| Description | BODY TREATMENTS
● Body Contouring
● Cellulite Reduction
● Hair Removal
● Stretch Mark Reduction
● Skin Resurfacing
● ReVive Fusion ( Viora Revive for Labial correction)
● ReFit (Viora Refit for skin tightening and scars reduction) | Let’s Face It! We want to look our best at any age—not over-filled and over-stretched, just natural. We want to age gracefully, beautifully and elegantly. Inevitably, fine lines and wrinkles set in, and now there is a simple, minimally-invasive treatment that will address those concerns and have you out to dinner that same night. | - Muscoskeletal Disorders
- Degenerative arthritis
- Rheumatoid arthritis
- Cervical pain
- Sport injuries
- Frozen shoulder
- Muscle relaxation
- Pain management
| Laser Hair Removal
Details:- Serial Number: SQEAY-19M-XXXXX (message for serial number)
- System Total Shot Count: 560,693
- Alex Shot Count: 221,437
- YAG Shot Count: 339,256
Includes:- Handpiece and Delivery System
- Square Spot Sizes: 2x2mm, 3x3mm, 5x5mm, 10x10mm, 14x14mm, 18x18mm, 20x20mm, 24x24, 27x27mm
- Fiber Pole
- Foot Switch
- System Key
- Operators Manual
- 30 Day Parts and Labor Warranty
| 2017 Lumenis Lightsheer Desire with 3 Handpieces – HS, XC and ET – Includes 805 and 1060 nm wavelengths – Like-New Condition; Serial Number: 3796, Date of Manufacture 2/15/2017, Excellent Cosmetic and Operating Condition – Like New with low pulses! RECENTLY INSPECTED April 2021, Included Handpieces & Pulse Counts: HS 22×35 mm Spot Size Diode Handpiece = 132 Pulses; XC 12×12 mm Spot Size Diode Handpiece = 3,362 Pulses; ET 9×9 mm Spot Size 1060 Handpiece = 6,590 Pulses; Also Includes: Operator Manual, 2 Pair Operator Eyewear, 1 Pair Patient Eye Shields, (1) Key, and 120 Day Warranty | Includes:
Articulated Arm
2 Acuscan 120 Handpieces
125mm Incisional Handpiece
F-125 Attachments
Key |
| Content | 2018 Viora V30 RadioFrequency Skin Tightening StretchThe V30 system delivers the most effective results possible, quickly, safely, painlessly and with little to no downtime. Viora’s V20 & V30 multi-technology platforms are specifically designed to meet these challenges and more. Viora specializes in providing you with the most advanced technologies within one platform, so you can expand your practice as you need and on your time.By combining multiple technologies, the V20 & V30 multi-technology platforms enable you to offer multiple applications to your patients. Each technology is accessible via a different handpiece, and can be acquired separately, so you control your treatment menu.Viora’s V20 & V30 multi-technology platforms – part of the V-Series – provides treatment solutions for the most requested applications, including hair removal, skin rejuvenation, skin tightening, acne clearance and more! With FDA and CE approvals, V20 & V30 give you total control and flexibility. And with the ability to access Viora’s specially-developed combination protocols, superior clinical efficacy and patient satisfaction is waiting for you.Viora’s proprietary technology is the driving force behind the V20 & V30. Accessible via different handpieces, you determine which technologies you need and when. And since each handpiece can be acquired separately, you control your treatment menu, along with the convenience of deciding when to easily upgrade to additional technologies. Includes:
- Main System
V-ST Handpiece (RF Skin Treatments, 3 Individual Channels & 4th for Greater Depth)
- REF: V-ST2001
- S/N: ST1507023 S/W Version: 1.00.013
- Usage: 29 Hrs 47 Min
- Foot Pedal
- Interlock
- Power Cable Noteworthy:
- Login is: 1 2 3 4 LoginAlso Noting:
- There is no "Unlock Code" for any IPL or Nd:YAG or FR handpieces (Not included)Product Information- Brand: Viora
- Condition: Used
- Manufacturer: Viora
- Model Number: V30
Viora’s non-invasive medical devices address a wide range of concerns, treating today’s most commonly requested solution for anti-aging, body & facial contouring, circumferential reduction, acne clearance, stretch mark reduction, hair removal, skin tightening, skin lifting, skin resurfacing and cellulite reduction.Viora is the only full-body platform that offers complete body & face treatment solutions. Viora offers state-of-art radiofrequency treatment for skin tightening, cellulite reduction, and body contouring. Viora provides the most comprehensive and customizable treatment to fit every customer’s needs. VIORA V30
VIORA V30 IS A MULTI-TECHNOLOGY PLATFORM SPECIFICALLY DESIGNED TO MEET THE MOST TREATMENT CHALLENGES.
IT IS A ALL-IN-ONE AESTHETIC SOLUTION FOR BODY CONTOURING, CELLULITE REDUCTION, SKIN TIGHTENING & SKIN REJUVENATION. WHY VIORA V30?
GLOBAL BRAND | ALL IN ONE AESTHETIC SOLUTION | ERGONOMIC HANDPIECES | ZERO DOWNTIME FEATURES 2018 Viora V30 RadioFrequency Skin Tightening Stretch
VIORA TECHNOLOGIES
⦾ VIORA PCR TECHNOLOGY
⦾ VIORA CORE TECHNOLOGY
⦾ VIORA MULTI CORE TECHNOLOGY
⦾ VIORA SVC TECHNOLOGY
⦾ VIORA IONWAVE TECHNOLOGYViora’s CORE (Channeled Optimal RF energy) and Multi-CORE Technology allow independent heating depth control by applying three distinct RF frequencies (0.8, 1.7, and 2.45 MHz), which allows heating of the hypodermal tissue for fat volume reduction and dermal tissue for a lifting and tightening effect. Thanks to incorporated vacuum suction, RF energy penetrates deeper which provides almost immediate effect.Viora’s PCR technology includes variable pulse structures, enabling rapid treatments, among the fastest in the industryViora SVC (Switching, Vacuum, Cooling) Technology creates the most convenient, safe, and controlled treatment experience to benefit both practitioners and patients. The SVC’s Cooling feature utilizes advanced TEC technology to prevent epidermal damage, reduce pain, and speed up the recovery processThe Ionwave Technology integrated into the Infusion system delivers the LipoElim ampoule which encourages fat cell lipolysis, prevents future fat accumulation by blocking MMP-9 signals, and initiating an innovative anti-adipogenesis mechanism that suppresses adipose cell maturation and restricts fat storage. MEDICAL SKIN INDICATIONS TREATED BY VIORA DEVICES:
● Hyperpigmentation clearance
● Skin tightening
● Wrinkle reduction
● Skin resurfacing
● Skin rejuvenation
● Acne clearance
● Refine Fusion (wrinkle reduction)
● ReLift (Facial contouring, lifting)
● Post Acne Scar reduction
● Enlarged pore Shrinkage
● Skin hydration VIORA EXPECTATION AND POSSIBILITIES:
FACIAL TREATMENTS
● Acne Clearance
● Acne Scar Reduction
● Enlarged Pores Shrinkage
● Skin Tightening & Wrinkle
● Skin Rejuvenation
● Skin Hydration
● Hyperpigmentation
● Vascular Clearance
● ReFine Fusion
● ReLift | 2018 Vivace RF Microneedling Radio Frequency Acne ScarsTHE VIVACE EXPERIENCE
The most exciting new technology for aesthetic treatments is the combination of two methods previously used individually for skin rejuvenation, Microneedling and RF Energy. FDA-cleared for your safety, the newest generation, best-in-class Vivace RF Microneedling device, is designed for an incomparable, comfortable experience. Only Vivace boasts a precision robotic motor that brings discomfort to a virtual zero compared to any other device. The results are immediate and improve over time as well, giving you the best of both worlds. Our carefully developed recovery system ensures no one knows you just had a treatment. If you are looking for optimal results, there is no comparison to The Vivace Experience.What is Vivace Fractional RF Microneedling?
The Vivace RF Laser Radio Frequency is the newest generation of microneedling with radio frequency and is effective for fine lines and wrinkles, skin tightening, acne, acne scars, and skin tone, texture and pore size, both on and off the face. It is the most revolutionary contouring and skin tightening system for face, neck, hands and body available, producing immediate, pain-free results.Safe for all skin types, Vivace can offer similar results as ablative and fractional laser procedures, but with significantly less discomfort, downtime, and risk of complications. This revolutionary new treatment also addresses the limitations of older ‘traditional’ RF treatments and heats deeper tissues to a much higher level, which leads to greater collagen production, elastin remodeling and wound contraction previously unattainable with older technology. This is why the Vivace is a game changer in skin rejuvenation and tightening. CLICK HERE to learn moreSlate combines the best device with the newest breakthroughs in numbing, treatment serums and recovery care to create an optimal experience for you that might just keep you from needing other more invasive procedures down the road. The Vivace Experience provides the most dramatic results with less pain and less downtime. The results are both immediate and improve over time with multiple treatments. With results you can see, you’ll look and feel your best at any age.Slate Medspa is the premier Fractional RF Microneedling provider in NJ. We use the most advanced technology to provide a results-oriented skin rejuvenation program. New to Slate Medspa? Call us today at 201-477-5781 to schedule a free consultation and save 20% off your first treatment.How does Vivace Fractional RF Microneedling work?
The Vivace utilizes radio frequency and microneedling to heat the targeted area underneath the epidermis. The Vivace dramatically improves the treatment outcomes compared to other radio frequency microneedling systems.By using insulated needles, Vivace bypasses the epidermis and delivers powerful RF thermal energy to create tens of thousands of fractional coagulation zones in the dermis, facilitating a natural wound healing process. This promotes production of new collagen, remodeling of elastin and wound contraction, enhancing skin laxity. Because the thermal energy is delivered beneath the top layer of skin,Benefits of VIVACE:2018 Vivace RF Microneedling Radio Frequency Acne Scars
Minimizes/Eliminates Fine Lines and Wrinkles
Minimizes/Eliminates Acne Scars & Stretch Marks
Skin Tightening & Texture – Stimulates collagen and elastin production
Treat Sun Damage/Age Spots/Hyperpigmentation
8 Reasons why Slate LOVES Vivace™ RF Microneedling
You’ll see results quickly
Vivace works faster than any other microneedling or laser option. First, the RF Energy creates micro injuries deep in the skin in the form of a matrix. Healthy cells around the newly created matrix promote rapid healing, accelerating collagen production and skin tightening. Secondly, the invisible microchannels in the skin created by the superfine gold-tipped needles remain open for four to six hours allowing maximum absorption the key nutrients and serums applied during the treatment. This would include growth factors, HAs and other cosmeceuticals delivered to the skin in a way that no other treatment can, helping to rapidly rebuild new collagen and elastin.The average patient gets optimal results in just three treatments
Most patients experience noticeably softer, smoother and radiant skin, with improvements in tone, texture and laxity after just one treatment. We can typically achieve optimal results after only three sessions!The treatment is virtually painless
The Vivace Microneedle RF was designed for an incomparable, comfortable patient experience. The unique robotic motor is so precise, it brings the discomfort level to a virtual zero as compared to any other device. The Vivace’s ultra thin needles make it virtually pain-free. A numbing cream is applied before treatment for you to stay comfortable. Our patients here at Slate Medspa consistently report a pain level of “1” on a scale of 1 to 10.There’s no downtime
Vivace’s ultra-thin needles and robotic-assisted mechanism result in an exceptionally precise, even treatment with little-to-no bleeding. In addition, built-in LED Light therapy minimizes post-treatment redness. While we ask patients to wait until the next day before applying makeup, most feel comfortable going out without any makeup.It’s safe for almost any skin type
Patients with darker skin tones can have a more challenging time finding suitable skin resurfacing treatments, as lasers and peels that remove skin layers can risk permanent pigmentation changes. Vivace has 31 Adjustable depths, providing flexibility in treating entire depth or just down deep, bypassing damage to the top layer of skin. This means we can treat a broader array of skin types and tones with absolute precision. In addition, a variable pulse duration means the length of time the needle is engaged with tissue can be precisely controlled based on your skin profile. | 2020 CRYOMED HYPERMAX TALENTPRO
Electro-Magnetic Stimulation Technology
hyperMAX utilises Electro-Magnetic Stimulation technology to induce supramaximal contractions for
the growth and development of muscles. The magnetic field changes quickly inducing electrical currents in the tissue where neuronal membranes are depolarised and motor units in the target muscles are controlled to cause concentric contractions.How does it work?
Electro-Magnetic Stimulation helps to rebuild and repair muscle tissue, resulting in stronger and firmer muscles.
The strong Electro-Magnetic stimulation, of up to 3 Tesla, works deep to the hypodermis, influencing
muscle fibres and cell membranes to optimise cellular metabolism, supplying more oxygen for better blood circulation.Dualsculpt with Applicators
hyperMAX utilises Electro-Magnetic Stimulation technology to induce supramaximal contractions for the growth and development of muscles. The magnetic field changes quickly inducing electrical currents in the tissue where neuronal membranes are depolarised
and motor units in the target muscles are controlled to cause concentric contractions.2020 Cryomed HyperMAX TalentproIndications:- Muscoskeletal Disorders
- Degenerative arthritis
- Rheumatoid arthritis
- Cervical pain
- Sport injuries
- Frozen shoulder
- Muscle relaxation
- Pain management
Spinal Disorders- Acute/chronic lumbago
- Sciatica
- Spinal bifida
- Spondylitis chronic back pain
- Spinal disc disease
- Intramuscular stimulation
- Trigger Point Injection
Electro-Magnetic Stimulation TechnologyhyperMAX utilises Electro-Magnetic Stimulation technology to induce supramaximal contractions for
the growth and development of muscles. The magnetic field changes quickly inducing electrical currents in the tissue where neuronal membranes are depolarised and motor units in the target muscles are controlled to cause concentric contractions.How does it work?Electro-Magnetic Stimulation helps to rebuild and repair muscle tissue, resulting in stronger and firmer muscles.
The strong Electro-Magnetic stimulation, of up to 3 Tesla, works deep to the hypodermis, influencing
muscle fibres and cell membranes to optimise cellular metabolism, supplying more oxygen for better blood circulation. | 2019 Lumenis Splendor X- Laser Hair Removal
Lumenis Splendor X Laser Hair RemovalThe Alexandrite wavelength at 755 nm, which is ideal for treating skin tones 1, 2 and 3 (fair and light skin tones). It is highly absorbed in melanin and is therefore not safe for use on darker skin tones.
The Nd:YAG wavelength at 1064 nm, which is ideal for treating skin tones 4, 5 and 6 (4 being tanned skin and 5 and 6 darker skin tones) as the absorption by melanin is much lower than with the Alexandrite wavelengthThe Lumenis Splendor X has been introduced to be a player in the solid state Nd:YAG and Alexandrite laser hair removal market. The gold standard for hair removal has always been considered Alexandrite 755nm for light skins and Nd:YAG 1064nm for dark skins.The Lumenis Splendor X combines both in a unique way with blended emission.Instead of firing a single wavelength at a time the Splendor X allows you to fire both wavelengths simultaneous in adjustable amounts to suit the skin type and hair types. This means you are target multiple chromophores at any given time given enhanced results across the board.The Lumenis Splendor X also allows the user to choose between square and round spot sizes with large spot sizesLumenis Splendor X Laser Hair RemovalThe Alexandrite wavelength at 755 nm, which is ideal for treating skin tones 1, 2 and 3 (fair and light skin tones). It is highly absorbed in melanin and is therefore not safe for use on darker skin tones.
The Nd:YAG wavelength at 1064 nm, which is ideal for treating skin tones 4, 5 and 6 (4 being tanned skin and 5 and 6 darker skin tones) as the absorption by melanin is much lower than with the Alexandrite wavelengthLaser Hair Removal
Details:2019 Lumenis Splendor X- Laser Hair Removal- Serial Number: SQEAY-19M-XXXXX (message for serial number)
- System Total Shot Count: 560,693
- Alex Shot Count: 221,437
- YAG Shot Count: 339,256
Includes:- Handpiece and Delivery System
- Square Spot Sizes: 2x2mm, 3x3mm, 5x5mm, 10x10mm, 14x14mm, 18x18mm, 20x20mm, 24x24, 27x27mm
- Fiber Pole
- Foot Switch
- System Key
- Operators Manual
- 30 Day Parts and Labor Warranty
| Lumenis Lightsheer Desire (Include Handpiece)
comes fully loaded with 3 handpieces – ET (9X9), XC (12X12) & HS (22X35)the LightSheer DESIRE uses an 805nm diode wavelength. This wavelength is the industry’s Gold-Standard and has been clinically proven to safely and effectively treat all skin types Available Treatments: - Hair removal, permanent hair reduction, and the treatment for Pseudofolliculitis Barbae(PFB).
- Treatment of vascular lesions, including angiomas, hemangiomas, telangiectasia, leg veins and other benign vascular lesions.
- Treatment of benign pigmented lesions.
Unique features: - The “Gold standard” 805nm diode laser.
- 3 handpieces with various spot sizes.
- 2 advanced technologies.
The ET has a Sapphire ChillTip spot size of 9x9mm designed to treat small areas that require maximum precision and high fluence.The XC has a Sapphire ChillTip spot size of 12x12mm, providing optimal solution for large and small areas requiring higher fluence levels.The HS has a HIT 22x35mm spot size enabling use of low-fluence and a unique mechanism of pain reduction, providing safe, fast and comfortable treatment. | Product Specifications |
|---|
| ET | | | Laser Type | AIGaAs Diode Arrays | | Wavelength | 805 nm (nominal) | | Spot Size | 9 mm X 9 mm | | Repetition Rate | Up to 3 Hz | | Pulse repetition | 1 Pulse | | Fluence | 10-100 J/cm2 | | Pulse Width | 5-400 ms | | Peak Power | 1600 W | | Comfort Management | Chilltip contact cooling (5O C) | | Preset Parameters | Yse |
| XC | | | Laser Type | AIGaAs Diode Arrays | | Wavelength | 805 nm (nominal) | | Spot Size | 12 mm X 12 mm | | Repetition Rate | Up to 3 Hz | | Pulse repetition | 1 Pulse | | Fluence | 10-40 J/cm2 | | Pulse Width | 5-400 ms | | Peak Power | 2400 W | | Comfort Management | Chilltip contact cooling (5O C) | | Preset Parameters | Yse |
| HS | | | Laser Type | AIGaAs Diode Arrays | | Wavelength | 805 nm (nominal) | | Spot Size | 22 mm X 35 mm | | Repetition Rate | Up to 3 Hz | | Pulse repetition | 1 – 3 pulses | | Fluence | 4.5-12 J/cm2 | | Pulse Width | 30-400 ms | | Peak Power | 2300 W | | Comfort Management | Vacuum assisted (up to18inHg) | | Preset Parameters | Yse |
Lumenis Lightsheer Desire (Include Handpiece) – Like New | LUMENIS ACUPULSE 120 CO2 MACHINE
Includes:
Articulated Arm
2 Acuscan 120 Handpieces
125mm Incisional Handpiece
F-125 Attachments
KeySuperPulseTM TechnologyExceptional ablation/coagulation ratio.
Reach the desired treatment depth with a single pulse.
11 Built-in Treatment Modes.Maximum versatility with only two scanners.
Full parameter control for advanced users.
Short Pulse Duration.Enhanced patient comfort.
Lower chance of side effects.
Intuitive User Interface.Easy setup and quick treatments.
User presets for single-click treatments.11 Treatment Modes For Maximum Versatility
ACUSCAN120 FRACTIONAL SCANNERLUMENIS ACUPULSE 120 CO2 MACHINELaser Type:Co2
Wavelength:10,600 nm
AcuPulse
MultiModeTM SuperPulseTM CO2 Laser
AcuPulse is a complete ablative laser resurfacing workstation, featuring state of the art technology for all aesthetic resurfacing needs.
POWERFUL. VERSATILE. SIMPLE.Superficialfor moderate sun damage, fine lines, uneven texture, dyschromia, actinic keratosis and more.ComboDeep and Superficial combined together for sun damage, acne scars, wrinkles and more.Deepfor deeper lines and wrinkles, acne scars, uneven texture, dyschromia and more.StretchTouchfor skin furrows and textural irregularities.SURGITOUCH ADVANCED SCANNERFeatherTouchfor gental, single scan treatmentsToeTouchfor common foot ailments, such as plantar warts and ingrown toenailsSilkTouchfor more vigorous, double scan treatmentsPaintfor controlled, continous freehand placement on small areasFineTouchfor precise ablation of irregular pigmented lesions at various depths125MM INCISIONAL HANDPIECEBlephfor precise, clean incisions with minimal bleeding.Exceptional Ablation/Coagulation Ratio
When ablation depth is equal, more energy means more excess heat in the tissue. SuperPulse technology enables the deepest penetration with the lowest energy. This reduces patient discomfort, downtime and thermal damages.LUMENIS ACUPULSE 120 CO2 also enables shorter pulses, further enhancing patient safety. |