| Description | Included Handpieces:
HS 22×35 mm Spot Size Diode Handpiece
XC 12×12 mm Spot Size Diode HandpieceAlso Includes:
Operator Manual
2 Pair Operator Eyewear
1 Pair Patient Eye Shields
2 Keys | 2017 Lumenis Lightsheer Desire with 3 Handpieces – HS, XC and ET – Includes 805 and 1060 nm wavelengths – Like-New Condition; Serial Number: 3796, Date of Manufacture 2/15/2017, Excellent Cosmetic and Operating Condition – Like New with low pulses! RECENTLY INSPECTED April 2021, Included Handpieces & Pulse Counts: HS 22×35 mm Spot Size Diode Handpiece = 132 Pulses; XC 12×12 mm Spot Size Diode Handpiece = 3,362 Pulses; ET 9×9 mm Spot Size 1060 Handpiece = 6,590 Pulses; Also Includes: Operator Manual, 2 Pair Operator Eyewear, 1 Pair Patient Eye Shields, (1) Key, and 120 Day Warranty | Includes:
Footswitch
Operators Manual
AntiFreeze Coolant
Patient & Operator Eyewear | Laser Hair Removal
Details:- Serial Number: SQEAY-19M-XXXXX (message for serial number)
- System Total Shot Count: 560,693
- Alex Shot Count: 221,437
- YAG Shot Count: 339,256
Includes:- Handpiece and Delivery System
- Square Spot Sizes: 2x2mm, 3x3mm, 5x5mm, 10x10mm, 14x14mm, 18x18mm, 20x20mm, 24x24, 27x27mm
- Fiber Pole
- Foot Switch
- System Key
- Operators Manual
- 30 Day Parts and Labor Warranty
| Includes:
Various Handpieces
1x 3 Button Fingerswitch Handpiece
1 Forcep
1 Infared Thermometer
1 Footswitch
1 Professional Cart
1 Suction Filter
1 Operator Manual
Brochures | 2017 Lumenis M22 with ResurFX & IPL in Like-New Condition; Manufactured 10/22/2017; Based Unit Serial Number 11860, IPL Handpiece Serial Number: 4751; Nd Yag Serial Number: Perfect Cosmetic and Operating Condition, Single Owner; Handpieces Included & Total Pulse Counts: IPL Handpiece Total Pulse Count = 908; ResurFX Handpiece Pulse Count = 16 Pulses; Includes Expert Filters: 515nm, 560nm, 590nm, 615nm, 640nm, 695nm, and 755nm; Also Includes: Footswitch, Interlock, Operator Manual. |
| Content | 2016 LUMENIS LIGHTSHEER DESIRE PERMANENT LASER HAIR REDUCTION2016 Lumenis Lightsheer Desire Permanent Laser Hair Reduction
Great clinical results begin with the LightSheer 805 nm diode laser empowered by two advanced technologies.The Gold Standard in Permanent Laser Hair Reduction
More and more people desire to have permanent hair reduction. They want a treatment that is effective, fast and comfortable. To meet these needs, Lumenis, a leader in laser and energy based technologies, developed the LightSheer DESIRE, the new generation of Laser Hair Reduction systems, so you can grow your business by offering your patients what they DESIRE. The Gold Standard in Permanent Laser Hair Reduction.Included Handpieces:
HS 22×35 mm Spot Size Diode Handpiece
XC 12×12 mm Spot Size Diode HandpieceAlso Includes:
Operator Manual
2 Pair Operator Eyewear
1 Pair Patient Eye Shields
2 KeysSuperior Performance
– Versatile 805nm diode laser
– 2 different Models to select from
– Multiple handpieces with various spot sizes
– 2 advanced technologies
– Upgradable features: add capabilities as your practice grows.Advanced Laser Hair Removal TechnologyGreat clinical results begin with the LightSheer 805 nm diode laser empowered by two advanced technologies:
1. Vacuum Assisted High-Speed Integrated Technology – A large 22×35 mm spot size enables the use of low-fluence and a unique mechanism for pain reduction which provides effective, fast and comfortable treatments for your clients.
2. ChillTip™ Technology – Integrated contact cooling provides epidermal protection for treatment areas requiring precision and higher fluence.Lightsheer Desire Specifications
High Speed (HS) Handpiece
Laser Type:Diode
Wavelength:805 nm
Spot Size:22 x 23 mm
Repetition Rate:Up to 3 Hz
Pulse Repetition:1-3 Pulses
Fluence:4.5-12 J/cm2
Pulse Width:30-400 ms
Peak Power:2310 WXC Handpiece
Laser Type:Diode
Wavelength:805 nm
Spot Size:12 x 12 mm
Repetition Rate:Up to 3 Hz
Pulse Repetition:1 Pulse
Fluence:10-40 J/cm2
Pulse Width:5-400 ms
Peak Power:1920 WLightSheer® DESIREThe starting point to your successMore and more people desire to have permanent hair reduction. They want a treatment that is effective, fast and comfortable.To meet these needs, Lumenis, a leader in laser and energy based technologies, developed the LightSheer DESIRE, the new generation of Laser Hair Reduction system from the LightSheer Family of products, so you can grow your business by offering your patients what they DESIRE. | Lumenis Lightsheer Desire (Include Handpiece)
comes fully loaded with 3 handpieces – ET (9X9), XC (12X12) & HS (22X35)the LightSheer DESIRE uses an 805nm diode wavelength. This wavelength is the industry’s Gold-Standard and has been clinically proven to safely and effectively treat all skin types Available Treatments: - Hair removal, permanent hair reduction, and the treatment for Pseudofolliculitis Barbae(PFB).
- Treatment of vascular lesions, including angiomas, hemangiomas, telangiectasia, leg veins and other benign vascular lesions.
- Treatment of benign pigmented lesions.
Unique features: - The “Gold standard” 805nm diode laser.
- 3 handpieces with various spot sizes.
- 2 advanced technologies.
The ET has a Sapphire ChillTip spot size of 9x9mm designed to treat small areas that require maximum precision and high fluence.The XC has a Sapphire ChillTip spot size of 12x12mm, providing optimal solution for large and small areas requiring higher fluence levels.The HS has a HIT 22x35mm spot size enabling use of low-fluence and a unique mechanism of pain reduction, providing safe, fast and comfortable treatment. | Product Specifications |
|---|
| ET | | | Laser Type | AIGaAs Diode Arrays | | Wavelength | 805 nm (nominal) | | Spot Size | 9 mm X 9 mm | | Repetition Rate | Up to 3 Hz | | Pulse repetition | 1 Pulse | | Fluence | 10-100 J/cm2 | | Pulse Width | 5-400 ms | | Peak Power | 1600 W | | Comfort Management | Chilltip contact cooling (5O C) | | Preset Parameters | Yse |
| XC | | | Laser Type | AIGaAs Diode Arrays | | Wavelength | 805 nm (nominal) | | Spot Size | 12 mm X 12 mm | | Repetition Rate | Up to 3 Hz | | Pulse repetition | 1 Pulse | | Fluence | 10-40 J/cm2 | | Pulse Width | 5-400 ms | | Peak Power | 2400 W | | Comfort Management | Chilltip contact cooling (5O C) | | Preset Parameters | Yse |
| HS | | | Laser Type | AIGaAs Diode Arrays | | Wavelength | 805 nm (nominal) | | Spot Size | 22 mm X 35 mm | | Repetition Rate | Up to 3 Hz | | Pulse repetition | 1 – 3 pulses | | Fluence | 4.5-12 J/cm2 | | Pulse Width | 30-400 ms | | Peak Power | 2300 W | | Comfort Management | Vacuum assisted (up to18inHg) | | Preset Parameters | Yse |
Lumenis Lightsheer Desire (Include Handpiece) – Like New | ACTIVE OPTICAL EXTRA 818 IPL HAIR REMOVAL MACHINEIncludes:
Footswitch
Operators Manual
AntiFreeze Coolant
Patient & Operator EyewearHandpieces:Hair Removal Handpiece and Facial Handpiece
Chilled Tip:Up to 4c
Pulse Interval:0.5~2 Seconds
Output Power:11-31 joule/cm2, upto 4,000W
Cooling System:Revolutionary dual cooling
Control:Intuitive touch screen control
Lamp’s Life Span:250,000 Flashes (Universal), 200,000 Flashes (Facial)
Treatment Area:7.5 cm2 (15*50mm) Universal, 4.5 cm2 (15*30mm) Facial
Wavelength:420-1100 nm
Weight:42Kg (including Stand, if device is not a table top)
Dimensions:44cm x 45cm x 100cm
Extra-818
Skin Rejuvenation
Pigmentation Treatment
Acne Treatment
Hair Removal
Vascular (Facial) TreatmentThe combination of tested treatment protocols with high end engineering makes the Extra – 818 the perfect device for leading clinics.Revolutionary Cooling System
The Extra – 818 has a dual cooling system, controlled and monitored in order to ensure long lifetime to the lamp and a comfortable treatment to the patient.Competitive cooling systems “freeze” the skin so that during the treatment the skin temperature will rise to a bearable level. However, this “freezing” temperature might limit the results because the follicles will not reach the coagulation temperature. To ensure optimal results Active installed a special Processor that prevents overcooling the skin and maintains a uniform low temperature of the “glass” throughout the treatment. This revolutionary system enables the Extra – 818 to provide best results with optimal patient comfort.Research Program ACTIVE OPTICAL EXTRA 818 IPL HAIR REMOVAL MACHINE
For clinical investigations, the self setting program allows researchers to set the treatment’s parameters according to their needs. Allowing advanced research with the device.
The energy levels in the self setting program can reach 31Jcm2 with high intensity of 4,000W.The Active Optical Extra 818 IPL Hair Removal and Skin Rejuvenation is the outcome of more than a decade of treatments and thousands of devices operated worldwide. It contains It contains unique features:
* Contemporary touch screen control
* Built-in Patch Test procedure for examining the optimal energy level
* A stunning number of 450,000 flashes in both lamps.The Extra – 818, based on Active’s GEM-PL technology, sets sets a specific Pulse Pattern according to the selected treatment type, skin color, skin photosensitivity and treatment depth.
The treatment protocols and different pulse patterns take into account the tissue’s TRT (Thermal Relaxation Time) and the combined knowledge accumulated from thousands of treatments done during the years and clinical investigations done to confirm the findings. | 2019 Lumenis Splendor X- Laser Hair Removal
Lumenis Splendor X Laser Hair RemovalThe Alexandrite wavelength at 755 nm, which is ideal for treating skin tones 1, 2 and 3 (fair and light skin tones). It is highly absorbed in melanin and is therefore not safe for use on darker skin tones.
The Nd:YAG wavelength at 1064 nm, which is ideal for treating skin tones 4, 5 and 6 (4 being tanned skin and 5 and 6 darker skin tones) as the absorption by melanin is much lower than with the Alexandrite wavelengthThe Lumenis Splendor X has been introduced to be a player in the solid state Nd:YAG and Alexandrite laser hair removal market. The gold standard for hair removal has always been considered Alexandrite 755nm for light skins and Nd:YAG 1064nm for dark skins.The Lumenis Splendor X combines both in a unique way with blended emission.Instead of firing a single wavelength at a time the Splendor X allows you to fire both wavelengths simultaneous in adjustable amounts to suit the skin type and hair types. This means you are target multiple chromophores at any given time given enhanced results across the board.The Lumenis Splendor X also allows the user to choose between square and round spot sizes with large spot sizesLumenis Splendor X Laser Hair RemovalThe Alexandrite wavelength at 755 nm, which is ideal for treating skin tones 1, 2 and 3 (fair and light skin tones). It is highly absorbed in melanin and is therefore not safe for use on darker skin tones.
The Nd:YAG wavelength at 1064 nm, which is ideal for treating skin tones 4, 5 and 6 (4 being tanned skin and 5 and 6 darker skin tones) as the absorption by melanin is much lower than with the Alexandrite wavelengthLaser Hair Removal
Details:2019 Lumenis Splendor X- Laser Hair Removal- Serial Number: SQEAY-19M-XXXXX (message for serial number)
- System Total Shot Count: 560,693
- Alex Shot Count: 221,437
- YAG Shot Count: 339,256
Includes:- Handpiece and Delivery System
- Square Spot Sizes: 2x2mm, 3x3mm, 5x5mm, 10x10mm, 14x14mm, 18x18mm, 20x20mm, 24x24, 27x27mm
- Fiber Pole
- Foot Switch
- System Key
- Operators Manual
- 30 Day Parts and Labor Warranty
| ELLMAN PELLEVE S5 REDUCTION SYSTEM
The Pelleve S5 System is a new generator based on the proven Surgitron technology. In addition to powering the Pelleve handpieces, it provides maximum control in precision cutting with minimal thermal damage to surrounding tissues, plus more versatility than other energy-based technologies, including:Wrinkle reduction treatment with the new GlideSafe(TM) handpieces
Hundreds of surgical electrodes and accessories for most specialties
Portable and light weight – ideal for office and clinic environmentsWxHxD: 9.5 x 7.1 x 16.5
Weight: 26 lbs.
Ambeint Temperature: +10 degrees C – +40 degrees C
Relative Humidity: 30% – 75%
Normal Line Voltage: 100V, 120V / 220V, 240V – + 10%
Line Frequency: 60Hz./50Hz.
Input current at max output power: 3.4A/1.5A
Pelleve Wrinkle Reduction System
Ellagance Through Science
Pelleve S5 SystemPelleve precisely delivers energy to the dermal tissue using advanced radiofrequency technology to induce collagen contraction without damaging the epidermis. The result is skin tightening and contouring with a noticeable improvement in skin quality and texture.Pelleve’s unique radiofrequency technology emits energy in the form of electromagnetic waves, which create a heated treatment zone. Increased resistance causes heat buildup at the subdermal junction. Heat induces collagen denaturation and collagen contraction. Protein stimulation causes new collagen formation and production in the dermis which also results in epidermal tightening. Existing bands of collagen tighten in subcutaneous fat, creating a superficial tightening of the epidermis.Unparalleled Safety ELLMAN PELLEVE S5 REDUCTION SYSTEM
The Pelleve System delivers continuous radiofrequency energy which enables the clinician to choose how much energy to deliver and in what areas. By using a combination of the different sizes of Pelleve handpieces that are available each patient’s specific areas of concern can be addressed, resulting in patients receiving just the right amount of energy. The new GlideSafe handpieces feature an innovative sensor designed to stop energy flow when the device senses loss of contact with skin, further enhancing the safety.Non invasive, non ablative office treatment
Patients today are seeking affordable, non invasive alternatives to ablative and surgical procedures. The Pelleve System fills that void.Minimal side effects
A Pelleve treatment is virtually pain free and no anesthetic is used for the treatment. The patient may experience some transient erythema or edema, which is typically gone in a few hours.PelleFirm is a non-invasive cellulite treatment that uses radiofrequency energy and massage to deeply heat tissues and temporarily reduce the appearance of cellulite.ELLMAN PELLEVE S5 (TM) HandpiecesPelleve GlideSafe handpieces feature an innovative sensor designed to stop energy flow when the device senses loss of contact with skin – resulting in a more comfortable treatment for the patient. The GlideSafe Handpieces are available in 4 sizes – 7.5 mm, 10 mm, 15 mm, 20 mm – to allow the physician clinician to customize to the individual patient. The compact ergonomic design enables practitioners to comfortably maneuver around the contours of the face, including areas that are difficult to access such as the periorbital region. Each handpiece delivers multiple hours of treatment (activation) time so doctors have the option of customizing each patient’s treatment by using different size handpieces for different areas of the face. This advanced feature allows users to treat multiple patients and perform many procedures using the same charged handpiece.Surgical Versatility
An innovative multi-modality system, the Pelleve Wrinkle Reduction System offers physicians unmatched versatility in a compact design. Beyond skin tightening, the ELLMAN PELLEVE S5 platform facilitates scores of procedures with the availability of hundreds of monopolar and bipolar electrodes.Skin tightening plus surgical procedures
You can use the Pelleve system to deliver aesthetic treatments plus surgical treatments with the S5 platformAdds value to your practice
An ideal procedure to delegate to physician extenders and bundle with other servicesPractice profitability
Low operating costs yield enhanced profitability relative to treatment feeWide range of surgical electrodesFor use with the Pelleve Generator and all other Ellman generators are hundreds of standard and specialty surgical electrodes facilitate procedures ranging from minimally invasive treatments through full surgical procedures. Unlike conventional ESU generators, the Ellman generators are high-frequency radiofrequency devices that enable precise cutting and control with minimal thermal damage. Minimizing tissue damage improves aesthetic outcomes and reduces recovery time. | 2017 Lumenis M22 IPL with ResurFX| Manufacturer Notes |
|---|
| M22 is a modular multi-application platform for the treatment of over 30 skin conditions and hair removal.Available Treatments with M22:– Acne Scar Treatment
– Hair Removal
– Non-Ablative Skin Resurfacing
– Photorejuvenation
– Pigmentation Treatment
– Scar Revision
– Vascular / Leg Vein Treatment
– Dark Tattoo RemovalUsed by physicians around the world, M22 enables you to treat more types of patients and conditions with better outcomes.4 Multiple Technologies In One Modular SystemM22 grows with your practice and can expand to your treatment needs and adapts to future applications as they emerge.Universal IPL
Optimal Pulse Technology (OPT)
Single handpiece with changeable filters and lightguides
For IPL skin treatments using photorejuvenationResurFX
The only True fractional non-ablative, with CoolScan scanner
No disposables
For skin resurfacingMulti-Spot Nd:YAG
The only one with Multiple Sequential Pulsing (MSP)
2 sized lightguides, changeable in seconds
For treatment of leg veins and vascular lesionsQ-Switched Nd:YAG
Homogenous beam profile for enhanced treatment safety and efficacy
For skin toning*, dark tattoos removal, and combination treatments
*Skin toning by treatment of pigmented lesions |
2017 Lumenis M22 IPL with ResurFX and Q-Switched Nd:YAG A modular multi-application system for hair removal and various skin conditions Details:M22 Serial Number: 21171 M22 Date of Manufacture: 2017-07-17 Total IPL Pulses: 19,186 Total ResurFX Pulses: 10,772 Q-Switched Nd:YAG Pulses: 385,505
Includes:IPL Handpiece Complete Standard IPL filters: 515, 560, 590, 615, 640, 695, 755nm, and Calibration Specialty IPL Filters: Acne and Vascular IPL Light Guides: (1)35 x 15 mm2; (1)15 x 8 mm2, (1) 6mm- round ResurFX Handpiece with SapphireCool Tip Q-Switched Nd:YAG Handpiece Foot Switch Power Cord 30 Days Parts and Labor Warranty
|
System specifications
Dimensions:[without ResurFX] 44 x 50.5 x 47 cm (17 x 20 x 18.5 inches)
Dimensions:[with ResurFX] 44 x 50.5 x 61.5 cm (17 X 20 X 24 inches)
Weight:[without ResurFX] 40 kg / 88 lbs
Weight:[with ResurFX] 55 kg / 121 lbs
Electrical requirements:100 240 VAC ±10%, 15A max., 50/60 Hz, single phase, dedicated line M22 is a modular multi-application platform for the treatment of over 30 skin conditions and hair removal. Available Treatments with M22:– Acne Scar Treatment
– Hair Removal
– Non-Ablative Skin Resurfacing
– Photorejuvenation
– Pigmentation Treatment
– Scar Revision
– Vascular / Leg Vein Treatment
– Dark Tattoo RemovalUsed by physicians around the world, M22 enables you to treat more types of patients and conditions with better outcomes.4 Multiple Technologies In One Modular SystemM22 grows with your practice and can expand to your treatment needs and adapts to future applications as they emerge. Universal IPL
Optimal Pulse Technology (OPT)
Single handpiece with changeable filters and lightguides
For IPL skin treatments using photorejuvenation ResurFX
The only True fractional non-ablative, with CoolScan scanner
No disposables
For skin resurfacing Multi-Spot Nd:YAG
The only one with Multiple Sequential Pulsing (MSP)
2 sized lightguides, changeable in seconds
For treatment of leg veins and vascular lesions |
Reviews
There are no reviews yet.