| Content | Rotor-Gene Q 5plex HRM
Each tube spins in a chamber of moving air, keeping all samples at precisely the same temperature during rapid thermal cycling. Detection is similarly uniform. When each tube aligns with the detection optics, the sample is illuminated and the fluorescent signal is rapidly collected from a single, short optical pathway.This thermal and optical uniformity results in sensitive, precise, and fast real-time PCR analysis (see figure “Precise real-time PCR analysis”). It also eliminates sample-to-sample variations and edge effects. These are unavoidable in traditional block-based instruments due to temperature gradients across the block and multiple, complex optical pathways. The rotary design delivers well-to-well variation ±0.02°C Uniform detection eliminating the need for ROX reference dye Fast ramping and negligible equilibration times for short run times Complete confidence in your results!The unrivaled optical range enables multiple applications Whether your essay is based on intercalating dyes such as SYBR Green, probes such as hydrolysis (TaqMan), hybridization (FRET), Scorpion probes, or other multiplex chemistries, the Rotor-Gene Q meets your requirements. With up to 6 channels spanning UV to infrared wavelengths, the cycler delivers the widest optical range currently available (see Table “Channels for optical detection”). In addition, the software allows you to create new excitation/detection wavelength combinations, which means that the Rotor-Gene Q is compatible with dyes you may use in the future.The unique centrifugal design of the Rotor-Gene Q 5plex HRM ensures optimal thermal and optical uniformity between samples, which is critical for precise and reliable analysis . Each tube spins in a chamber of moving air, keeping all samples at precisely the same temperature during rapid thermal cycling. Detection is similarly uniform. When each tube aligns with the detection optics, the sample is illuminated and the fluorescent signal is rapidly collected from a single, short optical pathway. This thermal and optical uniformity results in sensitive, precise, and fast real-time PCR analysis. The rotary design delivers up to 20 times better thermal precision in real-time cycling compared with traditional block-based instruments. Have complete confidence in your real-time PCR test by using highly precise rotary technology. Robust optical range enables multiple applications
With a choice of up to 6 excitation sources and 6 detection filters, combined with a short, fixed optical path, the
Rotor-Gene Q MDx 5plex HRM can be used for multiplex reactions (see table), ensuring minimum fluorescence variability between samples and eliminating the need for calibration and compensation. | Blue | 365 ± 20 | 460 ± 20 | Marina Blue, Edans Bothell Blue, Alexa
Fluor 350, AMCA-X, ATTO 390 | | Green | 470 ± 10 | 510 ± 5 | FAM, SYBR Green I, Fluorescein,
EvaGreen, Alexa Fluor 488 | | Yellow | 530 ± 5 | 557 ± 5 | JOE, VIC, HEX, TET, CAL Fluor
Gold 540, Yakima Yellow | | Orange | 585 ± 5 | 610 ± 5 | ROX, CAL Fluor Red 610, Cy3.5,
Texas Red, Alexa Fluor 568 | | Red | 625 ± 10 | 660 ± 10 | Cy5, Quasar 670, LightCycler
Red640, Alexa Fluor 633 | | Crimson | 680 ± 5 | 712 high pass | Quasar 705, LightCycler Red705,
Alexa Fluor 680 | | HRM | 460 ± 20 | 510 ± 5 | SYBR Green I, SYTO9, LC Green,
LC Green Plus+, EvaGreen |
Minimum maintenance; maximum convenience
The Rotor- Gene Q 5plex HRM is engineered to reduce the need for maintenance and to maximize ease of use. This saves time and costs, and keeps the instrument operational for continuous testing. The outstanding robustness of Rotor-Gene technology is proven in several thousand installations worldwide.Convenient features of the Rotor-Gene Q MDx 5plex HRM include: - Lifetime guarantee on highly stable LEDs, no expensive and time consuming lamp replacement, and no gradual performance loss
- Cost-effective and easy temperature-accuracy verification (see below)
- Optical calibration not required at installation, or when the instrument is moved
- “Plug and play” connectivity between computer and instrument
- No sample block to clean
- No condensation or bubbles in the reaction due to rotation
- Small, light, and robust instrument — simply place it where you want it
Procedure Nucleic acids are purified using the designated manual or automated purification kit that is validated for the downstream assay. After assay setup, the assays are then transferred to the Rotor-Gene Q MDx 5plex HRM for PCR and data analysis. Easy routine verification
Certified laboratories often want to verify thermal accuracy. For most cyclers, this usually requires interaction with a service engineer. With the Rotor-Gene Q MDx 5plex HRM, this is not necessary. Instead, the easy-to-use, cost-effective proprietary Rotor-Disc OTV (Optical Temperature Verification) Kit automates temperature accuracy testing. The full procedure takes less than 30 minutes and can be performed by any user.Applications The Rotor-Gene Q MDx 5plex HRM is intended for in vitro diagnostic use. The Rotor-Gene Q MDx 5plex HRM instrument is intended to be used only in combination with QIAGEN kits indicated for use with Rotor-Gene Q MDx 5plex HRM instruments for applications described in the respective QIAGEN kit handbooks. Software Software enables quantification and enhances data security
The user-friendly software provides simplicity for the routine user, as well as an open platform for the more advanced developer. Standardization in your laboratory is supported by software wizards, templates for run, processing, and analysis procedures, and various pre-defined report formats.Data security, from starting the run to exporting the results, is assured by audit trails, digital signatures, and individual user management. Each Rotor-Gene Q MDx 5plex HRM instrument is supplied with an unlimited software user license for your institute, enabling you to access and analyze your test results on as many computers as you want — in the laboratory or in the office.Features | Specifications | | Altitude | Up to 2000 m (6500 ft) | | Dimensions | Width, 37 cm (14.6 in.); Height, 27.5 cm (10.8 in.); Depth (without cables), 42 cm (16.5 in.); Depth (door open), 56 cm (22 in.) | | Heat dissipation/thermal load | Average, 0.183 kW (632 BTU/hour); Peak, 0.458 kW (1578 BTU/hour) | | Humidity | 10–75% (noncondensing) | | Operating temperature | 18–30°C (64–86°F) | | Optical System | 5 channels plus HRM; Excitation sources: high-energy light-emitting diodes; Detector: photomultiplier; Acquisition time: 4 seconds | | Overvoltage category | II | | Place of operation | For indoor use only | | Pollution level | 2 | | Power | 100–240 V AC, 50–60 Hz, <520 VA (peak); Power consumption 8 VA (standby); Mains supply voltage fluctuations are not to exceed 10% of the nominal supply voltages; F5A 250 V fuse | | Samples per run (throughput) | Tubes 0.2 ml, 36 samples/run; Strip Tubes 0.1 ml (4 tubes), 72 samples/run; Rotor-Disc 72, 72 samples/run; Rotor-Disc 100, 100 samples/run | | Software | Rotor-Gene Q software, supplied on the installation CD provided | | Storage conditions | 15–30°C (59–86°F) in manufacturer’s package; Max. 75% relative humidity (noncondensing); Environmental class 1K2 (IEC 60721-3-1) | | Technology | Real-time PCR cycler | | Thermal performance | Temperature range, 35–99°C (95–210.2°F); Temperature accuracy, ±0.5°C (calibrated using Rotor-Disc OTV procedure); Temperature resolution, ±0.02°C (smallest programmable increment); Temperature uniformity, ±0.02°C | | Transportation conditions | –25°C to 60°C (–13°F to 140°F) in manufacturer’s package; Max. 75% relative humidity (noncondensing); Environmental class 2K2 (IEC 60721-3-2) | | | | Weight | 12 kg (26.5 lb.), standard configuration |
| 2019 Lumenis Splendor X- Laser Hair Removal
Lumenis Splendor X Laser Hair RemovalThe Alexandrite wavelength at 755 nm, which is ideal for treating skin tones 1, 2 and 3 (fair and light skin tones). It is highly absorbed in melanin and is therefore not safe for use on darker skin tones.
The Nd:YAG wavelength at 1064 nm, which is ideal for treating skin tones 4, 5 and 6 (4 being tanned skin and 5 and 6 darker skin tones) as the absorption by melanin is much lower than with the Alexandrite wavelengthThe Lumenis Splendor X has been introduced to be a player in the solid state Nd:YAG and Alexandrite laser hair removal market. The gold standard for hair removal has always been considered Alexandrite 755nm for light skins and Nd:YAG 1064nm for dark skins.The Lumenis Splendor X combines both in a unique way with blended emission.Instead of firing a single wavelength at a time the Splendor X allows you to fire both wavelengths simultaneous in adjustable amounts to suit the skin type and hair types. This means you are target multiple chromophores at any given time given enhanced results across the board.The Lumenis Splendor X also allows the user to choose between square and round spot sizes with large spot sizesLumenis Splendor X Laser Hair RemovalThe Alexandrite wavelength at 755 nm, which is ideal for treating skin tones 1, 2 and 3 (fair and light skin tones). It is highly absorbed in melanin and is therefore not safe for use on darker skin tones.
The Nd:YAG wavelength at 1064 nm, which is ideal for treating skin tones 4, 5 and 6 (4 being tanned skin and 5 and 6 darker skin tones) as the absorption by melanin is much lower than with the Alexandrite wavelengthLaser Hair Removal
Details:2019 Lumenis Splendor X- Laser Hair Removal- Serial Number: SQEAY-19M-XXXXX (message for serial number)
- System Total Shot Count: 560,693
- Alex Shot Count: 221,437
- YAG Shot Count: 339,256
Includes:- Handpiece and Delivery System
- Square Spot Sizes: 2x2mm, 3x3mm, 5x5mm, 10x10mm, 14x14mm, 18x18mm, 20x20mm, 24x24, 27x27mm
- Fiber Pole
- Foot Switch
- System Key
- Operators Manual
- 30 Day Parts and Labor Warranty
| Convergent Solea 2.0 Dental Diode Laser
OVERVIEWMakers of the Solea All-Tissue LaserConvergent Dental, Inc. is a privately owned dental equipment and technology company. The Company’s flagship product, Solea, is a breakthrough technology that enables virtually every cavity prep to be performed anesthesia-free, delivering a dental experience that patients prefer. Solea also enables soft tissue procedures that are blood-free and suture-free with minimal post-op discomfort and remarkably rapid healing.Solea offers a completely different experience for both dentists and patients compared to traditional instruments or earlier laser technology. Solea dramatically increases new patient flow, enables better clinical outcomes, makes you more efficient, and allows you to perform procedures previously referred out.TECHNOLOGY Convergent Solea 2.0 Dental Diode LaserUnique 9.3 µm CO2 LaserOur unique 9.3 wavelength is highly absorbed in tooth structure. The result? Solea actually vaporizes enamel (unlike other lasers that slowly chip it away), giving you the power to work anywhere in the oral cavity from any angle with speed and ease. Whether treating virgin teeth, replacing old restorations, or performing soft or osseous tissue procedures, Solea is the right tool for the job.WHY SOLEAPatients prefer fillings without a needle or a drill.Solea is a breakthrough technology that enables virtually every cavity prep to be performed anesthesia-free, delivering a dental experience patients prefer. Solea also enables soft tissue procedures that are blood-free and suture-free with minimal post-op discomfort and remarkably rapid healing.An Experience That Moves Patients
By eliminating the primary causes of patient anxiety (the needle and the drill), Solea delivers a dental experience patients prefer. When needles, numbness, and the sound of the drill, and the pain are all removed from a patient’s dental experience, two important things happen: 1) Patients never settle for a traditional experience again, and 2) They encourage their family and friends to experience the same.Deliver Better Outcomes
Enjoy the highest degree of control over procedures and practice truly minimally invasive dentistry. For hard tissue, Solea allows for selective tissue ablation, which results in the preservation of healthy tooth structure and minimized risk of iatrogenic damage. Solea also provides a bactericidal effect because laser energy kills all bacteria with which it comes in contact. For soft and osseous tissue, Solea enables precise control and is both atraumatic and virtually blood-free, allowing you to deliver better outcomes than you could deliver using traditional instruments.Work Smarter, Not Harder
By eliminating anesthesia, Solea removes obstacles that slow you down and limit what you can accomplish in a single visit. No more calming patients down, injecting the anesthesia, waiting for it to take effect, and scheduling multiple visits for multi-quadrant dentistry. With Solea, you simply greet the patient, get started, and stay until treatment is complete. Enjoy more control over your schedule and feel like you are working less.Expand Your Practice
Solea dentists perform soft and osseous tissue procedures because they are simple, fast, and minimally invasive. By virtually eliminating bleeding, sutures, and post-operative pain, you can add higher revenue procedures – such as gingivectomies, frenectomies, and flapless crown lengthening – previously referred out or ignored. Your patients will love receiving treatment from a dentist they know and trust, and they will be amazed by the remarkably rapid healing process and absence of post-operative pain. | Lutronic Clarity II
Lutronic’s Clarity II is a high-powered, dual-wavelength platform that effectively delivers a wider range of parameters to help safely and efficiently treat the broadest indications with ease. The innovative design includes: a single fiber for all spot sizes(2-25mm), intuitive interface, and no need for calibration after any parameter change. Clarity II can save time and help facilitate faster, more effective treatments.
Higher power 755/1064nm platform for effective treatments up to 45%* faster.
Brilliantly removes hair, pigment, and vascular lesions in all skin types.
IntelliTrak technology and Temperature Sensing enable increased provider confidence and treatment efficacy.Clarity II
Key Feature
1. Powerful and faster
Provide up to 25mm spot size at a useable >2 Hz
High power performance
Up to 45% faster
2. Intelligent and convenientIntelliTraking system to prevent skip area and consistent treatment
Real time skin temperature monitoring system
3. Designed for versatilityIntelligent memory function to keep track of past treatment history in detail
Zoom cartridge system for treatment areaLutronic Clarity IIHow It Works
The CLARITY II Laser System contains two separate laser resonators, Alexandrite and an Nd:YAG, which generate pulse laser energy at the nominal wavelength of 755nm and 1064nm respectively. The output of each laser generator and the 515nm aiming beam are optically combined on the laser rail so that their beam paths are identical as they exit the laser system. This allows the use of a single delivery system for either the 755nm or 1064nm wavelength.Clarity II
with IntelliTrak technologyHigher-powered 755/1064nm platform laser
Up to 2X faster Laser Hair Removal Txs*
Exclusive shorter pulsewidths available including 1ms setting
for finer facial hairs
Breakthrough intelligent capabilities
IntelliTrak technology for faster more consistent Tx coverage
Temperature Sensing for real-time skin temp feedback
during Tx
Auto-calibration in seconds saves time and
improves productivity
Advanced, easy-to-use platform
Single fiber for all 2-24mm spot cartridges
Numerous skin rejuvenation capabilities including vascular,
pigment, and toning Txs
*At settings of: 755nm, 5ms, 12J/cm2: Clarity II at 22mm, 3Hz, IntelliTrak at 18% overlap vs.
older system at 18mm, 2Hz, and est. ~18% manual overlap. Geometric treatment coverage speed is
11.4cm/second with Clarity II vs. 5.1cm/second with older system. | SIUI CTS-800 Veterinary Ultrasound Machine with Linear Rectal Probe
This small and convenient “Palm-Sized” portable veterinary ultrasound scanner fits in the palm of your hand, and is mostly used for farm animals. Its long battery life and waterproof features makes it the perfect ultrasound scanner for veterinarians on the field.The screen of the SIUI CTS-800V will rotate horizontally or vertically, according to how you are holding it.Gravity Sensor: You can operate the ultrasound system either in transversal layout or vertical layout. It can automatically adapt to two different layouts when you rotate it.Grid for estimation: With grid on the image area you can easily estimate the size of the target substance like follicle fertilized egg etc.SPECIFICATIONS SIUI CTS-800 Veterinary Ultrasound Machine with Linear Rectal ProbeMonitor: 7-inch WVGA LCD monitorWeight: 0.8kg Environmental rating: IP54 (main unit) IP67 (probe head) Battery: 3 hours operation time Display mode: B 2B ZOOM B B/M M Depth: Max to 250mm B gain: 0-100 Image storage: 256 frames Cine loop: 256 frames Probe: L50/7.5 MHz linear rectal probe (standard) L65/5.0 MHz linear rectal probe (optional) R20/5.0 MHz micro convex probe (optional)
– Main unit with 7-inch LCD monitor.
– 1 Probe connector.
– 1 Li-ion battery. 3 hours operation time.
– 1 Adaptor.
– 1 Car Charger.
– Belt and sun shield.
– 1 USB port (Mini).
– Carrying case.PROBES– Rectal Linear L7FVC (6.5/7.1/7.5/8.3/9.0MHz).
– Rectal Linear L5FVC (4.0/4.7/5.0/5.5/6.2MHz).
– Backfat Linear L1FC (150mm, 2.5/3.0/3.5/4.0/5.0MHz).
– Convex C3FC (2.5/3.0/3.5/4.0/5.0MHz).
– Microconvex C5FC (3.5/4.0/5.0/6.5/7.1MHz).CTS-800 is a palm-sized veterinary ultrasound system. Features Weight: 0.8kg Environmental rating: IP54 (main unit) IP67 (probe head) Battery: 3 hours operation time Display mode: B 2B ZOOM B B/M M Depth: Max to 250mm B gain: 0-100 Image storage: 256 frames Cine loop: 256 frames Probe: L50/7.5 MHz linear rectal probe (standard) L65/5.0 MHz linear rectal probe (optional) R20/5.0 MHz micro convex probe (optional) | 2018 Vivace RF Microneedling Radio Frequency Acne ScarsTHE VIVACE EXPERIENCE
The most exciting new technology for aesthetic treatments is the combination of two methods previously used individually for skin rejuvenation, Microneedling and RF Energy. FDA-cleared for your safety, the newest generation, best-in-class Vivace RF Microneedling device, is designed for an incomparable, comfortable experience. Only Vivace boasts a precision robotic motor that brings discomfort to a virtual zero compared to any other device. The results are immediate and improve over time as well, giving you the best of both worlds. Our carefully developed recovery system ensures no one knows you just had a treatment. If you are looking for optimal results, there is no comparison to The Vivace Experience.What is Vivace Fractional RF Microneedling?
The Vivace RF Laser Radio Frequency is the newest generation of microneedling with radio frequency and is effective for fine lines and wrinkles, skin tightening, acne, acne scars, and skin tone, texture and pore size, both on and off the face. It is the most revolutionary contouring and skin tightening system for face, neck, hands and body available, producing immediate, pain-free results.Safe for all skin types, Vivace can offer similar results as ablative and fractional laser procedures, but with significantly less discomfort, downtime, and risk of complications. This revolutionary new treatment also addresses the limitations of older ‘traditional’ RF treatments and heats deeper tissues to a much higher level, which leads to greater collagen production, elastin remodeling and wound contraction previously unattainable with older technology. This is why the Vivace is a game changer in skin rejuvenation and tightening. CLICK HERE to learn moreSlate combines the best device with the newest breakthroughs in numbing, treatment serums and recovery care to create an optimal experience for you that might just keep you from needing other more invasive procedures down the road. The Vivace Experience provides the most dramatic results with less pain and less downtime. The results are both immediate and improve over time with multiple treatments. With results you can see, you’ll look and feel your best at any age.Slate Medspa is the premier Fractional RF Microneedling provider in NJ. We use the most advanced technology to provide a results-oriented skin rejuvenation program. New to Slate Medspa? Call us today at 201-477-5781 to schedule a free consultation and save 20% off your first treatment.How does Vivace Fractional RF Microneedling work?
The Vivace utilizes radio frequency and microneedling to heat the targeted area underneath the epidermis. The Vivace dramatically improves the treatment outcomes compared to other radio frequency microneedling systems.By using insulated needles, Vivace bypasses the epidermis and delivers powerful RF thermal energy to create tens of thousands of fractional coagulation zones in the dermis, facilitating a natural wound healing process. This promotes production of new collagen, remodeling of elastin and wound contraction, enhancing skin laxity. Because the thermal energy is delivered beneath the top layer of skin,Benefits of VIVACE:2018 Vivace RF Microneedling Radio Frequency Acne Scars
Minimizes/Eliminates Fine Lines and Wrinkles
Minimizes/Eliminates Acne Scars & Stretch Marks
Skin Tightening & Texture – Stimulates collagen and elastin production
Treat Sun Damage/Age Spots/Hyperpigmentation
8 Reasons why Slate LOVES Vivace™ RF Microneedling
You’ll see results quickly
Vivace works faster than any other microneedling or laser option. First, the RF Energy creates micro injuries deep in the skin in the form of a matrix. Healthy cells around the newly created matrix promote rapid healing, accelerating collagen production and skin tightening. Secondly, the invisible microchannels in the skin created by the superfine gold-tipped needles remain open for four to six hours allowing maximum absorption the key nutrients and serums applied during the treatment. This would include growth factors, HAs and other cosmeceuticals delivered to the skin in a way that no other treatment can, helping to rapidly rebuild new collagen and elastin.The average patient gets optimal results in just three treatments
Most patients experience noticeably softer, smoother and radiant skin, with improvements in tone, texture and laxity after just one treatment. We can typically achieve optimal results after only three sessions!The treatment is virtually painless
The Vivace Microneedle RF was designed for an incomparable, comfortable patient experience. The unique robotic motor is so precise, it brings the discomfort level to a virtual zero as compared to any other device. The Vivace’s ultra thin needles make it virtually pain-free. A numbing cream is applied before treatment for you to stay comfortable. Our patients here at Slate Medspa consistently report a pain level of “1” on a scale of 1 to 10.There’s no downtime
Vivace’s ultra-thin needles and robotic-assisted mechanism result in an exceptionally precise, even treatment with little-to-no bleeding. In addition, built-in LED Light therapy minimizes post-treatment redness. While we ask patients to wait until the next day before applying makeup, most feel comfortable going out without any makeup.It’s safe for almost any skin type
Patients with darker skin tones can have a more challenging time finding suitable skin resurfacing treatments, as lasers and peels that remove skin layers can risk permanent pigmentation changes. Vivace has 31 Adjustable depths, providing flexibility in treating entire depth or just down deep, bypassing damage to the top layer of skin. This means we can treat a broader array of skin types and tones with absolute precision. In addition, a variable pulse duration means the length of time the needle is engaged with tissue can be precisely controlled based on your skin profile. |
Reviews
There are no reviews yet.