PERKASA MEDICAL

Free shipping worldwide. Orders over $200
Availability: In Stock

Eclipse Aesthetics Equinox Co2 2014 For Sale

$8,200.00

2014 Eclipse Aesthetics Equinox Co2; Manufactured 01/21/2014; Excellent Cosmetic and Operating Condition, Single Owner, Received Full Maintenance and Certification That It is Operating Perfectly at the Hightest Energy Levels from Licensed Technician on 09/17/2017, Record Available Upon Request; Includes: (2) Keys, Footswitch, Interlock, Operator Manual, Warning Sign, and 90 Day Warranty.km

Other people want this. 15 people have this in their carts right now.

Description

Eclipse Aesthetics Equinox Co2

Laser Type:Fractionated Co2
Wavelength:10,600nm
Power Output (continuous):1-30 W, 75 W
Power Supply:100-240V, 50/60Hz, 800 W
Pulse Energy:1-300mJ
Spot Density:2-40, 100%
Scan Area Size:From 1x1mm to 15x15mm
Scan Area Shapes:Square, Triangle, Circle (multiple sizes)
Operation Mode:Stamp, Moving (‘Auto ON’)
Length of Pulse:0.05 – 10ms
Display:Color LCD touch screen
Weight:35kg
Beam Divergence:<7mrad

A Fractional CO2 Laser
Provides highest quality treatments for fine lines and wrinkles, scar revisions, acne scars, hyperpigmentation.

CO2 Laser Skin Resurfacing Eclipse Aesthetics Equinox Co2
CO2 laser skin resurfacing precisely removes the outer layers of damaged and aged skin to reveal the underlying layer of beautiful, smooth, and younger looking skin. CO2 laser technology is the most common used skin resurfacing surgery today. The latest CO2 laser resurfacing technology uses beams that are scattered or pulsed at a very rapid rate.
This method minimizes the exposure of heat that your skin undergoes which removes heat damage your skin would be exposed to as well as decreases after surgery recovery time. It also allows a higher power CO2 laser to be used to reach deeper tissue and more pronounced creases and wrinkles. Benifits of CO2 laser skin resurfacing include deeper scar and damaged tissue removal. By removing the damaged outer layer of skin, CO2 laser skin resurfacing treatment can slow down and reverse the process of aging. Further CO2 laser treatments include uneven pigmentation, precancerous spots, photodamage, and many other skin imperfections and benign lesions.

The EQUINOX fractional CO2 laser can be used to effectively treat fine lines and wrinkles, acne and surgical scars, skin pigmentation and discoloration, sun damage, pre-cancerous as well as benign lesions and uneven skin texture.  EQUINOX, in the hands of an experienced Plastic Surgeon, delivers dramatic, visible improvement in a single 30 minute treatment session. EQUINOX can resurface compromised or damaged skin in order to provide rejuvenation with excellent improvement of fine lines and wrinkles, acne, surgical scars, skin pigmentation or discoloration, sun damage, pre-cancerous and benign lesions.

Reviews

There are no reviews yet.

Be the first to review “Eclipse Aesthetics Equinox Co2 2014 For Sale”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsEclipse Aesthetics Equinox Co2 2014 For Sale removeENDYMED PURE PLUS FOR SALE removeActive Optical Systems Optima 518 IPL Laser removeLutronic Clarity Long Pulsed Alexandrite & Nd:YAG Laser removeCutera Xeo with Full Nd Yag and Low Pulses For Sale removeACTIVE OPTICAL SYSTEMS OPTIMA 518 IPL LASER FOR SALE remove
NameEclipse Aesthetics Equinox Co2 2014 For Sale removeENDYMED PURE PLUS FOR SALE removeActive Optical Systems Optima 518 IPL Laser removeLutronic Clarity Long Pulsed Alexandrite & Nd:YAG Laser removeCutera Xeo with Full Nd Yag and Low Pulses For Sale removeACTIVE OPTICAL SYSTEMS OPTIMA 518 IPL LASER FOR SALE remove
Image
SKU
Rating
Price $8,200.00 $3,850.00 $5,200.00 $7,220.00 $7,600.00 $6,500.00
Stock
Availability
Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Description2014 Eclipse Aesthetics Equinox Co2; Manufactured 01/21/2014; Excellent Cosmetic and Operating Condition, Single Owner, Received Full Maintenance and Certification That It is Operating Perfectly at the Hightest Energy Levels from Licensed Technician on 09/17/2017, Record Available Upon Request; Includes: (2) Keys, Footswitch, Interlock, Operator Manual, Warning Sign, and 90 Day Warranty.kmThe PURE+ is offered in two configurations:FSR + TC: Fixed FSR handpiece + one exchangeable connector suitable for all TC handpieces: iFine, Small and Large TC Complete: Two exchangeable connectors on each side, suitable for all TC handpieces: iFine, Shaper, Small and LargeThe iFine treatment Handpiece – specially engineered to target fine lines and wrinkles found in the delicate thin – skin areas around the eyes, providing: Smoother, tighter skin around the eyes. Reduced under eye sagging and improved eye contour. Reduced hooding to reveal more of the eyelid. More youthful, less tired looking eyes. Softening of fine line enabling easier application of make-up.New Handpiece Design The Optima – 518 Classic is the first model to use the new Mark II which enables a multipurpose handpiece: * Faster treatments – up to 0.5 Seconds Between pulses. * Real-time handpiece temperature control. * Contemporary and stylish design. * Light weight design – 25% less weight to improve the therapists’ comfort.
The Dual Wavelength Solution that Delivers Suitable Parameters with an Incredible Fast Treatment SpeedLutronic CLARITY is a dual wavelength platform combining long pulsed 755 nm Alexandrite and 1064 nm Nd:YAG. CLARITY’s advanced features enable treatment versatility and greater speed.
Cutera Xeo LaserMultiple Technologies, Maximum FlexibilityIn today’s fast-paced aesthetic practices, maximum flexibility and upgradeability are paramount. Whatever your need, the Cutera Xeo Laser can provide the most versatile laser and light technologies on the market today. Whether you are interested in, Skin Fitness, hair removal, vascular therapies – or all the above – the Xeo can accommodate your specific needs through our upgradeable platform.The Cutera Xeo Laser combines the proven effectiveness of Cutera’s long-pulse Nd:YAG laser technology with the next generation of pulsed light treatments. The Cutera XEO can offer permanent hair reduction on all skin types, a complete range of vascular treatments and the next-generation in non-ablative combination skin therapy.ACTIVE OPTICAL SYSTEMS OPTIMA 518 IPL LASER includes: Handpiece, Footswitch, Operator Eyewear, Patient Eyewear, Cart, Key, Operator Manual, ultrasound gel, replacement fuses, replacement filters
Content

Eclipse Aesthetics Equinox Co2

Laser Type:Fractionated Co2 Wavelength:10,600nm Power Output (continuous):1-30 W, 75 W Power Supply:100-240V, 50/60Hz, 800 W Pulse Energy:1-300mJ Spot Density:2-40, 100% Scan Area Size:From 1x1mm to 15x15mm Scan Area Shapes:Square, Triangle, Circle (multiple sizes) Operation Mode:Stamp, Moving (‘Auto ON’) Length of Pulse:0.05 – 10ms Display:Color LCD touch screen Weight:35kg Beam Divergence:<7mrad
A Fractional CO2 Laser Provides highest quality treatments for fine lines and wrinkles, scar revisions, acne scars, hyperpigmentation.CO2 Laser Skin Resurfacing Eclipse Aesthetics Equinox Co2 CO2 laser skin resurfacing precisely removes the outer layers of damaged and aged skin to reveal the underlying layer of beautiful, smooth, and younger looking skin. CO2 laser technology is the most common used skin resurfacing surgery today. The latest CO2 laser resurfacing technology uses beams that are scattered or pulsed at a very rapid rate. This method minimizes the exposure of heat that your skin undergoes which removes heat damage your skin would be exposed to as well as decreases after surgery recovery time. It also allows a higher power CO2 laser to be used to reach deeper tissue and more pronounced creases and wrinkles. Benifits of CO2 laser skin resurfacing include deeper scar and damaged tissue removal. By removing the damaged outer layer of skin, CO2 laser skin resurfacing treatment can slow down and reverse the process of aging. Further CO2 laser treatments include uneven pigmentation, precancerous spots, photodamage, and many other skin imperfections and benign lesions.The EQUINOX fractional CO2 laser can be used to effectively treat fine lines and wrinkles, acne and surgical scars, skin pigmentation and discoloration, sun damage, pre-cancerous as well as benign lesions and uneven skin texture.  EQUINOX, in the hands of an experienced Plastic Surgeon, delivers dramatic, visible improvement in a single 30 minute treatment session. EQUINOX can resurface compromised or damaged skin in order to provide rejuvenation with excellent improvement of fine lines and wrinkles, acne, surgical scars, skin pigmentation or discoloration, sun damage, pre-cancerous and benign lesions.
ENDYMED PURE PLUS Input Power:100-120V, 50-60Hz, 2A or 220-240V, 50-60Hz, 1A Power Consumption:220 W Fuses:2 x 1.6A for 220V; 2 x 3.15A for 110V Output Power:Up to 50 Watts Output Frequency:1MHz Working Temperature:+10°C – +25°C Dimensions:(H x W x D) 600 x 305 x 365 mm Weight:10 kg GOOD THINGS COMES IN SMALL PACKAGES – THE PURE+ The Pure+ by Endymed Pure Plus, powered by our FDA cleared, patented 3DEEPRF technology. The PURE+ offers professional grade Fractional Skin Resurfacing and superior body, facial and neck tightening and contouring treatments, all on one easy to use, compact platform.The PURE+ offers complete flexibility with exchangeable treatment handpieces – one PURE+ console can be configured any way you like to provide you and your clients with the most effective and popular treatments available today.The PURE+ is offered in two configurations:FSR + TC: Fixed FSR handpiece + one exchangeable connector suitable for all TC handpieces: iFine, Small and Large TC Complete: Two exchangeable connectors on each side, suitable for all TC handpieces: iFine, Shaper, Small and LargeThe iFine treatment Handpiece – specially engineered to target fine lines and wrinkles found in the delicate thin – skin areas around the eyes, providing: Smoother, tighter skin around the eyes. Reduced under eye sagging and improved eye contour. Reduced hooding to reveal more of the eyelid. More youthful, less tired looking eyes. Softening of fine line enabling easier application of make-up.3Deep Small-Medium Handpiece Designed to treat wrinkles and lax skin on the face, neck and upper body.3Deep Fractional Skin Resurfacing Handpiece Specially designed for fractional skin resurfacing and treatment of skin roughness, hyperpigmentation, and wrinkles and scars on both facial and body. The FSR handpiece contains a matrix of 112 tiny electrodes, allowing for the first time simultaneous fractional micro-ablation of the epidermis, together with volumetric heating of 100% of the dermis. This technology provides the capability to differentiate between micro-ablation and dermal heating which appears to be the optimal multi-layer treatment to affect aging skin and atrophic acne scars.3Deep Shaper Handpiece Major innovation in RF skin tightening, body shaping and contouring, and cellulite treatment for large body areas. The handpiece’s unique engineered electrode surface is 40.7 cm2 allowing for shorter treatment times (20 minute abdomen treatment, 30 minute cellulite treatments for the thighs and buttocks). Deeper, controlled energy penetration tightens and firms the skin by stimulating the body’s natural collagen renewal process, providing better and more effective results.
Active Optical Systems Optima 518 IPL Laser
Handpiece (Standard):Multipurpose Wavelength Mark-II Handpiece (Optional):Facial Treatments Pulse Interval/Repetition Rate:0.5 – 2 Seconds Maximum Output Treatment Pattern:22 Joule /cm 2 Output Power:11-31 Joule / cm 2 , up to 4000 W Cooling System:Improved Air Cooling Control:Advanced Software Interface Lamp’s Life Span:200,000 Flashes (minimum) Treatment Area/Spot Size:15 x 50 mm, (7.5 cm 2) Wavelength:420 – 1,100 nm Weight:88.18 lbs (40Kg) (including stand) Dimensions:17.32 inches x 17.72 inches x 39.37 inches (44cm x 45cm x 100cm) Mains:220-230 VAC, 50/60 Hz; 100-120 VAC, 50/60 Hz Max Mains Power:600 VA Treatments Variety: Skin Rejuvenation Pigmentation Treatment Acne Treatment Hair Removal Hair Removal – Deep Follicles Hair Removal – Sensitive Skin Vascular (Facial) Treatment Tattoo Removal The Laser uses 12 preset programs. The programs are set in a consecutive, energy intensity increasing order, as specified by the tables of settings, covering all types of hair and skin combinations to be treated. 12 Programs 1 – Very Dark Skin, Fitzpatrick Skin Type IV 2 – Dark Skin, Fitzpatrick Skin Type IV 3 – Dark Skin, Fitzpatrick Skin Type III 4 – Dark Skin, Fitzpatrick Skin Type III 5 – Medium Skin, Fitzpatrick Skin Type II 6 – Medium Skin, Fitzpatrick Skin Type II 7 – Light Skin, Fitzpatrick Skin Type II 8 – Light Skin, Fitzpatrick Skin Type I 9 – Very Light Skin, Fitzpatrick Skin Type I 10 – Very Light Skin, Fitzpatrick Skin Type I 11 – Very Light Skin, Fitzpatrick Skin Type I 12 – High Power, Fitzpatrick Skin Type IOptima-518-Classic Active Optical Systems Optima 518 IPL LaserThe Optima – 518 Classic was designed to answer the needs of sophisticated practitioners who want to provide state of the art treatment to their patients on one hand, based on proven and tested treatment protocols and on the other hand to have the ability to reach new and improved protocols by conducting innovative clinical investigations.The Optima – 518 Classic, based on active’s GEM-PL technology, sets the pulse pattern according to the selected treatment type, skin color, skin photosensitivity and treatment depth. The treatment protocols and different pulse patterns take into account the tissue’s TRT (Thermal Relaxation Time) and the combined knowledge accumulated from thousands of treatments done during the years and clinical investigations done to confirm the findings.New Handpiece Design The Optima – 518 Classic is the first model to use the new Mark II which enables a multipurpose handpiece: * Faster treatments – up to 0.5 Seconds Between pulses. * Real-time handpiece temperature control. * Contemporary and stylish design. * Light weight design – 25% less weight to improve the therapists’ comfort.Research program for clinical investigations, the self setting program allows researchers to set the treatment’s parameters according to their needs. Allowing advanced research with the device. The energy levels in the self setting program can reach 31J cm 2 with high intensity of 4000 W.Approvals * CE MDD Intl. Medical Standard * FDA U.S. Safety Standard * ISO-13485 Med. Production STD * IEC 60-601-1 Medical Safety STD * CFS Gov. Health Approval * CSA Can. & U.S. Safety App * TGA Australian health STD.
Lutronic Clarity Long Pulsed Alexandrite & Nd:YAG LaserRESULTS YOU CAN SEEThe ability to choose from 755 nm or 1064 nm wavelength provides your clinic a highly versatile system. The CLARITY uses proven technology with advanced features to provide visible results in a single treatment.ALEX Toning InnerLift Technique Genesis Technique Dual Fractional Technique COCO TechniqueSale – Lutronic Clarity Long Pulsed Alexandrite & Nd:YAG Laser MULTIPLE TREATMENT OPTIONSAPPLICATIONS Lutronic Clarity Long Pulsed Alexandrite & Nd:YAG LaserHair removal Skin tightening & firming Skin rejuvenation Large pores Blackheads Pigmented lesions Epidermal pigments Vascular lesions Facial telangiectasia Flushing Rosacea Leg veins Warts Onychomycosis And more…Lutronic Clarity Long Pulsed Alexandrite & Nd:YAG Laser with Dual Fractional Feature The Dual Wavelength Solution that Delivers Suitable Parameters with an Incredible Fast Treatment SpeedLutronic CLARITY is a dual wavelength platform combining long pulsed 755 nm Alexandrite and 1064 nm Nd:YAG. CLARITY’s advanced features enable treatment versatility and greater speed. SPEEDSale – Lutronic Clarity Long Pulsed Alexandrite & Nd:YAG LaserA high repetition rate and large treatment spot empower CLARITY users to permanently reduce unwanted hair with unprecedented speed, allowing clinics to perform more treatments and maximise their return on investment. EFFICACYCLARITY’s highly efficacious treatment options are rooted in the delivery of high peak power laser energy, in short pulse widths. The Flat Top beam profile provides consistent treatment for more predictable outcomes. VERSATILITYCLARITY’s dual wavelengths permits the treatment of all skin types and its advanced features provide multi-treatment opportunities enabling clinics to treat a larger range of applications; physicians may permanently reduce unwanted hair, improve the appearance of pigmented and vascular lesions, and rejuvenate the skin with multiple treatment options.“The worldwide 1st dual fractional feature by one handpiece supports a more reliable and gentle procedure.” CONVENIENCESingle fiber delivery with 9 spot size choices ranging up to 20 mm with both wavelengths for ease of use, increased treatment speeds and reduced costs across multiple applications Choice of epidermal protection and comfort with built-in Intelligent Cooling Device™(ICD) or air coolingHYBRID COOLINGHybrid Cooling (Optional), available on ICD model, provides optional dual cooling for added patient comfort.Cutera Xeo with Full Nd Yag and Low PulsesCutera Xeo Laser HandpiecesPearl Fractional Handpiece Features
  • Pearl Fractional has deep ablation and controlled thermal zone delivers maximum single-treatment results with less patient discomfort, downtime and risk than CO2
  • Indicated for moderate to severe photoaging
  • The 2790 nm wavelength (YSGG) controls thermal damage to maximize ablation while maintaining thermal stimulation and coagulation
  • Controlled thermal zone minimizes risk of PIH and other complications
  • Single treatment results are possible because our large 300 micron spot size ablates enough tissue in one pass
  • Wound healing causes increased fibroblast activity and long term collagen deposition. Improvement is realized over six month period.
CoolGlide Nd Yag Laser Handpiece Features and SpecificationsThe CoolGlide laser is the first laser cleared for permanent hair reduction in all skin types.
  • Treat all skin types (I-VI) including tanned skin in the summer
  • Patented PowerFlex™ technology provides fast treatments and high efficacy; allows independent control of fluence, pulse duration and repetition rates to tailor your treatment parameters
  • Copper cooling provides the most efficient method of cooling for optimal skin protection and comfort
  • Large spot size (10 mm) for maximum speed and optimal penetration at all follicle depths
  • Wavelength: 1064 nm
  • Fluence / Energy: Up to 300 J/cm2
  • Spot Size: 3 mm, 5 mm, 7 mm, 10 mm
  • Pulse Width: 0.1 – 30 msec or 10 – 100 msec
  • Repetition Rate: 2 Hz to 10 Hz
Laser Genesis Handpiece FeaturesLaser Genesis is a staple of skin care for every doctor’s practice. It is a multi-purpose, all season, all skin type solution for overall skin health
  • Cutera Xeo Laser has a 1064 nm wavelength, combined with our patented microsecond technology, protects the epidermis, targets microvasculature and stimulates collagen production
  • Improves wrinkles by gently heating the dermis; corrects diffuse redness, rosacea; smooths skin texture, shrinks pore size
  • Peer reviewed journal shows evidence of erythema reduction and new collagen formation in the papillary dermis (Archives of Dermatology, Nov 2004)
  • No downtime, minimal discomfort, no disposables.
LimeLight Handpiece Features and SpecificationsLimeLight is the most versatile, programmable device for treating vascular and pigmented lesions.
  • Three distinct preset programs (520-1100 nm) provide excellent hemoglobin and melanin absorption for uniform treatments and ease of use
  • Clinical versatility permits treatment of multiple indications, including both low and high contrast pigmentation
  • Features such as the industry’s fastest treatment speed and adjustable temperature control provide clinical versatility
  • Only company with real-time calibration; this ensures accurate and consistent power output during treatment for reproducible results and patient safety
  • Program A – 520 nm Filter – Fine Telangiectasia
  • Program B – 560 nm Filter – Telangiectasia, Pigment
  • Program C – 580 nm Filter – Solar Lentigines
  • Spot Size: 10 mm x 30 mm
  • Cooling: 5 °C, 10 °C or 20 °C
  • Fluence / Energy: 5-30 J/cm2
  • Repetition Rate: 2 Hz
AcuTip Handpiece FeaturesAcuTip delivers optimal results with targeted focal treatments of pigmented and vascular lesions–with no risk to surrounding skin.
  • Small tip allows aggressive pinpoint treatments – without compromising safety
  • Selective wavelengths (500-635 nm) with short pulse durations deliver a powerful focal treatment
  • Ideal for treatment of both low and high contrast pigmented lesions
  • As powerful as Q-switched lasers for epidermal pigmentation; low risk of associated PIH
Pearl Handpiece FeaturesPearl delivers superior results in fewer treatments with less patient downtime than with non-fractional ablative lasers.
  • Indicated for fine wrinkles, dyschromia, skin tone and texture
  • Full epidermal renewal is achieved with YSGG’s 2790 nm wavelength
  • Patients receive 1-2 treatments without weeping and oozing and recover in 3-4 days
Excel Handpiece FeaturesThe first clinically effective long-pulsed Nd:YAG laser for both facial and lower extremity vascular lesions.
  • The Excel safely and effectively treats discrete vessels, high pressure vessels and deep veins
  • Patented PowerFlex™ technology provides fast treatments and high efficacy; allows independent control of fluence, pulse duration and repetition rates to tailor your treatment parameters
  • Contact copper cooling provides the most efficient method of cooling for optimal skin protection and comfort
  • The “clearview” handpiece feature prevents vessel closure due to contact pressure
  • Easy on-the-fly spot size adjustment (3, 5, 7 mm) facilitates optimal selection for safety and results
Titan V HP (small areas) + Titan XL HP (large areas) Handpieces Features and SpecificationsTitan is the most researched and peer-reviewed infra-red solution for deep dermal heating of all skin.
  • Titan’s light source generates energy from 1100 to 1800 nm for safe and effective volumetric heating of the dermis
  • Titan candidates are often patients not yet ready for surgery
  • When combined with other non-ablative procedures that improve conditions such as dyschromia, Titan’s toning effect enhances overall results
  • Wavelength: 1100 – 1800 nm Infrared
  • Fluence / Energy: 5 to 65 J/cm2
  • Spot Size
    • Titan V – 10 mm x 15 mm
    • Titan XL – 10 mm x 30 mm
  • Tx Cycle: 4 to 10 Seconds
ProWave Hair Removal Handpiece Features and SpecificationsProWave has multiple wavelength technology switches modes from Alexandrite to Diode to near Nd:YAG for maximum results, safety and versatility—all in a single high speed device.
  • ProWave (770-1100 nm), combines unrivaled treatment speed with optimal results and safety. Maximum versatility is achieved multiple wavelength technology enabling treatment modes from Alexandrite to Diode to near Nd:YAG
  • Clinical studies showed > 80% hair reduction six months post three treatments
  • Wavelength: 770 – 1100 nm
  • Fluence: 5 to 35 J/cm2
  • Spot Size: 10 mm x 30 mm
  • Repetition Rate: 2 Hz
Cutera Xeo Laser System Specifications Cutera Xeo with Full Nd Yag and Low Pulses
  • Dimensions: 12″ W x 19″ D x 35″ H
  • System Cooling: Internal, self-contained
  • Electrical Info
    • 115 V | 60 Hz | 20A
    • 230 V | 60 Hz | 20A | 1 Phase
  • Weight: 135 lbs
Active Optical Systems Optima 518 IPL LaserHandpiece (Standard):Multipurpose Wavelength Mark-II Handpiece (Optional):Facial Treatments Pulse Interval/Repetition Rate:0.5 – 2 Seconds Maximum Output Treatment Pattern:22 Joule /cm 2 Output Power:11-31 Joule / cm 2 , up to 4000 W Cooling System:Improved Air Cooling Control:Advanced Software Interface Lamp’s Life Span:200,000 Flashes (minimum) Treatment Area/Spot Size:15 x 50 mm, (7.5 cm 2) Wavelength:420 – 1,100 nm Weight:88.18 lbs (40Kg) (including stand) Dimensions:17.32 inches x 17.72 inches x 39.37 inches (44cm x 45cm x 100cm) Mains:220-230 VAC, 50/60 Hz; 100-120 VAC, 50/60 Hz Max Mains Power:600 VA Treatments Variety: Skin Rejuvenation Pigmentation Treatment Acne Treatment Hair Removal Hair Removal – Deep Follicles Hair Removal – Sensitive Skin Vascular (Facial) Treatment Tattoo Removal ACTIVE OPTICAL SYSTEMS OPTIMA 518 IPL LASERr uses 12 preset programs. The programs are set in a consecutive, energy intensity increasing order, as specified by the tables of settings, covering all types of hair and skin combinations to be treated. 12 Programs 1 – Very Dark Skin, Fitzpatrick Skin Type IV 2 – Dark Skin, Fitzpatrick Skin Type IV 3 – Dark Skin, Fitzpatrick Skin Type III 4 – Dark Skin, Fitzpatrick Skin Type III 5 – Medium Skin, Fitzpatrick Skin Type II 6 – Medium Skin, Fitzpatrick Skin Type II 7 – Light Skin, Fitzpatrick Skin Type II 8 – Light Skin, Fitzpatrick Skin Type I 9 – Very Light Skin, Fitzpatrick Skin Type I 10 – Very Light Skin, Fitzpatrick Skin Type I 11 – Very Light Skin, Fitzpatrick Skin Type I 12 – High Power, Fitzpatrick Skin Type IActive Optical Systems Optima 518 IPL LaserOptima-518-Classic The Optima – 518 Classic was designed to answer the needs of sophisticated practitioners who want to provide state of the art treatment to their patients on one hand, based on proven and tested treatment protocols and on the other hand to have the ability to reach new and improved protocols by conducting innovative clinical investigations.The Optima – 518 Classic, based on active’s GEM-PL technology, sets the pulse pattern according to the selected treatment type, skin color, skin photosensitivity and treatment depth. The treatment protocols and different pulse patterns take into account the tissue’s TRT (Thermal Relaxation Time) and the combined knowledge accumulated from thousands of treatments done during the years and clinical investigations done to confirm the findings.ACTIVE OPTICAL SYSTEMS OPTIMA 518 IPL LASERNew Handpiece Design The Optima – 518 Classic is the first model to use the new Mark II which enables a multipurpose handpiece: * Faster treatments – up to 0.5 Seconds Between pulses. * Real-time handpiece temperature control. * Contemporary and stylish design. * Light weight design – 25% less weight to improve the therapists’ comfort.Research program for clinical investigations, the self setting program allows researchers to set the treatment’s parameters according to their needs. Allowing advanced research with the device. The energy levels in the self setting program can reach 31J cm 2 with high intensity of 4000 W.ACTIVE OPTICAL SYSTEMS OPTIMA 518 IPL LASER Approvals * CE MDD Intl. Medical Standard * FDA U.S. Safety Standard * ISO-13485 Med. Production STD * IEC 60-601-1 Medical Safety STD * CFS Gov. Health Approval * CSA Can. & U.S. Safety App * TGA Australian health STD.
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
You're viewing: Eclipse Aesthetics Equinox Co2 2014 For Sale $8,200.00
Add to cart
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
  • Attributes
  • Custom attributes
  • Custom fields
Click outside to hide the comparison bar
Compare
Shopping cart close