| Description | 2014 Eclipse Aesthetics Equinox Co2; Manufactured 01/21/2014; Excellent Cosmetic and Operating Condition, Single Owner, Received Full Maintenance and Certification That It is Operating Perfectly at the Hightest Energy Levels from Licensed Technician on 09/17/2017, Record Available Upon Request; Includes: (2) Keys, Footswitch, Interlock, Operator Manual, Warning Sign, and 90 Day Warranty.km | The PURE+ is offered in two configurations:FSR + TC: Fixed FSR handpiece + one exchangeable connector suitable for all TC handpieces: iFine, Small and Large
TC Complete: Two exchangeable connectors on each side, suitable for all TC handpieces: iFine, Shaper, Small and LargeThe iFine treatment Handpiece –
specially engineered to target fine lines and wrinkles found in the delicate thin skin areas around the eyes, providing:
Smoother, tighter skin around the eyes.
Reduced under eye sagging and improved eye contour.
Reduced hooding to reveal more of the eyelid.
More youthful, less tired looking eyes.
Softening of fine line enabling easier application of make-up. | New Handpiece Design The Optima – 518 Classic is the first model to use the new Mark II which enables a multipurpose handpiece:
* Faster treatments – up to 0.5 Seconds Between pulses.
* Real-time handpiece temperature control.
* Contemporary and stylish design.
* Light weight design – 25% less weight to improve the therapists’ comfort. | This system allows not only a quantitative nutational infrasonic infiltration, but also a nutational infrasonic liposculpture.Manufactured for a safe liposculpture respecting the non-fatty tissues. | Candela GentleMAX ProEstablished in 1970, Candela is a leading US-based global medical aesthetic device company with headquarters in Wayland, Massachusetts. The company’s technologies enable physicians to provide advanced energy-based solutions for a broad range of medical-aesthetic applications including benign vascular and pigmented lesions, scars, hair removal, facial resurfacing, wrinkle reduction, women’s health treatments, tattoo removal, acne, leg veins, cellulite, and body shaping. | Energist NeoGen PSR offers a range of treatment options, and delivers the unparalleled results your patients expect: The unique energy delivered by NeoGen is non fractionated and not dependant on a chromophore for its uptake. This provides uniform energy absorption, ensuring consistent treatment of the skin, and at high energies supporting significant tightening. |
| Content | Eclipse Aesthetics Equinox Co2Laser Type:Fractionated Co2
Wavelength:10,600nm
Power Output (continuous):1-30 W, 75 W
Power Supply:100-240V, 50/60Hz, 800 W
Pulse Energy:1-300mJ
Spot Density:2-40, 100%
Scan Area Size:From 1x1mm to 15x15mm
Scan Area Shapes:Square, Triangle, Circle (multiple sizes)
Operation Mode:Stamp, Moving (Auto ON)
Length of Pulse:0.05 – 10ms
Display:Color LCD touch screen
Weight:35kg
Beam Divergence:<7mrad A Fractional CO2 Laser
Provides highest quality treatments for fine lines and wrinkles, scar revisions, acne scars, hyperpigmentation.CO2 Laser Skin Resurfacing Eclipse Aesthetics Equinox Co2
CO2 laser skin resurfacing precisely removes the outer layers of damaged and aged skin to reveal the underlying layer of beautiful, smooth, and younger looking skin. CO2 laser technology is the most common used skin resurfacing surgery today. The latest CO2 laser resurfacing technology uses beams that are scattered or pulsed at a very rapid rate.
This method minimizes the exposure of heat that your skin undergoes which removes heat damage your skin would be exposed to as well as decreases after surgery recovery time. It also allows a higher power CO2 laser to be used to reach deeper tissue and more pronounced creases and wrinkles. Benifits of CO2 laser skin resurfacing include deeper scar and damaged tissue removal. By removing the damaged outer layer of skin, CO2 laser skin resurfacing treatment can slow down and reverse the process of aging. Further CO2 laser treatments include uneven pigmentation, precancerous spots, photodamage, and many other skin imperfections and benign lesions.The EQUINOX fractional CO2 laser can be used to effectively treat fine lines and wrinkles, acne and surgical scars, skin pigmentation and discoloration, sun damage, pre-cancerous as well as benign lesions and uneven skin texture. EQUINOX, in the hands of an experienced Plastic Surgeon, delivers dramatic, visible improvement in a single 30 minute treatment session. EQUINOX can resurface compromised or damaged skin in order to provide rejuvenation with excellent improvement of fine lines and wrinkles, acne, surgical scars, skin pigmentation or discoloration, sun damage, pre-cancerous and benign lesions. | ENDYMED PURE PLUS Input Power:100-120V, 50-60Hz, 2A or 220-240V, 50-60Hz, 1A
Power Consumption:220 W
Fuses:2 x 1.6A for 220V; 2 x 3.15A for 110V
Output Power:Up to 50 Watts
Output Frequency:1MHz
Working Temperature:+10°C – +25°C
Dimensions:(H x W x D) 600 x 305 x 365 mm
Weight:10 kg
GOOD THINGS COMES IN SMALL PACKAGES THE PURE+
The Pure+ by Endymed Pure Plus, powered by our FDA cleared, patented 3DEEPRF technology. The PURE+ offers professional grade Fractional Skin Resurfacing and superior body, facial and neck tightening and contouring treatments, all on one easy to use, compact platform. The PURE+ offers complete flexibility with exchangeable treatment handpieces one PURE+ console can be configured any way you like to provide you and your clients with the most effective and popular treatments available today.The PURE+ is offered in two configurations:FSR + TC: Fixed FSR handpiece + one exchangeable connector suitable for all TC handpieces: iFine, Small and Large
TC Complete: Two exchangeable connectors on each side, suitable for all TC handpieces: iFine, Shaper, Small and LargeThe iFine treatment Handpiece –
specially engineered to target fine lines and wrinkles found in the delicate thin skin areas around the eyes, providing:
Smoother, tighter skin around the eyes.
Reduced under eye sagging and improved eye contour.
Reduced hooding to reveal more of the eyelid.
More youthful, less tired looking eyes.
Softening of fine line enabling easier application of make-up.3Deep Small-Medium Handpiece
Designed to treat wrinkles and lax skin on the face, neck and upper body.3Deep Fractional Skin Resurfacing Handpiece
Specially designed for fractional skin resurfacing and treatment of skin roughness, hyperpigmentation, and wrinkles and scars on both facial and body. The FSR handpiece contains a matrix of 112 tiny electrodes, allowing for the first time simultaneous fractional micro-ablation of the epidermis, together with volumetric heating of 100% of the dermis. This technology provides the capability to differentiate between micro-ablation and dermal heating which appears to be the optimal multi-layer treatment to affect aging skin and atrophic acne scars.3Deep Shaper Handpiece
Major innovation in RF skin tightening, body shaping and contouring, and cellulite treatment for large body areas. The handpieces unique engineered electrode surface is 40.7 cm2 allowing for shorter treatment times (20 minute abdomen treatment, 30 minute cellulite treatments for the thighs and buttocks). Deeper, controlled energy penetration tightens and firms the skin by stimulating the bodys natural collagen renewal process, providing better and more effective results. | Active Optical Systems Optima 518 IPL LaserHandpiece (Standard):Multipurpose Wavelength Mark-II
Handpiece (Optional):Facial Treatments
Pulse Interval/Repetition Rate:0.5 – 2 Seconds
Maximum Output Treatment Pattern:22 Joule /cm 2
Output Power:11-31 Joule / cm 2 , up to 4000 W
Cooling System:Improved Air Cooling
Control:Advanced Software Interface
Lamp’s Life Span:200,000 Flashes (minimum)
Treatment Area/Spot Size:15 x 50 mm, (7.5 cm 2)
Wavelength:420 – 1,100 nm
Weight:88.18 lbs (40Kg) (including stand)
Dimensions:17.32 inches x 17.72 inches x 39.37 inches (44cm x 45cm x 100cm)
Mains:220-230 VAC, 50/60 Hz; 100-120 VAC, 50/60 Hz
Max Mains Power:600 VA
Treatments Variety:
Skin Rejuvenation
Pigmentation Treatment
Acne Treatment
Hair Removal
Hair Removal – Deep Follicles
Hair Removal – Sensitive Skin
Vascular (Facial) Treatment
Tattoo Removal
The Laser uses 12 preset programs. The programs are set in a consecutive, energy intensity increasing order, as specified by the tables of settings, covering all types of hair and skin combinations to be treated.
12 Programs
1 – Very Dark Skin, Fitzpatrick Skin Type IV
2 – Dark Skin, Fitzpatrick Skin Type IV
3 – Dark Skin, Fitzpatrick Skin Type III
4 – Dark Skin, Fitzpatrick Skin Type III
5 – Medium Skin, Fitzpatrick Skin Type II
6 – Medium Skin, Fitzpatrick Skin Type II
7 – Light Skin, Fitzpatrick Skin Type II
8 – Light Skin, Fitzpatrick Skin Type I
9 – Very Light Skin, Fitzpatrick Skin Type I
10 – Very Light Skin, Fitzpatrick Skin Type I
11 – Very Light Skin, Fitzpatrick Skin Type I
12 – High Power, Fitzpatrick Skin Type IOptima-518-Classic Active Optical Systems Optima 518 IPL LaserThe Optima – 518 Classic was designed to answer the needs of sophisticated practitioners who want to provide state of the art treatment to their patients on one hand, based on proven and tested treatment protocols and on the other hand to have the ability to reach new and improved protocols by conducting innovative clinical investigations.The Optima – 518 Classic, based on active’s GEM-PL technology, sets the pulse pattern according to the selected treatment type, skin color, skin photosensitivity and treatment depth. The treatment protocols and different pulse patterns take into account the tissue’s TRT (Thermal Relaxation Time) and the combined knowledge accumulated from thousands of treatments done during the years and clinical investigations done to confirm the findings.New Handpiece Design The Optima – 518 Classic is the first model to use the new Mark II which enables a multipurpose handpiece:
* Faster treatments – up to 0.5 Seconds Between pulses.
* Real-time handpiece temperature control.
* Contemporary and stylish design.
* Light weight design – 25% less weight to improve the therapists’ comfort.Research program for clinical investigations, the self setting program allows researchers to set the treatment’s parameters according to their needs. Allowing advanced research with the device. The energy levels in the self setting program can reach 31J cm 2 with high intensity of 4000 W.Approvals
* CE MDD Intl. Medical Standard
* FDA U.S. Safety Standard
* ISO-13485 Med. Production STD
* IEC 60-601-1 Medical Safety STD
* CFS Gov. Health Approval
* CSA Can. & U.S. Safety App
* TGA Australian health STD. | Euromi Eva SP7 Lipomatic Liposuction Unit{tab System composition}- 15-inch touch screen that can be angled from 0 to 45 degrees
- Excellent visibility for the surgeon during the procedure
- Control panel with touch screen allowing the infiltrated and aspirated zones to be visualized
- Control of the volume infiltrated and aspirated millimeter per millimeter in the zone selected on the touch screen
- The n.i.l technique ensures an homogeneous infiltration with a constant pressure, whatever the fat density
- Infiltration and aspiration data recording on USB flash memory
- Compatible with the lipofilling material n.l.f System 1 & 2
- In compliance with the European standards – CE marking
{tab Advantages}- Preservation of non-fatty tissues
- Very easy to change zones thanks to the mapping of the different zones on the touch screen
- Shorter post-procedure recovery
- Less traumatising (fewer hematomas and major reduction of ecchymosis and oedemas)
- Less painful for the patient
- Infrasonic frequency (25 Hz) comfortable for the patient
{tab Accessories} Euromi Eva SP7 Lipomatic Liposuction Unit- Evamatic/evamatic
- Control panel with touchscreen
- Quantitative infiltration system
- High-speed aspirator
- Complete set of cannulas
- Accessories
The Eva sp 7 allows a quantitative nutational infrasonic infiltration and also a nutational infrasonic liposculpture.Manufactured for a safe liposculpture respecting the non-fatty tissues, the system is entirely digitalizedIt complies with European standards (CE marking) and is compatible with N.L.F. System, our kit for lipofilling.This product is a medical device intended for use by qualified healthcare professionals.If you are a healthcare professional and would like more information about this product, please complete the form opposite.If you are an individual, for more information, please refer to your healthcare professional.Special features of Eva sp 7:- The screen provides excellent visibility for the surgeon during the procedure: infiltrated and aspirated areas.
- In addition, changing zones is very easy thanks to the mapping of the different zones on the touch screen. This screen allows you to control the volume infiltrated ml / ml in the zone selected on it.
- Infiltration and aspiration data can be saved on a USB drive.
| 2017 Candela GentleMAX Pro Device DetailsThe Candela GentleMax Pro yields high energy, subjecting patients to fewer laser pulses providing faster treatment times with the 24mm spot size, the largest spot found on any hair removal laser. Candela’spatented Dynamic Cooling Devise (DCD) technology protects the upper layers of skin with cooling bursts of cryogen. DCD cooling offers optimal treatment with minimal side effects.| Distributor | Candela |
|---|
| Manufacturer | Candela |
|---|
| Model | GentleMAX Pro |
|---|
| Manufactured Year | 2017 |
|---|
| Specific Equipment Type | Dual Wavelength Laser |
|---|
| Sale Price | 12500 |
|---|
| Treatments Performed | Hair Removal, Vascular, Pigmentation
Skin Rejuvenation
Skin Tightening |
|---|
| Handpieces | Standard Handpiece DCD 12-18mm , Large Spot Size Handpiece DCD 22-24mm |
|---|
| Shot Counts | None |
|---|
| Wavelengths | 755nm
1064nm |
|---|
| Consumables used by device | Windows, Distance Gauges |
|---|
| Consumables with purchase | 3 x Operator goggles, 1 x patient goggles, distance gauges, windows |
|---|
| Annual Service Price | Servicing available through Candela |
|---|
| Service Contract Price | $11,000 per annum |
|---|
| Additional Information | Any additional information can be sent on request |
|---|
| |
|---|
Treatments:2017 Candela GentleMAX Pro Device Details- Hair Removal
- Beard Bumps
- Facial Lesions
- Fine Lines and Wrinkles
- Leg Veins
- Skin Tightening
- Vascular Lesions
- Warts
- Skin Rejuvenation
- Hemangiomas
- Birthmarks
- Freckles
- Melasma
- Mevus of Ota
- Pigmented Lesions
- Sun / Age Spots
The Candela GentleMax Pro yields high energy, subjecting patients to fewer laser pulses providing faster treatment times with the 24 mm spot size, the largest spot found on any hair removal laser.Fast – With 24 mm spot size and repetition rates up to 2 Hz, the The Candela GentleMax Pro yields high energy, subjecting patients to fewer laser pulses providing faster treatment times with the 24 mm spot size, the largest spot found on any hair removal laser. It has two wavelengths, the 755 Alexandrite and the 1064 ND:yag, allowing you to offer many treatment options.Candela’s patented Dynamic Cooling Devise (DCD) technology protects the upper layers of skin with cooling bursts of cryogen. DCD cooling offers optimal treatment with minimal side effects. offers fast treatment times with it’s spot size.Powerful – 26,333 watts peak power, capable of delivering fluences up to 100 J/cm² for vascular applications, and hair removal energy in pulse duration as short as 3 ms for unparalleled treatment efficacies.Treats all skin types – Deep penetration with minimal scattering of laser energy makes the GentleMax Pro ideal for all skin types, particularly dark and tanned skin.Versatile – Non-ablative treatment, including fine lines and wrinkles, and for pseudofolliculitis barbae (PFB), or beard bumps, leg and facial veins.Patented Epidermal Cooling – Candela’s Dynamic Cooling Device represents an adjustable epidermal protection technology to maximize patient safety and comfort.Date of Manufacture – 2017Accessories Included with Purchase – Specialty 1.5, 3mm, 3x10mm Handpiece, 6, 8, 10, 12, 15, 18mm Handpiece, Full Set of Distance Gauges, Distance Gauge Case, Patient Eyewear, Treatment Goggles, Foot Pedal, Fiber Pole, System Key, System Interlock Key, Treatment Guidelines, and User Manual. | Energist NeoGen PSR LaserNeoGen PSR SystemNeoGen nitrogen plasma technology delivers controlled heating to the skin architecture stimulating a significant physiological response, without creating an open wound. Unlike ablative technologies there is no epidermal vaporisation or charring caused at time of treatment.
Unique TechnologyNeoGen converts nitrogen gas into plasma energy, the fourth state of matter. The plasma emerges from the handpiece in controlled pulses and rapid heating of tissue occurs as it gives up its unique thermal energy to tissue.
No Open WoundsThe treated photodamaged layers undergo a controlled thermal modification, while remaining intact, creating a natural dressing to provide protection and speed healing. at high energies the epidermis sheds, but only after a new, healthier skin architecture is formed beneath.
Treats the Whole Skin ArchitectureTreating the entire skin structure ensures optimal results as the entire surface is regenerated with associated neocollagenesis and neoelastogenesis. No islands of untreated skin remain. Clinical studies show significant tightening – Mean 22% improvement in upper eyelid tightening (JOCD 7, 169-179, 2008).
Eyelids and Periorbital TreatmentEnergist NeoGen PSR is the ideal option for the treatment of the upper and lower eyelids, as well as the wider periorbital region. Other technologies cannot be used in this area or deliver inconsistent results.
Long Lasting ResultsClinical studies show neocollagenesis and reduction in elastosis continuing for more than one year post treatment.The Proven Power of Plasma for Skin Regeneration Energist NeoGen PSR Laser• Unique technology – controlled pulses of nitrogen plasma energy
• Treats the whole skin architecture – no islands of untreated skin remain
• Deep Tissue Remodelling – epidermis acts as natural dressing post treatment
• Versatile – high or low energy treatment choices to fit your patients’ needs and lifestyle
• Precise – treat eyelids effectively with significant results
• Long-lasting effects – intense fibroblast activity supports continued regeneration.
• Consistent – non-fractionated and non-chromophore dependence assures uniform energy absorption
• Proven Plasma Skin Regeneration is supported by numerous IRB-controlled studies
TechnologyPlasma skin regeneration was introduced with a level of scientific and clinical testing never before seen in the industry:
• 3+ years of pre-clinical and clinical testing
• 16 separate studies
• more than 450 clinical study treatments –No scarring or Hypopigmentation noted in studies
• one year clinical histology
This level of testing is very rare in the industryEnergist NeoGen PSR uses a highly energized gaseous state known as plasma to produce a unique thermal profile to penetrate the superficial and deeper levels of the dermis to replace damaged collagen and encourage new collagen growth for new skin. Plasma is produced inside the handpiece through the combination of inert nitrogen gas and ultra-high frequency RF.The Energist NeoGen PSR is emitted in millisecond pulses; the longer the pulse, the more energy is delivered. Nitrogen molecules impact the skin’s surface and immediately transfer energy upon contact. When the nitrogen plasma impacts the skin surface, energy is immediately transferred to the tissue. Oxygen is purged from the skin surface by the plasma, preventing carbonisation. The energy delivered to tissue ranges from 1 – 4 Joules and is user-adjustable. The repetition rate of the plasma pulses can also be controlled, and ranges from 1 – 2.5 Hertz.Specifications Energist NeoGen PSR| Power: | 100 – 120 / 230 Vrms – 50/60 Hz – 650 Va | | Energy Output: | Pulsed nitrogen plasma – 1-4 Joules. | | Repetition Rate: | 1.0 – 2.5Hz | | Dimensions: | 470 x 430 x 1060mm | | Gas Requirement: | Medical Grade Nitrogen | | System Weight: | 18kg/40lb | | Trolley Weight: | 25kg/55lb (excludes gas tank) | | Ambient Environment: | 0 to 40 celsius | | Relative Humidity: | 30 to 75% | | atmospheric pressure: | 700 to 1600 hpa |
|
Reviews
There are no reviews yet.