| Description | 2014 Eclipse Aesthetics Equinox Co2; Manufactured 01/21/2014; Excellent Cosmetic and Operating Condition, Single Owner, Received Full Maintenance and Certification That It is Operating Perfectly at the Hightest Energy Levels from Licensed Technician on 09/17/2017, Record Available Upon Request; Includes: (2) Keys, Footswitch, Interlock, Operator Manual, Warning Sign, and 90 Day Warranty.km | IDS Daeshin Shiny Photo Skin Rejuvenation & Hair Removal. Includes: (2) Handpieces with 3 Different Wavelengths Each; Handpiece #1: 415-950nm, 560-950nm & 640-950nm; Handpiece #2: 640-1200nm, 695-1200nm, & 755-1200nm; Also Includes: (2) Handpiece Holders, Power Cable, Water Refill Kit, (2) Keys, Operator Manual, (2) Operator Eyewear, Patient Eyewear and 180 Day Warranty. | 2019 Edge Hydrafacial MD Elite Elo; Like New Cosmetic and Operating Condition, Single Owner, Only Used for 20 Treatments; Reason for Selling: No Longer Offering This Treatment; Includes: Tower, Cartridge Handpiece, (2) Red LED Light Wireless Handpieces, (2) Blue LED Light Wireless Handpieces, (1) Lymphatic Drainage Treatment System, Skin Imaging Camera, (4) Bottles of Solution, (20) Bottles of Serums, (20) Tips, Cleaning Kit, Operators Manual. | Candela GentleMAX ProEstablished in 1970, Candela is a leading US-based global medical aesthetic device company with headquarters in Wayland, Massachusetts. The company’s technologies enable physicians to provide advanced energy-based solutions for a broad range of medical-aesthetic applications including benign vascular and pigmented lesions, scars, hair removal, facial resurfacing, wrinkle reduction, women’s health treatments, tattoo removal, acne, leg veins, cellulite, and body shaping. | New Handpiece Design The Optima – 518 Classic is the first model to use the new Mark II which enables a multipurpose handpiece:
* Faster treatments – up to 0.5 Seconds Between pulses.
* Real-time handpiece temperature control.
* Contemporary and stylish design.
* Light weight design – 25% less weight to improve the therapists’ comfort. | The ability to work specifically in the deep dermis, without damaging the epidermis, is regulated in the RF Secret by the delay time of fractional radiofrequency. The needles are inserted at a rate of milliseconds equal to a stamping process in the skin and also withdrawn immediately. Only after the needles are penetrated into the desired skin layer, is carried out for a few milliseconds, a radio frequency pulse to set heat damage. While the penetration into the skin, the needles remain always cold. In order to achieve a deep and superficial effect, the needle depths can be varied individually in the respective treatment passes. |
| Content | Eclipse Aesthetics Equinox Co2Laser Type:Fractionated Co2
Wavelength:10,600nm
Power Output (continuous):1-30 W, 75 W
Power Supply:100-240V, 50/60Hz, 800 W
Pulse Energy:1-300mJ
Spot Density:2-40, 100%
Scan Area Size:From 1x1mm to 15x15mm
Scan Area Shapes:Square, Triangle, Circle (multiple sizes)
Operation Mode:Stamp, Moving (Auto ON)
Length of Pulse:0.05 – 10ms
Display:Color LCD touch screen
Weight:35kg
Beam Divergence:<7mrad A Fractional CO2 Laser
Provides highest quality treatments for fine lines and wrinkles, scar revisions, acne scars, hyperpigmentation.CO2 Laser Skin Resurfacing Eclipse Aesthetics Equinox Co2
CO2 laser skin resurfacing precisely removes the outer layers of damaged and aged skin to reveal the underlying layer of beautiful, smooth, and younger looking skin. CO2 laser technology is the most common used skin resurfacing surgery today. The latest CO2 laser resurfacing technology uses beams that are scattered or pulsed at a very rapid rate.
This method minimizes the exposure of heat that your skin undergoes which removes heat damage your skin would be exposed to as well as decreases after surgery recovery time. It also allows a higher power CO2 laser to be used to reach deeper tissue and more pronounced creases and wrinkles. Benifits of CO2 laser skin resurfacing include deeper scar and damaged tissue removal. By removing the damaged outer layer of skin, CO2 laser skin resurfacing treatment can slow down and reverse the process of aging. Further CO2 laser treatments include uneven pigmentation, precancerous spots, photodamage, and many other skin imperfections and benign lesions.The EQUINOX fractional CO2 laser can be used to effectively treat fine lines and wrinkles, acne and surgical scars, skin pigmentation and discoloration, sun damage, pre-cancerous as well as benign lesions and uneven skin texture. EQUINOX, in the hands of an experienced Plastic Surgeon, delivers dramatic, visible improvement in a single 30 minute treatment session. EQUINOX can resurface compromised or damaged skin in order to provide rejuvenation with excellent improvement of fine lines and wrinkles, acne, surgical scars, skin pigmentation or discoloration, sun damage, pre-cancerous and benign lesions. | IDS Daeshin Shiny
IDS Daeshin Shiny is upgraded from the existing RPL model using our independent technology for innovative The better Photo rejuvenation & Hair removal treatment and more compact designSHINY represents the latest version of skin care equipment, which is built with the innovation technology of IDS Ltd. For safe and easy operation, the company has refined its technology and conducted clinical tests for many years.User instructionSHINY is suitable for treatment procedures for pigmented lesions, vascular lesions, acne and hair removal using basic wavelengths of 415nm, 560nm and 640nm. It can be also used for treatment of dark skin rejuvenation and hair removal by shifting to optional wavelengths of 640nm, 695nm and 755nm (ALEX Light). Wavelength can be selected very easily using a small rotator on the handpiece.Fast treatmentThe interval between each shot is shorter than that of the previous versions, and this makes the treatment easier and faster.Verified parametersBy smart protocols proper wavelength can be selected easily. The set parameters are optimized based on many clinical experiments to deliver maximal effects and safety.Advantages & Stronger points comparing to other devicesWhite toning (415nm)
Low depth of penetration (0.05~0.1mm) / High absorption (Melanin & Hemoglobin)
Safety (Fractional Concept IPL) / Excellent efficacy for faintly pigmented lesionsFractional type is our patent
Less side effects by heat (Fractional safety zone)Combine Rejuvenation (415nm 560nm) –> Amazing result in skin toning (Best in the world)Acne treatment
Fast hair removal (SHR)
ALEX (755nm) for hair removal (Best in the world)Technical FeaturesMaximal safety is achieved by Lattice technology based on fractional concepts. Lattice Optimal benefits of Lattice are provided by cutting edge technology.Traditional Spot SHINYRotating technology-based on IPL
SHINY allows easy choice of a wavelength range desired by using a rotator mounted in the hand piece. Selection of Wavelengths is easy without replacing the filter or the hand piece. (Patent No. 10-2004-0012778)Stable energy supplyA steady energy supply, which is achieved by technological expertise, allows safe operation of this beauty equipment and maximizes effects of treatment effects for each skin type.Cooling system can be controlledSemiconductor-based cooling system of SHINY can be controlled via the monitor, and maintains a steady temperature once it is set. This cooling system is aimed for minimizing pain of the patient and side effects.Light Source:Split (Intense) Pulsed Light (Xenon lamp)
Wavelength:415~950nm, 560~950nm, 640nm~950nm
Option: 640~1,200nm, 695~1,200nm
Fluence:5~40J/cmtwo
Spot Size:14.3 X 42.6mm
Pulse Sequence:Single , Double , Tripple Pulses, SHR mode
Pulse Duration:2.0 ~ 35.0ms
Pulse Delay:3.0 ~ 60.0ms
Repetition Rate:1Hz, 3Hz, 5Hz(Per Second)
Light Conduction:Quartz/ Sapphire Coupling
Cooling:Approximately up to 5℃, adjustable
Electrical Requirements:220V/16A, 50/60Hz
Physical Dimensions:360(D) X 520(L) X 1230(H)mm
Weight:60Kg2017 IDS Daeshin Shiny Photo Skin Rejuvenation & Hair Removal. Includes: (2) Handpieces with 3 Different Wavelengths Each; Handpiece #1: 415-950nm, 560-950nm & 640-950nm; Handpiece #2: 640-1200nm, 695-1200nm, & 755-1200nm; Also Includes: (2) Handpiece Holders, Power Cable, Water Refill Kit, (2) Keys, Operator Manual, (2) Operator Eyewear, Patient Eyewear and 180 Day Warranty. | Edge Hydrafacial MD Elite EloHydrafacial:HydroPeel tip resurfaces skin while simultaneously introducing topically applied serums For melasma, brown spots, wrinkles & fine lines, oily & acne- prone skin. Skin-specific serums for deep cleansing, exfoliating, extracting, hydrating, antioxidant treatment and more
Diamond Abrasion:Dry diamond crystal- free abrasion can be combined with wet HydraFacial treatment for deeper abrasion. Various crystal-free tips ranging from fine to extra coarse
LED Light Therapy:Red and infrared light, Blue light
Massage Therapy:Facial lymphatic drainage and Cellulite massage HydraFacial Elite is a non-invasive, multi-step treatment that combines the benefits of next-level hydradermabrasion, a chemical peel and painless extractions with a special delivery of antioxidants, hyaluronic acid and peptides. It delivers real results in less than 30 minutes without any downtime or irritation.The Elite uses Intuitive ISP technology that can be adapted to include new treatments and products as new trends emerge. The built-in skin imaging camera gives clients proof the treatments are working, and the photo comparison feature tracks clients progress visit after visit. Cordless LEDs are always ready for use when charged in their designated USB ports. The Elite also includes a pre-treatment video that educates clients on their treatments to make them feel more comfortable and better understand expectations.Edge Hydrafacial MD Elite Elo tip resurfaces skin while simultaneously introducing topically applied serums For melasma, brown spots, wrinkles & fine lines, oily & acne- prone skin. Skin-specific serums for deep cleansing, exfoliating, extracting, hydrating, antioxidant treatment and more
Diamond Abrasion : Dry diamond crystal – free abrasion can be combined with wet HydraFacial treatment for deeper abrasion. Various crystal-free tips ranging from fine to extra coarse
LED Light Therapy:Red and infrared light, Blue light
Massage Therapy:Facial lymphatic drainage and Cellulite massage | 2017 Candela GentleMAX Pro Device DetailsThe Candela GentleMax Pro yields high energy, subjecting patients to fewer laser pulses providing faster treatment times with the 24mm spot size, the largest spot found on any hair removal laser. Candela’spatented Dynamic Cooling Devise (DCD) technology protects the upper layers of skin with cooling bursts of cryogen. DCD cooling offers optimal treatment with minimal side effects.| Distributor | Candela |
|---|
| Manufacturer | Candela |
|---|
| Model | GentleMAX Pro |
|---|
| Manufactured Year | 2017 |
|---|
| Specific Equipment Type | Dual Wavelength Laser |
|---|
| Sale Price | 12500 |
|---|
| Treatments Performed | Hair Removal, Vascular, Pigmentation
Skin Rejuvenation
Skin Tightening |
|---|
| Handpieces | Standard Handpiece DCD 12-18mm , Large Spot Size Handpiece DCD 22-24mm |
|---|
| Shot Counts | None |
|---|
| Wavelengths | 755nm
1064nm |
|---|
| Consumables used by device | Windows, Distance Gauges |
|---|
| Consumables with purchase | 3 x Operator goggles, 1 x patient goggles, distance gauges, windows |
|---|
| Annual Service Price | Servicing available through Candela |
|---|
| Service Contract Price | $11,000 per annum |
|---|
| Additional Information | Any additional information can be sent on request |
|---|
| |
|---|
Treatments:2017 Candela GentleMAX Pro Device Details- Hair Removal
- Beard Bumps
- Facial Lesions
- Fine Lines and Wrinkles
- Leg Veins
- Skin Tightening
- Vascular Lesions
- Warts
- Skin Rejuvenation
- Hemangiomas
- Birthmarks
- Freckles
- Melasma
- Mevus of Ota
- Pigmented Lesions
- Sun / Age Spots
The Candela GentleMax Pro yields high energy, subjecting patients to fewer laser pulses providing faster treatment times with the 24 mm spot size, the largest spot found on any hair removal laser.Fast – With 24 mm spot size and repetition rates up to 2 Hz, the The Candela GentleMax Pro yields high energy, subjecting patients to fewer laser pulses providing faster treatment times with the 24 mm spot size, the largest spot found on any hair removal laser. It has two wavelengths, the 755 Alexandrite and the 1064 ND:yag, allowing you to offer many treatment options.Candela’s patented Dynamic Cooling Devise (DCD) technology protects the upper layers of skin with cooling bursts of cryogen. DCD cooling offers optimal treatment with minimal side effects. offers fast treatment times with it’s spot size.Powerful – 26,333 watts peak power, capable of delivering fluences up to 100 J/cm² for vascular applications, and hair removal energy in pulse duration as short as 3 ms for unparalleled treatment efficacies.Treats all skin types – Deep penetration with minimal scattering of laser energy makes the GentleMax Pro ideal for all skin types, particularly dark and tanned skin.Versatile – Non-ablative treatment, including fine lines and wrinkles, and for pseudofolliculitis barbae (PFB), or beard bumps, leg and facial veins.Patented Epidermal Cooling – Candela’s Dynamic Cooling Device represents an adjustable epidermal protection technology to maximize patient safety and comfort.Date of Manufacture – 2017Accessories Included with Purchase – Specialty 1.5, 3mm, 3x10mm Handpiece, 6, 8, 10, 12, 15, 18mm Handpiece, Full Set of Distance Gauges, Distance Gauge Case, Patient Eyewear, Treatment Goggles, Foot Pedal, Fiber Pole, System Key, System Interlock Key, Treatment Guidelines, and User Manual. | Active Optical Systems Optima 518 IPL LaserHandpiece (Standard):Multipurpose Wavelength Mark-II
Handpiece (Optional):Facial Treatments
Pulse Interval/Repetition Rate:0.5 – 2 Seconds
Maximum Output Treatment Pattern:22 Joule /cm 2
Output Power:11-31 Joule / cm 2 , up to 4000 W
Cooling System:Improved Air Cooling
Control:Advanced Software Interface
Lamp’s Life Span:200,000 Flashes (minimum)
Treatment Area/Spot Size:15 x 50 mm, (7.5 cm 2)
Wavelength:420 – 1,100 nm
Weight:88.18 lbs (40Kg) (including stand)
Dimensions:17.32 inches x 17.72 inches x 39.37 inches (44cm x 45cm x 100cm)
Mains:220-230 VAC, 50/60 Hz; 100-120 VAC, 50/60 Hz
Max Mains Power:600 VA
Treatments Variety:
Skin Rejuvenation
Pigmentation Treatment
Acne Treatment
Hair Removal
Hair Removal – Deep Follicles
Hair Removal – Sensitive Skin
Vascular (Facial) Treatment
Tattoo Removal
The Laser uses 12 preset programs. The programs are set in a consecutive, energy intensity increasing order, as specified by the tables of settings, covering all types of hair and skin combinations to be treated.
12 Programs
1 – Very Dark Skin, Fitzpatrick Skin Type IV
2 – Dark Skin, Fitzpatrick Skin Type IV
3 – Dark Skin, Fitzpatrick Skin Type III
4 – Dark Skin, Fitzpatrick Skin Type III
5 – Medium Skin, Fitzpatrick Skin Type II
6 – Medium Skin, Fitzpatrick Skin Type II
7 – Light Skin, Fitzpatrick Skin Type II
8 – Light Skin, Fitzpatrick Skin Type I
9 – Very Light Skin, Fitzpatrick Skin Type I
10 – Very Light Skin, Fitzpatrick Skin Type I
11 – Very Light Skin, Fitzpatrick Skin Type I
12 – High Power, Fitzpatrick Skin Type IOptima-518-Classic Active Optical Systems Optima 518 IPL LaserThe Optima – 518 Classic was designed to answer the needs of sophisticated practitioners who want to provide state of the art treatment to their patients on one hand, based on proven and tested treatment protocols and on the other hand to have the ability to reach new and improved protocols by conducting innovative clinical investigations.The Optima – 518 Classic, based on active’s GEM-PL technology, sets the pulse pattern according to the selected treatment type, skin color, skin photosensitivity and treatment depth. The treatment protocols and different pulse patterns take into account the tissue’s TRT (Thermal Relaxation Time) and the combined knowledge accumulated from thousands of treatments done during the years and clinical investigations done to confirm the findings.New Handpiece Design The Optima – 518 Classic is the first model to use the new Mark II which enables a multipurpose handpiece:
* Faster treatments – up to 0.5 Seconds Between pulses.
* Real-time handpiece temperature control.
* Contemporary and stylish design.
* Light weight design – 25% less weight to improve the therapists’ comfort.Research program for clinical investigations, the self setting program allows researchers to set the treatment’s parameters according to their needs. Allowing advanced research with the device. The energy levels in the self setting program can reach 31J cm 2 with high intensity of 4000 W.Approvals
* CE MDD Intl. Medical Standard
* FDA U.S. Safety Standard
* ISO-13485 Med. Production STD
* IEC 60-601-1 Medical Safety STD
* CFS Gov. Health Approval
* CSA Can. & U.S. Safety App
* TGA Australian health STD. | CUTERA SECRET RF 2.0CUTERA SECRET RF 2.0 MICRONEEDLING RADIO is a fractional micro-needling system (fractional radiofrequency) that exceeds the capabilities and limitations of fractional laser significantly. It is a system for extensive skin structure improvement and treatment of hyperhidrosis (radio frequency thermotherapy RFTT), based on both monopolar and fractionated on, bipolar radio frequency. An exact adjustment of the depth of the microneedles and the cold passing the epidermis allow the energy output directly into the target layer.
The needle depth is 0.5 mm to 3.5 mm can be varied, thereby opening up a wide range of treatments. The adjustable intensity of the RF energy allows for the treatment of various areas of the body with different energy performance.The ability to work specifically in the deep dermis, without damaging the epidermis, is regulated in the RF Secret by the delay time of fractional radiofrequency. The needles are inserted at a rate of milliseconds equal to a stamping process in the skin and also withdrawn immediately. Only after the needles are penetrated into the desired skin layer, is carried out for a few milliseconds, a radio frequency pulse to set heat damage. While the penetration into the skin, the needles remain always cold. In order to achieve a deep and superficial effect, the needle depths can be varied individually in the respective treatment passes.Dermal Remodeling from the Inside Out
Demand for non-surgical aesthetic procedures with little to no downtime is on the rise. More than 70% of patients are bothered by signs of aging such as fine lines and wrinkles as well as skin texture and discoloration.1Secret RF is a novel fractional radio frequency (RF) micro-needling system for tissue coagulation and hemostasis designed to stimulate and remodel collagen and address the common signs of aging. It is ideally suited for use on patients who wish to revitalize and refresh the appearance of their skin on all skin types. By adjusting the micro-needles, Secret RF can deliver energy at various depths, so that treatments can be tailored to address each patients individual concerns such as fine lines, wrinkles, acne scars, photoaging and striae at the depth required.Secret RF System
Secret RFs unique technology and customized delivery of energy enables providers to tailor treatments for a variety of skin concerns on all skin types.Customized Dermal Remodeling
Secret RF induces dermal remodeling by applying precisely controlled RF energy directly into various depths of skin from 0.5-3.5 mm – with minimally invasive micro-needles to spare the epidermis and reduce patient downtime.Skin Revitalization and Resurfacing Secret RF is a radio frequency (RF) fractional microneedling system that helps you deliver tailored energy to improve fine lines, wrinkles, and scars from the inside out. Secret RF in action
Applications include fine lines and wrinkles, photoaging, scarring, acne scars, striaeSecret RF technology Handpieces
Two sizes of treatment tips – 25 and 64 pin – give you customizable options for treating the face and body with precision and efficiency.
Power:20 W ± 20%
RF frequency:2 Mh ± 20%
Intensity:0 ~ 100 Level (10 levels)
Repeat:0.2 / 0.5 / 1/2 sec / individually.
Needle Size:0.3 mm
Info about needles:25 electric needles (5 x 5, 7.8 mm x 7.8 mm / height: 1.95 mm (standard) and 16 electric needles (4 x 4, 7.8 mm x 7.8 mm / height 2.6 mm (optional)
Treatment range:1 x 1cm
Adjustable Depth:0.5 ~5 mm (0.1 steps)
Treatment duration:50 ms ~ 950 ms
Electrical power:100 ~ 240 VAC, 50/60 Hz, 220 VAMonopolar RF
Power:520 W ± 20%
RF frequency:2 Mh ± 20%
RF electrode:monopolar
Repeat:CW
RF electrode size:15APPLICATIONSFacialsNon-surgical facelift
Skin tightening
Pore reduction
Wrinkle reduction
Skin Rejuvenation (illumination)
Acne scars
Body treatmentsScar
Keratosis pilaris (Keratosis pilaris)
Stretch marks |