| Description | PicoWay laser became famous for pigment removal capabilities and its tattoo, but it is growing in usage for acne scars and wrinkles. Picoway Laser is a Really strong Pico laser device that treats pigmentation, skin irregularities and also the signs of aging | ADVANCED TECHNOLOGY2019 Venus Concept Neo Graft 2.0 system is the industry pioneer and market leader with one of the first automated FUE system in the hair restoration market. NeoGraftharvesting, site-making and implantation functions make it easier than ever for physicians to address hair loss and provide the hair restoration procedures that patients want. The inefficiencies of manual extractions and implants have been eliminated, and replaced it with advanced technology that provides patients with the benefits of the FUE procedure while also enabling physicians to perform fast, effective, safe hair transplants that yield superior clinical results. | 2008 Lutronic Spectra VRM III Tattoo Laser, Q-switched Nd Yag, 532, 1064, 585 and 650 nm Wavelengths. Excellent Operating Condition operating at full power. Manufactured: 2008, Received Inspection and Preventive Maintenance February 2016. Includes Footswitch, 1 Pair Operator Eyewear, 532/1064 Handpiece, 585 and 650 Dye Handpieces. | The PURE+ is offered in two configurations:FSR + TC: Fixed FSR handpiece + one exchangeable connector suitable for all TC handpieces: iFine, Small and Large
TC Complete: Two exchangeable connectors on each side, suitable for all TC handpieces: iFine, Shaper, Small and LargeThe iFine treatment Handpiece –
specially engineered to target fine lines and wrinkles found in the delicate thin skin areas around the eyes, providing:
Smoother, tighter skin around the eyes.
Reduced under eye sagging and improved eye contour.
Reduced hooding to reveal more of the eyelid.
More youthful, less tired looking eyes.
Softening of fine line enabling easier application of make-up. | Candela GentleMAX ProEstablished in 1970, Candela is a leading US-based global medical aesthetic device company with headquarters in Wayland, Massachusetts. The company’s technologies enable physicians to provide advanced energy-based solutions for a broad range of medical-aesthetic applications including benign vascular and pigmented lesions, scars, hair removal, facial resurfacing, wrinkle reduction, women’s health treatments, tattoo removal, acne, leg veins, cellulite, and body shaping. | New Handpiece Design The Optima – 518 Classic is the first model to use the new Mark II which enables a multipurpose handpiece:
* Faster treatments – up to 0.5 Seconds Between pulses.
* Real-time handpiece temperature control.
* Contemporary and stylish design.
* Light weight design – 25% less weight to improve the therapists’ comfort. |
| Content | Candela PicoWay Laser Tattoo Removal
Candela Picoway resolveThe new approach to building new collagen and elastin in the treatments acne scars and wrinkles.In brief, 15- to 20-minute treatment sessions, the PicoWay Resolve system transforms skin while leaving the epidermis intact. So patients can get back to their lives quickly, without significant side effects.
Minimise risk in patients with darker skin shades.The candela PicoWay system’s ultra-short picosecond pulses are 100 times shorter than Q-switch lasers. in the trillionths of a second. Picosecond pulses will minimise the risk of side effects and thermal damage.Side effects such as hyperpigmentation and scarring can be a thing of the past with Candela Picoway laser.
Candela PicowayThe complete picosecond laserThe PicoWay system features three wavelengths (1064nm, 785nm, and 532nm) and multiple handpieces to maximise your treatment options — and your ROI.
The Candela Picoway laser delivers high peak powers with the shortest pulse duration
This picosecond technology ensure a non-thermal, photoacoustic effect to transform the skin from the inside out.
The Candela Picoway laser can:Improve and remove scarring and wrinkles
Address a wide range of beingh pigments
Treat a wide range of tattoos including difficult colours such as greenkey benefits of Candela picowayWith the Candela picoway you have the opportunity to achieve fantastic results for your patients and for your business.
4 reasons your patients will love itclinically proven to deliverReduce Acne scarring after just 3 treatment
Improvement of wrinkles and severity
high rate pigmented clearance
emove of multi-coloured tattoosPhotoacoustic effect.Candela PicoWay Laser Tattoo RemovalUltra-short pulses enable the strong photoacoustic impact needed to effectively fracture pigment particles without overheating surrounding skin tissues.
SystemThe Candela PicoWay flexible treatment parameters put you in control of
wavelength,
fluence,
repetition rate
spot size
for highly customizable treatments.
Plus, with the shortest picosecond pulses, the PicoWay system’s skin treatment pallet extends from the lightest to even the darkest skin types
Three true picosecond wavelengths for optimal treatment customization.
PicoWay system: 1064nm, 785nm, 532nm | 2019 Venus Concept Neo Graft 2.0
is a revolutionary automated Follicular Unit Extraction (FUE) and implantation technology that leaves no linear scar and is minimally invasive with fast patient recovery. It eliminates the inefficiencies of common manual tools and procedures while enabling physicians to offer hair transplants with consistent clinical outcomesADVANCED TECHNOLOGY2019 Venus Concept Neo Graft 2.0 system is the industry pioneer and market leader with one of the first automated FUE system in the hair restoration market. NeoGraftharvesting, site-making and implantation functions make it easier than ever for physicians to address hair loss and provide the hair restoration procedures that patients want. The inefficiencies of manual extractions and implants have been eliminated, and replaced it with advanced technology that provides patients with the benefits of the FUE procedure while also enabling physicians to perform fast, effective, safe hair transplants that yield superior clinical results.
OPTIMIZED WORK FLOW- Double-jointed arm and enhanced ergonomics ensure faster and more comfortable procedures for both patients and physicians Used Venus Concept Neograft 2.0 for sale
- New contra angle eliminates loss of fluid and protects grafts through vacuum seal
- Recipient site creation handpiece delivers more standardized implants
- No-touch implanter offers the least amount of bulb trauma
- Autoclavable handpieces offer sterilizable and cost-effective tools
PNEUMATIC MOTOR AND SMART DRIVE TORQUE TECHNOLOGY- Piston-driven motor delivers precise pressure control for both extraction and implantation
- Smart Drive Torque Technology delivers 100% torque to the contra angle/punch, for continuous rotation and the smoothest entry.
- Consistent suction and spin lead to standardized extractions, high quality grafts, and superior patient outcomes
INTUITIVE TOUCHSCREEN INTERFACE WITH GRAPHICAL USER INTERFACE (GUI)- Automatic, real-time extraction and implantation of graft counts eliminates manual counting and paperwork
- GUI delivers user friendly, intuitive, interactive experience
- Treatment screens allow users to easily switch between two modes – extraction and implantation
- User management tools help track and improve performance of treatment providers
OPERATIONAL EFFICIENCY WITH INTERNET OF THINGS (IOT) TECHNOLOGY AND DEVICE MOBILITY- Advanced IoT technology capabilities enhance business operations by optimizing treatment protocols, improving patient results & satisfaction, and maximizing operational efficiency & ROI
- Quiet operation and energy-efficient usage
- Device occupies less than 5 sq. ft. and weighs 36 Kg with storable pedals and 360-degree turning
| Lutronic Spectra VRM III Tattoo LaserLaser Source:Nd:YAG
Wavelengths:532 nm, 1064 nm, 585 nm and 650 nm (dye handpieces)
Operating Mode:5-7 nanoseconds
Pulse Duration:Spectra mode = 300 microseconds
Maximum Energy:Q-switched mode = 1,000 mJ, Spectra mode = 1,500 mJ
Beam Profile:Top Hat (Uniform) Mode
Optical Delivery:Articulated arm
Aiming Beam:Diode 655 nm (Red) 1 mW, adjustable brightness The Lutronic Spectra VRM is an award-winning laser system designed for use in a wide range of dermatological and aesthetic procedures. This powerful Q-switched Nd:YAG system is clinically effective for a variety of benign pigmented lesions, tattoos and more. Offering two distinct wavelengths at 1064nm and 532nm, the Spectra VRM (with optional solid dye handpieces) reliably removes even colored amateur, professional and traumatic tattoos with precision and ease. With the optional solid dye hand pieces, the VRM series can double its capacity in treating an assortment of tattoo inks.A special feature of the VRM Series is the addition of the Lutronic “ Spectra Mode” that extends the range of procedures that can be performed to include laser peeling, skin rejuvenation, wrinkle removal and melasma treatments.In combination of Spectra Mode and a carbon-based lotion, this soft laser peel feature is specifically designed to emit a quasi-long pulse of 300 microseconds to create photothermal energy to heat the skin’s thin layer of collagen and fibroblast, resulting in a younger and healthier looking. Together with consistent shot-to-shot stability, the VRM is a true workhorse for cosmetic treatments such as photo rejuvenation, non-ablative resurfacing, fine wrinkles, acne scars, and pore size reduction. Key Benefits Lutronic Spectra VRM III Tattoo Laser- Auto-Detected Ergonomic Zoom Handpiece 3-8mm
- Shortest true nanosecond pulse width (5ns) for improved efficacy with less downtime
- 1064/532nm dual-wavelengths for enhanced Tx versatility (optional 585/650nm Dye HPs)
- Exclusive Spectra mode (300us) enables the patented Hollywood Laser Peel®
- 1st short pulse laser to earn FDA clearance for treating melasma
Other item to considerCandela GentleLase Pro ALEXANDRITE LASER 3 Clinically-backed Facts:- Used around the world to reduce/remove unwanted skin pigmentation.
- Over 50 clinical articles have been published using the Spectra platform
- Its high quality design and beam profile enables safe treatment of complex dermal pigment (e.g.: Nevus of Ota) in darker skin type patients, with minimal risk of side effects.
| ENDYMED PURE PLUS Input Power:100-120V, 50-60Hz, 2A or 220-240V, 50-60Hz, 1A
Power Consumption:220 W
Fuses:2 x 1.6A for 220V; 2 x 3.15A for 110V
Output Power:Up to 50 Watts
Output Frequency:1MHz
Working Temperature:+10°C – +25°C
Dimensions:(H x W x D) 600 x 305 x 365 mm
Weight:10 kg
GOOD THINGS COMES IN SMALL PACKAGES THE PURE+
The Pure+ by Endymed Pure Plus, powered by our FDA cleared, patented 3DEEPRF technology. The PURE+ offers professional grade Fractional Skin Resurfacing and superior body, facial and neck tightening and contouring treatments, all on one easy to use, compact platform. The PURE+ offers complete flexibility with exchangeable treatment handpieces one PURE+ console can be configured any way you like to provide you and your clients with the most effective and popular treatments available today.The PURE+ is offered in two configurations:FSR + TC: Fixed FSR handpiece + one exchangeable connector suitable for all TC handpieces: iFine, Small and Large
TC Complete: Two exchangeable connectors on each side, suitable for all TC handpieces: iFine, Shaper, Small and LargeThe iFine treatment Handpiece –
specially engineered to target fine lines and wrinkles found in the delicate thin skin areas around the eyes, providing:
Smoother, tighter skin around the eyes.
Reduced under eye sagging and improved eye contour.
Reduced hooding to reveal more of the eyelid.
More youthful, less tired looking eyes.
Softening of fine line enabling easier application of make-up.3Deep Small-Medium Handpiece
Designed to treat wrinkles and lax skin on the face, neck and upper body.3Deep Fractional Skin Resurfacing Handpiece
Specially designed for fractional skin resurfacing and treatment of skin roughness, hyperpigmentation, and wrinkles and scars on both facial and body. The FSR handpiece contains a matrix of 112 tiny electrodes, allowing for the first time simultaneous fractional micro-ablation of the epidermis, together with volumetric heating of 100% of the dermis. This technology provides the capability to differentiate between micro-ablation and dermal heating which appears to be the optimal multi-layer treatment to affect aging skin and atrophic acne scars.3Deep Shaper Handpiece
Major innovation in RF skin tightening, body shaping and contouring, and cellulite treatment for large body areas. The handpieces unique engineered electrode surface is 40.7 cm2 allowing for shorter treatment times (20 minute abdomen treatment, 30 minute cellulite treatments for the thighs and buttocks). Deeper, controlled energy penetration tightens and firms the skin by stimulating the bodys natural collagen renewal process, providing better and more effective results. | 2017 Candela GentleMAX Pro Device DetailsThe Candela GentleMax Pro yields high energy, subjecting patients to fewer laser pulses providing faster treatment times with the 24mm spot size, the largest spot found on any hair removal laser. Candela’spatented Dynamic Cooling Devise (DCD) technology protects the upper layers of skin with cooling bursts of cryogen. DCD cooling offers optimal treatment with minimal side effects.| Distributor | Candela |
|---|
| Manufacturer | Candela |
|---|
| Model | GentleMAX Pro |
|---|
| Manufactured Year | 2017 |
|---|
| Specific Equipment Type | Dual Wavelength Laser |
|---|
| Sale Price | 12500 |
|---|
| Treatments Performed | Hair Removal, Vascular, Pigmentation
Skin Rejuvenation
Skin Tightening |
|---|
| Handpieces | Standard Handpiece DCD 12-18mm , Large Spot Size Handpiece DCD 22-24mm |
|---|
| Shot Counts | None |
|---|
| Wavelengths | 755nm
1064nm |
|---|
| Consumables used by device | Windows, Distance Gauges |
|---|
| Consumables with purchase | 3 x Operator goggles, 1 x patient goggles, distance gauges, windows |
|---|
| Annual Service Price | Servicing available through Candela |
|---|
| Service Contract Price | $11,000 per annum |
|---|
| Additional Information | Any additional information can be sent on request |
|---|
| |
|---|
Treatments:2017 Candela GentleMAX Pro Device Details- Hair Removal
- Beard Bumps
- Facial Lesions
- Fine Lines and Wrinkles
- Leg Veins
- Skin Tightening
- Vascular Lesions
- Warts
- Skin Rejuvenation
- Hemangiomas
- Birthmarks
- Freckles
- Melasma
- Mevus of Ota
- Pigmented Lesions
- Sun / Age Spots
The Candela GentleMax Pro yields high energy, subjecting patients to fewer laser pulses providing faster treatment times with the 24 mm spot size, the largest spot found on any hair removal laser.Fast – With 24 mm spot size and repetition rates up to 2 Hz, the The Candela GentleMax Pro yields high energy, subjecting patients to fewer laser pulses providing faster treatment times with the 24 mm spot size, the largest spot found on any hair removal laser. It has two wavelengths, the 755 Alexandrite and the 1064 ND:yag, allowing you to offer many treatment options.Candela’s patented Dynamic Cooling Devise (DCD) technology protects the upper layers of skin with cooling bursts of cryogen. DCD cooling offers optimal treatment with minimal side effects. offers fast treatment times with it’s spot size.Powerful – 26,333 watts peak power, capable of delivering fluences up to 100 J/cm² for vascular applications, and hair removal energy in pulse duration as short as 3 ms for unparalleled treatment efficacies.Treats all skin types – Deep penetration with minimal scattering of laser energy makes the GentleMax Pro ideal for all skin types, particularly dark and tanned skin.Versatile – Non-ablative treatment, including fine lines and wrinkles, and for pseudofolliculitis barbae (PFB), or beard bumps, leg and facial veins.Patented Epidermal Cooling – Candela’s Dynamic Cooling Device represents an adjustable epidermal protection technology to maximize patient safety and comfort.Date of Manufacture – 2017Accessories Included with Purchase – Specialty 1.5, 3mm, 3x10mm Handpiece, 6, 8, 10, 12, 15, 18mm Handpiece, Full Set of Distance Gauges, Distance Gauge Case, Patient Eyewear, Treatment Goggles, Foot Pedal, Fiber Pole, System Key, System Interlock Key, Treatment Guidelines, and User Manual. | Active Optical Systems Optima 518 IPL LaserHandpiece (Standard):Multipurpose Wavelength Mark-II
Handpiece (Optional):Facial Treatments
Pulse Interval/Repetition Rate:0.5 – 2 Seconds
Maximum Output Treatment Pattern:22 Joule /cm 2
Output Power:11-31 Joule / cm 2 , up to 4000 W
Cooling System:Improved Air Cooling
Control:Advanced Software Interface
Lamp’s Life Span:200,000 Flashes (minimum)
Treatment Area/Spot Size:15 x 50 mm, (7.5 cm 2)
Wavelength:420 – 1,100 nm
Weight:88.18 lbs (40Kg) (including stand)
Dimensions:17.32 inches x 17.72 inches x 39.37 inches (44cm x 45cm x 100cm)
Mains:220-230 VAC, 50/60 Hz; 100-120 VAC, 50/60 Hz
Max Mains Power:600 VA
Treatments Variety:
Skin Rejuvenation
Pigmentation Treatment
Acne Treatment
Hair Removal
Hair Removal – Deep Follicles
Hair Removal – Sensitive Skin
Vascular (Facial) Treatment
Tattoo Removal
The Laser uses 12 preset programs. The programs are set in a consecutive, energy intensity increasing order, as specified by the tables of settings, covering all types of hair and skin combinations to be treated.
12 Programs
1 – Very Dark Skin, Fitzpatrick Skin Type IV
2 – Dark Skin, Fitzpatrick Skin Type IV
3 – Dark Skin, Fitzpatrick Skin Type III
4 – Dark Skin, Fitzpatrick Skin Type III
5 – Medium Skin, Fitzpatrick Skin Type II
6 – Medium Skin, Fitzpatrick Skin Type II
7 – Light Skin, Fitzpatrick Skin Type II
8 – Light Skin, Fitzpatrick Skin Type I
9 – Very Light Skin, Fitzpatrick Skin Type I
10 – Very Light Skin, Fitzpatrick Skin Type I
11 – Very Light Skin, Fitzpatrick Skin Type I
12 – High Power, Fitzpatrick Skin Type IOptima-518-Classic Active Optical Systems Optima 518 IPL LaserThe Optima – 518 Classic was designed to answer the needs of sophisticated practitioners who want to provide state of the art treatment to their patients on one hand, based on proven and tested treatment protocols and on the other hand to have the ability to reach new and improved protocols by conducting innovative clinical investigations.The Optima – 518 Classic, based on active’s GEM-PL technology, sets the pulse pattern according to the selected treatment type, skin color, skin photosensitivity and treatment depth. The treatment protocols and different pulse patterns take into account the tissue’s TRT (Thermal Relaxation Time) and the combined knowledge accumulated from thousands of treatments done during the years and clinical investigations done to confirm the findings.New Handpiece Design The Optima – 518 Classic is the first model to use the new Mark II which enables a multipurpose handpiece:
* Faster treatments – up to 0.5 Seconds Between pulses.
* Real-time handpiece temperature control.
* Contemporary and stylish design.
* Light weight design – 25% less weight to improve the therapists’ comfort.Research program for clinical investigations, the self setting program allows researchers to set the treatment’s parameters according to their needs. Allowing advanced research with the device. The energy levels in the self setting program can reach 31J cm 2 with high intensity of 4000 W.Approvals
* CE MDD Intl. Medical Standard
* FDA U.S. Safety Standard
* ISO-13485 Med. Production STD
* IEC 60-601-1 Medical Safety STD
* CFS Gov. Health Approval
* CSA Can. & U.S. Safety App
* TGA Australian health STD. |
Reviews
There are no reviews yet.