| Content | Cynosure MedLite C6 Laser
The MedLite C6 beam is smooth and evenly calibrated, without “hot spots” or uneven spikes of energy typical in other lasers. As a result, the energy is delivered evenly from the perimeter to the center of the beam with no vacuoles or dead areas. This homogenous profile allows more efficient delivery of the energy and more pronounced tissue reaction under the dermis to better fragment the target chromophores.The ultimate proof of a genuine flat-top beam profile is in the tissue reaction, consistent results, less complications and no patient downtime. Standard Gaussian beam profiles of other lasers tend to scatter on the skin’s surface requiring more shots to fragment the target chromophores causing unnecessary damage to the epidermis. The MedLite C6 delivers long-term, consistent flat-top capability, even after the laser is operated for long periods of time. The stabilized and consistent temperature of our lasers optimizes the output of the homogeneous beam.The ConBio engineering team has the longest history in manufacturing a flat-top beam – and they conduct ongoing improvement analysis and evaluation to ensure we meet practitioner expectations of safety, reliability and superior performance.What the MedLite C6 Laser Can Do For Your Aesthetic Practice
A MedLite C6 EO Q-switched Nd:YAG laser is a valuable addition to any aesthetic practice. With a powerful, compact and reliable aesthetic laser, physicians can offer patients a greater range of treatments, regardless of skin type. The MedLite can help attract new patients – while expanding services available to existing patients. The C6 offers 1064 nm and 532 nm wavelengths. With the use of MultiLite Dye Laser Handpieces the Polymer Dye HP can convert the 532 nm wavelength to both 585 nm and 650 nm, for a total of four possible wavelengths across a variety of procedures.MedLite C6 Laser Technology
The MedLite C6 EO Q-switched laser utilizes the latest in multi-wavelength, articulated-arm-delivered laser technology. Representing the next generation of Q-switched technology, the MedLite uses an electro-optic (EO) high-speed shutter to produce nanosecond pulse widths. Peak energy is dispersed throughout the epidermis faster than the relaxation time of the healthy tissue. The result is a PhotoAcoustic Therapy effect, a safe, effective way to deliver energy precisely where it is needed. Contact us if you would like to learn more about the PhotoAcoustic action or any aspect of our MedLite C6 lasers.MultiLite Dye Laser Handpieces for Four Wavelengths
The ConBio MultiLite Dye Laser Handpieces are designed for the MedLite C6 and RevLite lasers. These dye-impregnated polymer rods convert the 532 nm wavelength to either 585 nm or 650 nm, providing a total of four wavelengths and significantly expanding treatment options for patients.Nd:YAG Crystal
The backbone of the MedLite C6 is the Nd:YAG crystal, a solid-state material used for years in scientific and aesthetic communities. The ConBio MedLite C6 laser has the added benefit of being EO Q-switched, the next generation of Q-switching that produces high-speed repetition pulse durations.AimLite (Aiming Beam Technology)
The AimLite system provides physicians with assistance in performing laser skin resurfacing and other procedures in discrete and/or delicate areas such as near the mouth and eyes. Specifically, the AimLite produces a red aiming beam that is co-linear with the treatment beam, enabling the physician to achieve accurate positioning of the beam for best results.Cynosure MedLite C6 LaserLaser Medium:Nd YAG & Dye Impregnated Polymers
Operating Parameters:EO Q-Switched, Nominal Delivered Energy at end of Articulated Arm with no Handpiece
1064 nm:1.0 Joule
532 nm:400 mJ
Converted Wavelengths
585 nm:250 mJ
650 nm:150 mJ
Nominal Pulse Energy Density
1064 nm:12.0 J/cm2 @ 3.0 mm spot size
532 nm:5.0 J/cm2 @ 2.0 mm spot size
585 nm:8.0 J/cm2 @ 2.0 mm spot size
650 nm:4.5 J/cm2 @ 2.0 mm spot size
Pulse Width: 5-20 ns
Rep Rate:Single shot, 1, 2, 5, and 10 Hertz
Spot Size
1064 nm:3, 4, 6 & 8 mm
532 nm: 2, 3, 4 & 6 mm
Cooling:Closed Cycle Water to Air Heat Exchanger
Physical Parameters
Input Power:220 V, Single Phase, 8 Amps or 110 V, Single Phase, 15 Amps
Weight:127 Pounds (58 kg)
Size:28.5 in. (72.5 cm) Depth x 12 in. (30.5 cm) Width x 31.8 in. (81 cm) Height, without articulated arm 44.5 in. (113 cm) HeightMedLite C6 Q-Switched Nd:YAG LaserMedLite C6 Clinical Procedures
Multi-Color Tattoo Removal
Wrinkle Reduction
Acne Scar Reduction
Non-Ablative Skin Resurfacing
Pigmented Lesion (sun spot) Removal
Hair Removal
Vascular Lesion Removal
Dermal Lesions
Nevus of OtaIn 1992, ConBio launched the original MedLite laser, introducing PhotoAcoustic technology to the dermatology community – the use of high peak power and nanosecond pulse duration to target chromophores with a photomechanical action. This non-ablative Q-Switched Nd:YAG gave practitioners the ability to treat a wide range of aesthetic indications safely and effectively, with no downtime or patient discomfort.Since then, the MedLite has evolved, incorporating more sophisticated engineering, more power and greater efficiences. PhotoAcoustic technology is delivered through a superior flat-top beam profile – a hallmark of the MedLite laser – without spikes or hot spots that are prevalent in other Q-Switched Nd: YAG lasers.Today, the MedLite laser is the workhorse of many aesthetic practices worldwide.The Benefits of a MedLite C6 EO Q-switched LaserA MedLite C Series laser is a safe, premium-engineered, easy-to-use aesthetic laser designed for versatility and effectiveness in a wide variety of applications. ConBio has made continual improvements to the MedLite laser since its introduction in 1992, increasing its power output, reducing its size, and introducing valuable features to maintain high levels of physician and patient satisfaction. Today, the MedLite C6 is best known for its PhotoAcoustic effect, a combination of high power and nanosecond pulse widths that deliver peak energy throughout the layers of the epidermis faster than the normal relaxation time of the tissue. The result is a safe, effective way to harness peak power.Cynosure MedLite C6 LaserCompact
Small footprint
Designed for easy mobility, making it ideal for practices with limited space or multiple treatment roomsConvenient
Easy-to-use control panel
Multi-spot handpiece is ideal for a wide variety of treatment parameters, offering four spot sizes from 2-8 mm
Articulated arm stores neatly away in a protective, space-saving vertical position when not in use
Uses standard electrical voltage
Reliable solid-state technologyCost Effective
Multiple application capabilities and high utilization
Low maintenance costs
Dual wavelengths (1064 nm & 532 nm)
MultiLite Dye Laser Handpieces expand wavelength capabilities to 585 nm and 650 nm
Economical, with proven return on investmentWhy MedLite?
Because of the versatility that comes with multiple wavelengths and nanosecond Q-switched technology, doctors are able to perform a wide range of aesthetic laser treatments, from wrinkle and acne scar reduction, multi-color tattoo removal, pigmented lesion (sun spot) removal, hair removal, and vascular lesion treatments.Flat-Top Beam Profile
ConBio was the first company in the aesthetic laser market to create a truly homogenous flat-top beam profile for a Q-Switched Nd:YAG laser. The secret is in high-quality components – a carefully selected array of superior elements simply not found with inferior Q-Switched Nd:YAG lasers that try to copy our technology. | Cynosure Ultracel Q+ Device
ULTRAcel Q+ which is produced by Cynosure (the same leaders as our Picosure laser) and is the only technology in the world to use a linear cartridge, offering double the results in a much quicker time and much more comfortable treatment and with exceptional results. Cynosure Ultracel Q+ a next generation HIFU technology which treats fine lines and wrinkles, tightens skin and removes stubborn fat cells.Reduce stubborn fat cells & tighten
Introducing Cynosure ULTRAcel Q+, high intensity focused ultrasound (HIFU), an effective non-surgical treatment that promotes neocollagenesis. ULTRAcel Q+ helps to reduce stubborn fat cells and tightens areas on the face and body with the additional benefit of reducing flushing and redness.Setting the Cynosure ULTRAcel Q+ apart from the competition is the option of a linear cartridge which is unique to the device providing the fastest treatment time in market with the capability of performing a single shot in under 1.5 seconds. This allows the device to perform fat reduction, unlike any other competitor devices.Less Than 3 Minutes For a Full Face Treatment- Face and Body Tightening
- Improves Skin Laxity and Addresses Stubborn Fat Pockets
- A Choice of Two Cartridge Types, Either Tighten and De-Volumize or Just Tightening Alone
- Low Cost Consumable
- Faster Treatment Times
Cynosure Ultracel Q+ DeviceWhat is HIFU?
HIFU stands for High Intensity Focused Ultrasound. ULTRAcel Q+ reaches deep skin tissues for a naturally wound healing response to lift and tighten , this is a great option for clients who do not wish to have injectables or surgery and absolutely no downtime and being a very tolerable treatment, it has fast become the go-to treatment for a natural lift.Ultrasound therapy (HIFU) shoots ultrasound waves into the skin, where they act by heating targeted tissue, by heating this area of skin upto 65 degrees this results in a tightening of the SMAS and stimulating the body’s natural collagen production. The SMAS layer is the same muscle in which surgeons tighten during a surgical facelift. While there is a noticeable instant tightening, once the body starts producing collagen, the skin tightens and firms significantly.HOW SOON DO YOU SEE RESULTS?
Generally the skin will begin to look smoother and tighter after the first treatment, some clients receive an instant lift however 2 sessions are required for best results. The results from the treatment will continue to improve for up to six months, as the collagen continues to regenerate. Using active ingredient skin care will help with longevity to treatments. Results do vary from each individual and depending on the original condition of the skin and deeper tissue, ability to produce healthy collagen ect and degree and cause of damage.When can I return to work and the gym?
You can return to work immediately after treatment, you may have a slight pinkness in the skin, makeup is fine the next day, we recommend no gym for 24 hours post treatment , however overall minimal to No downtime treatment. | Cynosure Smartlipo Triplex Laser
Cynosure Smartlipo Triplex Laser With three unique wavelengths and intelligent delivery systems, it’s no wonder our Smartlipo Triplex Workstation is leading the charge in laser lipolysis.The new standard in laser lipolysis with more than 45 clinical studies and over 10 years of clinical success, our Smartlipo Triplex Workstation has remained the leader in laser lipolysis. Have the confidence to safely and effectively deliver the optimal lipo treatments your patients want and deserve.Laser Lipolysis Redefined
Be ready to meet your patient’s ever increasing demands with the expanded clinical capabilities of Cynosure Smartlipo TriPlex the first multiplex triple wavelength laser lipolysis workstation that’s designed to treat all your patient’s body contouring concerns:- More effective laser lipolysis
- Proven tissue coagulation resulting in tightening
- Reliable, controlled energy delivery
- Reduced liposuction treatment time and less downtime
- Less bleeding and bruising
- High-definition sculpting capabilities
Cynosure Smartlipo Triplex Laser includes 3 wavelengths: 1064nm, 1320nm and 1440nm. The machine is the latest generation of our laser lipolysis workstations. These versatile wavelengths can be used independently or can be uniquely blended using our MultiPlex technology.The new and improved Smartlipo TriPlex design now has:- 2x larger display
- Easier to use software interface
- Longer lasting ThermaGuide design
With 40X greater absorption in fatty tissue, the addition of the 1440 nm wavelength to Smartlipo significantly exceeds the performance of all diode lasers (924 nm and 980 nm) on the market. See for yourself how 1440 nm has the highest absorption of fatty tissues over any other wavelength on the market.- Blend 1064nm 1440nm to effortlessly disrupt fatty tissue with less downtime
- Blend 1064nm 1320nm to tighten tissue through coagulation in the subdermal layer
Ideal Treatment Applications
Smartlipo Triplex is ideal for both smaller and larger fat deposits, tissue tightening, faster procedure times, fibrous areas or secondary liposuction cases, adipose specific technology and high definition procedures. The right wavelength blend and intelligent delivery systems help you deliver the maximum Smartlipo TriPlex dose, safely.SmartSense – ThermaGuide – ThermaView – Cynosure’s unique, intelligent delivery systems are so smart, they can help you prevent over-treatment, determine your endpoint and minimize complications with integrated temperature and motion sensing. You’ll find all three systems are available for Smartlipo TriPlex, the laser lipolysis system that started it all.| System Type: Nd Yag | | Wavelength | 1064 nm | | Pulse Width | 500 ms | | Power Output | 40 Watts | | Rep Rate | 40 Hz | | System Type: Infared | | Wavelength | 1320 nm | | Pulse Width | 1000 ms | | Power Output | 24 Watts | | Rep Rate | 40 Hz | | Wavelength: Erbium Glass | | Wavelength | 1440 nm | | Pulse Width | 1000 ms | | Power Output | 15 Watts | | Rep Rate | 25 Hz | | Aiming Beam: Red | | Electrical | 230 VAC/16A | | Dimensions | 38″ x 20″ x 27″ |
| Cynosure Palomar Picosure Pro DevicePICOSURE PROCynosure Palomar Picosure Pro. Here is a detailed comparison table outlining the key specification differences between the Cynosure PicoSure and PicoSure Pro devices: | Specification | PicoSure | PicoSure Pro | | Wavelengths | 755 nm (standard), optional 532 & 1064 nm | 755 nm (standard), optional 532 & 1064 nm | | Pulse Duration | 550–750 ps | 500–900 ps | | Maximum Pulse Energy | 165–200 mJ | 300 mJ ± 20% | | | | | Handpieces | Zoom: 2–6 mm
Fixed: 6, 8, 10 mm | Zoom: 2–6 mm
Fixed: 5, 6, 8, 10 mm | | Adjustable Fluence | No | Yes | | Focus Lens Array | Yes (Focus™ Lens Array) | Yes (Platinum Focus™ Lens, 40% more shots) | | Flat Lens | No | Yes | | FDA-Cleared Indications | Pigmented lesions, tattoo removal, acne scars, wrinkles | Pigmented lesions, tattoo removal, acne scars, wrinkles, melasma, nevus of Ota, Hori’s nevus | | Turbo Mode | No | Yes (for tattoo removal) | | Treatment Speed | Standard | Faster (10-minute treatments, faster startup) | | User Interface | Standard | Modern, more intuitive | | Power Supply | 200–240 V, 4.5 kVA, 30A | 200–240 V, 4.5 kVA, 30A | | Weight | ~375 lb (171 kg) | ~375 lb (171 kg) |
Key Differences : Cynosure Palomar Picosure Pro Device- Energy & Fluence: PicoSure Pro offers up to 50% more energy per pulse and higher maximum fluence, allowing for more effective treatments and greater versatility
- Handpieces: PicoSure Pro introduces a new 5 mm fixed handpiece for precise treatments and offers adjustable fluence for all handpieces, enabling more customization
- Focus Lens: The Pro model features the Platinum Focus™ Lens Array with 40% more shots per lens, improving efficiency and longevity
- FDA Clearances: PicoSure Pro is uniquely FDA-cleared for treating melasma, nevus of Ota, and Hori’s nevus-conditions not specifically cleared on the original PicoSure
- Turbo Mode: The Pro model includes a Turbo mode for enhanced tattoo removal performance
- User Experience: The Pro features a modernized interface, faster startup, and improved workflow for higher patient throughput
Summary:
PicoSure Pro is an upgraded, more versatile, and powerful version of the original PicoSure, offering higher energy, more handpiece options, advanced lens technology, and additional FDA-cleared indications for pigmentary disorders, making it suitable for a broader range of patients and conditions.Cynosure Palomar Picosure Pro Specifications- Nominal Wavelength: 755 nm
- Pulse Duration: 550-750 ps
- Pulse Energy: 165-200 mJ
- Spot Sizes: Zoom – 2.0 mm – 6.0 mm, Fixed – 6.0 mm, 8.0 mm, 10.0 mm
- Optional Wavelength Add On: 532 nm
- Electrical Power: 200-240 V, 4.5 kVA, 50/60 Hz, single phase
- Electrical Service Requirement: 30 Amp
- 755 nm Applications:
• Tattoo Removal for Skin Types I-IV
• Pigmented Lesion Removal for Skin Types I-IV
- 755 nm with Focus Lens Applications:
• Pigmented Lesion Removal for Skin Types I-IV
• Acne Scars for Skin Types I-IV
• Wrinkles for Skin Types I-IV
- 532 nm Applications
• Tattoo Removal for Skin Types I-III
| Cynosure Potenza Microneedling MachineThe world’s first RF microneedling machine that combines monopolar and bipolar radiofrequency at 1 or 2MHz in a single device, creating four unique RF modes. With a variety of tips, needle alignment options, and the ability to treat anywhere – Potenza’s versatility cannot be overstated. What separates Potenza from the other Microneedling Machines on the Market?The Potenza has an array of various tips to utilize depending on the area and treatment you are performing, as well as the ability to switch between mono and bipolar RF at 1 or 2 mhz. The Unmatched Versatility of the Potenza RF Microneedling Machine:Potenza takes Radio Frequency microneedling to new levels through the number of customization options available. These options allow Potenza to treat all skin types, anywhere on the body, any time of the year. The RF energy heats the underlying layers, causing constriction and tightening of the skin through soft-tissue coagulation, as well as causing the stimulation of collagen and elastin production. Because the RF energy is delivered so deeply, it can produce faster, more dramatic results. World’s first 4-mode RF Monopolar, bipolar, 1 & 2 MHz capabilities. Provide shallow and deep treatments in one system. Semi-insulated vs Insulated Tips – What’s the difference?Another instance of our Potenza microneedling machine’s versatility lies within the options of semi-insulated and insulated tips.
Semi-insulated tips allow for increased coverage in a single insertion, whereas insulated needles are great for deep (bipolar) treatments and targeted areas at superficial (monopolar) depths. Insulated Needles- 16, 25, and 49 needle array
- Adjustable depth 0.5mm – 4.0mm
- Used for both Targeted and deep treatments
Single Insulated Needles- 0.8mm, 1.2mm, 1.5mm depths
- Used to precisely target and improve blemishes found in the skin

Fusion Tip- 21 insulated needle array
- Adjustable 0.5-2.5mm depths
- Uses a dual-air chamber design to capture and release air towards the skin in order to enhance the penetration of topicals into the channels

Tiger Tip – Semi Insulated - 16, 25, and 49 needle array
- Adjustable depth 0.5mm – 4.0mm
- Used for treating more tissue in a single treatment without sacrificing the epidermis
THE ONLY OF ITS KINDMany different topicals are used with RF microneedling devices today however, only 1- 5% of most topically applied medications are typically absorbed by the skin, and the amount that reaches the target depth is frequently insufficient to be effective. The Fusion Tip is specifically designed to drive topicals into the dermis while simultaneously creating a thermal coagulative event. Key benefits: · Ability to drive 67% more topicals into the skin than other devices · More efficient use of expensive topicals · Better patient experience and customized cocktails What are the treatment areas for Potenza? Part of Potenza’s versatility lies in the available treatment areas, as both face and body are able to be treated. The list of treatable areas are as follows: - Full Face
- Forehead
- Crow’s Feet
- Upper Cheek
- Lower Eyes
- Lower Cheek
- Nose
- Upper & Lower Lip
- Chin
- Jawline
- Neck
- Decolletage
- Elbows
- Abdomen
Indicated Uses - Tighten skin
- Improve blemishes
- Revitalize skin
SPECIFICATIONS - Cynosure Potenza Microneedling Machine RF Type: Bipolar, Monopolar Power: Max 50 Watts Frequency: 1MHz, 2MHz Repetition Rate: 0.5-3.0 sec (0.1 sec step) Needle Thickness: 0.25 Treatment Duration: 5-500ms (5ms.step) Electrical Power: 100-240V, 50/60Hz, 500VA Dimensions: 19.82 x 14.40 x 14.22 inches (Including cable stand: 21.66 x 27.60 x 14.41 inches) Weight: Approximately 21 lbs. Cart: 18.82 x 18.98 x 38.08 inches, 71.13 lbs Handpieces: - 100-7043-001: Motorized Handpiece;
- 100-7043-002: AC Handpiece;
Motorized Handpiece Tips 100-7043-051: S-16 100-7043-052: S-25 100-7043-053: S-49 100-7043-054: I-16 100-7043-055: I-25 100-7043-056: I-49 AC Handpiece Tips 100-7043-060: P1-08 100-7043-061: A1-12 100-7043-062: A1-15 | Cynosure Elite Plus DeviceThe Cynosure Elite Plus Aesthetic Workstation is a high-powered, dual-wavelength system that delivers energy faster for faster results. Utilizing dual wavelengths (Alexandrite 755nm and Nd:YAG 1064nm) to target different aspects of these conditions, offering versatility for various skin types and hair colors. The Elite+s wavelengths are the gold standard for permanent hair removal, facial and leg veins, epidermal pigmented lesions, and wrinkle reduction on all skin types. The Best of Both Worlds, Now Even Faster The Elite+ Aesthetic Workstation is built on two clinically proven wavelengths the 755 nm Alexandrite and 1064 nm Nd:YAG lasers, which allow you to perform aesthetic laser treatments with unsurpassed efficacy and client comfort. Elite+ features larger spot sizes and higher fluences to deliver energy faster with exceptional results. Larger Spot Sizes and Higher Power for Faster Performance Reduce your procedure time with Elite+s larger spot size. Our standard large 18 mm spot size gives you 44% more treatment area per pulse compared to standard 15 mm spot sizes. Optimal Wavelength for any Patient or Procedure The high-powered 755 nm Alexandrite wavelength is highly absorbed by melanin. It has proven long-term results for pigmented lesion removal and hair reduction, permanently reducing hair by an average of 79% after just three treatments. The 1064 nm Nd:YAG is the safest wavelength for permanent hair reduction on darker skin types and tanned skin. Its also the wavelength of choice for treating facial and leg veins, the most common form of vascular lesions. Faster Treatment Sessions By enabling you to deliver more energy faster, the Elite+ helps increase your client throughput, resulting in a more productive and profitable practice. Treatment Customization Elite+ offers a variety of spot sizes and adjustable pulse durations, allowing you to customize treatments to accommodate your patients specific needs. Choose the optimal wavelength to maximize efficacy and comfort for unwanted hair, pigment, and vascular lesions, regardless of the patients skin type. Indicated Uses - Laser Hair Removal for All Skin Types
- Pigment for All Skin Types
- Vascular Lesions for All Skin Types
- Skin Rejuvenation
- Wrinkle Reduction
Specific Uses : Cynosure Elite Plus Device - Hair Removal:
- The laser is effective for permanent hair reduction on various body areas, including the face, back, chest, arms, legs, underarms, and bikini area.
- Vascular Lesions:
- It treats a range of vascular concerns like spider veins, broken capillaries, and hemangiomas.
- Pigmented Lesions:
- The laser targets sun spots, age spots, and other pigmented lesions to improve skin tone and clarity.
- Skin Rejuvenation:
- It stimulates collagen production, leading to improved skin texture, tone, and a reduction in fine lines and wrinkles.
- Tattoo Removal:
- The Alexandrite wavelength is particularly effective for removing certain types of tattoos.
Additional Features:- Customizable Treatments:
- Adjustable spot sizes and pulse widths allow practitioners to tailor treatments to individual patient needs.
- Advanced Cooling: The device features cooling technology to enhance patient comfort and minimize the risk of burns, according to Laseraid UK.
- Fast and Efficient:
- The laser can deliver treatments in a relatively short amount of time, especially for larger areas.
System Type: Alexandrite & Nd YagAlexandriteWavelength: 755 nm
Pulse Width: adjustable 0.5 – 300 msec
Maximum Fluence per Spot Size
18 mm: 20 J/cm2
15 mm: 30 J/cm2
12 mm: 45 J/cm2
10 mm: 50 J/cm2
7 mm: 60 J/cm2
5 mm: 50 J/cm2
Maximum Rep Rate: 3 Hz1064 Nd YagWavelength: 1064 mm
Pulse Width: adjustable 0.4 – 300 msec
18 mm: 24 J/cm2
15 mm: 35 J/cm2
12 mm: 50 J/cm2
10 mm: 80 J/cm2
7 mm: 160 J/cm2
5 mm: 240 J/cm2
3 mm: 300 J/cm2
Rep Rate: 5 Hz |