| Description | Advantages include:
– Precise tissue vaporisation and coagulation
– Improved surgical visibility and inherent sterilisation
– Excellent haemostatic with generally no dressing required
– Reduced surgical time and minimal postoperative discomfort
– Precise surgery with minimal damage to tissue
– Minimal necrosis adjacent to the target | Highly Precise, Non-Surgical, Medical Procedure System for Professionals. Doublo HIFU’s Speed is Innovative Performance! Treatment time is dramatically reduced with Hironic’s High-capacity Technology and with Doublo HIFU System you can treat twice the amount of patients than beforeNew Standard of
MFU System
1.No. 1 MFU proven by the patents2.MFU proven by cumulative sales and clinical cases3.Fastest treatment by Two-way round shooting and Auto Shot mode | Cutera Xeo LaserMultiple Technologies, Maximum FlexibilityIn today’s fast-paced aesthetic practices, maximum flexibility and upgradeability are paramount. Whatever your need, the Cutera Xeo Laser can provide the most versatile laser and light technologies on the market today. Whether you are interested in, Skin Fitness, hair removal, vascular therapies – or all the above – the Xeo can accommodate your specific needs through our upgradeable platform.The Cutera Xeo Laser combines the proven effectiveness of Cutera’s long-pulse Nd:YAG laser technology with the next generation of pulsed light treatments. The Cutera XEO can offer permanent hair reduction on all skin types, a complete range of vascular treatments and the next-generation in non-ablative combination skin therapy. | The ability to work specifically in the deep dermis, without damaging the epidermis, is regulated in the RF Secret by the delay time of fractional radiofrequency. The needles are inserted at a rate of milliseconds equal to a stamping process in the skin and also withdrawn immediately. Only after the needles are penetrated into the desired skin layer, is carried out for a few milliseconds, a radio frequency pulse to set heat damage. While the penetration into the skin, the needles remain always cold. In order to achieve a deep and superficial effect, the needle depths can be varied individually in the respective treatment passes. | Candela GentleMAX ProEstablished in 1970, Candela is a leading US-based global medical aesthetic device company with headquarters in Wayland, Massachusetts. The company’s technologies enable physicians to provide advanced energy-based solutions for a broad range of medical-aesthetic applications including benign vascular and pigmented lesions, scars, hair removal, facial resurfacing, wrinkle reduction, women’s health treatments, tattoo removal, acne, leg veins, cellulite, and body shaping. | ACTIVE OPTICAL SYSTEMS OPTIMA 518 IPL LASER includes: Handpiece, Footswitch, Operator Eyewear, Patient Eyewear, Cart, Key, Operator Manual, ultrasound gel, replacement fuses, replacement filters |
| Content | 2017 SPECTRUM DANA FRACTIONAL CO2 LASER
The Dana laser system has a unique ultra pulse mode that allows operators to adjust the pulse width and interval, ensuring a wide variety of surgical applications is possible. Advantages include:
– Precise tissue vaporisation and coagulation
– Improved surgical visibility and inherent sterilisation
– Excellent haemostatic with generally no dressing required
– Reduced surgical time and minimal postoperative discomfort
– Precise surgery with minimal damage to tissue
– Minimal necrosis adjacent to the targetWith the our advanced fractional laser you can treat the following indications.Indications 2017 SPECTRUM DANA FRACTIONAL CO2 LASER- Nevus
- Tumor elimination
- Freckles
- Hemorrhoid
- Birthmarks
- Osmidrosis
- Corn
- Warts
- Allergic spenitis
- Syringoma
- Snoring
- Phimosiectomoy (circumcision)
- Condyloma
- Skin resurfacing
- Fine wrinkles
- Dental surgery
Contra-indications Fractional laser treatment is inadvisable for the following conditions:- Epilepsy
- Keloid scar development
- Pacemaker
- Skin Cancer
- Photosensitising Drugs
- Warfarin
- Roaccutane / Accutane / Oratane
- Pregnancy and Lactation
- *Full list of contra-indications for fractional laser treatments available from Spectrum
Special Precautions using Fractional Laser- Use with care on skin types with a history of pigmentation and keloid scar formation
- Herpes Labialis [consider prophylactic oral antivirals]
- Isotretanoin use [within 12 months prior to treatment]
- Immunocompromised status or active systemic disease which may affect wound healing
How Fractional Laser worksDana Ultra Dream Pulse S-C02 fractional laser simultaneously treats the epidermis for pigmentation and fine lines. Additionally, the dermis for skin tightening, acne scars, deeper wrinkles and enlarged pores. The overall skin texture and the tone is improved. It is safe with a low pain level and can be used to treat the face, neck, chest, hand and arms.The fractional laser produces arrays of micro-ablative zones, eliminating discolorations at the epidermis, while sparing the tissues surrounding each ablative zone. At specific depth of dermis, the deeper micro-thermal zones cause immediate collagen contraction, and long-term collagen remodelling. During each treatment only 6-20% of the whole treatment area is ablated with 80-94% of tissue remaining intact and acting as a natural supporting bandage. As a result downtime is minimal and healing is fast.Depending on the applied energy level (energy, distance, degree), string thermal effect takes place in volumetric area depth from 100 to 1000 microns.Fractional Laser Technical Specifications
Multi CO2 Laser Specifications| Laser Type | C02 Laser | | Laser Tube | Sealed-off C02 | | Wavelength | 10.6 microns, invisible infrared | | Dominant Mode | | | Divergence | <3mrad | | Power on Tissue | CW 1W ~ 35W | | Peak Power | 315W at 90us | | Aiming Beam | 650nm, 3.5mW | | Operating Mode | Fractional Scanning Mode, Super Energy Pulse Mode,Ultra Energy Pulse Mode, Normal Energy Pulse Mode,Continuous Wave Mode |
| DOUBLO GOLD HIFU SYSTEMWhy choose Doublo HIFU System?
HIFU (High-Intensity Focused Ultrasound System) is a highly precise medical procedure using high-intensity focused ultrasound to heat and destroy the pathogenic tissue rapidly. The earliest widespread use of HIFU was as a treatment for prostate cancer.HIFU hybrid system for Face & Body
Doublo Gold is the ultimate HIFU system for precise Face Lifting & Body Contouring. Offering the fastest treatment by Two-way round shooting and Auto Shot mode.Non Invasive – No Pain – No Bleeding – No Downtime
Faster shot speed : Efficacy improved by repetitious shooting with 300 shots in 8 minutes. Entertain more patients with a faster treatment procedure.Multiple treatment areas
By treating the upper dermis with wound healing effect, facial pores and skin tone is improved as the fibroblast is rebuilt and collagen is boosted.Dermal tissue elasticity and collagen increase as fibroblast is rebuilt by wound healing effect from damaging sub-cutaneous tissue and derma layer with thermal coagulation.
Skin tightening to reduce wrinkle and increase lifting effect is done by creating thermal coagulation at subcutaneous fat and SMASDOUBLO GOLD HIFU SYSTEM Highly Precise, Non-Surgical, Medical Procedure System for Professionals. Doublo HIFU’s Speed is Innovative Performance! Treatment time is dramatically reduced with Hironic’s High-capacity Technology and with Doublo HIFU System you can treat twice the amount of patients than beforeDOUBLO GOLD HIFU SYSTEM Accessories: Power cord for cart
Clear plastic tray insert
Large washer and small lock/spring washer
2x black attachements
2x treatment parameters guide
Simple user manual
Full user manual + CDHighly Precise, Non-Surgical, Medical Procedure System for Professionals. Doublo HIFU’s Speed is Innovative Performance! Treatment time is dramatically reduced with Hironic’s High-capacity Technology and with Doublo HIFU System you can treat twice the amount of patients than beforeNew Standard of
MFU System
1.No. 1 MFU proven by the patents2.MFU proven by cumulative sales and clinical cases3.Fastest treatment by Two-way round shooting and Auto Shot mode | Cutera Xeo with Full Nd Yag and Low PulsesCutera Xeo Laser HandpiecesPearl Fractional Handpiece Features- Pearl Fractional has deep ablation and controlled thermal zone delivers maximum single-treatment results with less patient discomfort, downtime and risk than CO2
- Indicated for moderate to severe photoaging
- The 2790 nm wavelength (YSGG) controls thermal damage to maximize ablation while maintaining thermal stimulation and coagulation
- Controlled thermal zone minimizes risk of PIH and other complications
- Single treatment results are possible because our large 300 micron spot size ablates enough tissue in one pass
- Wound healing causes increased fibroblast activity and long term collagen deposition. Improvement is realized over six month period.
CoolGlide Nd Yag Laser Handpiece Features and SpecificationsThe CoolGlide laser is the first laser cleared for permanent hair reduction in all skin types.- Treat all skin types (I-VI) including tanned skin in the summer
- Patented PowerFlex™ technology provides fast treatments and high efficacy; allows independent control of fluence, pulse duration and repetition rates to tailor your treatment parameters
- Copper cooling provides the most efficient method of cooling for optimal skin protection and comfort
- Large spot size (10 mm) for maximum speed and optimal penetration at all follicle depths
- Wavelength: 1064 nm
- Fluence / Energy: Up to 300 J/cm2
- Spot Size: 3 mm, 5 mm, 7 mm, 10 mm
- Pulse Width: 0.1 – 30 msec or 10 – 100 msec
- Repetition Rate: 2 Hz to 10 Hz
Laser Genesis Handpiece FeaturesLaser Genesis is a staple of skin care for every doctor’s practice. It is a multi-purpose, all season, all skin type solution for overall skin health- Cutera Xeo Laser has a 1064 nm wavelength, combined with our patented microsecond technology, protects the epidermis, targets microvasculature and stimulates collagen production
- Improves wrinkles by gently heating the dermis; corrects diffuse redness, rosacea; smooths skin texture, shrinks pore size
- Peer reviewed journal shows evidence of erythema reduction and new collagen formation in the papillary dermis (Archives of Dermatology, Nov 2004)
- No downtime, minimal discomfort, no disposables.
LimeLight Handpiece Features and SpecificationsLimeLight is the most versatile, programmable device for treating vascular and pigmented lesions.- Three distinct preset programs (520-1100 nm) provide excellent hemoglobin and melanin absorption for uniform treatments and ease of use
- Clinical versatility permits treatment of multiple indications, including both low and high contrast pigmentation
- Features such as the industry’s fastest treatment speed and adjustable temperature control provide clinical versatility
- Only company with real-time calibration; this ensures accurate and consistent power output during treatment for reproducible results and patient safety
- Program A – 520 nm Filter – Fine Telangiectasia
- Program B – 560 nm Filter – Telangiectasia, Pigment
- Program C – 580 nm Filter – Solar Lentigines
- Spot Size: 10 mm x 30 mm
- Cooling: 5 °C, 10 °C or 20 °C
- Fluence / Energy: 5-30 J/cm2
- Repetition Rate: 2 Hz
AcuTip Handpiece FeaturesAcuTip delivers optimal results with targeted focal treatments of pigmented and vascular lesions–with no risk to surrounding skin.- Small tip allows aggressive pinpoint treatments – without compromising safety
- Selective wavelengths (500-635 nm) with short pulse durations deliver a powerful focal treatment
- Ideal for treatment of both low and high contrast pigmented lesions
- As powerful as Q-switched lasers for epidermal pigmentation; low risk of associated PIH
Pearl Handpiece FeaturesPearl delivers superior results in fewer treatments with less patient downtime than with non-fractional ablative lasers.- Indicated for fine wrinkles, dyschromia, skin tone and texture
- Full epidermal renewal is achieved with YSGG’s 2790 nm wavelength
- Patients receive 1-2 treatments without weeping and oozing and recover in 3-4 days
Excel Handpiece FeaturesThe first clinically effective long-pulsed Nd:YAG laser for both facial and lower extremity vascular lesions.- The Excel safely and effectively treats discrete vessels, high pressure vessels and deep veins
- Patented PowerFlex™ technology provides fast treatments and high efficacy; allows independent control of fluence, pulse duration and repetition rates to tailor your treatment parameters
- Contact copper cooling provides the most efficient method of cooling for optimal skin protection and comfort
- The “clearview” handpiece feature prevents vessel closure due to contact pressure
- Easy on-the-fly spot size adjustment (3, 5, 7 mm) facilitates optimal selection for safety and results
Titan V HP (small areas) + Titan XL HP (large areas) Handpieces Features and SpecificationsTitan is the most researched and peer-reviewed infra-red solution for deep dermal heating of all skin.- Titan’s light source generates energy from 1100 to 1800 nm for safe and effective volumetric heating of the dermis
- Titan candidates are often patients not yet ready for surgery
- When combined with other non-ablative procedures that improve conditions such as dyschromia, Titan’s toning effect enhances overall results
- Wavelength: 1100 – 1800 nm Infrared
- Fluence / Energy: 5 to 65 J/cm2
- Spot Size
- Titan V – 10 mm x 15 mm
- Titan XL – 10 mm x 30 mm
- Tx Cycle: 4 to 10 Seconds
ProWave Hair Removal Handpiece Features and SpecificationsProWave has multiple wavelength technology switches modes from Alexandrite to Diode to near Nd:YAG for maximum results, safety and versatility—all in a single high speed device.- ProWave (770-1100 nm), combines unrivaled treatment speed with optimal results and safety. Maximum versatility is achieved multiple wavelength technology enabling treatment modes from Alexandrite to Diode to near Nd:YAG
- Clinical studies showed > 80% hair reduction six months post three treatments
- Wavelength: 770 – 1100 nm
- Fluence: 5 to 35 J/cm2
- Spot Size: 10 mm x 30 mm
- Repetition Rate: 2 Hz
Cutera Xeo Laser System Specifications Cutera Xeo with Full Nd Yag and Low Pulses- Dimensions: 12″ W x 19″ D x 35″ H
- System Cooling: Internal, self-contained
- Electrical Info
- 115 V | 60 Hz | 20A
- 230 V | 60 Hz | 20A | 1 Phase
- Weight: 135 lbs
| CUTERA SECRET RF 2.0CUTERA SECRET RF 2.0 MICRONEEDLING RADIO is a fractional micro-needling system (fractional radiofrequency) that exceeds the capabilities and limitations of fractional laser significantly. It is a system for extensive skin structure improvement and treatment of hyperhidrosis (radio frequency thermotherapy RFTT), based on both monopolar and fractionated on, bipolar radio frequency. An exact adjustment of the depth of the microneedles and the cold passing the epidermis allow the energy output directly into the target layer.
The needle depth is 0.5 mm to 3.5 mm can be varied, thereby opening up a wide range of treatments. The adjustable intensity of the RF energy allows for the treatment of various areas of the body with different energy performance.The ability to work specifically in the deep dermis, without damaging the epidermis, is regulated in the RF Secret by the delay time of fractional radiofrequency. The needles are inserted at a rate of milliseconds equal to a stamping process in the skin and also withdrawn immediately. Only after the needles are penetrated into the desired skin layer, is carried out for a few milliseconds, a radio frequency pulse to set heat damage. While the penetration into the skin, the needles remain always cold. In order to achieve a deep and superficial effect, the needle depths can be varied individually in the respective treatment passes.Dermal Remodeling from the Inside Out
Demand for non-surgical aesthetic procedures with little to no downtime is on the rise. More than 70% of patients are bothered by signs of aging such as fine lines and wrinkles as well as skin texture and discoloration.1Secret RF is a novel fractional radio frequency (RF) micro-needling system for tissue coagulation and hemostasis designed to stimulate and remodel collagen and address the common signs of aging. It is ideally suited for use on patients who wish to revitalize and refresh the appearance of their skin on all skin types. By adjusting the micro-needles, Secret RF can deliver energy at various depths, so that treatments can be tailored to address each patients individual concerns such as fine lines, wrinkles, acne scars, photoaging and striae at the depth required.Secret RF System
Secret RFs unique technology and customized delivery of energy enables providers to tailor treatments for a variety of skin concerns on all skin types.Customized Dermal Remodeling
Secret RF induces dermal remodeling by applying precisely controlled RF energy directly into various depths of skin from 0.5-3.5 mm – with minimally invasive micro-needles to spare the epidermis and reduce patient downtime.Skin Revitalization and Resurfacing Secret RF is a radio frequency (RF) fractional microneedling system that helps you deliver tailored energy to improve fine lines, wrinkles, and scars from the inside out. Secret RF in action
Applications include fine lines and wrinkles, photoaging, scarring, acne scars, striaeSecret RF technology Handpieces
Two sizes of treatment tips – 25 and 64 pin – give you customizable options for treating the face and body with precision and efficiency.
Power:20 W ± 20%
RF frequency:2 Mh ± 20%
Intensity:0 ~ 100 Level (10 levels)
Repeat:0.2 / 0.5 / 1/2 sec / individually.
Needle Size:0.3 mm
Info about needles:25 electric needles (5 x 5, 7.8 mm x 7.8 mm / height: 1.95 mm (standard) and 16 electric needles (4 x 4, 7.8 mm x 7.8 mm / height 2.6 mm (optional)
Treatment range:1 x 1cm
Adjustable Depth:0.5 ~5 mm (0.1 steps)
Treatment duration:50 ms ~ 950 ms
Electrical power:100 ~ 240 VAC, 50/60 Hz, 220 VAMonopolar RF
Power:520 W ± 20%
RF frequency:2 Mh ± 20%
RF electrode:monopolar
Repeat:CW
RF electrode size:15APPLICATIONSFacialsNon-surgical facelift
Skin tightening
Pore reduction
Wrinkle reduction
Skin Rejuvenation (illumination)
Acne scars
Body treatmentsScar
Keratosis pilaris (Keratosis pilaris)
Stretch marks | 2017 Candela GentleMAX Pro Device DetailsThe Candela GentleMax Pro yields high energy, subjecting patients to fewer laser pulses providing faster treatment times with the 24mm spot size, the largest spot found on any hair removal laser. Candela’spatented Dynamic Cooling Devise (DCD) technology protects the upper layers of skin with cooling bursts of cryogen. DCD cooling offers optimal treatment with minimal side effects.| Distributor | Candela |
|---|
| Manufacturer | Candela |
|---|
| Model | GentleMAX Pro |
|---|
| Manufactured Year | 2017 |
|---|
| Specific Equipment Type | Dual Wavelength Laser |
|---|
| Sale Price | 12500 |
|---|
| Treatments Performed | Hair Removal, Vascular, Pigmentation
Skin Rejuvenation
Skin Tightening |
|---|
| Handpieces | Standard Handpiece DCD 12-18mm , Large Spot Size Handpiece DCD 22-24mm |
|---|
| Shot Counts | None |
|---|
| Wavelengths | 755nm
1064nm |
|---|
| Consumables used by device | Windows, Distance Gauges |
|---|
| Consumables with purchase | 3 x Operator goggles, 1 x patient goggles, distance gauges, windows |
|---|
| Annual Service Price | Servicing available through Candela |
|---|
| Service Contract Price | $11,000 per annum |
|---|
| Additional Information | Any additional information can be sent on request |
|---|
| |
|---|
Treatments:2017 Candela GentleMAX Pro Device Details- Hair Removal
- Beard Bumps
- Facial Lesions
- Fine Lines and Wrinkles
- Leg Veins
- Skin Tightening
- Vascular Lesions
- Warts
- Skin Rejuvenation
- Hemangiomas
- Birthmarks
- Freckles
- Melasma
- Mevus of Ota
- Pigmented Lesions
- Sun / Age Spots
The Candela GentleMax Pro yields high energy, subjecting patients to fewer laser pulses providing faster treatment times with the 24 mm spot size, the largest spot found on any hair removal laser.Fast – With 24 mm spot size and repetition rates up to 2 Hz, the The Candela GentleMax Pro yields high energy, subjecting patients to fewer laser pulses providing faster treatment times with the 24 mm spot size, the largest spot found on any hair removal laser. It has two wavelengths, the 755 Alexandrite and the 1064 ND:yag, allowing you to offer many treatment options.Candela’s patented Dynamic Cooling Devise (DCD) technology protects the upper layers of skin with cooling bursts of cryogen. DCD cooling offers optimal treatment with minimal side effects. offers fast treatment times with it’s spot size.Powerful – 26,333 watts peak power, capable of delivering fluences up to 100 J/cm² for vascular applications, and hair removal energy in pulse duration as short as 3 ms for unparalleled treatment efficacies.Treats all skin types – Deep penetration with minimal scattering of laser energy makes the GentleMax Pro ideal for all skin types, particularly dark and tanned skin.Versatile – Non-ablative treatment, including fine lines and wrinkles, and for pseudofolliculitis barbae (PFB), or beard bumps, leg and facial veins.Patented Epidermal Cooling – Candela’s Dynamic Cooling Device represents an adjustable epidermal protection technology to maximize patient safety and comfort.Date of Manufacture – 2017Accessories Included with Purchase – Specialty 1.5, 3mm, 3x10mm Handpiece, 6, 8, 10, 12, 15, 18mm Handpiece, Full Set of Distance Gauges, Distance Gauge Case, Patient Eyewear, Treatment Goggles, Foot Pedal, Fiber Pole, System Key, System Interlock Key, Treatment Guidelines, and User Manual. | Active Optical Systems Optima 518 IPL LaserHandpiece (Standard):Multipurpose Wavelength Mark-II
Handpiece (Optional):Facial Treatments
Pulse Interval/Repetition Rate:0.5 – 2 Seconds
Maximum Output Treatment Pattern:22 Joule /cm 2
Output Power:11-31 Joule / cm 2 , up to 4000 W
Cooling System:Improved Air Cooling
Control:Advanced Software Interface
Lamp’s Life Span:200,000 Flashes (minimum)
Treatment Area/Spot Size:15 x 50 mm, (7.5 cm 2)
Wavelength:420 – 1,100 nm
Weight:88.18 lbs (40Kg) (including stand)
Dimensions:17.32 inches x 17.72 inches x 39.37 inches (44cm x 45cm x 100cm)
Mains:220-230 VAC, 50/60 Hz; 100-120 VAC, 50/60 Hz
Max Mains Power:600 VA
Treatments Variety:
Skin Rejuvenation
Pigmentation Treatment
Acne Treatment
Hair Removal
Hair Removal – Deep Follicles
Hair Removal – Sensitive Skin
Vascular (Facial) Treatment
Tattoo Removal
ACTIVE OPTICAL SYSTEMS OPTIMA 518 IPL LASERr uses 12 preset programs. The programs are set in a consecutive, energy intensity increasing order, as specified by the tables of settings, covering all types of hair and skin combinations to be treated.
12 Programs
1 – Very Dark Skin, Fitzpatrick Skin Type IV
2 – Dark Skin, Fitzpatrick Skin Type IV
3 – Dark Skin, Fitzpatrick Skin Type III
4 – Dark Skin, Fitzpatrick Skin Type III
5 – Medium Skin, Fitzpatrick Skin Type II
6 – Medium Skin, Fitzpatrick Skin Type II
7 – Light Skin, Fitzpatrick Skin Type II
8 – Light Skin, Fitzpatrick Skin Type I
9 – Very Light Skin, Fitzpatrick Skin Type I
10 – Very Light Skin, Fitzpatrick Skin Type I
11 – Very Light Skin, Fitzpatrick Skin Type I
12 – High Power, Fitzpatrick Skin Type IActive Optical Systems Optima 518 IPL LaserOptima-518-Classic
The Optima – 518 Classic was designed to answer the needs of sophisticated practitioners who want to provide state of the art treatment to their patients on one hand, based on proven and tested treatment protocols and on the other hand to have the ability to reach new and improved protocols by conducting innovative clinical investigations.The Optima – 518 Classic, based on active’s GEM-PL technology, sets the pulse pattern according to the selected treatment type, skin color, skin photosensitivity and treatment depth. The treatment protocols and different pulse patterns take into account the tissue’s TRT (Thermal Relaxation Time) and the combined knowledge accumulated from thousands of treatments done during the years and clinical investigations done to confirm the findings.ACTIVE OPTICAL SYSTEMS OPTIMA 518 IPL LASERNew Handpiece Design The Optima – 518 Classic is the first model to use the new Mark II which enables a multipurpose handpiece:
* Faster treatments – up to 0.5 Seconds Between pulses.
* Real-time handpiece temperature control.
* Contemporary and stylish design.
* Light weight design – 25% less weight to improve the therapists’ comfort.Research program for clinical investigations, the self setting program allows researchers to set the treatment’s parameters according to their needs. Allowing advanced research with the device. The energy levels in the self setting program can reach 31J cm 2 with high intensity of 4000 W.ACTIVE OPTICAL SYSTEMS OPTIMA 518 IPL LASER Approvals
* CE MDD Intl. Medical Standard
* FDA U.S. Safety Standard
* ISO-13485 Med. Production STD
* IEC 60-601-1 Medical Safety STD
* CFS Gov. Health Approval
* CSA Can. & U.S. Safety App
* TGA Australian health STD. |