PERKASA MEDICAL

Free shipping worldwide. Orders over $200
Availability: In Stock

Cutera Excel HR 1064 755 Hair Removal System For Sale

$9,800.00

Superior, Comfortable Laser Hair Removal

Laser Hair Removal – An In-demand Procedure

excel HR combines a high-power 755 nm Alexandrite laser and Cutera’s proven long-pulse 1064 nm Nd:YAG laser for safe, effective high-volume hair removal on all skin types. The combination of wavelengths not only allows for effective hair removal, but is also a solution for epidermal pigmented lesions, vascular lesions and Cutera’s signature laser genesis skin revitalization procedure.

Other people want this. 15 people have this in their carts right now.

Description

Cutera Excel HR 1064 755 Hair Removal System

Alexandrite
Wavelength:755 nm
Maximum Energy:53J
Pulse Duration:3 ms
Spot Size:5-18 mm
Repetition Rate:2 Hz

Nd Yag
Wavelength:1064 nm
Maximum Energy:80J
Pulse Duration:0.1 – 300 ms
Spot Size:3-12 mm
Repetition Rate:Up to 10 Hz
Cooling:Contact Sapphire
Aiming Beam:635 nm
Dimensions:35″ H x 12″ W x 24″ D
Electricial:200-240 VAC, 50/60 Hz, 20A/30A

Cooling:Contact Sapphire
Aiming Beam:635 nm
Dimensions:35″ H x 12″ W x 24″ D
Electricial:200-240 VAC, 50/60 Hz, 20A/30A
Superior, Comfortable Laser Hair Removal
Laser Hair Removal  An In-demand Procedure
Global hair removal procedures are growing at a rapid pace. Laser hair removal has been among the top non-surgical procedures according to the American Society of Aesthetic Plastic Surgery and procedure revenue is anticipated to go to $1.35B by 20221. The industry often refers to laser hair removal as a gateway procedure as it offers an entry point into the aesthetic market for patients and practitioners alike.

excel HR combines a high-power 755 nm Alexandrite laser and Cuteras proven long-pulse 1064 nm Nd:YAG laser for safe, effective high-volume hair removal on all skin types. The combination of wavelengths not only allows for effective hair removal, but is also a solution for epidermal pigmented lesions, vascular lesions and Cuteras signature laser genesis skin revitalization procedure.

excel HR Technology
Proven Wavelengths
excel HR combines the gold standard laser wavelengths for hair removal. The 755 nm Alexandrite laser is highly absorbed by melanin making it an ideal solution for finer hair on skin types I-III. Because of the high melanin absorption characteristics, it has also been proven to provide long-term results on epidermal pigmented lesions.

The 1064 nm Nd:YAG is the safest wavelength for permanent hair reduction on darker skin types and tanned skin. By selecting the appropriate spot size, this laser can also be used for treating facial and leg veins and perform laser genesis procedure.

truPulse Delivery with Index Matching
Unique to Cutera, the truPulse technology delivers constant, sustained energy throughout the pulse duration to ensure consistent performance and proven clinical outcomes for your patients.

excel HRs index matching delivery results in more efficient coupling of laser energy to target structures. Index matching allows backscattered light to escape, further protecting the epidermis from heat build-up while maintaining treatment efficacy.

Superior Contact Cooling
excel HR utilizes sapphire contact cooling to provide continuous cooling, maximizing your patients comfort and treatment safety.2 In a patient preference study that measured comfort and satisfaction for laser hair removal, 100% of the patients preferred excel HR over a comparable, competitive laser hair removal procedure.3

21st Century Laser Hair Removal System
Developed by the innovative leader in aesthetic laser technology, excel HR laser hair removal system provides advanced premium hair removal solutions for every skin type. Combining a new high-power 755 nm Alexandrite laser, and CUTERAs proven long-pulse 1064 nm Nd:YAG laser, coupled with the superiority of sapphire contact cooling, excel HR redefines modern laser hair removal.

This makes excel HR laser system an effective, safe and comfortable option for laser hair removal for the 21st century.

Applications Cutera Excel HR 1064 755 Hair Removal System
– Hair removal
– Benign pigmented lesion removal
– Veins, facial
– Veins, leg
– Laser Genesis

Reviews

There are no reviews yet.

Be the first to review “Cutera Excel HR 1064 755 Hair Removal System For Sale”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsCutera Excel HR 1064 755 Hair Removal System For Sale removeActive Optical Systems Optima 518 IPL Laser remove2018 Energist NeoGen PSR For Sale removeGE Logiq E R7 Portable Ultrasound Machine removeDeka Synchro Replay Laser Nd-Yag For Sale remove2019 Lumenis Splendor X- Laser Hair Removal For Sale remove
NameCutera Excel HR 1064 755 Hair Removal System For Sale removeActive Optical Systems Optima 518 IPL Laser remove2018 Energist NeoGen PSR For Sale removeGE Logiq E R7 Portable Ultrasound Machine removeDeka Synchro Replay Laser Nd-Yag For Sale remove2019 Lumenis Splendor X- Laser Hair Removal For Sale remove
Image
SKU
Rating
Price $9,800.00 $5,200.00 $17,500.00 $24,750.00 $6,800.00 $25,000.00
Stock
Availability
Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

DescriptionSuperior, Comfortable Laser Hair RemovalLaser Hair Removal – An In-demand Procedureexcel HR combines a high-power 755 nm Alexandrite laser and Cutera’s proven long-pulse 1064 nm Nd:YAG laser for safe, effective high-volume hair removal on all skin types. The combination of wavelengths not only allows for effective hair removal, but is also a solution for epidermal pigmented lesions, vascular lesions and Cutera’s signature laser genesis skin revitalization procedure.New Handpiece Design The Optima – 518 Classic is the first model to use the new Mark II which enables a multipurpose handpiece: * Faster treatments – up to 0.5 Seconds Between pulses. * Real-time handpiece temperature control. * Contemporary and stylish design. * Light weight design – 25% less weight to improve the therapists’ comfort.The Proven Power of Plasma for Skin Regeneration• Unique technology – controlled pulses of nitrogen plasma energy • Treats the whole skin architecture – no islands of untreated skin remain • Deep Tissue Remodelling – epidermis acts as natural dressing post treatment • Versatile – high or low energy treatment choices to fit your patients’ needs and lifestyle • Precise – treat eyelids effectively with significant results • Long-lasting effects – intense fibroblast activity supports continued regeneration. • Consistent – non-fractionated and non-chromophore dependence assures uniform energy absorption • Proven Plasma Skin Regeneration is supported by numerous IRB-controlled studies TechnologyLOGIQ e Needle Recognition Software Option which helps provide precise and accurate display of the needle, anatomy and motion even in Color and Power Doppler. This feature harnesses pattern recognition technology that recognizes and accurately reveals the structure of a needle within the anatomy, without distortion of the needle and compromising the target.

Deka Synchro Replay Laser Nd-Yag Standard Handpieces

– More than 10 selectable handpieces

– Different spotsizes available (2.5 – 24 mm)– Automatic spot recognition system– Ergonomic connector for air-cooling devices
Laser Hair Removal
Details:
  • Serial Number: SQEAY-19M-XXXXX (message for serial number)
  • System Total Shot Count: 560,693
  • Alex Shot Count: 221,437
  • YAG Shot Count: 339,256

Includes:

  • Handpiece and Delivery System
  • Square Spot Sizes: 2x2mm, 3x3mm, 5x5mm, 10x10mm, 14x14mm, 18x18mm, 20x20mm, 24x24, 27x27mm
  • Fiber Pole
  • Foot Switch
  • System Key
  • Operators Manual
  • 30 Day Parts and Labor Warranty
ContentCutera Excel HR 1064 755 Hair Removal SystemAlexandrite Wavelength:755 nm Maximum Energy:53J Pulse Duration:3 ms Spot Size:5-18 mm Repetition Rate:2 HzNd Yag Wavelength:1064 nm Maximum Energy:80J Pulse Duration:0.1 – 300 ms Spot Size:3-12 mm Repetition Rate:Up to 10 Hz Cooling:Contact Sapphire Aiming Beam:635 nm Dimensions:35″ H x 12″ W x 24″ D Electricial:200-240 VAC, 50/60 Hz, 20A/30ACooling:Contact Sapphire Aiming Beam:635 nm Dimensions:35″ H x 12″ W x 24″ D Electricial:200-240 VAC, 50/60 Hz, 20A/30A Superior, Comfortable Laser Hair Removal Laser Hair Removal  An In-demand Procedure Global hair removal procedures are growing at a rapid pace. Laser hair removal has been among the top non-surgical procedures according to the American Society of Aesthetic Plastic Surgery and procedure revenue is anticipated to go to $1.35B by 20221. The industry often refers to laser hair removal as a gateway procedure as it offers an entry point into the aesthetic market for patients and practitioners alike.excel HR combines a high-power 755 nm Alexandrite laser and Cuteras proven long-pulse 1064 nm Nd:YAG laser for safe, effective high-volume hair removal on all skin types. The combination of wavelengths not only allows for effective hair removal, but is also a solution for epidermal pigmented lesions, vascular lesions and Cuteras signature laser genesis skin revitalization procedure.excel HR Technology Proven Wavelengths excel HR combines the gold standard laser wavelengths for hair removal. The 755 nm Alexandrite laser is highly absorbed by melanin making it an ideal solution for finer hair on skin types I-III. Because of the high melanin absorption characteristics, it has also been proven to provide long-term results on epidermal pigmented lesions.The 1064 nm Nd:YAG is the safest wavelength for permanent hair reduction on darker skin types and tanned skin. By selecting the appropriate spot size, this laser can also be used for treating facial and leg veins and perform laser genesis procedure.truPulse Delivery with Index Matching Unique to Cutera, the truPulse technology delivers constant, sustained energy throughout the pulse duration to ensure consistent performance and proven clinical outcomes for your patients.excel HRs index matching delivery results in more efficient coupling of laser energy to target structures. Index matching allows backscattered light to escape, further protecting the epidermis from heat build-up while maintaining treatment efficacy.Superior Contact Cooling excel HR utilizes sapphire contact cooling to provide continuous cooling, maximizing your patients comfort and treatment safety.2 In a patient preference study that measured comfort and satisfaction for laser hair removal, 100% of the patients preferred excel HR over a comparable, competitive laser hair removal procedure.321st Century Laser Hair Removal System Developed by the innovative leader in aesthetic laser technology, excel HR laser hair removal system provides advanced premium hair removal solutions for every skin type. Combining a new high-power 755 nm Alexandrite laser, and CUTERAs proven long-pulse 1064 nm Nd:YAG laser, coupled with the superiority of sapphire contact cooling, excel HR redefines modern laser hair removal.This makes excel HR laser system an effective, safe and comfortable option for laser hair removal for the 21st century.Applications Cutera Excel HR 1064 755 Hair Removal System – Hair removal – Benign pigmented lesion removal – Veins, facial – Veins, leg – Laser GenesisActive Optical Systems Optima 518 IPL Laser
Handpiece (Standard):Multipurpose Wavelength Mark-II Handpiece (Optional):Facial Treatments Pulse Interval/Repetition Rate:0.5 – 2 Seconds Maximum Output Treatment Pattern:22 Joule /cm 2 Output Power:11-31 Joule / cm 2 , up to 4000 W Cooling System:Improved Air Cooling Control:Advanced Software Interface Lamp’s Life Span:200,000 Flashes (minimum) Treatment Area/Spot Size:15 x 50 mm, (7.5 cm 2) Wavelength:420 – 1,100 nm Weight:88.18 lbs (40Kg) (including stand) Dimensions:17.32 inches x 17.72 inches x 39.37 inches (44cm x 45cm x 100cm) Mains:220-230 VAC, 50/60 Hz; 100-120 VAC, 50/60 Hz Max Mains Power:600 VA Treatments Variety: Skin Rejuvenation Pigmentation Treatment Acne Treatment Hair Removal Hair Removal – Deep Follicles Hair Removal – Sensitive Skin Vascular (Facial) Treatment Tattoo Removal The Laser uses 12 preset programs. The programs are set in a consecutive, energy intensity increasing order, as specified by the tables of settings, covering all types of hair and skin combinations to be treated. 12 Programs 1 – Very Dark Skin, Fitzpatrick Skin Type IV 2 – Dark Skin, Fitzpatrick Skin Type IV 3 – Dark Skin, Fitzpatrick Skin Type III 4 – Dark Skin, Fitzpatrick Skin Type III 5 – Medium Skin, Fitzpatrick Skin Type II 6 – Medium Skin, Fitzpatrick Skin Type II 7 – Light Skin, Fitzpatrick Skin Type II 8 – Light Skin, Fitzpatrick Skin Type I 9 – Very Light Skin, Fitzpatrick Skin Type I 10 – Very Light Skin, Fitzpatrick Skin Type I 11 – Very Light Skin, Fitzpatrick Skin Type I 12 – High Power, Fitzpatrick Skin Type IOptima-518-Classic Active Optical Systems Optima 518 IPL LaserThe Optima – 518 Classic was designed to answer the needs of sophisticated practitioners who want to provide state of the art treatment to their patients on one hand, based on proven and tested treatment protocols and on the other hand to have the ability to reach new and improved protocols by conducting innovative clinical investigations.The Optima – 518 Classic, based on active’s GEM-PL technology, sets the pulse pattern according to the selected treatment type, skin color, skin photosensitivity and treatment depth. The treatment protocols and different pulse patterns take into account the tissue’s TRT (Thermal Relaxation Time) and the combined knowledge accumulated from thousands of treatments done during the years and clinical investigations done to confirm the findings.New Handpiece Design The Optima – 518 Classic is the first model to use the new Mark II which enables a multipurpose handpiece: * Faster treatments – up to 0.5 Seconds Between pulses. * Real-time handpiece temperature control. * Contemporary and stylish design. * Light weight design – 25% less weight to improve the therapists’ comfort.Research program for clinical investigations, the self setting program allows researchers to set the treatment’s parameters according to their needs. Allowing advanced research with the device. The energy levels in the self setting program can reach 31J cm 2 with high intensity of 4000 W.Approvals * CE MDD Intl. Medical Standard * FDA U.S. Safety Standard * ISO-13485 Med. Production STD * IEC 60-601-1 Medical Safety STD * CFS Gov. Health Approval * CSA Can. & U.S. Safety App * TGA Australian health STD.

2018 Energist NeoGen PSR

NeoGen PSR SystemNeoGen nitrogen plasma technology delivers controlled heating to the skin architecture stimulating a significant physiological response, without creating an open wound. Unlike ablative technologies there is no epidermal vaporisation or charring caused at time of treatment. Unique TechnologyNeoGen converts nitrogen gas into plasma energy, the fourth state of matter. The plasma emerges from the handpiece in controlled pulses and rapid heating of tissue occurs as it gives up its unique thermal energy to tissue. No Open WoundsThe treated photodamaged layers undergo a controlled thermal modification, while remaining intact, creating a natural dressing to provide protection and speed healing. at high energies the epidermis sheds, but only after a new, healthier skin architecture is formed beneath. Treats the Whole Skin ArchitectureTreating the entire skin structure ensures optimal results as the entire surface is regenerated with associated neocollagenesis and neoelastogenesis. No islands of untreated skin remain. Clinical studies show significant tightening – Mean 22% improvement in upper eyelid tightening (JOCD 7, 169-179, 2008). Eyelids and Periorbital TreatmentEnergist NeoGen PSR is the ideal option for the treatment of the upper and lower eyelids, as well as the wider periorbital region. Other technologies cannot be used in this area or deliver inconsistent results. Long Lasting ResultsClinical studies show neocollagenesis and reduction in elastosis continuing for more than one year post treatment.The Proven Power of Plasma for Skin Regeneration• Unique technology – controlled pulses of nitrogen plasma energy • Treats the whole skin architecture – no islands of untreated skin remain • Deep Tissue Remodelling – epidermis acts as natural dressing post treatment • Versatile – high or low energy treatment choices to fit your patients’ needs and lifestyle • Precise – treat eyelids effectively with significant results • Long-lasting effects – intense fibroblast activity supports continued regeneration. • Consistent – non-fractionated and non-chromophore dependence assures uniform energy absorption • Proven Plasma Skin Regeneration is supported by numerous IRB-controlled studies TechnologyPlasma skin regeneration was introduced with a level of scientific and clinical testing never before seen in the industry: • 3+ years of pre-clinical and clinical testing • 16 separate studies • more than 450 clinical study treatments –No scarring or Hypopigmentation noted in studies • one year clinical histology This level of testing is very rare in the industryEnergist NeoGen PSR uses a highly energized gaseous state known as plasma to produce a unique thermal profile to penetrate the superficial and deeper levels of the dermis to replace damaged collagen and encourage new collagen growth for new skin. Plasma is produced inside the handpiece through the combination of inert nitrogen gas and ultra-high frequency RF.The Energist NeoGen PSR is emitted in millisecond pulses; the longer the pulse, the more energy is delivered. Nitrogen molecules impact the skin’s surface and immediately transfer energy upon contact. When the nitrogen plasma impacts the skin surface, energy is immediately transferred to the tissue. Oxygen is purged from the skin surface by the plasma, preventing carbonisation. The energy delivered to tissue ranges from 1 – 4 Joules and is user-adjustable. The repetition rate of the plasma pulses can also be controlled, and ranges from 1 – 2.5 Hertz.Specifications  PSR 2018 Energist NeoGen PSR
Power:100 – 120 / 230 Vrms – 50/60 Hz – 650 Va
Energy Output:Pulsed nitrogen plasma – 1-4 Joules.
Repetition Rate:1.0 – 2.5Hz
Dimensions:470 x 430 x 1060mm
Gas Requirement:Medical Grade Nitrogen
System Weight:18kg/40lb
Trolley Weight:25kg/55lb (excludes gas tank)
Ambient Environment:0 to 40 celsius
Relative Humidity:30 to 75%
atmospheric pressure:700 to 1600 hpa

GE Logiq E R7 Portable Ultrasound Machine

The NextGen LOGIQ combines the high performance of a console system with the portability of a laptop. GE Healthcare’s compact system is designed for general imaging, musculoskeletal, anesthesiology, interventional, emergency, and critical care applications.It provides ultrasound imaging with precise anatomical detail at a variety of depths. The system includes innovative features that help simplify interventional procedures.LOGIQ e Needle Recognition Software Option which helps provide precise and accurate display of the needle, anatomy and motion even in Color and Power Doppler. This feature harnesses pattern recognition technology that recognizes and accurately reveals the structure of a needle within the anatomy, without distortion of the needle and compromising the target.Also includes the ability to adjust needle gain and angle.
  • Standard package includes AC power cord (USA)
  • internet cord 3 meter in length CAT-5 type
  • PC to HUB structure
  • system software on USB
  • Optional Function Key Label
  • Ultrasound Transmission Gel .25L
  • English Basic Service Manual CD and English User Guide and AIUM booklet.
The following scanning modes are included:
  • B-mode
  • M-mode
  • Anatomical M-mode
  • Color flow mode
  • Power Doppler imaging
  • Pulsed wave Doppler and Ophthalmic
Features:The NextGen LOGIQ ecombines the high performance of a console system with the portability of a laptop. GE Healthcare’s compact system is designed for general imaging, musculoskeletal, anesthesiology, interventional, emergency, and critical care applications.Display Screen:
  • 15 in High-Resolution Color LCD
  • Resolution: 1024 x 768
  • Horizontal/Vertical viewing angle: +/-80 degree
  • Brightness AdjustmentIntegrated Speakers
  • Audio Volume Adjustment
  • Interactive Dynamic Software Menu
Console Design:
  • Laptop Style
  • Lithium Ion Battery
  • Integrated Solid State Drive
  • CPU – Intel Duo Core
  • Operating System – Microsoft® Windows® 7
Console Interfaces:
  • DC Power Input
  • USB 2.0 (3)
  • LAN 10/100/1000 BaseT
  • Docking Cart Connector
  • HDMI
Standard Features:
  • Integrated Solid State Drive
  • Automatic Optimization
  • CrossXBeamTM
  • Speckle Reduction Imaging (SRI-HD)
  • Virtual Convex/Virtual Apex
  • Fine Angle Steer
  • HD Zoom (Write Zoom)
  • Coded Harmonic Imaging (CHI)
  • Raw Data Processing
  • Quicksave
  • On-board User Manual (Help)
  • InSiteTM ExC capability
  • Loop storage—from live scanning and from memory
  • Patient Information Database
  • Customizable User Interface
  • Full M&A Calculation Package with Real Time Auto Doppler Calculations
  • Vascular Calcs
  • Cardiac Calcs
  • OB Calcs and Tables
  • Fetal Trending
  • Multi Gestational Calcs
  • Musculoskeletal and Hip Dysplasia Calcs
  • Gynecological Calcs
  • Urological Calcs
  • Renal Calcs
  • Small Parts Calcs
  • Rheumatology Calcs
  • Pediatric Calcs
  • Report Writer Package
 Software Options:
  • easy3D
  • LOGIQ View
  • Needle Recognition
  • Stress Echo
  • eSmart Trainer
  • Auto IMT
  • DICOM® 3.0 Connectivity/Encrypted DICOM
Specifications: Console Dimensions Height
  • 70 mm (2.75 in) console only
  • 100 mm (3.94 in) with handle
Width
  • 295 mm (11.61 in) console only
  • 343 mm (13.50 in) with handle
Length
  • 346 mm (13.62 in) console only
  • 375mm (14.76 in) with handle
Weight with Battery: Approximately 5.2 Kg (11.5 lbs)Operator Keyboard
  • Alphanumeric Keyboard
  • Ergonomic Hard Keys
  • Backlight Keys
Display Screen
  • 15 in High-Resolution Color LCD
  • Resolution: 1024 x 768
  • Horizontal/Vertical viewing angle: +/-80 degree
  • Brightness Adjustment
  • Integrated Speakers
  • Audio Volume Adjustment
  • Interactive Dynamic Software Menu
Console Electrical Power
  • Voltage: 100-240 V AC
  • Frequency: 50/60 Hz
  • Power: Max. 130 VA
Applications:GE Logiq E R7 Portable Ultrasound Machine
  • Abdomen
  • Cardiac
  • Gynecology
  • Musculoskeletal
  • Obstetrical
  • Nerve Block
  • Pediatric
  • Small Parts
  • Urological
  • Vascular
  • Rheumatology
  • Emergency Medicine
  • Cardiac intra-operative
Deka Synchro Replay Laser Nd-Yag

Inside Moveo Innovation

Moveo HR: Focus on Hair Removal The multiple passes of Moveo HR over small defined areas cause gradual heating and destruction of unwanted hairs.

Moveo PL: Focus on Pigmented Lesions The new MOVEO PL is indicated for skin age and sun spots progressively heating the pigmentedMoveo SR: Focus on Skin Rejuvenation The multipass controlled action of MOVEO SR causes a progressive increase in heat at the dermal level, which stimulates a neocollagenic process.Moveo VL: Focus on Vascular Lesions The specific action of Moveo VL acts directly and effectively on vascular redness.The versatile FT lamp can be added to the system at any time, enhancing the user’s ability to treat superficial Vascular and Pigmented Lesions.The FT pulsed light has ten different filters divided in five spectra of emission (500-520-550-600-650nm) and two spot areas. This flexibility is useful to adapt the emitted light to the patient skin type, application and treatment area.

Deka Synchro Replay Laser Nd-Yag Standard Handpieces

– More than 10 selectable handpieces

– Different spotsizes available (2.5 – 24 mm)– Automatic spot recognition system– Ergonomic connector for air-cooling devicesDeka Synchro Replay Laser Nd-Yag Wavelength: 1064 nm Pulse Energy: 120 J (max) Pulse Lenght: 0.2 ms to 300 ms Frequency Single Pulse: 10Hz (max) Spot Diameter: 20mm, 15mm, 10mm, 7mm, 5mm, 2.5mm Emission Spectrum: 500-950 nm and 650-950 nmTo Include: 1 x Foot Switch 1 x Key 1 x Module UPL Handpiece 6 x Deka Laser Handpieces 1 x ManualInside Moveo Innovation

Moveo HR: Focus on Hair Removal The multiple passes of Moveo HR over small defined areas cause gradual heating and destruction of unwanted hairs.

Moveo PL: Focus on Pigmented Lesions The new MOVEO PL is indicated for skin age and sun spots progressively heating the pigmented lesions.Moveo SR: Focus on Skin Rejuvenation The multipass controlled action of MOVEO SR causes a progressive increase in heat at the dermal level, which stimulates a neocollagenic process.Moveo VL: Focus on Vascular Lesions The specific action of Moveo VL acts directly and effectively on vascular redness.

2019 Lumenis Splendor X- Laser Hair Removal

Lumenis Splendor X Laser Hair RemovalThe Alexandrite wavelength at 755 nm, which is ideal for treating skin tones 1, 2 and 3 (fair and light skin tones). It is highly absorbed in melanin and is therefore not safe for use on darker skin tones. The Nd:YAG wavelength at 1064 nm, which is ideal for treating skin tones 4, 5 and 6 (4 being tanned skin and 5 and 6 darker skin tones) as the absorption by melanin is much lower than with the Alexandrite wavelengthThe Lumenis Splendor X has been introduced to be a player in the solid state Nd:YAG and Alexandrite laser hair removal market. The gold standard for hair removal has always been considered Alexandrite 755nm for light skins and Nd:YAG 1064nm for dark skins.The Lumenis Splendor X combines both in a unique way with blended emission.Instead of firing a single wavelength at a time the Splendor X allows you to fire both wavelengths simultaneous in adjustable amounts to suit the skin type and hair types. This means you are target multiple chromophores at any given time given enhanced results across the board.The Lumenis Splendor X also allows the user to choose between square and round spot sizes with large spot sizesLumenis Splendor X Laser Hair RemovalThe Alexandrite wavelength at 755 nm, which is ideal for treating skin tones 1, 2 and 3 (fair and light skin tones). It is highly absorbed in melanin and is therefore not safe for use on darker skin tones. The Nd:YAG wavelength at 1064 nm, which is ideal for treating skin tones 4, 5 and 6 (4 being tanned skin and 5 and 6 darker skin tones) as the absorption by melanin is much lower than with the Alexandrite wavelength
Laser Hair Removal
Details:2019 Lumenis Splendor X- Laser Hair Removal
  • Serial Number: SQEAY-19M-XXXXX (message for serial number)
  • System Total Shot Count: 560,693
  • Alex Shot Count: 221,437
  • YAG Shot Count: 339,256
Includes:
  • Handpiece and Delivery System
  • Square Spot Sizes: 2x2mm, 3x3mm, 5x5mm, 10x10mm, 14x14mm, 18x18mm, 20x20mm, 24x24, 27x27mm
  • Fiber Pole
  • Foot Switch
  • System Key
  • Operators Manual
  • 30 Day Parts and Labor Warranty
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
You're viewing: Cutera Excel HR 1064 755 Hair Removal System For Sale $9,800.00
Add to cart
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
  • Attributes
  • Custom attributes
  • Custom fields
Click outside to hide the comparison bar