| Description | The Aesthetika FRAKTA SuperPulse 40-Watt CO2 Laser is a 40-watt carbon dioxide-based medical and aesthetic device that utilizes SuperPulse technology for high-precision skin resurfacing, scar removal, and skin rejuvenation with minimal thermal damage to surrounding tissue. | Includes:
iFine Handpiece
Small-Medium Handpiece
Two Exchangable Connectors on each side suitable for all handpieces
2 Keys
Infared Handheld Sensor
Operators Manual | 2017 Lumenis M22 with ResurFX & IPL in Like-New Condition; Manufactured 10/22/2017; Based Unit Serial Number 11860, IPL Handpiece Serial Number: 4751; Nd Yag Serial Number: Perfect Cosmetic and Operating Condition, Single Owner; Handpieces Included & Total Pulse Counts: IPL Handpiece Total Pulse Count = 908; ResurFX Handpiece Pulse Count = 16 Pulses; Includes Expert Filters: 515nm, 560nm, 590nm, 615nm, 640nm, 695nm, and 755nm; Also Includes: Footswitch, Interlock, Operator Manual. | Includes:
1 Fractional Scanner Handpiece for Ablative Skin Resurfacing
1 Incisional Handpiece with up to or less than .2mm Spot Size
Handpiece Case
Distance Gauges
Footswitch
Patient Eyewear
Operator Eyewear
Operator Manual
Warning Sign | - Muscoskeletal Disorders
- Degenerative arthritis
- Rheumatoid arthritis
- Cervical pain
- Sport injuries
- Frozen shoulder
- Muscle relaxation
- Pain management
| Laser Hair Removal
Details:- Serial Number: SQEAY-19M-XXXXX (message for serial number)
- System Total Shot Count: 560,693
- Alex Shot Count: 221,437
- YAG Shot Count: 339,256
Includes:- Handpiece and Delivery System
- Square Spot Sizes: 2x2mm, 3x3mm, 5x5mm, 10x10mm, 14x14mm, 18x18mm, 20x20mm, 24x24, 27x27mm
- Fiber Pole
- Foot Switch
- System Key
- Operators Manual
- 30 Day Parts and Labor Warranty
|
| Content | Aesthetika FRAKTA SuperPulse 40 Watt CO2 LaserUnparalleled Precision & Power
The FRAKTA SuperPulse 40W CO2 Laser, FDA Cleared for Laser Skin Resurfacing (K242941), is a cutting-edge fractional laser system designed for superior skin resurfacing, rejuvenation, and gynecological applications. With its high-energy output and SuperUltra pulse technology, this system enhances collagen stimulation, wrinkle reduction, and tissue tightening with minimal downtime.Key Benefits for Physicians & Patients- Advanced Super Pulse Technology – Deep skin penetration with controlled ablation for superior skin tightening and scar treatment.
- Fast Scanning System – Ensures rapid treatment times, increasing efficiency for clinics.
- Non-Ablative MIX Mode – Offers both ablative and non-ablative capabilities in a single system, reducing patient discomfort and downtime.
- Versatile Treatment Modes – Ideal for dermatology, aesthetic medicine, and gynecological rejuvenation.
- Metal RF Tube Technology – Provides long-lasting durability (7-10 years) and maintenance-free operation.
- Adjustable Scan Shapes & Sizes – Tailor treatments to different patient needs with 7 distinct scanning patterns.
- Enhanced Air Cooling System – No need for additional cooling devices, making procedures more comfortable for patients.
Comparison: FRAKTA SuperPulse vs. Top CO2 Lasers| Feature | FRAKTA SuperPulse 40W CO2 Laser | Other Leading CO2 Lasers | | Laser Power | 1-40W adjustable | 30-40W | | Pulse Technology | SuperUltra Pulse for deep penetration | Standard pulse | | Modes | Fractional, Surgical, Gynecological, MIX | Fractional, Surgical | | Cooling System | Air cooling, maintenance-free | Water cooling, requires maintenance | | Scan Shapes | 7 adjustable patterns | 4-5 patterns | | Gynecological Applications | Yes, specialized handpieces | Limited | | Durability | 7-10 years (Metal RF Tube) | 3-5 years (Glass Tube) |
Applications & Treatment Capabilities- Skin Rejuvenation & Resurfacing – Targets fine lines, wrinkles, and sun damage.
- Scar Revision – Effectively treats acne scars, surgical scars, and stretch marks.
- Pigmentation Correction – Reduces dyschromia and age spots.
- Fractional Gynecological Treatments – Vaginal rejuvenation, stress urinary incontinence, and labia tightening.
- Surgical Applications – Precision cutting with minimal bleeding.
Technical Specifications- Laser Type: Fractional CO2 (10.6μm)
- Power Output: 1-40W (adjustable)
- Spot Size: ≤0.1mm for precise treatments
- Cooling System: Air cooling, built-in air blow
- Indication Beam: Red Diode Laser (650nm)
- Transmission: 7-Articulation Joint Spring Arm
- Power Supply: 220V±22V, 50Hz±1Hz
- Weight: 55kg
Why Choose FRAKTA SuperPulse CO2?
Faster Treatments – Higher power and optimized scanning patterns reduce procedure time.
Greater Versatility – Works for aesthetic, medical, and gynecological treatments.
Longer Lifespan – Metal RF Tube technology ensures 7-10 years of usage with no maintenance.
Patient Comfort – SuperUltra Pulse provides deep penetration with minimal thermal damage, ensuring a comfortable experience.
Cost-Effective – No water cooling means lower maintenance costs and higher ROI for clinics.Transform Your Practice with the FRAKTA SuperPulse 40W CO2 Laser
Experience the next generation of precision, power, and versatility in fractional laser technology. Contact us today to learn more! | ENDYMED PURE PLUS LASER
GOOD THINGS COMES IN SMALL PACKAGES THE PURE+
The Pure+ by Endymed Pure Plus, powered by our FDA cleared, patented 3DEEPRF technology. The PURE+ offers professional grade Fractional Skin Resurfacing and superior body, facial and neck tightening and contouring treatments, all on one easy to use, compact platform.The PURE+ offers complete flexibility with exchangeable treatment handpieces one PURE+ console can be configured any way you like to provide you and your clients with the most effective and popular treatments available today.The PURE+ is offered in two configurations:FSR + TC: Fixed FSR handpiece + one exchangeable connector suitable for all TC handpieces: iFine, Small and Large
TC Complete: Two exchangeable connectors on each side, suitable for all TC handpieces: iFine, Shaper, Small and LargeEndymed Pure Plus LaserIncludes:
iFine Handpiece
Small-Medium Handpiece
Two Exchangable Connectors on each side suitable for all handpieces
2 Keys
Infared Handheld Sensor
Operators ManualInput Power:100-120V, 50-60Hz, 2A or 220-240V, 50-60Hz, 1A
Power Consumption:220 W
Fuses:2 x 1.6A for 220V; 2 x 3.15A for 110V
Output Power:Up to 50 Watts
Output Frequency:1MHz
Working Temperature:+10°C – +25°C
Dimensions:(H x W x D) 600 x 305 x 365 mm
Weight:10 kgThe iFine treatment Handpiece –
specially engineered to target fine lines and wrinkles found in the delicate thin skin areas around the eyes, providing:
Smoother, tighter skin around the eyes.
Reduced under eye sagging and improved eye contour.
Reduced hooding to reveal more of the eyelid.
More youthful, less tired looking eyes.
Softening of fine line enabling easier application of make-up.3Deep Small-Medium Handpiece
Designed to treat wrinkles and lax skin on the face, neck and upper body.3Deep Fractional Skin Resurfacing Handpiece
Specially designed for fractional skin resurfacing and treatment of skin roughness, hyperpigmentation, and wrinkles and scars on both facial and body. The FSR handpiece contains a matrix of 112 tiny electrodes, allowing for the first time simultaneous fractional micro-ablation of the epidermis, together with volumetric heating of 100% of the dermis. This technology provides the capability to differentiate between micro-ablation and dermal heating which appears to be the optimal multi-layer treatment to affect aging skin and atrophic acne scars.3Deep Shaper Handpiece
Major innovation in RF skin tightening, body shaping and contouring, and cellulite treatment for large body areas. The handpieces unique engineered electrode surface is 40.7 cm2 allowing for shorter treatment times (20 minute abdomen treatment, 30 minute cellulite treatments for the thighs and buttocks). Deeper, controlled energy penetration tightens and firms the skin by stimulating the bodys natural collagen renewal process, providing better and more effective results. | 2017 Lumenis M22 IPL with ResurFX| Manufacturer Notes |
|---|
| M22 is a modular multi-application platform for the treatment of over 30 skin conditions and hair removal.Available Treatments with M22:– Acne Scar Treatment
– Hair Removal
– Non-Ablative Skin Resurfacing
– Photorejuvenation
– Pigmentation Treatment
– Scar Revision
– Vascular / Leg Vein Treatment
– Dark Tattoo RemovalUsed by physicians around the world, M22 enables you to treat more types of patients and conditions with better outcomes.4 Multiple Technologies In One Modular SystemM22 grows with your practice and can expand to your treatment needs and adapts to future applications as they emerge.Universal IPL
Optimal Pulse Technology (OPT)
Single handpiece with changeable filters and lightguides
For IPL skin treatments using photorejuvenationResurFX
The only True fractional non-ablative, with CoolScan scanner
No disposables
For skin resurfacingMulti-Spot Nd:YAG
The only one with Multiple Sequential Pulsing (MSP)
2 sized lightguides, changeable in seconds
For treatment of leg veins and vascular lesionsQ-Switched Nd:YAG
Homogenous beam profile for enhanced treatment safety and efficacy
For skin toning*, dark tattoos removal, and combination treatments
*Skin toning by treatment of pigmented lesions |
2017 Lumenis M22 IPL with ResurFX and Q-Switched Nd:YAG A modular multi-application system for hair removal and various skin conditions Details:M22 Serial Number: 21171 M22 Date of Manufacture: 2017-07-17 Total IPL Pulses: 19,186 Total ResurFX Pulses: 10,772 Q-Switched Nd:YAG Pulses: 385,505
Includes:IPL Handpiece Complete Standard IPL filters: 515, 560, 590, 615, 640, 695, 755nm, and Calibration Specialty IPL Filters: Acne and Vascular IPL Light Guides: (1)35 x 15 mm2; (1)15 x 8 mm2, (1) 6mm- round ResurFX Handpiece with SapphireCool Tip Q-Switched Nd:YAG Handpiece Foot Switch Power Cord 30 Days Parts and Labor Warranty
|
System specifications
Dimensions:[without ResurFX] 44 x 50.5 x 47 cm (17 x 20 x 18.5 inches)
Dimensions:[with ResurFX] 44 x 50.5 x 61.5 cm (17 X 20 X 24 inches)
Weight:[without ResurFX] 40 kg / 88 lbs
Weight:[with ResurFX] 55 kg / 121 lbs
Electrical requirements:100 240 VAC ±10%, 15A max., 50/60 Hz, single phase, dedicated line M22 is a modular multi-application platform for the treatment of over 30 skin conditions and hair removal. Available Treatments with M22:– Acne Scar Treatment
– Hair Removal
– Non-Ablative Skin Resurfacing
– Photorejuvenation
– Pigmentation Treatment
– Scar Revision
– Vascular / Leg Vein Treatment
– Dark Tattoo RemovalUsed by physicians around the world, M22 enables you to treat more types of patients and conditions with better outcomes.4 Multiple Technologies In One Modular SystemM22 grows with your practice and can expand to your treatment needs and adapts to future applications as they emerge. Universal IPL
Optimal Pulse Technology (OPT)
Single handpiece with changeable filters and lightguides
For IPL skin treatments using photorejuvenation ResurFX
The only True fractional non-ablative, with CoolScan scanner
No disposables
For skin resurfacing Multi-Spot Nd:YAG
The only one with Multiple Sequential Pulsing (MSP)
2 sized lightguides, changeable in seconds
For treatment of leg veins and vascular lesions | EMVERA CLARO2 CO2 LASER
Claro2 Medical Laser System
The Claro2 laser technology offers the most innovative approach to laser treatments today. It provides an acceptable and comfortable procedure under little or no anesthesia with minimum pain from evaporation of the skin layers, resulting in minimal social or work downtime. The laser delivers a series of microscopic, closely-spaced laser spots to the skin while simultaneously preserving the normal, healthy skin. The undamaged skin becomes a reservoir of tissue for fast heating and regeneration of the treated area by producing and providing new dermal collagen and eliminating epidermal pigmentation and irregularities to the skin tone. The Claro2 laser system is specially designed to improve skin texture and tone, and fight wrinkles, scars and pigmentations. Since the treatment procedures are customized to patients skin, operators are able to adjust laser settings to tailor treatments and achieve superior results.Claro2 Laser Features Provide:
Unparalleled char-free ablation, vaporization, excision, or incision of soft tissues
Reduced thermal damage to surrounding tissues
Rapid healing and minimal downtime
Stimulation of deeper collagen with high pulse energy
Large TFT LCD touch screen provides easy operation with the latest high speed microprocessor technology
Adjustable scanning patterns and sizes
Adjustable intensity of pilot beam
Adjustable pulse duration
Last treatment setting memorization
Automatic alarm system for operation and errors
No consumable costsIncludes:
1 Fractional Scanner Handpiece for Ablative Skin Resurfacing
1 Incisional Handpiece with up to or less than .2mm Spot Size
Handpiece Case
Distance Gauges
Footswitch
Patient Eyewear
Operator Eyewear
Operator Manual
Warning SignLaser Type:Sealed of Co2 Laser
Wavelength:10.6 um
Mode Structure:TEM00
Max Power:0-30W (adjustable)
Spot Size:Equal to or less than .2mm
Aiming Beam:630nm Red Laser (Adjustable Brightness)
Delivery System:Articulated Arm
Operation Modes:Continuous Wave, Single Pulse, Repetition Pulse, Super Pulse, Scanner
Pulse Width:Single Pulse (0.01-1s); Repetition Pulse (0.001-1s); Scanner (0.0001-0.01s)
Scan Size: Adjustable
Scan Pattern:Oval, Triangle, Rectangle, Line
Scan Array Density:Adjustable
Cooling System:Self-Contained, Closed Cycle
Power Supply:100-120V AC, 50/60Hz or 200-240V AC, 50/60Hz
Environment Temperature:10-40 Degrees Celsius
Relative Humidity:Below 80%
Dimensions:561mm x 500mm x 1443mm
Weight:42kgApplications Include:EMVERA CLARO2 CO2 LASERDermatology, Plastic Surgery and General Surgery procedures including but not limited to:
Laser skin resurfacing
Treatment of furrows and wrinkles
Removal of skin tags, actinic keratosis, acne scars, keloids, tattoos, telangiectasia, squamous and basel cell carcinoma, warts and uneven pigmentation
Treatment of cysts, abscesses, hemorrhoids and other soft tissue applications
Blepharoplasty
Site preparation for hair transplantsOtorhinolaryngology (ENT) procedures including but not limited to:
Treatment of leukoplakia of larynx, nasal obstruction, rhinophyma, verrucrea vulgares, choanal atresia, rhinophyma, LAUP and papillomatosis polypsGynecology:
Treatment of condyloma acuminate, cervical
intraepithelial neoplasia, leukoplakia and vulvar/
vaginal intraepithelial neoplasia, cervical dysplasia
Podiatry procedures including but not limited to:
Ablation, vaporization and excision of soft
tissue lesions such as ingrown nail, fungal nail,
porokcratoma, matrixectomy and verrucae vulgares | 2020 CRYOMED HYPERMAX TALENTPRO
Electro-Magnetic Stimulation Technology
hyperMAX utilises Electro-Magnetic Stimulation technology to induce supramaximal contractions for
the growth and development of muscles. The magnetic field changes quickly inducing electrical currents in the tissue where neuronal membranes are depolarised and motor units in the target muscles are controlled to cause concentric contractions.How does it work?
Electro-Magnetic Stimulation helps to rebuild and repair muscle tissue, resulting in stronger and firmer muscles.
The strong Electro-Magnetic stimulation, of up to 3 Tesla, works deep to the hypodermis, influencing
muscle fibres and cell membranes to optimise cellular metabolism, supplying more oxygen for better blood circulation.Dualsculpt with Applicators
hyperMAX utilises Electro-Magnetic Stimulation technology to induce supramaximal contractions for the growth and development of muscles. The magnetic field changes quickly inducing electrical currents in the tissue where neuronal membranes are depolarised
and motor units in the target muscles are controlled to cause concentric contractions.2020 Cryomed HyperMAX TalentproIndications:- Muscoskeletal Disorders
- Degenerative arthritis
- Rheumatoid arthritis
- Cervical pain
- Sport injuries
- Frozen shoulder
- Muscle relaxation
- Pain management
Spinal Disorders- Acute/chronic lumbago
- Sciatica
- Spinal bifida
- Spondylitis chronic back pain
- Spinal disc disease
- Intramuscular stimulation
- Trigger Point Injection
Electro-Magnetic Stimulation TechnologyhyperMAX utilises Electro-Magnetic Stimulation technology to induce supramaximal contractions for
the growth and development of muscles. The magnetic field changes quickly inducing electrical currents in the tissue where neuronal membranes are depolarised and motor units in the target muscles are controlled to cause concentric contractions.How does it work?Electro-Magnetic Stimulation helps to rebuild and repair muscle tissue, resulting in stronger and firmer muscles.
The strong Electro-Magnetic stimulation, of up to 3 Tesla, works deep to the hypodermis, influencing
muscle fibres and cell membranes to optimise cellular metabolism, supplying more oxygen for better blood circulation. | 2019 Lumenis Splendor X- Laser Hair Removal
Lumenis Splendor X Laser Hair RemovalThe Alexandrite wavelength at 755 nm, which is ideal for treating skin tones 1, 2 and 3 (fair and light skin tones). It is highly absorbed in melanin and is therefore not safe for use on darker skin tones.
The Nd:YAG wavelength at 1064 nm, which is ideal for treating skin tones 4, 5 and 6 (4 being tanned skin and 5 and 6 darker skin tones) as the absorption by melanin is much lower than with the Alexandrite wavelengthThe Lumenis Splendor X has been introduced to be a player in the solid state Nd:YAG and Alexandrite laser hair removal market. The gold standard for hair removal has always been considered Alexandrite 755nm for light skins and Nd:YAG 1064nm for dark skins.The Lumenis Splendor X combines both in a unique way with blended emission.Instead of firing a single wavelength at a time the Splendor X allows you to fire both wavelengths simultaneous in adjustable amounts to suit the skin type and hair types. This means you are target multiple chromophores at any given time given enhanced results across the board.The Lumenis Splendor X also allows the user to choose between square and round spot sizes with large spot sizesLumenis Splendor X Laser Hair RemovalThe Alexandrite wavelength at 755 nm, which is ideal for treating skin tones 1, 2 and 3 (fair and light skin tones). It is highly absorbed in melanin and is therefore not safe for use on darker skin tones.
The Nd:YAG wavelength at 1064 nm, which is ideal for treating skin tones 4, 5 and 6 (4 being tanned skin and 5 and 6 darker skin tones) as the absorption by melanin is much lower than with the Alexandrite wavelengthLaser Hair Removal
Details:2019 Lumenis Splendor X- Laser Hair Removal- Serial Number: SQEAY-19M-XXXXX (message for serial number)
- System Total Shot Count: 560,693
- Alex Shot Count: 221,437
- YAG Shot Count: 339,256
Includes:- Handpiece and Delivery System
- Square Spot Sizes: 2x2mm, 3x3mm, 5x5mm, 10x10mm, 14x14mm, 18x18mm, 20x20mm, 24x24, 27x27mm
- Fiber Pole
- Foot Switch
- System Key
- Operators Manual
- 30 Day Parts and Labor Warranty
|
Reviews
There are no reviews yet.