pulse duration
Last treatment setting memorization
Automatic alarm system for operation and errors
No consumable costsIncludes:
1 Fractional Scanner Handpiece for Ablative Skin Resurfacing
1 Incisional Handpiece with up to or less than .2mm Spot Size
Handpiece Case
Distance Gauges
Footswitch
Patient Eyewear
Operator Eyewear
Operator Manual
Warning SignLaser Type:Sealed of Co2 Laser
Wavelength:10.6 um
Mode Structure:TEM00
Max Power:0-30W (adjustable)
Spot Size:Equal to or less than .2mm
Aiming Beam:630nm Red Laser (Adjustable Brightness)
Delivery System:Articulated Arm
Operation Modes:Continuous Wave, Single Pulse, Repetition Pulse, Super Pulse, Scanner
Pulse Width:Single Pulse (0.01-1s); Repetition Pulse (0.001-1s); Scanner (0.0001-0.01s)
Scan Size: Adjustable
Scan Pattern:Oval, Triangle, Rectangle, Line
Scan Array Density:Adjustable
Cooling System:Self-Contained, Closed Cycle
Power Supply:100-120V AC, 50/60Hz or 200-240V AC, 50/60Hz
Environment Temperature:10-40 Degrees Celsius
Relative Humidity:Below 80%
Dimensions:561mm x 500mm x 1443mm
Weight:42kgApplications Include:EMVERA CLARO2 CO2 LASERDermatology, Plastic Surgery and General Surgery procedures including but not limited to:
Laser skin resurfacing
Treatment of furrows and wrinkles
Removal of skin tags, actinic keratosis, acne scars, keloids, tattoos, telangiectasia, squamous and basel cell carcinoma, warts and uneven pigmentation
Treatment of cysts, abscesses, hemorrhoids and other soft tissue applications
Blepharoplasty
Site preparation for hair transplantsOtorhinolaryngology (ENT) procedures including but not limited to:
Treatment of leukoplakia of larynx, nasal obstruction, rhinophyma, verrucrea vulgares, choanal atresia, rhinophyma, LAUP and papillomatosis polypsGynecology:
Treatment of condyloma acuminate, cervical
intraepithelial neoplasia, leukoplakia and vulvar/
vaginal intraepithelial neoplasia, cervical dysplasia
Podiatry procedures including but not limited to:
Ablation, vaporization and excision of soft
tissue lesions such as ingrown nail, fungal nail,
porokcratoma, matrixectomy and verrucae vulgares | ACTIVE OPTICAL EXTRA 818 IPL HAIR REMOVAL MACHINEIncludes:
Footswitch
Operators Manual
AntiFreeze Coolant
Patient & Operator EyewearHandpieces:Hair Removal Handpiece and Facial Handpiece
Chilled Tip:Up to 4c
Pulse Interval:0.5~2 Seconds
Output Power:11-31 joule/cm2, upto 4,000W
Cooling System:Revolutionary dual cooling
Control:Intuitive touch screen control
Lamp’s Life Span:250,000 Flashes (Universal), 200,000 Flashes (Facial)
Treatment Area:7.5 cm2 (15*50mm) Universal, 4.5 cm2 (15*30mm) Facial
Wavelength:420-1100 nm
Weight:42Kg (including Stand, if device is not a table top)
Dimensions:44cm x 45cm x 100cm
Extra-818
Skin Rejuvenation
Pigmentation Treatment
Acne Treatment
Hair Removal
Vascular (Facial) TreatmentThe combination of tested treatment protocols with high end engineering makes the Extra – 818 the perfect device for leading clinics.Revolutionary Cooling System
The Extra – 818 has a dual cooling system, controlled and monitored in order to ensure long lifetime to the lamp and a comfortable treatment to the patient.Competitive cooling systems “freeze” the skin so that during the treatment the skin temperature will rise to a bearable level. However, this “freezing” temperature might limit the results because the follicles will not reach the coagulation temperature. To ensure optimal results Active installed a special Processor that prevents overcooling the skin and maintains a uniform low temperature of the “glass” throughout the treatment. This revolutionary system enables the Extra – 818 to provide best results with optimal patient comfort.Research Program ACTIVE OPTICAL EXTRA 818 IPL HAIR REMOVAL MACHINE
For clinical investigations, the self setting program allows researchers to set the treatment’s parameters according to their needs. Allowing advanced research with the device.
The energy levels in the self setting program can reach 31Jcm2 with high intensity of 4,000W.The Active Optical Extra 818 IPL Hair Removal and Skin Rejuvenation is the outcome of more than a decade of treatments and thousands of devices operated worldwide. It contains It contains unique features:
* Contemporary touch screen control
* Built-in Patch Test procedure for examining the optimal energy level
* A stunning number of 450,000 flashes in both lamps.The Extra – 818, based on Active’s GEM-PL technology, sets sets a specific Pulse Pattern according to the selected treatment type, skin color, skin photosensitivity and treatment depth.
The treatment protocols and different pulse patterns take into account the tissue’s TRT (Thermal Relaxation Time) and the combined knowledge accumulated from thousands of treatments done during the years and clinical investigations done to confirm the findings. |
Reviews